9 562 brands
2 694 000 user's guides


Download your manual, it's FREE! Diplodocs allows you to download several types of document in order to best use your HANNA INSTRUMENTS HI 98301 : user manual, user guide, instruction manual.
Search a brand
Advanced Search

User manual HANNA INSTRUMENTS HI 98301

Diplodocs help download the user guide HANNA INSTRUMENTS HI 98301 .

Download the complete user guide (182 Ko)





Preview of the first 3 pages of manual

You either have JavaScript turned off or an old version of Adobe Flash Player
Get the latest Flash Player.
Manual abstract: user guide HANNA INSTRUMENTS HI 98301

Detailed instructions for use are in the User's Guide.

DiST HI98300/1/2/3/4 Conductivity/TDS Meters with Automatic Temperature Compensation OPERATION: · Remove the protective cap. · Turn the DiST on. · Immerse it in the solution to be tested without exceeding the maximum immersion level. BEPS AND BATTERY REPLACEMENT: DiST is supplied with BEPS (Battery Error Preventing System) which avoids any erroneous reading due to low batteries level, by switching the meter off. To replace the batteries, slide off the battery compartment cover and replace all four 1.5V batteries while paying attention to their polarity. · Stir gently and wait for the reading to stabilize. DiST automatically compensates for temperature variations. Batteries should only be replaced in a nonhazardous area using the battery type specified in this instruction sheet. · The reading on display is directly expressed in: ppm (mg/L) unit for DiST1 (HI98300 & HI98301 HI98300 HI98301), ppt (g/L) unit for DiST2 (HI98302 HI98302), HI98302 µS/cm for DiST3 (HI98303 and HI98303) HI98303 mS/cm for DiST4 (HI98304 HI98304). HI98304 CALIBRATION: · Immerse the DiST in the indicated calibration solution (see Specifications), without exceeding the maximum immersion level. · Allow the reading to stabilize and with a small screwdriver turn the calibration trimmer until the display shows the required solution value. E.g. for calibrating HI98301 the correct calibration solution is HI70032 and the trimmer should HI70032, be turned until the display shows "1382". ACCESSORIES: HI 70030P 12880 µS/cm calibration kit (25 x 20 mL sachets) HI 70031P 1413 µS/cm calibration kit (25 x 20 mL sachets) HI 70032P 1382 ppm (mg/L) calibration kit (25 x 20 mL sachets) HI 70038P 6.44 ppt (g/L) calibration kit (25 x 20 mL sachets) HI 70039P 5000 µS/cm calibration kit (25 x 20 mL sachets) HI 70442P 1500 ppm calibration kit (25 x 20 mL sachets) HI 73301 Spare electrode for DiST1 HI 73302 Spare electrode for DiST2 HI 73303 Spare electrode for DiST3 HI 73304 Spare electrode for DiST4 HI 731326 Calibration screwdriver (20 pcs) Manufacturers since 1978 Visit our Internet Home Page: http://www.hannainst.com SPECIFICATIONS: RANGE / RESOLUTION DiST1 (HI98300 & HI98301) 0 to 1999 ppm/1ppm DiST2 (HI98302) 0.00 to 10.00 ppt / 0.01ppt 0 to 1999 µS/cm / 1µS/cm DiST3 (HI98303) DiST4 (HI98304) 0.00 to 19.99 mS/cm / 0.01mS/cm ACCURACY (@20°C/68°F) ±2% f.s. TYPICAL EMC DEVIATION ± 1% f.s. TDS FACTOR HI98300 0.65 HI98301 & HI98302 0.5 CALIBRATION SOLUTIONS HI98300 HI70442 (1500 ppm) HI98301 HI70032 (1382 ppm) HI98302 HI70038 (6.44 ppt) HI98303 HI70031 (1413 µS/cm) HI98304 HI70039 (5.00 mS/cm)-HI70030 (12.88 mS/cm) TEMP.COMPENSATION 0 to 50 C (32 to 122ºF) ENVIRONMENT 0 to 50 C (32 to 122 F); 95% RH not condensing BATTERY TYPE 4 x 1.5V alkaline (included) BATTERY LIFE approx. 200 hours of continuous use DIMENSIONS 175 x 41 x 23 mm (7.9 x 1.8 x 1") WEIGHT 78 g (2.7 oz.) ELECTRODE REPLACEMENT: The electrode is built-in inside the plastic casing and can be easily replaced in the following way: · Slide off the battery cover. · Remove the screw on the back of the DiST located below the battery compartment and slide off the whole internal part of the tester. Internal circuit: · Fasten the screw on the back, below the battery compartment. ONE YEAR WARRANTY AND SERVICEABLE: Covered by one year warranty against defects in workmanship and materials, these testers are now completely serviceable. Contact your dealer for further information. The DiST is in compliance with the CE directives. · Replace the built-in electrode with a new: HI73301 for DiST1 HI73302 for DiST2 HI73303 for DiST3 HI73304 for DiST4 · Before reinserting the internal circuit into the new plastic casing, make sure the O-rings (2) of the temperature sensor (3) are properly seated (see drawing). To avoid bending the connections to the conductivity sensors (1), do not apply excessive force while inserting the circuit. In case of any problem, reslide and reinsert it. · Reinsert the battery compartment cover. · Recalibrate the DiST before performing new measurements. DISTNEW-R3 07/01 ...

  Know our Partners   Frequently Asked Questions   Contact Diplodocs team   Last searches
Latest additions
  Sitemap
Brands starting with A B C D E F G H I J K L M N O P Q R S T U V W X Y Z #
Copyright © 2005 - 2008 - Diplodocs - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.