9 562 brands
2 694 000 user's guides


Download your manual, it's FREE! Diplodocs allows you to download several types of document in order to best use your HANNA INSTRUMENTS HI 8564 : user manual, user guide, instruction manual.
Search a brand
Advanced Search

User manual HANNA INSTRUMENTS HI 8564

Diplodocs help download the user guide HANNA INSTRUMENTS HI 8564 .

Download the complete user guide (178 Ko)





Preview of the first 3 pages of manual

You either have JavaScript turned off or an old version of Adobe Flash Player
Get the latest Flash Player.
Manual abstract: user guide HANNA INSTRUMENTS HI 8564

Detailed instructions for use are in the User's Guide.

Instruction Manual HI8564 HI 93640 Portable Thermo-Hygrometers % ins ru me n s % ins rum HI 85 64 therm o hygrom eter en s THER MOHY GROM ETER RANG E: RH% 5 to 95 ºC 0 to ºF 32 to 60 140 ON OFF RH% ºF RH% ºC ºF RAN GES 10 ... 0 ... 95 32 ... 60 140 HI936 ºC 40 Manufacturers since 1978 These Instruments are in Compliance with the CE Directives Dear Customer, Thank you for choosing a Hanna Instruments Product. Please read this instruction manual carefully before using the instrument. This manual will provide you with all the necessary information for the correct use of the instrument, as well as a precise idea of its versatility in a wide range of applications. These instruments are in compliance with directives. PRELIMINARY EXAMINATION Remove the instrument from the packing material and examine it to make sure that no damage has occurred during shipping. If there is any damage, notify your Dealer. Note: Save all packing material until you are sure that the instrument functions correctly. All defective items must be returned in the original packing with the supplied accessories. TABLE OF CONTENTS Preliminary Examination ........................... 1 General Description .................................. 1 Functional Description of HI 8564 ............. 2 Functional Description of HI 93640 ........... 3 Specifications of HI 8564 .......................... 4 Specifications of HI 93640 ........................ 5 Operational Guide ..................................... 6 Calibration ................................................. 8 Battery Replacement .............................. 12 Shockproof Rubber Boots ....................... 13 Accessories ............................................ 14 Warranty ................................................. 15 CE Declaration of Conformity ................. 17 GENERAL DESCRIPTION HI 8564 and HI 93640 portable Thermo-Hygrometers measure both Temperature and Relative Humidity. HI 93640 is a compact, easy to carry meter with a convenient wrist-wrap. The built-in thin film capacitance sensor assures accurate humidity measurements from 5.0 to 95.0% RH with a resolution of 0.1%. The RH probe contains both the sensor and the electronic circuitry necessary to amplify the RH as well as the temperature readings. Another electronic circuit converts the amplified signal into a digital readout in % Relative Humidity. Note: The RH probe sensor must never come into contact with water or other liquids. HI 8564 comes supplied with: HI 70601/2, detachable relative Humidity probe and a 9V battery. HI 93640 comes supplied with a 9V battery. 1 FUNCTIONAL DESCRIPTION OF HI 8564 FUNCTIONAL DESCRIPTION OF HI93640 1 2 7 °C H 1 2 3 ins rum n s V 8 9 10 11 12 °C ins rum n s e 3 4 5 H THERMOHYGROMETER ON OFF RANGE: RH% 5 to 95 °C 0 to 60 °F 32 to 140 e V HI 8564 thermo hygrometer RH% ON OFF 4 5 6 7 6 °F R ANGE S °C RH% 13 RH% 10 °C 0 °F 32 .... .... .... 95 60 140 °F °C HI93640 1) DIN socket for Relative Humidity/Temp. Probe 2) Liquid Crystal Display 3) ON/OFF Key (to turn the meter on or off) 4) RH% Key (to display RH measurements) 5) 6) O O F Key (to display Temperature in Fahrenheit) C Key (to display Temperature in Centigrade) 1) Detachable filter cap (HI 936CAP) 2) Built-in RH/Temp. probe 3) Liquid Crystal Display 4) ON/OFF Key (to switch on/off) 5) RH% Key (to display RH measurements) 6) 7) O O 7) Shielded Cable 8) Low RH Trimmer 9) Low Temperature Trimmer 10) High RH Trimmer 11) High Temperature Trimmer 12) Polypropylene Probe Body 13) Protective Cover (to prevent damage to sensor) Display Indicators: "OC" (to indicate Temperature readings in degrees Centigrade) "H" (to indicate Relative Humidity readings) "V" (to indicate that battery needs to be replaced) F Key (to display Temperature in Fahrenheit) C Key (to display Temperature in Centigrade) Display Indicators: "OC" (to indicate Temperature readings in degrees Centigrade) "H" (to indicate Relative Humidity readings) "V" (to indicate that battery needs to be replaced) 2 3 SPECIFICATIONS OF HI 8564 SPECIFICATIONS OF HI 93640 RANGE RH °C °F 10.0 to 95.0% 0.0 to 60.0 32 to 140 RANGE RH °C °F 5.0 to 95.0% 0.0 to 60.0 32 to 140 RESOLUTION RH °C °F ACCURACY (@20°C / 68°F) RH °C °F 0.1% 0.1 1 RESOLUTION RH °C °F ACCURACY (@20°C / 68°F) RH °C °F 0.1% 0.1 1 +2% +0.4 +1 for one year, excluding probe error +2% +0.4 +1 for one year excluding probe error TYPICAL EMC DEVIATION RH °C °F OPERATING CONDITIONS BATTERY +2% +0.5 +1 0 to 50 oC (32 to 122 oF) 98% RH max. One 9V, 100 hours of continuous use, with low battery indicator TYPICAL EMC DEVIATION RH °C °F OPERATING CONDITIONS BATTERY ±3% ±0.4 ±0.8 0 to 50oC (32 to 122oF) 98% RH max. One 9V, 100 hours of continuous use, with low battery indicator 190 x 80 x 38 mm (7.5 x 3.1 x 1.5") 320 g (11.3 oz.) DIMENSIONS Meter Probe 185 x 82 x 45 mm (7.3" x 3.2" x 1.8") L:165 mm D:25 mm with 2 m cable (L:6.5" D:1" 7' cable) DIMENSIONS WEIGHT WEIGHT Meter Probe 315 g (11.1 oz.) 200 g (7 oz.) 4 5 OPERATIONAL GUIDE INSTRUMENT PREPARATION Each meter is supplied complete with a 9V battery. Slide off the battery compartment cover on the back of the meter (see page 12), unwrap the battery and install it. To prepare HI 8564 for use connect the RH probe to the DIN socket on the top of the meter. be removed. Whenever the probe is to be used in a dusty or smoky environment, the filter must be kept on at all times. TEMPERATURE MEASUREMENTS Simply press the °C or °F keys to take the temperature readings directly from the same probe. Note: Press °C key to display the temperature in °C. °C "°C" is displayed when measuring temperature in degrees Centigrade. ON OFF Turn the meter on by pressing the ON/OFF key. ON OFF EXAMPLE: A temperature reading taken in degrees Centigrade would read: °C °C Using the HI 8564 or HI 93640 thermo-hygrometer is simple. However, the recommendations below should always be followed. RELATIVE HUMIDITY MEASUREMENTS · The end of the humidity detector should be exposed to a current of air moving at 0.5 m (20") per second or more. · In the absence of air movement, the response can be accelerated by moving the probe. · The probe sensor must never come into contact with water or other liquids. If this should happen, or if condensation causes drops to form on the surface of the humidity sensor, turn off the instrument and wait until the liquid has evaporated completely. In order to accelerate the evaporation process, the humidity sensor could be exposed to a current of air. For HI 93640 only: in order to obtain a faster response, the sintered filter should 6 Press °F key to read the same value in degrees Fahrenheit: °F °F If you experience any problems in taking measurements, please contact your dealer or the nearest Hanna Instruments Customer Service Department. 7 CALIBRATION All Hanna hygrometers have been precalibrated at the factory. Hanna Instruments uses state-of-the-art thermal humidity chambers for this purpose. It is generally recommended to have all hygrometers recalibrated at least once a year. For an accurate annual recalibration, contact your nearest Hanna Service Center. You can also check the status of your HI 8564 and perform a quick recalibration (with an accuracy of ±5%) by using the Hanna mini-calibration chambers HI 7101. The kits are composed of two thermally isolated chambers, each one equipped with a threaded cap and three bottles containing the appropriate precalibrated saturated salts to produce a known RH value. Li Cl 11.1% Na Cl 75.4% · When the salt has dissolved completely, add all the content of the second bottle of HI 7111. · Allow the solution obtained to cool, and then pour it into the chamber marked "RH 11.1%", making sure that no residue remains on the walls of the glass container. Li Cl 11.1% Na Cl 75.4% CALIBRATION KIT · Seal the chamber well when not in use, as the LiCl solution is extremely hygroscopic and tends to capture the humidity present in the air causing the solution to expand in volume and to overflow from the container. H 2 CALIBRATION KIT Preparing the (HI 8564 only): Calibration Solutions O H2 · Pour approximately 12 cc of distilled water into the other chamber marked "RH 75.4%". Li Cl 11.1% Na Cl 75.4% CALIBRATION KIT · Pour approximately 26 cc of distilled water into a glass container. 26 cc · Immerse this container into a bath of ice and water and shake briefly. · Slowly add the contents of a HI 7111 bottle containing LiCl into the glass container while continuing to shake. 8 · Add all the content of the HI 7121 bottle containing NaCl while continuously shaking the container to avoid the formation of lumps. Seal this container well when not in use. The calibration kit needs 4 hours for stabilization. Li Cl 11.1% Na Cl 75.4% CALIBRATION KIT Li C l 12 9 3 6 9 l Li C O 12 cc Na Cl 4h RH Calibration Procedure (HI 8564 only): · Bring the calibration kit to a temperature of approximately 20°C. · Remove the cap from the "RH 11.1%" chamber containing the LiCl solution and insert the probe paying attention not to tip it into the liquid. · Remove the cap from the "RH 75.4%" chamber containing the NaCl solution and insert the probe. Li Cl 11.1% Na Cl 75.4% CALIBRATION KIT Li Cl 11.1% Na Cl 75.4% CALIBRATION KIT · Wait for the measurement to stabilize (approximately 4 hours) 12 9 3 6 4h · Remove the adhesive sticker which covers the calibration trimmer access holes. ON OFF · Turn the high humidity trimmer until the readout on the display is 64.3%. · Press the ON/OFF key to switch the instrument on. H 12 · Wait for the measurement to stabilize (this takes about 4 hours). 9 3 6 4h · Wait for 1 hour and readjust if necessary. · Leaving the probe in the "RH 75.4%" chamber, adjust the low humidity trimmer until the value of 75.4% is read. · Turn the low humidity trimmer (see Functional Description) until a value of 0.0% is seen on the readout (reading between 0.0% and 1.0% RH is also acceptable). H H · Now, the humidity calibration is complete. Spare saturation salts are also available: HI 7111/P (LiCl) for low range humidity, and HI 7121/P (NaCl) for high range humidity. · Remove the probe and tightly seal the chamber containing the LiCl solution. 10 11 BATTERY REPLACEMENT Battery replacement must only take place in a non hazardous area using the battery types specified in this instruction manual (see page 14). FOR HI 8564 ONLY: HI 8564 When the battery is run down "V" is displayed on the LCD to warn the user. In order to replace the battery, simply slide the cover off and replace it with a new 9V battery. SHOCKPROOF RUBBER BOOTS These rubber boots for HI 93640 are specially made to prolong the life of your meter and to prevent damages due to accidental dropping. This rubber boot measures 155 x 90 x 45 mm (6.1 x 3.5 x 1.8") and is available in two different colors: HI 710008 = orange HI 710007 = blue. Select the proper color according to your preference. BATTERY FOR HI 93640 ONLY: HI 93640 When the battery is rundown "V" is displayed on the LCD to warn the user. HI 93640 employs the advanced "BEPS" technology. BEPS will detect a low power condition and will shut the disSLIDE play off. If the ON/OFF butOFF ton is pressed again, the meter will shut off after a few seconds. When this occurs, replace the 9V battery with a new one. When the battery is exhausted or the instrument cannot be switched on, simply slide the battery cover off from the rear of the instrument and replace with the 9V battery with a new one. 9 VOL BA T TTERY °C THERMOHYGROMETER ON OFF RANGE: RH% 5 to 95 °C 0 to 60 °F 32 to 140 RH% °F °C HI93640 12 13 ACCESSORIES WARRANTY HI 70601/5 HI 710001 HI 710007 HI 710008 HI 710011 HI 710031 HI 7101 HI 7111/P HI 7121/P HI 721310 MANRHR2 Detachable interchangeable TFPC RH & temp. probe for HI 8564 with 5 m (16.5') cable Soft carrying case (for HI 8564 only) Blue rubber boot (for HI 93640 only) Orange rubber boot (for HI 93640 only) Spare sintered cap for protection (for HI 93640 only) Rugged carrying case Calibration chambers for HI 8564, complete with O-ring and pre-calibrated saturated salts Spare saturation salts 6 x 15g bottles of LiCl for low range humidity calibration Spare saturation salts 6 x 33g bottles of NaCl for high range humidity calibration 9V battery (10 pcs) Instruction manual All Hanna Instruments meters are warranted for two years against defects in workmanship and materials when used for their intended purpose and maintained according to the instructions. The probes are warranted for a period of six months. Damages due to accidents, misuse, tampering or lack of prescribed maintenance are not covered. This warranty is limited to repair or replacement free of charge. If service is required, contact the dealer from whom you purchased the instrumen ...

  Know our Partners   Frequently Asked Questions   Contact Diplodocs team   Last searches
Latest additions
  Sitemap
Brands starting with A B C D E F G H I J K L M N O P Q R S T U V W X Y Z #
Copyright © 2005 - 2008 - Diplodocs - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.