9 562 brands
2 694 000 user's guides


Download your manual, it's FREE! Diplodocs allows you to download several types of document in order to best use your HANNA INSTRUMENTS HI 981411-0 : user manual, user guide, instruction manual.
Search a brand
Advanced Search

User manual HANNA INSTRUMENTS HI 981411-0

Diplodocs help download the user guide HANNA INSTRUMENTS HI 981411-0 .

Download the complete user guide (317 Ko)





Preview of the first 3 pages of manual

You either have JavaScript turned off or an old version of Adobe Flash Player
Get the latest Flash Player.
Manual abstract: user guide HANNA INSTRUMENTS HI 981411-0

Detailed instructions for use are in the User's Guide.

Instruction Manual HI 981411-0 HI 981411-1 Panel-Mounted pH Indicators & Controllers Dear Customer, Thank you for choosing a Hanna product. This manual will provide you with the necessary information for the correct operation of the meter. Please read it carefully before using the meter. If you need additional technical information, do not hesitate to e-mail us at tech@hannainst.com. These instruments are in compliance with the . SPECIFICATIONS HI 981411 Range Resolution Accuracy (@ 20°C/68°F) Offset Calibration 0.0 to 14.0 pH 0.1 pH ±0.2 pH Manual, through trimmer CE DECLARATION OF CONFORMITY PRELIMINARY EXAMINATION Remove the instrument from the packing material and examine it carefully. If any damage has occurred during shipment, immediately notify your Dealer or the nearest Hanna Customer Service Center. The meter is supplied with: - Mounting brackets; - Instruction manual. Note: Conserve all packing material until the instrument has been observed to function correctly. Any defective item must be returned in its original packing. Setpoint Adjustable, from 0.0 to 14.0 pH Dosing Selection Acid or Alkaline, selectable on the back panel Contact Open=Acid dosage=Relay ON if Measure > Setpoint Contact Close=Alkaline dosage=Relay ON if Measure < Setpoint Power supply: External HI 981411-0 12 VDC HI 981411-1 115/230 VAC; 50/60Hz Dimensions Weight: HI 981411-0 HI 981411-1 79 x 49 x 95 mm (3.1 x 1.9 x 3.7") 140 g (4.96 oz) 250 g (8.85 oz) HI981411-0 and HI981411-1 14-4-99 Manufactors since 1978 These Instruments are in Compliance with the CE Directives WARRANTY HI 981411-0 and HI 981411-1 are warranted for two years against defects in workmanship and materials when used for their intended purpose and maintained according to instructions. This warranty is limited to repair or replacement free of charge. Damages due to accident, misuse, tampering or lack of prescribed maintenance are not covered. If service is required, contact the dealer from whom you purchased the instrument. If under warranty, report the model number, date of purchase, serial number and the nature of the failure. If the repair is not covered by the warranty, you will be notified of the charges incurred. If the instrument is to be returned to Hanna Instruments, first obtain a Returned Goods Authorization Number from the Customer Service department and then send it with shipment costs prepaid. When shipping any instrument, make sure it is properly packaged for complete protection. To validate your warranty, fill out and return the enclosed warranty card within 14 days from the date of purchase. All rights are reserved. Reproduction in whole or in part is prohibited without the written consent of the copyright owner, Hanna Instruments Inc., Woonsocket, Rhode Island, 02895 , USA. Hanna Instruments reserves the right to modify the design, construction and appearance of its products without advance notice. GENERAL DESCRIPTION HI 981411-0 and HI 981411-1 are pH indicators and controllers with a relay output designed for simplicity of use in a wide range of applications. The models are panel-mounted with membrane keypads on the front panel and an easy-to-read LCD display. Power supply, wiring and selection are made via the plugin terminal blocks on the rear panel. The instruments are equipped with a BNC socket and accept input from conventional combination pH electrode. LED indicators on the front panel identify whether the controller is in set or reading mode, and if dosing device is activated. Recommendations for Users Before using this product, make sure that it is entirely suitable for the environment in which it is used. Operation of this instrument in residential areas could cause unacceptable interferences to radio and TV equipment. The glass bulb at the end of the electrode is sensitive to electrostatic discharges. Avoid touching this glass bulb at all times. During operation, ESD wrist straps should be worn to avoid possible damage to the electrode by electrostatic discharges. Any variation introduced by the user to the supplied equipment may degrade the instrument's EMC performance. To avoid electrical shock, do not use this instrument when voltages at the measurement surface exceed 24 VAC or 60 VDC. To avoid damages or burns, do not perform any measurement in microwave ovens. http://www.hannainst.com ISTR981411R5 06/2001 OPERATIONAL GUIDE POWER CONNECTION HI 981411-0 Connect a 2-wire power cable to the terminal strip while paying attention to the correct positive and negative contacts (12VDC). HI 981411-1 Connect a 3-wire power cable to the terminal strip while paying attention to the correct earth, neutral and line contacts (115/230 VAC). Notes: · All external cables connected to the rear panel should end with wire lugs. · It is recommended to cover the unused terminals with insulating tape. · At start up the meter needs a few seconds to stabilize. Wait until a stable reading is displayed. DOSING CONTACT This contact (maximum 5A, 240VAC, 30VDC) is used for connection to an alarm or dosing system. The relay contact acts as a power switch for the controlling device. OPERATING THE METER All settings of the parameters can be controlled via front panel keys and trimmers. "SET" and "MEAS" LEDs light up to indicate which is the operating function. Make sure that the meter is calibrated and that the Setpoint is properly adjusted before proceeding. Attach the pH-electrode to the meter with a BNC connector. Install the electrode in the fittings or immerse it in the solution to be monitored. Press the "MEAS" key. The LCD will show the pH value. Any initial variation on readings may be due to temperature compensation. The "DOSING" LED will light up when the dosing contact is closed. CALIBRATION Make sure the meter is in the measurement mode (the "MEAS" LED lights on). Immerse the electrode in HI 7007 (pH7.01) buffer solution (or any buffer solution close to the operating pH value). Shake briefly and wait for reading to stabilize. Adjust the calibration trimmer until "7.0" is displayed on the LCD. SETPOINT Press the "SET" key. The display will show the default or previously adjusted value. Using a small screwdriver adjust FUNCTIONAL DESCRIPTION FRONT PANEL Keypad SET MEAS To display setpoint To display measurement HI 981411 pH CONTROLLER pH 0.0 ...14.0 pH HI981411 LAYOUT pH ELECTRODES Heavy-duty BNC-type double junction, plasticbody with external thread and 5m (16.5') cable HI1090T Screw type, double junction, glass-body with external thread HI1110S Screw type, single junction, glass-body HI1210T Screw type, double junction, plastic-body with external thread HI2114P/2 BNC-type, double junction plastic-body with 2m (6.6') cable HI1210B/5 BNC-type cable, double junction, plastic-body, with 5 m (16.5') cable HI2910B/5 BNC-type, double junction, plastic-body, builtin amplifier, with 5 m (16.5') cable EXTENSION CABLES FOR SCREW-TYPE ELECTRODES TO BNC CONNECTOR HI7855/5 HI7855/10 Extension cable 5m (16.5') long Extension cable 10m (33') long HI1002/5 Front view of the panel-mounted unit 73mm 2.87" 79mm 3.11" Trimmers CAL For pH Offset Calibration SET To adjust the Setpoint SET DOSING CAL MEAS SET LEDs SET MEAS DOSING ON when LCD displays the set value ON when the LCD displays the measurement value ON when dosing contact is activated Side view of the panel-mounted unit Supplied adjustable location brackets allow the controller to slide into the cutout and will hold the unit securely in place. 95mm (3.74") is the minimum amount of space required to install the controller. 42mm 1.65" 49mm 1.93" 0.25/4mm 0.01/0.160" ADJUSTABLE LOCATION BRACKET 79mm 3.11" 76mm 3" 95mm MIN 3.74" REAR PANEL 1. Power Supply: HI 981411-0 HI 981411-1 12VDC 115/230 VAC L1: Positive 230 VAC L2: Negative 115 VAC L3: -----Neutral L4: -----Protection Earth Note: the power input is internally protected by a 400 mA fuse. Panel-mounted unit assembling view OTHER ACCESSORIES BL PUMPS Dosing Pumps with flow rate from 1.5 to 20 LPH HI 740146 HI 6050 HI 6051 HI 6054B HI 6054T HI 710005 HI 710006 HI 710012 HI 710013 HI 710014 HI 731326 HI 7871 HI 7873 Submersible electrode holder, 60cm (24") Submersible electrode holder, 110cm (43") Electrode Holders for in-line applications Electrode Holders for in-line applications 12 VDC power adapter, US plug 12 VDC power adapter, European plug 12 VDC power adapter, Australian plug 12 VDC power adapter,Southern Africa plug 12 VDC power adapter, UK plug Calibration Screwdriver (20 pcs) Level Controller (min and max) Level Controller (min, max and overflow) ACCESSORIES pH CALIBRATION SOLUTIONS HI 7007M pH 7.01 Buffer Solution, 230mL bottle HI 7007L pH 7.01 Buffer Solution, 460mL bottle ELECTRODE STORAGE SOLUTION HI 70300M Storage Solution, 230mL bottle ELECTRODE CLEANING SOLUTIONS HI 7061M General Cleaning Solution, 230mL bottle HI 7061L Oil & Fat Cleaning Solution, 230mL bottle 2. Dosing Selection Contacts: Leave S1 and S2 open to select ACID dosage; Short S1 and S2 to select ALKALINE dosage. 3. The dosing (alarm) contact acts as a switch. The contact has to be protected outside by the user. ...

  Know our Partners   Frequently Asked Questions   Contact Diplodocs team   Last searches
Latest additions
  Sitemap
Brands starting with A B C D E F G H I J K L M N O P Q R S T U V W X Y Z #
Copyright © 2005 - 2008 - Diplodocs - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.