9 562 brands
2 694 000 user's guides


Download your manual, it's FREE! Diplodocs allows you to download several types of document in order to best use your HANNA INSTRUMENTS C 102 : user manual, user guide, instruction manual.
Search a brand
Advanced Search

User manual HANNA INSTRUMENTS C 102

Diplodocs help download the user guide HANNA INSTRUMENTS C 102 .

Download the complete user guide (3492 Ko)





Preview of the first 3 pages of manual

You either have JavaScript turned off or an old version of Adobe Flash Player
Get the latest Flash Player.
Manual abstract: user guide HANNA INSTRUMENTS C 102

Detailed instructions for use are in the User's Guide.

Instruction Manual C 102 Multiparameter Turbidity & Ion Specific Meter This Instrument is in Compliance with the CE Directives www.hannainst.com Dear Customer, Thank you for choosing a Hanna Product. Please read this instruction manual carefully before using the instrument. This manual will provide you with the necessary information for the correct use of the instrument, as well as a precise idea of its versatility. If you need more technical information, do not hesitate to e-mail us at tech@hannainst.com. This instrument is in compliance with tives. direc- PRELIMINARY EXAMINATION Remove the instrument from the packing material and examine it to make sure that no damage has occurred during shipping. If there is any damage, notify your Dealer. C102 is supplied complete with: · 1.5V AA Size Batteries (4 ea.) · Glass Cuvet · Cap In addition to the above items, an optional starter kit HI 731327 is available, supplied with: · Measurement cuvets (2 pcs) · Primary calibration standards: HI 93102-0 AMCO-AEPA-1 0 NTU* calibration solution, 30 mL HI 93102-20 AMCO-AEPA-1 20 NTU* calibration solution, 30 mL · HI 93703-50 Cleaning solution, 230 mL · HI 731318 Tissue for wiping the cuvets (4 pcs) · HI 710031 Rugged carrying case Note: Save all packing material until you are sure that the instrument functions correctly. Any defective item must be returned in its original packaging with the supplied accessories. TABLE OF CONTENTS General Description .................................... 4 Principle of Operation .................................. 6 Functional Description ................................. 9 Specifications ........................................... 13 Operational Guide ..................................... 14 Calibration ................................................. 22 Diagnostic mode ....................................... 30 Logging with C 102 .................................... 31 User-selectable Shutdown ......................... 33 Battery Replacement ................................ 34 Diagnostic Codes ...................................... 35 Accessories .............................................. 36 Warranty ................................................... 38 CE Declaration of Conformity .................... 39 * 1 NTU (Nephelometric Turbidity Unit) = 1 FTU (Formazine Turbidity Unit) 2 3 GENERAL DESCRIPTION The Hanna C 102 is a portable microprocessor driven, multiparameter, turbidity and ion specific meter. It measures Free & Total Chlorine, Cyanuric Acid, pH, Iodine, Bromine, Low Range Iron and Turbidity. In the colorimetric mode, the user can select either factory preprogrammed calibration settings or calibrate the meter using customized calibration values based on the concentration or relative absorbance of the sample. Calibration data is also stored in a non-volatile EEPROM. In the turbidity mode, periodic recalibration of the meter with primary standards according to regulatory requirements or personal experience is suggested. Turbidity ranges are 0.009.99 NTU and 10.0-50.0 NTU. C 102 complies with G.L.P. Standards (Good Laboratory Practice), that is: · When switched on, the LCD displays all segments (display check). · Battery status is monitored during every measurement cycle warning the user if the batteries become weak. In addition, C102 will turn itself off before low voltage causes erroneous readings. · It utilizes a real time clock and recalls calibration data such as date, time and calibration values. To facilitate field tests, the meter provides a logging mode. In this mode, the user can store up to twenty five time-tagged measurements in RAM and scroll the memory at any time. There are eight keys for the different operationals modes. The large Liquid Crystal Display is dual-level: the upper level has four digits and can display the measured parameter in hundredths. The lower level has three characters and indicates current mode (e.g. F CL for free chlorine or TR for turbidity). Different LCD segments indicate low battery, logging mode, date, time, etc. A pure Green LED has been utilized as a light source for both turbidimetric and colorimetric measurements. A silicon photocell is used to receive transmitted light from colorimetric channel while another photocell receives scattered light from the turbidimetric (nephelometric) channel. In order to measure colorimetric parameters, all the operator has to do is zero the blank sample and then add 1 packet of reagent (for Bromine, Chlorine, Cyanuric Acid, Iodine and Low Range Iron) or 0.2 mL of Phenol Red (for pH). After placing the cuvet back in the meter and pressing READ, the measurements are shown directly on the LCD. The instrument operates with four AA batteries and may be operator-programmed to turn itself off automatically after 10, 20, 30, 40, 50 or 60 minutes of inactivity. C 102 and all accessories such as sample vials, reagent pillows, primary standards, can be easily stored in the optional carrying case (HI 710031). 4 5 In Progress". The upper level also indicates the concentration or turbidity of the sample, as well as different diagnostic modes, such as "-BA-" for low battery. 2) Secondary LCD: The three-digit LCD shows the current mode of measurement that is "F CL", "t CL", "CY", "PH", "Id", "Br", "L FE", "tr", and diagnostic or calibration modes, such as "d 11", "2 Fn", "5 c1". Indicates that the upper level of LCD is showing the current date, the date of last calibration or the date of logged measurement in memory. Indicates that the upper level of LCD is showing the current time, the time of last calibration or the time of logged measurement in memory. Blinking segment warns user of low battery voltage. If intermittent, it indicates that the user is in the scroll mode viewing the logged measurements. If fixed, it indicates that the meter is in the log mode and every reading taken will be stored in memory. 10 7) ON/OFF key: 8) ZERO / Turns the meter on and off. key: In ion specific (colorimetric) mode, it zeros the sample. In calibration and diagnostic modes, it functions as ENTER (not used in turbidity mode). key: Takes the measuremnt of concentration/turbidity of the sample which is shown on the LCD. In diagnostic or calibration mode, shifts the flashing digit to the right. If pressed during calibration, the calibration procedure will be aborted and the last calibration data will be reinstated. If pressed together with the ALT key for less then 3 seconds, the diagnostic mode will be entered. If pressed together with the ALT key again, the meter will quit diagnostic mode. If pressed for more then 3 seconds, an intermittent "CAL" prompt will appear on the upper LCD level and the calibration procedure is entered. 9) READ / 3) DATE: 10) CAL key: 4) TIME: 5) LOBAT: 6) LOG: 11) GLP/Abs key: In ion specific mode, it will toggle concentration/absorbance readings on the upper LCD. In turbidity mode, date, time and the two calibration values of the current mode will be 11 shown. If pressed in time/date setup mode, the meter will quit current mode without making any changes to current time/ date. 12) key Scrolls upwards through the parameters to be measured. In calibration/diagnostic mode, increments the blinking digit by one. If pressed together with ALT while the meter is in logging mode, the upper LCD will show the data (date/time/value) in the memory. Alternative functions. Scrolls downwards through the parameters to be measured. In calibration/diagnostic mode, decreases the blinking digit by one. If pressed together with ALT while the meter is in logging mode, the upper LCD will show the current lot number. SPECIFICATIONS C 102 Range Turbidity Bromine Free Cl Total Cl CYS Iodine LR Iron pH Resolution Turbidity Bromine Free Cl Total Cl CYS Iodine LR Iron pH 0.00 to 50.0 NTU* 0.00 to 8.00 mg/L 0.00 to 2.50 mg/L 0.00 to 3.50 mg/L 0 to 80 mg/L 0.0 to 12.5 mg/L 0.00 to 1.00 mg/L 5.9 to 8.5 0.01 and 0.1 NTU* 0.01 mg/L 0.01 mg/L 0.01 mg/L 1 mg/L 0.1 mg/L 0.01 mg/L 0.1 13) ALT key: 14) key: Accuracy Turbidity ±0.5 NTU* or ±5% (whichever greater) Bromine ±0.08 mg/L; ±3% Free Cl ±0.03 mg/L; ±3% Total Cl ±0.03 mg/L; ±3% CYS ±1 mg/L; ±15% Iodine ±0.1 mg/L; ±5% LR Iron ±0.02 mg/L; ±3% pH 0.1 pH Light Source Light Source Life Light Detector Power Source Battery Life Automatic Shutdown Operating Conditions Dimensions Weight Pure Green LED Life of the instrument Two Silicon Photocells 4 x 1.5V AA alkaline batteries 60 hours or 1000 measurements Selectable 10, 20, 30, 40, 50 or 60 min. 0 to 50°C (32 to 122°F) 95% RH max (non-condensing) 220 x 82 x 66 mm (8.7 x 3.2 x 2.6") 510 g (18 oz.) 12 13 * 1 NTU = 1 FTU OPERATIONAL GUIDE CURRENT TIME/DATE RECALL To recall current TIME/DATE press and hold the ALTand READ keys together. The current time and an intermittent "TIME" will be displayed. SET CURRENT TIME/DATE To set or change the current time, turn on the meter. After initialization routine, the LCD will show: + Release the keys. Press and hold the ALT and READ keys again and the meter will show the current date together with an intermittent "DATE". Press and hold the ALT and GLP keys together. Display will show the current date in MM.DD format (e.g. August 28 is shown as 08.28). + TURBIDITY MEASUREMENTS Fill the vial with the sample. The surface of the vial should be clean and scratch free. Turn the meter on. After the initialization routine, the LCD will show: + Release the keys. The month digits will blink. Make the necessary adjustments with the and keys. To skip to the day digits, press the key. After the adjustments, press the key. The unit will store the newly set month-day data in its EEPROM and will show the current time by a 24 hour clock HH.MM format, e.g. 2:28 pm is: Use the and keys to set the lower level of the LCD to turbidity (tr). Similarly, make the necessary adjustments as described above and press . The newly set up "month - day - hour - minute" data will be stored in memory. 14 Insert the sample into the cuvet holder and ensure that the notch on the cap is positioned securely into the groove. 15 Press READ. The meter will intermittently display "SIP" on the upper level of the LCD. The meter will show "SIP" for a few seconds and then a zero indication: After a few seconds the display will show the turbidity value, e.g. 5.34 NTU: For pH, add 0.2 mL of HI 93710-01: For Chlorine, Iodine and Bromine, add the content of their respective packet: 1x COLORIMETRIC MEASUREMENTS Turn the meter on. After the initialization routine, the LCD will display: Use the and keys to choose the desired parameter: F CL CY Id L FE Free Chlorine Cyanuric Acid Iodine Iron t CL Total Chlorine PH pH Br Bromine For Cianuric Acid only, add the content of one packet of HI 93722 reagent to a beaker filled up to the 25mL mark with unreacted sample up to the 25 mL mark. Stir gently to mix and then fill the cuvet up to 1.5 cm (¾") below the rim with 10 mL of the reacted sample. 1.5 cm Measuring Chlorine, Cyanuric Acid, pH, Iodine, Bromine Fill the vial with the sample (blank). The surface of the vial should be clean and scratch free. Insert the blank sample into the cuvet holder and ensure that the notch on the cap is positioned securely into the groove. Press ZERO. Replace the cap, shake the cuvet and allow a few seconds for color to develop. For best results, wait 2½ mins. for Total Chlorine, Bromine, Iodine, and 45 secs. for Cyanuric Acid. Insert the reacted sample into the cuvet holder and ensure that the notch on the cap is positioned securely into the groove. Press READ. The meter will show "SIP" for a few seconds and then the concentration: 16 17 Measuring Iron Fill one graduated mixing cylinder up to the 25 mL mark with deionized water. Add the content of one packet of HI 93746 TPTZ reagent, close the cylinder and agitate for 30 seconds. This is the blank. 12 9 Add the content of one packet of HI 93746 TPTZ reagent, close the cylinder and agitate for 30 seconds. 30" 3 6 12 9 30" 3 6 Fill a cuvet with 10 mL of the blank up to 1.5 cm (¾") below the rim and replace the cap. 1.5 cm Fill a cuvet with 10 mL of the reacted sample up to 1.5 cm (¾") below the rim and replace the cap. This is the sample. 1.5 cm Insert the blank into the cuvet holder and make sure that the notch on the cap is positioned securely into the groove. Press ZERO. Insert the reacted sample into the cuvet holder and make sure that the notch on the cap is positioned securely into the groove. Wait 30" and then press READ. The meter will show "SIP" for a few seconds and then a zero indication: The meter will show "SIP" for about a few seconds and then the concentration: Fill one graduated mixing cylinder up to the 25 mL mark with the sample. Note: To review the relative absorbance of the sample, wait until the concentration measurement is completed, and then press GLP/Abs. The display will show the absorbance in milliunits to ...

  Know our Partners   Frequently Asked Questions   Contact Diplodocs team   Last searches
Latest additions
  Sitemap
Brands starting with A B C D E F G H I J K L M N O P Q R S T U V W X Y Z #
Copyright © 2005 - 2008 - Diplodocs - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.