User manual HAFLER P1500
Diplodocs help download the user guide HAFLER P1500.
Preview of the first 3 pages of manual
You either have JavaScript turned off or an old version of Adobe Flash Player Get the latest Flash Player.
User guide HAFLER P1500
Detailed instructions for use are in the User's Guide. P1500 / P3000
Installation & Operation
®
®
an tr
va no s
USA
IN T E HE
MAD
PROFESSIONAL POWER AMPLIFIER AMPL
Declaration of Conformity
Application of Council Directive: 73 / 23 / EEC (Low Voltage Directive) 89 / 336 / EEC (EMC Directive) Standard(s) to which Conformity is Declared: EN55103-1 EN55103-2 EN60065 Manufacturer's Name: Hafler Manufacturer's Address: 546 South Rockford Drive, Tempe, Arizona 85281 Importer's Name: Importer's Address: Type of Equipment: 2-channel Audio Power Amplifier/Speaker Model No.: P1000CE TRM6CE P1500CE TRM8CE P3000CE TRM10sCE 2001 P4000CE TRM12sCE 2002 9505CE
Year of Manufacturing: 1999
2000
2003
Serial Number: I, the undersigned, hereby declare that the equipment specified above conforms to the above Directive(s) and Standard(s)
Place: Hafler Date: 09/01/1999 James C. Strickland, VP Engineering
PERFORMANCE SPECIFICATIONS
P1500/P3000
Frequency Response: 20Hz to 20kHz, ±0.1dB 0.15Hz to 300kHz, +0/3dB Signal-to-Noise: Distortion: Slew Rate: CMRR: Input Impedance: Gain: >100dB "A" Weighted <0.2% 20-20kHz, typically .01% at 1kHz @ rated power into 8 100 V/µs 75dB at 1kHz 47k ohms per phase +14dB min. +29dB max.
P1500
Power Rating: Damping Factor: 75 wpc @8 , 85 wpc @ 4, 170 Watts mono @ 8 350 (to 1kHz); 150 (to 10kHz); 18 (to 100kHz)
16.00
Input Sensitivity Range: 870mV - 4.8V (for 75 W @ 8) 650mV - 3.7V (for 85 W @ 4) Power Consumption: 60W / 500mA @ 120 VAC (Idle Power) 230W / 1.9A @ 120 VAC (1/8 Power 8) 325W / 2.70A @ 120 VAC (Max. Power 8)
19.00 .717 8.410
Dimensions:
19"W x 8-1/2"D x 3-1/2"H (2-rack spaces)
6 3 6 3
sign
sh ort er m al ip pin g sign al
(48.26cm x 21.59cm x 8.89cm) Net Weight: 22 lbs. (9.98kg)
1
cl
th
sh
10
ip
er
10
P1500
15 0dB
trans nova
1
3.470
pin g
m al
al
ort
th
cl
15
0dB
channel 1
channel 2
P1500
P3000
Power Rating: Damping Factor: 150 wpc @8 , 200 wpc @ 4, 400 Watts mono @ 8
17.00
400 (to 1kHz); 200 (to 10kHz); 18 (to 100kHz)
Input Sensitivity Range: 1.2V - 6.9V (for 150 W @ 8) 1.0V - 5.6V (for 200 W @ 4)
9.860
Power Consumption:
120W / 1.00A @ 120 VAC (Idle Power) 350W / 2.9A @ 120 VAC (1/8 Power 8) 600W / 5.00A @ 120 VAC (Max. Power 8)
.717
Dimensions:
19"W x 9-7/8"D x 3-1/2"H (2-rack spaces) (48.26cm x 25.08cm x 8.89cm)
10 6 3
19.00
6
3
sh o th rt erm cli al pp in g sig na l
10
1
P1500
15 0dB
trans nova
1
3.470
sig na l cli pp in g th erm a sh l ort
15
0dB
Net Weight:
23 lbs. (10.43kg) i
channel 1
channel 2
P3000
NOTICE - IMPORTANT SAFETY INFORMATION
CAUTION
RISK OF ELECTRIC SHOCK DO NOT OPEN
! !
The lightning flash with arrowhead symbol within an equilateral triangle is intended to alert the user to the presence of uninsulated "dangerous voltage" within the product's enclosure, that may be of sufficient magnitude to constitute a risk of electric shock to persons. The exclamation point within an equilateral triangle is intended to alert the user of the presence of important operating and maintenance (servicing) instructions in the literature accompanying the appliance. the same three wire grounded connection. It is important that the blades of the equipment's plug be able to fully insert into the mating receptacle. Never remove the round grounding pin on the plug in an attempt to mate to a two wire ungrounded receptacle: use a grounding adaptor with the grounding tab or wire suitably connected to earth ground. 11. NON-USE PERIODS During periods of extended non-use, the power cord should be unplugged from the power source. 12. CLEANING The equipment should be cleaned only as detailed in the operating instructions. 13. OBJECT AND LIQUID ENTRY Care should be taken so that objects and/or liquids, such as cleaning fluids or beverages, are not spilled into the enclosure of the equipment. 14. DAMAGE REQUIRING SERVICE Hafler equipment should be serviced by qualified service personnel when: A. The power supply cord or plug has been damaged, or B. Objects have fallen, or liquid has been spilled into the equipment, or C. The equipment has been exposed to rain, or D. The equipment does not appear to operate normally or exhibits a marked change in performance, or E. The equipment has been dropped, or the enclosure has been damaged. 15. SERVICING The user should not attempt to service the equipment beyond that which is described in the operating instructions. All other service should be referred to qualified service personnel. 16. CARTS AND STANDS The equipment should be used with carts or stands only of sufficient strength and stability for the use intended. An equipment and cart combination should be moved with care. Quick stops and starts, excessive force, and uneven surfaces may cause the equipment and cart combination to topple.
WARNING: TO PREVENT FIRE OR SHOCK HAZARD, DO NOT EXPOSE THIS EQUIPMENT TO RAIN OR MOISTURE.
1.
READ INSTRUCTIONS All the safety and operating instructions of your Hafler equipment should be read before power is applied to the equipment. RETAIN OWNER'S MANUAL These safety and operating instructions should be retained for future reference. HEED WARNINGS All warnings on the equipment and in the operating instructions are important and should be followed. FOLLOW INSTRUCTIONS All operating and use instructions are important and should be followed. HEAT The equipment should be kept away from areas of high temperature, i.e., heater vents, radiators, stoves/ovens, fireplaces, etc. VENTILATION The equipment should be used in an area suitable for proper ventilation. Care should be taken not to impede airflow in and around the cabinet. Do not mount on a carpeted shelf or in a sealed enclosure. Allow for proper clearance above the equipment. WATER AND MOISTURE The equipment should not be used in or around water, such as a bathtub, sink, or swimming area. Also, the equipment should not be used in areas prone to flooding, such as a basement. POWER SOURCES The equipment should be connected only to a power source of the same voltage and frequency as that listed on the rear panel above the power cord entry point. POWER CORD PROTECTION Power cords should be arranged so they do not interfere with the movement of objects in the room: people, fan blades, utility carts, etc. Also, care should be taken that the cord is not pinched or cut, and placed so it is not in danger of being pinched or cut, as in under a rug, around a tight corner, etc.
2.
3.
4.
5.
6.
7.
8.
9.
10. POWER CORD GROUNDING The power supply cord is of a three wire grounded type, designed to reduce the risk of electric shock sustained from a live cabinet. It is assumed to be of suitable length for most uses of the equipment. The use of extension cords and power strips is discouraged unless they are of suitable rating to deliver the required total current for safe operation of all connected equipment. Furthermore, extension cords or power strips must provide
ii
ESPAÑOL
ADVERTENCIA INFORMACION DE SEGURIDAD IMPORTANTE
PELIGRO
RIESGO DE DESCARGA ELÉCTRICA NO ABRÍR.
!
El símbolo de flecha relámpago dentro de un triángulo equilátero, es para alertar al usario de la presencia de "voltajes peligrosos" no aislados en el interior del aparato, los cuales pueden ser de suficiente magnitud para constituir un riesgo de choque eléctrico a las personas. El símbolo de exclamación dentro de un triángulo equilátero, es para alertar al usuario de la presencia de instrucciones importantes de operación y mantenimiento (servicio) en la documentación que acompaña al equipo.
PRECAUCÍON: Para Prevenir el incendio o la descarga electrica, no exponer este equipo a la lluvia o a la humedad.
1.
LEA LAS INSTRUCCIONES Todas las instrucciones de seguidad y operación de su equipo Hafler, deben ser leídas antes de que el equipo sea conectado dléctricamente. CONSERVE EL MANUAL DEL PROPIETARIO Estas instrucciones de seguridad y operación, deben ser conservadas para futuras referencias. CUADROS DE ADVERTENCIAS Todas las advertencias en el equipo y en las instrucciones de operación, son importantes y deben ser seguidas. SIGA LAS INSTRUCCIONES Todas las instrucciones de uso y operación son importantes y deben ser seguidas. CALOR El equipo debe ser mantenido lejos de areas de alta temperatura, como por ejemplo: ventilaciones de calentadores, radiadores, estufas/hornos, hogueras, etc. VENTILACION El equip debe ser usado en áreas con ventilación adecuada. Deben er tornadas las precauciones necesarias para no impedir el flujo de aire dentro y alrededor del aparato. AGUA Y HUMEDAD El equipo no debe ser usado en el agua ó alrededor de ésta, tales como en una bañera, tanque o áreas de nado. También, el equipo no debe ser usado en áreas propensas a inundaciones, tales como en un sótano. FUENTES DE PODER El equipo debe ser conectado a una fuente de poder del mismo voltaje y frecuencia que el indicado en el panel trasero sobre el punto de entrada del cable de corriente. PROTECCION DEL CABLE DE CORRIENTE Los cables de corriente deben ser dispuestos de forma tal que no interfieran con el movimiento de objetos en la sala: personas, aspas de ventilación, carretillas, etc. También, es necesario tener cuidado de que el cable no esté punzado o cortado, y debe estar ubicado de forma tal que esto no ocurra, como podría suceder debajo de una alfombra o al pasar el cable por una esquina aguda, etc.
2.
poder suministrar la corrioente requerida pra la operación segura de todo el equipo conectado. Aun más, las extensiones deben proveer de la misma conección aterrada de tres hiles. Es importante que el enchufe se pueda introducir completamente en el receptáculo. Nunca remeva el pin de aterramiento en un intento por conectar el cable en un receptáculo de dos hilos no aterrado: use un adaptador de aterramiento que esté adecuadamente conectado a un punto de tierra. 11. PERIODOS SIN USO Durante períodos prolongados sin uso del equipo, el cable de corriente debe ser desconectado de la fuente de electrixidad. 12. LIMPIEZA El equip debe ser limpiado solo en la forma que se detalla en las instrucciones de operación. 13. INTRODUCCIÓN DE OBJETOS Y LIQUIDO Deben ser tornadas precauciones con el fin de que objetos y/ó líquidos, tales como fluidos de limpieza y gaseosas, no sean derramados dentro del chassis del aparato. 14. DAÑOS QUE REQUIEREN DE SERVICIO Los equipos Hafler deben ser llevados a servicio por personal calificado cuando: A. El cable de corriente ó el enchufe haya sido dañado, ó B. Objetos ó líquido hayan sido introducidos ó derramado en el equipo, ó C. El equipo haya sido expuesto a lluvia, ó D. El equipo aparenta no operar normalmente ó exhibe un marcado cambio en su desempeño, ó E. El equipo se ha caído, o el chassis ha sido golpeado. 15. SERVICIO El usuario no deberá intentar darle servicio al equipo más allá de lo que está descrito en el instructivo de operación. Todo lo demás, deberá ser referido a servicio por personal calificado. 16. CARRETILLAS Y SOPORTES El equipo podrá ser usado con carretillas y soportes que tengan la fortaleza y estabilidad suficiente para el uso previsto. La combinación equipo/carretilla deberá ser movida con cuidado. Rápidas paradas y arranques, excesiva fuerza y superficies imparejas, pueden causar el volcamiento del conjunto de carretilla/equipo.
3.
4.
5.
6.
7.
8.
9.
10. ATERRAMIENTO DEL CABLE DE CORRIENTE El cable de corriente es del tipo aterrado de tres hilos, diseñado para reducir el riesgo de una descarga eléctrica procendent de un chasis energizado. Se asume que su longitud es suficiente para la mayoría de usos del equipo. El uso de extensiones y multienchufes no es recomendado, a menos que tengan el amperaje adecuado para
iii
FRANÇAIS
ATTENTION: INFORMATIONS IMPORTANTES DE SÉCURITÉ
AT T E N T I O N
RISQUE DE CHOC ÉLECTRIQUE NE PAS OUVRIR
!
La lumière clignotante du symbole de la flêche à l'intérieur d'un triangle équilatéral, à pour objet d'alerter l'utilisateur de la présence "d'un voltage dangereux" non-isolé à l'intérieur du produit, qui pourrait être de magnitude suffisante au risque d'éléctrocution. Le point d'exclamation, à l'intériur d'un triangle équilatéral, à pour objet de prévenir l'utilisateur de l'importance des instructions de fonctionement et de maintenance, jointes à l'appareil. 11. PÉRIODES DE NON-UTILISATON Durant les périodes de non-utilisation, la prise de courant ne devrait pas être branchée à une source d'energie. 12. NETTOYAGE Le matériel devrait être nettoyé en respectant les instructions indiquées. 13. PENETRATION DES LIQUIDES Un attention particulière est éxigée quant à la dispersion de liquides tels que les produits de nettoyage et boissons, de façcon à éviter toute pénetration dans l'enceinte du matériel. 14. DÉGÂT NÉCESSITANT UNE RÉVISION Le matériel Hafler devrait être révisé par des personnes qualifées de service après-vente, lorsque: A. Les fiches ou la prise de courant ont été endommagé, ou: B. De objets sont tombés sur le matériel, ou des liquides s'y sont dispersés, ou: C. Le matériel a été exposé à la pluie, ou: D. Le matériel ne semble pas fonctioner correctement, ou affiche un changement de performance, ou: E. Le matériel a été renversé à terre, ou l'enceinte a été endommagée. 15. REVISION L'utilisateur ne devrait pas essayer de réviser le matériel en allant plus loin que ce qui a été décrit dans le mode d'emploi. Toute autre réviion devrait être confiée à un personnel qualifié. 16. CHARRIOTS ET MEUBLES Le matériel devriat être utilisé avec des charriots et meubles de qualité et stabilité suffisante à son utilisation préconçue. L'ensemble du matériel et du charriot devrait être déplacé avec précaution. Des mises en marche et arrêts brusques, des collisions excessives ainsi que des surfaces inégales peuvent renverser l'ensemble du matériel et du charriot.
AVERTISSEMENT: Afin de prévenir les risques de feu ou de choc, ne pas exposer cet appareil à la pluie ou à l'humidité.
1.
LIRE LES INSTRUCTIONS Le mode d'emploi et les mesures de sécurité de votre équipement Hafler devraient être consultés avant sa mise en marche. CONSERVER LE GUIDE DE L'UTILISATEUR Le mode e'emploi et les mesures de sécurité devraient être conservés pour des références futures. CONSIDÉRATIONS DE MISE EN GARDE Le mode d'emploi et les mises en garde concernant cet équipement sont de grande importance et devraient être suivis. SUIVRE LE MODE E'EMPLOI Le mode d'emploi et les conseils d'utilisation sont importants et devraient être suivis. CHALEUR Le matériel devrait être préservé loin de toute source de chaleur: radiateurs, cuisinière/fours, cheminées,...etc. VENTILATION Le matériel devrait être utilisé dans un endroit à bonne ventilation. Il reste nécessaire de respecter la circulation de flux d'air à l'intérier et autour du meuble. EAU ET HUMIDITÉ Le matériel ne devrait pas être utilisé près d'une source d'eau, telle qu'une baignoire, un évier, ou une aire de baignade. De plus, le matériel ne devrait pas être utilisé dans des lieux sujets aux innondations, tels que les sous-sols. SOURCES D'ÉNERGIE Le matériel devrait seulement être relié à une source d'énergie de même voltage et fréquence que celle indiquée sur le tableau arrière, au dessus de la fiche d'entrée de la prise de courant. PROTECTION DE LA PRISE DE COURANT La prise de courant devrait être arrangée de façon à ne pas interférer avec le déplacement d'objets (chariots, pales de ventillateurs...etc.) ou de personnes à l'intérieur de la pièce. D'autre part, il faudrait faire tres attention à ce que la prise ne soit pas percée ou coupée, ou disposée de façon à risquer de l'être, comme sous un tapis, autour d'un angle pointu...etc.
2.
3.
4.
5.
6.
7.
8.
9.
10. PRISE DE COURANT ÀTROIS FICHES La prise de courant est composée de trois fiches, désignées à réduire le risque de décharge électrique de l'appareil. Elle devrait être de longueur suffisante pour la plupart des utilisations de ce matériel. L'utilisation de rallonge t d'adaptateur est déconsellée à moins dêtre en mesure de fournir la charge électrique requise à un fonctionement sans risque, de tout matériel relié.
iv
DEUTSCH
ACHTUNG WICHTIGE SICHERHEITS INFORMATIONEN
ACHTUNG
GEFAHR EINES ELEKTRISCHEN SCHLAGS NICHT ÖFFNEN
!
Der Blitz mit dem Pfeil, in einem gleihschenkligen Dreieck, soll den benutzer vor unisolierter "gefährlicher Spannung" innerhalb des Gerätes warnen. Das Ausrufezeichen, in einem gleichschenkligen Dreieck, soll den Benutzer darauf aufmerksam machen, da dem Gerät wichtige Operations - und Service - Informationen beigefügt sind.
WARNUNG: Um die gefahr eines elektroschocks oder feuer zu vermeiden, setzen sie das gerät keinem regen oder extremer feuchtigkeitaus.
1.
INSTSRUKTIONEN LESEN Alle Sicherheits- und Operationshinweise Ihres Hafler Equipments sollten vor der Inbetriebnahme gelesen werden. BETRIEBSANLEITUNG AUFBEWAHREN Bewahren Sie die Bedienungsanleitung sorgfältig auf, damit Sie in dieser auch in Zukunft nachschlagen können. WARNUNGEN BEACHTEN Alle Warnungen des Gerätes und der Bedienungsanleitung sind extrem wichtig und müssen befolgt werden. INSTRUKTIONEN BEACHTEN Alle Operations- und Gebrauchshinweise sind extrem wichtig and müssen beachtet werden. HITZE Das Equipment sollte fern von Hitze ausstrahlenden Geräten aufgestellt werden, wie z.B. Heizungen, Öfen etc. VENTILATION Das Equipment sollte so aufgestellt werden, da eine ausreichende Ventialition gewährt wird. WASSER UND FEUCHTIGKEIT Das Equipment sollte nicht im oder in der Nähe von Wasser benutzt werden, wie z.B. in Schwimmbädem, Saunen etc. Es sollte ebenfalls nicht in Überschwämmungsgefährdeten Gebieten aufgestellt werden, wie z.B. Kellerräumen. STROMANSCHLU Das Equipment darf nur an eine Stromversorgung angeschlossen werden, die die gleichen Parameter aufweist, welche auf der Rückseite, über em Anschluterminal des Gerätes, aufgelistet sind. SCHUTZ DER ZULEITUNG Die Zuletungen sollten so verlegt werden, da diese nicht in den Bewegungsbereich anderer Möbelstücke oder Personen hereinragen. Achten Sie darauf, das das Kabel nicht gequestscht oder durchschnittren wird, wie z.B. unter Schränken oder an scharfen Kanten etc.
11. ZEITRÄUME IN DENE DAS GERÄT NICHT GENUTZT WIRD Wird das Gerät über einen längeren Zeitraum nicht genutzt (z.B. Urlaub), ziehen Sie bitten den Netzstecker aus der Steckdose. 12. REINIGEN Reinigen Sie das Gerät nur, wie in der Bedienungsanleitung detailliert beschrieben. 13. EINDRINGEN VON FREMDKÖRPERN Achten Sie darauf, da weder Fremdkörper, noch Flüssigkeiten in das Gerät eindringen. 14. ERFORDERLICHER REPARATURSERVICE Hafler Equipment sollte nur von qualifizierten Service-Technikern instand gesetzt werden, wenn: A. Das Stromversorgungskabel beschädigt wurde B. Eine Flüssigkeit in das Gerät eingedrimgem ist C. Das Gerät Regen ausgesetzt wurde D. Das Gerät nicht mehr ordnungsgemä funktioniert, ggf. nicht mehr die volle Leistung abgibt E. Das Gerät runtergefallen ist oder das Gehäuse beschädigt wurde 15. SERVICE Der Benutzer sollte nur den Service ausführen, der in der Bedienungsanleitung für den Benutzer freigegeben wird. Den weiterführenden Service sollte nur von qualifizierten Tevhnikern durchgeführt werden. 16. AUFSTELLUNG Das Equipment sollte so aufgestellt werden, da der gewählte Untergrund die erforderliche Stabilität aufweist, so da eine gefahrlose Bnutzong gewährleistet wird. Das Equipment und der Untergrund sollte mit äuberster Vorsicht bewegt werden. Bei schnellen Bewegungen oder starkem Abbremsen, kann es zum Umkippen des Equipments kommen.
2.
3.
4.
5.
6.
7.
8.
9.
10. MASSEANSCHLU Das dreiadrige Anschlubkabel ist mit einem Erdungsleiter ausgestattet, welcher die Risiken eines Elektroschocks verringert. Das Kabel hat eine Länge, welche für die meisten Anwendungen völlig ausreicht. Wenn Sie Verlängerungskabel benutzen, achten Sie darauf, das dies die erforderlichen Ströme bertragen können. Benutzen Sie immer dreiadrige Verlängerungskable.
v
ITALIANO
NOTARE IMPORTANTI INFORMAZIONI SULLA SICUREZZA
AT T E N Z I O N E
RISCHIO DI SCARICHE ELETTRICHE NON APRIRE
!
Il simbolo del fulmine in un triangolo equilatero vuole avvertire della presenza di tensioni elevate non isolate e di valore sufficiente per costituire rischio di shock elettrico alle persone. Il punto esclamativo contentuto in un triangolo equilatero vuole avvertire l'utente della presenza di parti di servizio e di manutenzione che sono dettagliate nel manuale di istruzioni.
ATTENZIONE: Per prevenire incendio scariche elettriche, non esporre questo apparato a pioggia o umiditá.
1.
LEGGETE LE ISTRUZIONI Tutte le istruzioni riguardanti la sicurezza ed il funzionamento devono essere lette prima di applicare tensione all'apparato. CONSERVATE IL MANUALE Queste istruzioni riguardanti la sicurezza ed il funzionamento devono essere conservate come riferimento futuro. AVVERTENZE Tutte le avvertenze poste sull'apparato e sul libretto di istruzioni sono importanti e devono essere seguite. SEGUIRE LE ISTRUZIONI Tuttle le istruzioni operative e di funzionamento devono essere seguite. TEMPERATURA L'apparato deve essere mantenuto lontano da tuttle le zone ad alta temperature, termosifoni, termoconvettori, stufe e forni, caminetti ed altro. VENTILAZIONE L'apparato deve essere posizionato in aree convenienti per una corretta ventilazione. Prestare attenzione che sia consentita circolazione d'aria attorno e dentro il cabinet. ACQUA E POLVERE L'apparato deve essere posizionato lontano da zone contenenti acqua, come vasche a bagno, acquari e piscine. Inoltre non deve essere impiegato in aree soggette ad allagamento, come le cantine. REQUISITI DI ALIMENTAZIONE L'apparato deve essere connesso solo ad un'alimentazione della stessa tensione e frequenza di quanto scritto sulla parte posteriore del telaio. PROTEZIONE DEL CAVO DI ALIMENTAZIONE Il cavo di alimentazione deve essere posizionato in modo di non interferire con il movimento di oggetti nella stanza: persone, ventilatori, carrelli, ecc...prestate attenzione anche che il cavo non sia tagliato o spellato e che non possa tagliarsi e spellarsi.
11. PERIODI DI NON UTILIZZO Durante lunghi periodi di non utilizzo, staccare il cavo di alimentazione. 12. PULIZIA L'apparato deve essere pulito solo come indicato dalle istruzioni. 13. INGRESSO DI OGGETTI E LIQUIDI Si deve prestar attenzione che oggetti e liquidi, come fluidi detergenti e bibite, non vengano versati all'interno dell'apparato. 14. RIPARAZIONI Gli apparati Hafler devono essere riparati da personale qualificato quando: A. Il cavo di alimentazione o la spina sono danneggiati B. Oggetti sono caduti all'interno del telaio o quando del liquido è entrato C. Quando l'apparato è stato esposto a pioggia D. Quando l'apparato non sempra funzionare normalmente o quando esibisce un cambiamento di prestazioni o E. Quando è caduto o il telaio è stato danneggiato 15. ASSISTENZA L'utente non deve tentare di prestare assistenza all'apparato, se non per quanto esposto nelle istruzioni. Tutti gli altri interventi devono essere effettuati da un tecnico specializzato. 16. CARRELLI E STAND L'apparato deve essere impiegato su carrelli o stand solo se questi sono sufficientemente solidi e stabili per la funzione a cui si vuole dedicarli. La combinazione di carrello ed apparato deve essere mossa con cautela. Fermate e partenze improvvise, forze eccessiva e superfici irregolari, possono ribaltare la cominzione carrello e apparato.
2.
3.
4.
5.
6.
7.
8.
9.
10. MESSA A TERRA Il cavo di alimentazione è del tipo a tre fili con terra ed è progettato pr ridurre il rischio di shock elettrici. Si presume che sia della lunghezza sufficiente per la maggior parte degli impieghi. L'impiego di prolunghe e adattatori è sconsigliato se questi non garantiscono la potenza sufficiente per i corretto fuinzionamento degli apparati connessi. E altersì importante che vengano sempre impiegate prolunghe con la configurazaione a tre fili con terra.
vi
TABLE
OF
CONTENTS
PERFORMANCE SPECIFICATIONS ............................................................................................................................... i SAFETY PRECAUTIONS ............................................................................................................................................... ii INTRODUCTION ........................................................................................................................................................ 1 FRONT & REAR PANEL VIEW ..................................................................................................................................... 2 INSTALLATION Location ................................................................................................................................................................ 3 AC Line ................................................................................................................................................................. 3 Input ...................................................................................................................................................................... 4 PC Board Layout .............................................................................................................Removable Center Spread Output Connections .............................................................................................................................................. 7 Monophonic Use ................................................................................................................................................... 7 OPERATION Power Switch ........................................................................................................................................................ 7 Level Controls ....................................................................................................................................................... 7 Mono Switch ......................................................................................................................................................... 7 Short Circuit Protection ......................................................................................................................................... 8 LED Indicators ....................................................................................................................................................... 8 Warm Up .............................................................................................................................................................. 8 Cleaning and Maintenance .................................................................................................................................... 8 PC BOARD LAYOUT ................................................................................................................................................... 9 PARTS LIST ................................................................................................................................................................ 10 TECHNICAL REFERENCE Field Service Considerations ................................................................................................................................ 12 Theory and Operation of trans·nova ................................................................................................................... 12 Circuit Operation ................................................................................................................................................ 13 trans·nova Implementation ................................................................................................................................. 13 Output Short Protection ....................................................................................................................................... 14 Thermal Protection .............................................................................................................................................. 14 Clipping Indicator ................................................................................................................................................ 15 Signal Present Indicator ....................................................................................................................................... 15 Calibration .......................................................................................................................................................... 15 Bias ..................................................................................................................................................................... 15 Common Mode Rejection .................................................................................................................................... 15 Module Replacement .......................................................................................................................................... 16
INTRODUCTION
The Hafler P1500 and P3000 are two channel professional power amplifiers. Passive cooling with large heatsinks is used for low mechanical noise. Our patented trans·nova circuit topology and MOSFET output stage ensures trouble free, long term operation and is backed by our five year warranty. This manual contains information on using the P1500 and P3000 amplifiers. It is organized into three main sections. "Installation" covers the location and connection of the amplifier in the system. Like many precision components careful attention to the initial setup can yield dividends in higher performance and trouble-free use. "Operation" covers the controls and features of the amplifiers and how to use them to get the best effect. The "Technical Reference" section contains field service information. In addition to the schematic and parts list there are block diagrams and an explanation of circuit operation useful for technicians. We strongly urge reading over the Installation and Operation portions of this manual before putting the amplifier into service. The circuitry used in the P1500 and P3000 is the latest refinement of our trans·nova (TRANSconductance NOdal Voltage Amplifier, US Patent 4,467,288) circuit. It has been proven to offer sound quality to satisfy the most analytic audiophile or the most demanding professional. The natural sound and realistic reproduction have made trans·nova amplifiers preferred in many critical installations. Since our pioneering use of MOSFETs in the DH200 amplifier, they have proven extremely fault tolerant even in abusive situations. This sturdiness enables the amplifier to drive reactive speaker loads without the performance and sound penalties imposed by elaborate protection schemes. Specialized circuits prevent damage to the amplifiers and speakers without affecting the audio signal. A soft start circuit prevents sending potentially destructive turn-on and turn-off transients to the speakers. A thermal sensing network monitors the heatsink temperature and shuts down the amplifier to protect from excessive operating heat. The need for internal fuses has been eliminated; a sensing circuit monitors the output and shuts down operation when it detects a short in the output load. Each channel of these amplifiers is built as a self-contained module which only requires mounting the heatsink and connection to the chassis-mounted transformer and binding posts to be fully functional. The circuit board contains all the operational components. This modular arrangement simplifies construction and improves service accessibility. The circuit board assembly makes extensive use of surface mount components in the low power portion of the audio circuitry. Automated equipment is used to place and solder the components which yields greater uniformity and reliability. The front panel has controls for input level adjustment and the power switch. In addition, LED indicators give a visual representation of the operating status of each channel. The THERMAL and SHORT indicators light to show when these protection circuits have been activated. The CLIP indicator helps prevent damaging the speakers by showing when the amplifier is overdriven. The SIGNAL indicator lights to show the presence of an audio signal.
1
6 3 3
6
P3000
15 0dB 15 0dB
trans nova
channel 2
channel 1
Front Panel View
3
sh o th rt er m cl al ip pi ng sig na l
1
sig na l cl ip p in g th er m a sh l or t
10 1
10
PUSH
2
+
XLR Connections
CAUTION
RISK OF ELECTRIC SHOCK DO NOT OPEN
®
Mono Output: · Use CH 1 Input ONLY · Set CH 2 Gain to Max · Set Output Level with CH 1 Gain Control
1
Phone Connections
2
+
!
WARNING: DO NOT REMOVE COVER
A Division of Rockford Corp. Tempe, AZ 85281 U.S.A. Made in the U.S.A.
Audio Ground Chass. Float
CH 2
Mono 2-Ch 115V ~ 60Hz P3000 250 V T4A
CAUTION: For continued TO REDUCE THE RISK OF FIRE OR ELECTRIC SHOCK DO NOT EXPOSE THIS EQUIPMENT TO RAIN OR MOISTURE. protection from risk of fire, replace only with CH 2 Mono + C H 1 same type and rating of fuse. + 8 + 4-8
CH 1 (Mono)
PUSH
4-8
Rear Panel View
INSTALLATION
LOCATION The P1500 and P3000 power transformer can generate a substantial magnetic field, so caution should be exercised in the placement of low level components such as a tape deck, mixer or mic preamp to avoid inducing noise in the low level circuitry. The amplifiers can also produce considerable heat in normal operation so the primary consideration when determining a location for the amplifiers is to allow for adequate ventilation. The large heatsinks provide unrestricted airflow, but care must be taken to keep the slots in the bottom panel and top cover clear. If the amplifier is mounted in an equipment rack, make sure adjacent equipment does not impede cool air flow.
!
Rack systems should have two fans 4" to 5" in from the front of the amplifier blowing upward.
Inadequate ventilation can shorten component life, especially when other equipment raises the ambient air temperature, so circulating fans should be considered in tight quarters.
4" to 5" (from fan center)
(Bottom View)
Fan center approximately in line with edge of unit and starting of heat sink fins · Fans placed 4" to 5" from front of unit · Fans placed under the unit pointing upwards · Recommended P1500 fan is 32 CFM x 2 · Recommended P3000 fan is 100 CFM x 2
AC LINE The P1500U and P3000U operate from a 120 volt, 60Hz AC power line. The P1500CE and P3000CE operate from a 230 volt, 50-60Hz AC power line. Connection is made by a 16 gauge, IEC Type 320, grounded line cord. For safety considerations only a properly grounded (earthed) receptacle should be used. If a grounded circuit is not available do not break off the ground pin; use the proper adapter plug for a two wire receptacle. Mounted on the rear panel is the line fuse which interrupts the power to the amplifier. If this fuse blows replace it only with the same type and rating fuse. The correct replacement fuse value is printed on the rear panel of the amplifier. If the new fuse blows, this is an indication of a fault with the amplifier. Servicing should be performed only by a qualified technician.
3
INPUT The input jacks located on the back of the amplifier are dual function connectors which accept 1/4" Phone (Tip Ring Sleeve) or XLR plugs. The 1/4" Phone jack is connected according to conventional usage. The XLR jack is connected according to the IEC and AES standard.
XLR Balanced Input
Check output of source unit for proper signal polarity
1/4" TRS Balanced Input
Check output of source unit for proper signal polarity
INPUT Pin 1 = GND Pin 2 = (+) Pin 3 = ()
1 2
GND +
FROM SOURCE Tip = (+) Ring = () Sleeve = GND
INPUT
FROM SOURCE
3
+ SHIELD
Many popular mixers use unbalanced outputs and can be used with the Hafler amplifier. To minimize residual ground noise, we recommend using twisted pair cable or short cable lengths in this type of configuration. XLR Unbalanced Input
Connect () and GND (shield) terminals at both ends of cable to prevent unstable amplifier operation
1/4" TRS Unbalanced Input
INPUT INPUT Pin 1 = GND Pin 2 = (+) Pin 3 = GND FROM SOURCE
SHIELD
FROM SOURCE
1 2
3
Tip = (+) Sleeve = GND
+
+
SHIELD
4
SCHEMATIC DIAGRAM
P3000 shown. Ground switch in Chassis position, Mono switch in 2-Channel position. P1500 differences shown on parts list.
Removable Center Spread
Removable Center Spread
OUTPUT CONNECTIONS The speaker output connectors are dual binding posts. These binding posts will directly accept 12 AWG wire or banana plugs and are spaced on 3/4" centers to accept dual banana plugs. MONOPHONIC USE For systems with high power requirements, the amplifiers can be configured for single channel bridged mono operation. To bridge the amplifier, set the rear panel Mono/2 Channel switch to the Mono position. The Channel 1 input and level control is used and the Channel 2 level control must be set to its maximum gain position. The speaker is connected to the RED output binding posts.
! !
When the amplifier is bridged the output is floating. Any speaker which requires a common ground from the amplifier output cannot be used in this application. Since a bridged amplifier shares the load between the two channels, each channel will effectively drive half of the load. Therefore, for bridged mono operation we recommend using an eight ohm load as the minimum impedance.
OPERATION
POWER SWITCH The POWER switch is located on the front panel of the amplifier. An internal lamp indicates when it is turned on.
!
Standard practice is to turn the amplifier on last and off first when switching components to prevent sending damaging transients to the speakers.
It is possible to leave the power switch in the on position and switch the amplifier remotely through a power distribution block or preamp switched outlet. When doing so make sure the switch is rated for the current required by the amplifier. LEVEL CONTROLS The input sensitivity for each channel can be adjusted individually using the level controls on the front panel. The gain control on an amplifier is usually fully advanced to its maximum (rated) sensitivity. In public systems where it is necessary to match levels, the knobs can be removed and the controls adjusted with your fingers or a flathead screwdriver. Cover the holes with the enclosed plugs to restrict access. MONO SWITCH Conventional two-channel stereo operation is obtained with the MONO/2 CH switch in the 2-Channel position. For high powered single channel use, switch to MONO and use the Channel 1 input and connect the speaker to the RED binding posts.
!
For thermal considerations we do not recommend using less than an eight ohm load on the amplifier when running it in mono.
When the switch is set in the mono position, the Channel 1 (+) and () inputs are connected to the Channel 2 in reversed polarity, which inverts the Channel 2 output. The gain is controlled by the Channel 1 level adjustment; set Channel 2 to maximum.
7
SHORT CIRCUIT PROTECTION Due to the self-protecting properties of the output power MOSFETs, there is no need for sonically degrading voltage and current limiting circuits. To protect the amplifier from problems which may occur in the speaker line there is an overload detection circuit. In the event of a short in the speaker load or cables, the speaker detection circuit will shut down that channel and light the front panel SHORT indicator. If this happens, correct the fault and turn the amplifier off, then back on to reset.
!
LED INDICATORS Amplifier operation is monitored internally and each channel has four status LEDs. These indicators can be used for system troubleshooting in case of aberrant behavior. Signal Clipping Thermal Short Monitors the amplifier output and lights when a signal is present. The SIGNAL indicator is calibrated to activate at an equivalent input voltage of 30mV. Monitors the DRIVE SIGNAL and lights when the drive signal voltage exceeds the maximum for linear operation of the output MOSFETs. Indicates when the thermal protection has shut down the amplifier. This occurs when the heatsink temperature exceeds 90° C. Indicates when the output overload monitor detects a potentially damaging short and shuts down amplifier operation. After clearing the fault, restore normal function by turning the amplifier off, then on again.
WARM UP In order to achieve the best sonic performance from the amplifier, we recommend letting it warm up for 1 hour before beginning any critical listening. The amplifier may not deliver its full potential sound quality before this time has passed. CLEANING AND MAINTENANCE There is no requirement for regular maintenance on the electronic components of the amplifier. If the case becomes soiled it can be cleaned using a soft cloth and a mild detergent, such as spray window or glass cleaner. If the amplifier is located in a particularly dusty environment cleaning the inside with compressed air or vacuuming every 18 to 24 months is sufficient.
8
PC BOARD LAYOUT
C1221 Z3 Z Z2 C121 P4 P2 R165 P1 P3
X4 X3
ROCKFORD CORP PC-0812-H M.ALBERS
C33
R32
SW2
J8 R134 R131
Q9
Q10 R132 R40
Q12 R133
Q11 R138
R130
Q5 R35 C36
J2
Q4 Q116 R34 C124 TS1
J3
Q115
R127
R41
CR12
R141 C116 C115 J4 R140 R136 R21 C126
R164 CR15 R17
R20 R19
C123 C1 R64 R1
C35 C125 R159
CH 1
J1
C114
R31
CR11
R18
C120
C119
R24
C112
R139 C8 R129 C113 Q105 R128 Q6 Q7 Q104 R124 Q103
R33 R14 R39
R7 J7
R9
C19
R6 C22
R10 R16
R48 CR14
JW4 JW5 JW6
Q8 U2 R11 CR4 R53 R49
R58
J5 C21 R61
R8
R123 CR6
CR5
CR13
U4
C29 R12 Q3 CR7
CR8
C31
Q1
R5
R13
R60
C28 CR3
R51 R54
C20
R43
C15 R46
R47
C26
R44 R45 R42
R63
C16
R28
R27
CR9
R15 C23 C17
R38 SW1
R62 R59
C18 Q2
R29
U1
J6
R50
U5
R56
R30
R4
R26
R57
R25
C25
C13
C4
C5
C3
R135
R52
CR2
D1 D2
CT2 AC3
X5
AC4
C24 JW7 AC1 CT1 AC2 C6 C7 R37
C30 CR1
R55
R22
R23
P5P6
X2 X1 JW3
JW2 JW1
ARTWORK COMPONENT SIDE
revised 12/12/96
R36 R2 R3
C14
F3
C9
CR10
F2
C10
C2
9
PARTS LIST
P3000U 120VAC, 60Hz
DESIGNATOR VALUE ALL RESISTORS IN OHMS, 1/4W R1 R2 R3 R4 R5 R6 R7 R8 R9 R10 R11 R12 R13 R14 R15 R16 R17 R18 R19 R20 R21 R22 R23 R24 R25 R26 R27 R28 R29 R30 R31 R32 R33 R34 R35 R36 R37 R38 R39 R40 R41 R42 R43 R44 R45 R46 R47 R48 R49 R50 R51 R52 56.2k 1k 47k 47k 4.7k 1.07k 909 200, Trim Pot 1k 28k 10M 28k 470k 16 3.3M 4.7k 10k 100k 604k 45.3k 2.2M 100k 100k 10k Pot 820 2.2M 316 316 3.92k 3.92k 100 100 16 470 220 1k 1k 3.3M 1k 3k 6.8k 10k 15k 10k 15k 47k 47k 15k 10k 4.7k 4.7k 15k PART # RMP/4-5622 RM/4-102C RM/4-473C RM/4-473C RM/4-472C RM/4-1071C RM/4-9090C RVH-201 RM/4-102C RMP/4-2802 RMP/4-106C RM/4-2802C RM/4-474C RM/4-160C RM/4-335C RM/4-472C RM/4-103C RM/4-104C RM/4-6043C RM/4-4532C RM/4-225C RM/4-104C RM/4-104C RV-0818 RM/4-821C RM/4-225C RM/4-3160C RM/4-3160C RM/4-3921C RM/4-3921C RM/4-101C RM/4-101C RM/4-160C RM/4-471C RM/4-221C RM/4-102C RM/4-102C RM/4-335C RM/4-102C RM/4-302C RM/4-682C RM/4-103C RM/4-153C RM/4-103C RM/4-153C RM/4-473C RM/4-473C RM/4-153C RM/4-103C RM/4-472C RM/4-472C RM/4-153C DESIGNATOR VALUE R53 R54 R55 R56 R57 R58 R59 R61 R62 R63 R64 R123 R124 R127 R128 R129 R130 R131 R132 R133 R134 R135 R136 R138 R139 R140 R141 R159 R164 TS1 SW1 C1 C2 C3 C4 C5 C6 C7 C8 C9 C13 C14 C15 C16 C17 C18 C19 C20 2.2M 10k 100k 15k 10k 100k 10k 100k 2.2M 28k 100k 2k 820 1k 100 100 1k 3k 3k 3k 100 1k 200, Trim Pot 100 470 1k 470 470 220 Thermistor DPDT Switch 680pF, 100V 0.22µF, 50V 6800µF, 80V 0.22µF, 250V 6800µF, 80V 270pF, 50V 270pF, 50V 4.7pF, 100V 0.1µF, 50V 470µF, 50V 470µF, 50V 0.1µF, 50V 0.1µF, 50V 0.1µF, 50V 0.1µF, 50V 0.1µF, 50V 0.1µF, 50V PART # RM/4-225C RM/4-103C RM/4-104C RM/4-153C RM/4-103C RM/4-104C RM/4-103C RM/4-104C RM/4-225C RM/4-2802C RM/4-104C RM/4-202C RM/4-821C RM/4-102C RM/4-101C RM/4-101C RM/4-102C RM/4-302C RM/4-302C RM/4-302C RM/4-101C RM/4-102C RVH-201 RM/4-101C RM/4-471C RM/4-102C RM/4-471C RM/4-471C RM/4-221C SS-1519-A SW-0280 CDS-681DBAA CYV-224 CERS-688D CY-224AC CERS-688D CDS-271CAAA CDS-271CAAA CDS-047DBAA CDS-104CCDB CER-477C-024 CER-477C-024 CDS-104CCDB CDS-104CCDB CDS-104CCDB CDS-104CCDB CDS-104CCDB CDS-104CCDB
10
DESIGNATOR C21 C22 C23 C24 C25 C26 C28 C29 C30 C31 C33 C35 C36 C112 C113 C114 C115 C116 C119 C120 Q1 Q2 Q3 Q4 Q5 Q6 Q7 Q8 Q9 Q10 Q11 Q12 Q103 Q104 Q105 Q115 Q116 CR1 CR2 CR3 CR4 CR5 CR6 CR7 CR8 CR9 CR10 CR11 CR12 CR13
VALUE 10µF, 16V 10µF, 16V 0.47µF, 50V 0.47µF, 50V 0.1µF, 50V 1µF, 50V 47µF, 16V 10µF, 50V 0.1µF, 50V 0.1µF, 50V 0.1µF, 50V 47pF, 200V 22pF, 200V 100µF, 25V 100µF, 25V 100pF, 50V 100pF, 50V 0.047µF, 50V 0.1µF, 100V 0.1µF, 100V MMBT3904LT1 LM-317 LM-337 2SK1058 2SJ162 MMBT5088L MMBT5088L MMBT3904LT1 MPS-A56 MPS-A56 MPS-A06 MPS-A06 MMBTA06L MMBT3906LT1 MMBT3906LT1 2SK1058 2SJ162 Red LED Red LED Red LED Green LED MMBD914L Diode MMBD914L Diode MMBD914L Diode MMBD914L Diode Bridge Rectifier 15A Bridge Rectifier 1.5A BAV99L Dual Diode BAV99L Dual Diode MMBD914L Diode
PART # CER-106SM CER-106SM CYV-474 CYV-474 CDS-104CCDB CER-105C-024 CER-476-024 CER-106C-024 CDS-104CCDB CDS-104CABB CDS-104CCDB CM-470-024 CM-200-024 CER-107A-024 CER-107A-024 CDS-101CAAA CDS-101CAAA CYV-473 CY-104 CY-104 SS-0792 SS-239 SS-240 SSH-741T SSH-740T SS-0114 SS-0114 SSS-0792 SS-101A SS-101A SS-102A SS-102A SS-102SM SS-0791 SS-0791 SSH-741T SSH-740T SS-741 SS-741 SS-741 SS-740 SS-803SM SS-803SM SS-803SM SS-803SM SS-0801 SS-0800 SS-260SM SS-260SM SS-803SM
DESIGNATOR VALUE CR14 BAV99L Dual Diode CR15 BAV99L Dual Diode U1 U2 U4 U5 TL072CD Dual Opamp TL072CD Dual Opamp LM339 Comparator LM339 Comparator Power Switch IEC Connector IEC Line Cord Dual Binding Post P3000 Transformer Fuse, 1A Fast Fuse, 1A Fast Fuse, 5A Slo Blo
PART # SS-260SM SS-260SM SS-143SM SS-143SM SS-730SM SS-730SM SWH-1009 CC-0852 FAH-146 CC-0867 TT-1531 FS-1592 PS-1592 FS-005SB
! !
!
F2 F3 Line Fuse
!
! !
Parts List Modifications for P1500CE
European Linecord FA-1464 Fuseholder Cup 5x20mm FS-1125 1.25A Slo Blo 5x20mm FS-1474A 230V Transformer TT-1457B
! ! ! !
Parts List Modifications for P3000CE
! !
European Linecord FA-1464 Fuseholder Cup 5x20mm FS-1125 2.5A Slo Blo 5x20mm FS-1541A 230V Transformer TT-1532B
! ! ! !
C5 C35, 36 CR9 Q5, Q115 Line Fuse
Parts List Modifications for P1500U 120VAC, 60Hz Parts List Modifications for C3 3300µF, 63V CERS-338E P1500U 120VAC, 60Hz
3300µF 63V Not Used Bridge Rectifier, 8A Not Used P1500 Transformer Fuse, 4A Slo Blo CERS-338E SS-0799 TT-1456 FS-004SB
! ! !
! !
!
Components marked with this symbol are safety critical and should only be replaced with identical components. Los componentes marcados con el simbolo son ! imprescindibles para la protección del equipo, por lo cual que solo sean reemplazados por los mismos componentes. Les componsants marqués du symbole ! sont indispensables à la sécuritée et ne peuvent être remplacés qu'avec des composants identiques. Bauteile, die mit einem ! gekenzeichnet sind, sind sehr wichtig und dürfen nur mit den orginal Ersatzteilen ausgetauscht werden. I componenti contrassegnati da ! sono critici per la sicurezza e devono essere rimpiazzati solo con ricambi di valore identico.
!
!
!
!
!
11
If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Diplodocs provides you a fast and easy access to the user manual HAFLER P1500. HAFLER offer a product for which we do not have the user manual? Let us know what you are looking for: site Internet, histoire, actualité, filiales, site Internet, mode d'emploi, driver, avis des utilisateurs, meilleur prix des produits, forum d'assistance aux problèmes, annuaire des marques, annuaire des constructeurs, répertoire des marques, répertoire des constructeurs, site Internet de la marque, site Internet du constructeur Diplodocs allows you to download user manual HAFLER P1500, user guide HAFLER P1500, instructions HAFLER P1500, owner's manual HAFLER P1500, online manual HAFLER P1500.Access web reviews HAFLER P1500, , DVD Player, DVD Recorder, Home Theater, Amplifier & Hi-Fi Audio. |
![]() |
Include the add-on to download manuals from your site, forum or blog | ![]() |
Frequently Asked Questions | ![]() |
Contact Diplodocs team | ![]() |
Last searches Last additions |
![]() |
Sitemap | ![]() |
|||
| Brands starting with A B C D E F G H I J K L M N O P Q R S T U V W X Y Z # | |||||||||||||
|
|
Copyright © 2005 - 2008 - Diplodocs -
All Rights Reserved. Designated trademarks and brands are the property of their respective owners. |