Detailed instructions for use are in the User's Guide.
Instruction Manual
HI 9063
Portable Waterproof Microprocessor K-Type Thermocouple Thermometer
Dear Customer, Thank you for choosing a Hanna product. This manual will provide you with the necessary information for correct operation. Please read it carefully before using the meter. If you need additional technical information, do not hesitate to email us at tech@hannainst.com. These instruments are in compliance with the directives.
FUNCTIONAL DESCRIPTION
Range (*) Resolution Accuracy (@20°C/68°F) Typical EMC Deviation Display Battery Type Life Probe Environment Dimensions Weight
SPECIFICATIONS
-50.0 to 199.9°C / 200 to 1350°C -58.0 to 399.9°F / 400 to 2462°F 0.1°C (up to 199.9°C) / 1°C (outside) 0.1°F (up to 399.9°F) / 1°F (outside) ±0.2% F.S. excluding probe error ±3°C (with HI 766 probes) ±6°F (with HI 766 probes) Dual-line LCD 4 x 1.5V AA (IEC LR6) approx. 2000 hours of continuous use K-type thermocouple (see "Accessories") -10 to 50ºC (14 to 122ºF); RH 100% 196 x 80 x 60 mm (7.7x3.1x2.4") 425 g (15 oz.) meter only
PRELIMINARY EXAMINATION
Remove the instrument from the packing material and examine it carefully to make sure that no damage has occurred during shipping. If there is any noticeable damage, notify your Dealer or the nearest Hanna Office. Note: Save all packing materials until you are sure that the instrument functions correctly. Any defective item must be returned in the original packaging together with the supplied accessories.
(*) Range may be limited by probe.
www.hannainst.com
This Instrument is in Compliance with CE Directives
WARRANTY
All Hanna Instruments meters are warranted for two years against defects in workmanship and materials when used for their intended purpose and maintained according to instructions. Sensors and probes are warranted for a period of six months. This warranty is limited to repair or replacement free of charge. Damages due to accidents, misuse, tampering or lack of prescribed maintenance are not covered. If service is required, contact the dealer from whom you purchased the instrument. If under warranty, report the model number, date of purchase, serial number and the nature of the failure. First obtain a Returned Goods Authorization number from the Customer Service department, then return the instrument with the Authorization # included along with shipment costs prepaid. If the repair is not covered by the warranty, you will be notified of the charges. When shipping any instrument, make sure it is properly packaged for complete protection. All rights are reserved. Reproduction in whole or in part is prohibited without the written consent of the copyright owner, Hanna Instruments Inc., Woonsocket, Rhode Island, 02895 , USA.
Hanna Instruments reserves the right to modify the design, construction and appearance of its products without advance notice.
GENERAL DESCRIPTION
HI 9063 is a waterproof, microprocessor-based, K-type thermocouple thermometer, which provides very accurate measurements in a wide range of temperatures. The meter is also provided with low battery detection and BEPS (Battery Error Preventing System), which turns the unit off when the batteries are discharged avoiding erroneous readings caused by low battery level. HI 9063 features include autoranging capability, dual-level LCD for simultaneously displaying of maximum and minimum measured temperatures, °C/°F selection button and hold function. Each meter is supplied complete with 4 x 1.5V AA batteries and instruction manual.
1. Temperature probe connector 2. Liquid Crystal Display 3. ON/OFF Key 4. Measuring unit selection key 5. HOLD measurement key 6. HI/LO values reset key
FACTORY RECALIBRATION
All Hanna Instruments thermometers have been accurately pre-calibrated at the factory. It is generally recommended to have all thermometers recalibrated at least once a year. For an accurate annual recalibration, contact your nearest Hanna Service Center.
1. Current temperature value 2. HOLD indicator 3. Low Battery indicator 4. Minimum temperature value 5. Maximum temperature value 6. K-type probe indicator 7. Measuring scale, °C or °F
OPERATIONAL GUIDE
INITIAL PREPARATION
Each meter is supplied complete with batteries. Remove the back cover, unwrap the batteries and install them while paying attention to their polarity. Connect a K-type thermocouple probe to the meter. To switch on, press the ON/OFF key on the front of the meter. If the meter does not come on, make sure that the batteries are correctly installed. The thermometer will carry out a self diagnostic test routine, the LCD will show all segments for a few seconds (or as long as ON/OFF is held), followed by the percentage indication of the remaining battery life. The thermometer then enters normal measurement mode. If a temperature probe is plugged in, the meter displays the measured temperature. If no probe is plugged in, or if reading is over-range, the display shows flashing dashes. If a measurement is slightly over the range of the meter specifications, the display flashes the closest full-scale value. To switch the thermometer OFF, press the ON/OFF key.
HIGH/LOW TEMPERATURES
The maximum and minimum temperatures are continuously monitored and displayed in the lower portion of the LCD. Note: When reading goes over-range, the Hi and Lo values display dashes until cleared.
ACCESSORIES
K-TYPE THERMOCOUPLE PROBES
with integral handle, 1 m (3.3') cable & mini-connector: HI 766A Roller surface probe, max 320°C/600°F HI 766B Surface probe, max 650°C/1200°F HI 766B1 90º Surface probe, max 450°C/840°F HI 766B2 Spring-loaded, surface probe, max 900°C/1650°F HI 766B3 Spring-loaded, small surface probe with insulated shaft, max 200°C/390°F HI 766C Penetration probe, max 900°C/1650°F HI 766C1 Ultra-fast Penetration probe, max 300°C/ 570°F HI 766D Air probe, max 300°C/570°F HI 766E1 General purpose probe, max 900°C/1650°F HI 766E2 General purpose probe, max 900°C/1650°F HI 766F High temperature, flexible wire probe without handle, max 1100°C/2000°F HI 766F1 Flexible wire probe without handle, max 480°C/ 900°F HI 766TR1 Penetration probe, max 250°C/482°F HI 766TR2 Penetration long probe, max 250°C/482°F HI 766TV1 Pipe clamp probe, max 200°C/390°F with detachable handle & mini-connector (to be used in conjunction with the HI 766HD probe handle): HI 766PA Roller surface probe, max 320°C/600°F HI 766PB Surface probe, max 650°C/1200°F HI 766PC Penetration probe, max 900°C/1650°F HI 766PD Air probe, max 300°C/570°F HI 766PE1 General purpose probe, max 900°C/1650°F HI 766PE2 General purpose probe, max 900°C/1650°F grill surface probe: HI 766B4 Grill surface probe with 70 cm (27.6'') cable (protected with stainless steel jacket), max 250°C/482°F HI 7664B4S Spare stainless steel sensor for HI766B4 probe
CE DECLARATION OF CONFORMITY
CLEAR FUNCTION
Upon pressing the CLEAR key, the current reading is assigned to the highest and lowest temperature values. The High/Low values may be cleared at any time during measurement.
BATTERY REPLACEMENT
The instrument is powered by four 1.5 V alkaline batteries and is provided with the Battery Error Prevention System (BEPS), which turns the unit off when a low battery signal is detected. When the remaining battery level is less than 10%, a warning symbol blinks on the display to indicate a low battery condition. It is recommended to replace the batteries as soon as the low battery condition is detected. Battery replacement must only take place in a nonhazardous area using four 1.5V alkaline batteries. In order to replace rundown batteries, simply remove the two screws on the rear cover of the instrument and replace the four batteries with new ones paying attention to the correct polarity. Reattach the cover and tighten the two screws.
MEASURING SCALE (°C/°F)
The instrument is factory set to the °C scale, but measurements can be performed in either the Celsius or Fahrenheit scale. Press the °C/°F button to select the desired scale.
Recommendations for Users
Before using these products, make sure that they are entirely suitable for the environment in which they are used. Operation of these instruments in residential areas could cause unacceptable interference to radio and TV equipment, requiring the operator to take all necessary steps to correct interference. Any variation introduced by the user to the supplied equipment may degrade the instruments' EMC performance. To avoid electrical shock, do not use these instruments when voltage at the measurement surface exceeds 24VAC or 60VDC. To avoid damage or burns, do not perform any measurement in microwave ovens.
HOLD MODE
The HOLD function is activated by pressing the HOLD key. The measured temperature is held on the display until HOLD is pressed again. The "H" tag blinks on the display to indicate the HOLD mode. Note: Although the display is frozen, internally the meter continues measuring and updating Hi and Lo values.
OTHER ACCESSORIES
HI 710002 HI 721317 HI 721308 HI 766EX HI 766HD Soft carrying case Hard carrying case (340x230x90 mm) 1.5V AA size, alkaline battery (10 pcs) Extension cable for K-type probes Rugged thermocouple probe handle with 1m (3.3') cable fitted with mini-connector
ISTR9063 01/03
...