9 562 brands
2 694 000 user's guides


Download your manual, it's FREE! Diplodocs allows you to download several types of document in order to best use your HANNA INSTRUMENTS HI 8510 : user manual, user guide, instruction manual.
Search a brand
Advanced Search

User manual HANNA INSTRUMENTS HI 8510

Diplodocs help download the user guide HANNA INSTRUMENTS HI 8510 .

Download the complete user guide (450 Ko)





Preview of the first 3 pages of manual

You either have JavaScript turned off or an old version of Adobe Flash Player
Get the latest Flash Player.
Manual abstract: user guide HANNA INSTRUMENTS HI 8510

Detailed instructions for use are in the User's Guide.

Instruction Manual HI 8510 - HI 8512 HI 8710 - HI 8711 HI 8720 - HI 931500 HI 931501 - HI 932500 Panel - Mounted ORP - pH Indicators and Controllers ORP HI 8720E mV DOSAGE OXID. REDUC. SLOPE AL MEA SURE SET COARSE SET FINE AL 0 mV TEST 500 mV TEST These Instruments are in Compliance with the CE Directives http://www.hannainst.com 1 Dear Customer, Thank you for choosing a Hanna Instruments Product. Please read this instruction manual carefully before using the instrument. This manual will provide you with all the necessary information for the correct use of the instrument, as well as a precise idea of its versatility in a wide range of applications. These instruments are in compliance with directives. TABLE OF CONTENTS Preliminary Examination ............................. 3 General Description ..................................... 3 Mechanical Dimensions .............................. 5 Functional Description HI 8510 .................... 6 Functional Description HI 8512 .................... 9 Functional Description HI 8710 .................. 12 Functional Description HI 8711 .................. 16 Functional Description HI 8720 .................. 20 Functional Description HI 931500 .............. 24 Functional Description HI 931501 .............. 26 Functional Description HI 932500 .............. 29 Specifications HI 8510 and HI 8512 ........... 31 Specifications HI 8710 and HI 8711 ........... 32 Specifications HI 8720 and HI 931500 ....... 33 Specifications HI 931501 and HI 932500 .... 34 Initial Preparation ...................................... 35 Operational Guide ..................................... 38 pH Calibration ........................................... 42 pH Values at Various Temperature ............. 44 pH Diagnostic Tests .................................. 45 ORP Diagnostic Tests ............................... 47 LED Indication ........................................... 48 Taking Redox Measurements .................... 49 Electrode Conditioning and Maintenance ... 50 Suggested Installations ............................. 57 Accessories .............................................. 59 Warranty ................................................... 65 CE Declaration of Conformity .................... 66 2 PRELIMINARY EXAMINATION Remove the instrument from the packing material and examine it carefully to make sure that no damage has occurred during shipping. If there is any noticeable damage, notify your Dealer. Note: Save all packing materials until you are sure that the instrument functions correctly. All defective items must be returned in the original packing materials together with the supplied accessories. GENERAL DESCRIPTION HI 8510, HI 8512, HI 8710, HI 8711, HI 8720, HI 931500, HI 931501 and HI 932500 are pHORP panel-mounted indicators and controllers designed for simplicity of use in a wide range of industrial process applications. The models are designed with DIN standard panel mount with membrane keypads on the front panel, a large LCD display and autodiagnostic functions (not HI 931500, HI 931501 and HI 932500). Connections to the power supply, contacts and recorders are made through screw terminals on the rear panel. Two models are available for HI 8510, HI 8711, HI 8512, HI 8520. The E-model accepts input direct from the pH or ORP electrode, while the T-model accepts a 2-wire current loop of 4 to 20 mA from a pH or ORP transmitter. HI 931500, HI 931501 and HI 932500 are equipped with a BNC socket to connect a pH-ORP electrode. Other features include: recorder output in 0 to 20 mA or 4 to 20 mA; LED indicators which identify the controller mode. 3 Using the pH indicators in conjunction with a 4-20mA output pH transmitter HI 8614 or HI 8614L (with LCD display) and using the ORP indicators in conjunction with a 4-20 mA output ORP transmitter HI 8615 or HI 8615L (with LCD display) will assure you of a strong, interference-free signal at distances up to 300 m (1000 ft). All instruments are supplied with a plastic transparent front cover and mounting brackets (electrode and mains cable excluded). 4 MECHANICAL DIMENSIONS The meters have a DIN 43 700 casing in black anodized aluminum. Front and back of the instruments are supplied with shockproof ABS plastic and a transparent protective cover for the front panel. Front view of the panel-mounted unit. 141mm 5.55" 144mm 5.67" 69mm 2.71" 72mm 2.83" These dimensions show the cutout size for the installation. Side view of the panel-mounted unit. 0.25/4mm 0.01/0.160" ADJUSTABLE LOCATION BRACKET 144mm 5.67" 135mm 5.31" 190mm MIN 7.50" Adjustable location brackets (supplied with the meter) allow the indicator to slide into the cutout and will hold the unit securely in place. 190 mm (7.50") is the minimum amount of room required to install the indicator with the cables connected. 5 FUNCTIONAL DESCRIPTION HI 8510 pH INDICATOR FRONT PANEL pH HI 8510E pH SLOPE SENSOR TEST pH 7 TEST pH 4 TEST Keypad SENSOR TEST To display the mV response of the electrode in order to verify its working condition pH 7 TEST To verify the internal circuit of the meter in terms of Offset compensation pH 4 TEST To verify the amplifier circuit of the meter Trimmers For Offset calibration O SLOPE For Slope calibration 6 REAR PANEL HI 8510E 5 ELECTRODE INPUT 4 3 PT100 + mA OUT - FUSE 1 FUSE 2 220 110 L 1. Fuse Holder 2. Power supply 3. Recorder output 4. Connections for PT100 temperature sensor 5. BNC socket for pH electrode. Unplug the instrument from the power supply before replacing the fuse. 7 REAR PANEL HI 8510T 1. Fuse Holder 2. Power supply 3. Recorder output 4. Connections to the transmitter. Unplug the instrument from the power supply before replacing the fuse. 8 FUNCTIONAL DESCRIPTION HI 8512 ORP INDICATOR FRONT PANEL ORP HI 8512E mV SLOPE 0 mV TEST 500 mV TEST Keypad 0 mV TEST To verify the instrument calibration at point 0 500 mV TEST To verify the slope at point 500 mV Trimmers SLOPE For Slope calibration 9 REAR PANEL HI 8512E 4 ELECTRODE INPUT 3 + mA OUT - FUSE FUSE 1 2 220 110 L 1. Fuse Holder 2. Power supply 3. Recorder output 4. BNC socket for ORP electrode. Unplug the instrument from the power supply before replacing the fuse. 10 REAR PANEL HI 8512T 1. Fuse Holder 2. Power supply 3. Recorder output 4. Connections to the transmitter. Unplug the instrument from the power supply before replacing the fuse. 11 FUNCTIONAL DESCRIPTION HI 8710 pH CONTROLLER WITH ALARM FRONT PANEL pH HI 8710E pH SLOPE ACID BASE 0 AL SET MEA SURE COARSE SENSOR TEST AL SET FINE pH 7 TEST pH 4 TEST To set the working point of pH dosage MEASURE To set HI 8710 on measurement mode and to enable the diagnostic tests SENSOR TEST To display the mV response of the electrode in order to verify its working condition To display and set the toler AL ance of the alarm points pH 7 TEST To verify the internal circuit of the meter in terms of Offset compensation pH 4 TEST To verify the amplifier circuit of the meter 12 Keypad SET Trimmers O SLOPE AL For Offset calibration For Slope calibration To set the tolerance of the alarm SET/COARSE To coarsely adjust the set point SET/FINE To finely adjust the set point Leds ACID To show the acid dosage is active BASE To show the basic dosage is active AL (blinking) To show the alarm is active 13 REAR PANEL HI 8710E 9 ELECTRODE INPUT 8 7 3 PT100 + mA OUT OPEN: ACID SHORT: BASE 5 4 6 2 SET CONSENT FUSE ALARM 1 FUSE 1. Fuse Holder 2. Power supply 3. Acid/Basic dosage selection 4. Reductant or oxidant dosage consent 5. Connections for dosing pump 6. Alarm contacts 7. Recorder output 8. Connections for PT100 temperature sensor 9. BNC socket for pH electrode. Unplug the instrument from the power supply before replacing the fuse. 14 220 110 L REAR PANEL HI 8710T 1. Fuse Holder 2. Power supply 3. Acid/Basic dosage selection 4. Reductant or oxidant dosage consent 5. Connections for dosing pump 6. Alarm contacts 7. Recorder output 8. Connections to the transmitter. Unplug the instrument from the power supply before replacing the fuse. 15 FUNCTIONAL DESCRIPTION HI 8711 DUAL OUTPUT pH CONTROLLER FRONT PANEL pH HI 8711E pH SLOPE ACID SET BASE SET AL MEA SURE COARSE ACID SET SENSOR TEST AL FINE COARSE pH 7 TEST HI 8711E pH 4 TEST BASE SET FINE Keypad ACID SET BASE SET MEASURE SENSOR TEST Al To set the working point of acid dosage To set the working point of basic dosage To set HI 8711 on measurement mode and to enable the diagnostic tests To display the mV response of the electrode to verify its working condition. To display and to set the tolerance of the alarm points 16 pH 7 TEST pH 4 TEST To verify the internal circuit of the meter in terms of Offset compensation To verify the amplifier circuit of the meter Trimmers O SLOPE AL For Offset calibration For Slope calibration To set the tolerance of the alarm ACID SET/COARSE To coarsely adjust the acid set point ACID SET/FINE To finely adjust the acid set point BASE SET/COARSE To coarsely adjust the basic set point BASE SET/FINE To finely adjust the basic set point Leds ACID SET (Blinking) To show the acid dosage is active BASE SET (Blinking) To show the basic dosage is active To show the alarm is AL (Blinking) active 17 REAR PANEL HI 8711E 8 ELECTRODE INPUT 7 6 PT100 + mA OUT - 4 3 5 2 BASE ACID FUSE ALARM 1 FUSE 1. Fuse Holder 2. Power supply 3. Connections for dosing pump for acid 4. Connections for dosing pump for base 5. Alarm contacts 6. Recorder output 7. Connections for PT100 temperature sensor 8. BNC socket for pH electrode. Unplug the instrument from the power supply before replacing the fuse. 18 220 110 L REAR PANEL HI 8711T 1. Fuse Holder 2. Power supply 3. Connections for dosing pump for acid 4. Connections for dosing pump for base 5. Alarm contacts 6. Recorder output 7. Connections to the transmitter. Unplug the instrument from the power supply before replacing the fuse. 19 FUNCTIONAL DESCRIPTION HI 8720 ORP CONTROLLER FRONT PANEL ORP HI 8720E mV DOSAGE OXID. REDUC. SLOPE AL MEA SURE SET COARSE SET FINE AL 0 mV TEST 500 mV TEST To set the working point of ORP dosage MEASURE To set HI 8720 on measurement mode and to enable the diagnostic tests To display and to set the toler Al ance of the alarm points 0 mV TEST To verify the instrument calibration at point 0 500 mV TEST To verify the slope at point 500 mV 20 Keypad SET ...

  Know our Partners   Frequently Asked Questions   Contact Diplodocs team   Last searches
Latest additions
  Sitemap
Brands starting with A B C D E F G H I J K L M N O P Q R S T U V W X Y Z #
Copyright © 2005 - 2008 - Diplodocs - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.