Need help using a product?
|
|
|
|
User manual HITACHI CM1711MET
Diplodocs help download the user guide HITACHI CM1711MET .
This product, although classified under the brand HITACHI, may have been manufactured by HITACHI POWER TOOLS, MAXELL after mergers, acquisitions, or a change in name.
Preview of the first 3 pages of manual
You either have JavaScript turned off or an old version of Adobe Flash Player Get the latest Flash Player.
Manual abstract: user guide HITACHI CM1711MET
Detailed instructions for use are in the User's Guide. COLOUR MONITOR
BEDIENUNGSANLEITljNG . ..17 MANUAL DE USUARIO . ..31 CM1 711 MET-PCMP GEBRUIKSAANWIJZING . ..35 MANUEL UTILISATEUR . . .s
with EasyMenu !
EasyMenu is HITACHI's On Screen Display function for easy operation.
HITACHI - -- -- --- --
USER MANUAL . . ..I
READ THE INSTRUCTIONS INSIDE CAREFULLY. KEEP THIS USER MANUAL FOR FUTURE REFERENCE.
For future reference, record the serial number of your colour monitor. EPA POLLUTION PREVENTER This monitor is Energy Star compliant when used with a computer equipped with VESA DPMS. The Energy Star emblem does not represent E P A endorsement of any product or service.
.-. The serial number is located on the rear of the monitor.
SERIAL No.
COLOUR MONITOR
ENGE
CM171 1 MET-
PCMP
USER MANUAL
USH =
I
NOTICE : The information in this document is subject to change without notice. The manufacturer assumes no responsibility for any errors that may appear in this manual. I
FEATURES . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . CAUTIONS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . INSTALLATION . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . STANDARD SETTINGS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . OPERATION . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . POWER SAVING SYSTEM . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . PLUG&PLAY . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . SPECIFICATIONS ...........................................
2 3 4 8 9 14 14 15
TRADEMARK ACKNOWLEDGMENT VGA is a registered trademark of International Business Machines Corporation. Apple and Macintosh are registered trademarks of Apple Computer, Inc. VESA is a trademark of a nonprofit organization, Video Electronics Standard Association. Energy Star is a trademark of Environmental Protection Agency.
-ENG
The provided
USH
by flat screen CRT with anti-glare, dynamic focus circuit, dark glass, and an INVAR shadow mask gives the sharpest focus and highest contrast to minimize eye fatigue.
Sharpest Focus and Highest Contrast
Wide-range Multi-Scanning
Automatic scanning and automatic adjustment to conform with a wide range of scanning frequencies and user requirements.
Digital Picture Control Function
Position, size, pincushion, trapezoid and rotation are adjustable by digital controls. Geometry setting can be stored for different H/V frequencies. Microprocessor-based functions can store 20 sets of geometry settings including the standard factory settings. preset
Digital Colour Control Function
Red, green, and blue colour balance is adjustable by digital control. Adjusted colour setting can be stored and recalled by the `Colour Select li function.
Power Saving System
The Environmental Protection Agency has established a voluntary program by which manufacturers enable computer products to go into low power states while not being used. This monitor has a low power `sleep" mode, which is compliant with the EPA requirements for the `Energy Star' program, and will assist you in conserving energy. Please refer to the section of "POWER SAVING SYSTEM" for details.
EasyMenu
On Screen Display function that allows direct access to adjust all operations from front panel.
PLUG & PLAY
This monitor is VESA DDClPB compliant when used with a computer compliant with VESA DDC (Display Data Channel).
2
! NEVER REMOVE THE REAR COVER I
The rear cover MUST be removed only by authorized service personnel. This colour monitor contains high voltage components.
ENGZ USH =
! BE CAREFUL OF STATIC ELECTRICITY ON CRT SURFACE ! BE CAREFUL OF GENERATED MAGNETISM !
!
To prevent electrical shock by the static electricity on the CRT surface, disconnect the power cord at least 30 SECONDS AFTER turning off the power. After the power has been turned on or `DEGAUSS" button has been pressed, the CRT is demagnetized for approximately 10 seconds. This generates a strong magnetic field around the front cover which may affect the data stored on magnetic tape or disks near the front cover. Place such magnetic recording equipment and tapes/disks apart from this unit.
! AVOID FREQUENT POWER ON-OFF SWITCHING !
DO NOT repeat OFF and ON in a short period. It may cause blurred colours or distortion of the displayed pattern.
! REMOVE THE POWER CORD FOR COMPLETE SEPARATION ! !
AMBIENT ILLUMINATION ABOUT CLEANING
!
For complete separation from the power source, remove the power cord from the monitor or from the wall outlet. Avoid direct rays of the sun or room lighting onto the CRT screen in order to prevent eye fatigue. This monitor has a non-glare and anti-electrostatic treatment on the surface of the screen. Use water or alcoholic solvent with soft cloth like gauze to clean the surface of the screen. NEVER use abrasive, glass cleaner containing highly concentrated ammonia and strong base chemicals since they damage the surface treatment. Clean the cabinet and controls with a lightly moistened soft cloth. DO NOT use aerosol sprays, solvents or abrasive cleaners.
!
CAUTION for 200V operation only
This equipment relies on the protective devices in the building installation for short - circuit and over - current protection. Refer to the following table for the suitable number and location of the protective devices which should be provided in the building installation. Protective devices in single - phase equipment or sub - assemblies Protection against Equipment to be connected to POWER SYSTEMS with earthed neutral reliably identified Equipment to be connected to any supply, including IT POWER SYSTEMS and supplies with reversible plugs Earth faults Overcurrent Earthfaults Overcurrent Minimum number of fuses or circuit breaker poles 1 1 2 1 Location Both conductors Either of the two conductors Both conductors Either of the two conductors 4
Verify that the protective devices in the building installation meets the conditions in the table prior to installing the equipment
3
EF;z
Install the monitor in the following way, taking care to maintain safety.
1. Installation
Install the monitor on a horizontal base.
Front Cover CRT Surface
Tilt & Swivel Base I
FRONT VIEW
Rear Cover
AC Inlet -I Signal Input CoYector I
REAR VIEW
A NOTICE INSTALL THE UNIT IN ADEQUATE ENVIRONMENT !
DO NOT expose this monitor to rain or moisture to prevent electric shock or fire hazard. This unit is designed to be used in an office or business environment. DO NOT subject the unit to vibrations, dust, or corrosive gases.
4
KEEP IN A WELL VENTILATED PLACE !
DO NOT cover this monitor or place anything against any sides (not only top, right and left side but also rear and bottom side) of unit. Ventilation holes are provided at all sides of the rear cover to prevent the temperature from rising.
KEEP AWAY FROM HEATING RADIATION OR SOURCE !
AVOID placing the unit in direct sunshine or near a heating appliance.
BE CAREFUL OF MAGNETIC FIELDS !
DO NOT place a magnet, loudspeaker system, floppy disk drive, printer, or anything which will generate magnetism near the unit. A magnetic field may cause blurred colours or distortion of the displayed pattern.
2. Power Cord Connection
0 Make sure of using the power cord meeting the safety standard of the country, you are using the monitor. @ Insert the connector of a power cord to the AC Inlet of the monitor. @I Insert the plug of the power cord to a receptacle of the correct voltage.
/ AC Inlet -yt 1'
to a receptacle of the correct voltage a+= a POW@' Cord / 11 \ ' REARVIEW
% 1
, AQ
\'
B NOTICE
q In USA/Canada, use a UL LlSTED/CSA LABELLED or CERTIFIED power cord set meeting the following specifications. Length: max. 3.1 m Type: SVT or SJT Rating: min. 125V, 7A Plug type: NEMA 5-15P, Parallel blade, Grounding type, 125V, 15A In Europe, a proper European standard approved power cord is to be used with this monitor. For a rated current up to 6 A, a type not lighter than H05W-F 3G 0.75 mm2 or H05WH2-F 3G 0.75 mm2 shall be used. Failure to do so may cause fire or electric shock hazard. w The enclosed power cord shall be used if provided. n Use only the correct voltage power outlet with safety ground connection. 100 - 120 V for USA, Canada, etc. 200 - 240 V for Europe, etc. (This monitor automatically adjust to the input voltage 100 - 120 / 200 - 240V.) n The receptacle should be close to the monitor and easily accessible.
5
A FOR THE CUSTOMERS IN U.K.
=ENG - USH THIS PRODUCT IS SUPPLIED WITH A TWO PIN MAINS PLUG FOR USE IN MAINLAND EUROPE. FOR THE U.K. PLEASE REFER TO THE NOTES ON THIS PAGE.
IMPORTANT FOR UNITED KINGDOM
WORDING FOR CLASS I EQUIPMENT INSTRUCTION BOOKS AND LABELS The mains lead on this equipment is supplied with a moulded plug incorporating a fuse, the value of which is indicated on the pin face of the plug. Should the fuse need to be replaced, an ASTA or BSI approved BS 1362 fuse must be used of the same rating. If the fuse cover is detachable never use the plug with the cover omitted. If a replacement fuse cover is ,xtuired, ensure it is of the same oolour as that visible on the pin face of the plug. Fuse oovers are available from your dealer. DO NOT cut off the mains plug from this equipment. If the plug fitted is not suitable for the power points in your home or the cable is too shot-l to reach a power point, then obtain an appropriate safety approved extension lead or consult your dealer. Should it be necessary to change the mains plugs, this must be carried out by a competent person, preferably a qualified electrician. If there is no alternative to cutting off the mains plug, ensure that you dispose of it immediately, having first removed the fuse, to avoid a possible shook hazard by inadvertent connection to the mains supply.
WARNING: THIS EQUIPMENT MUST BE EARTHED
IMPORTANT The wires in the mains lead are coloured in accordance with the following code: Green and Yellow = Earth, Blue = Neutral, Brown = Live.
Green &Yellow to Earth
Brown to Live
Fuse Blue to Neutral Cord Clamp As these colours may not correspond with the coloured markings identifying the terminals in your plug, proceed as follows: The wire which is coloured GREEN and YELLOW must be connected to the terminal in the plug which is marked with the letter E or by the earth symbol @ or coloured GREEN or GREEN and YELLOW. The wire coloured BLUE must be connected to the terminal marked with the letter N or coloured BLUE or BLACK. The wire coloured BROWN must be connected to the terminal marked with the letter L or coloured BROWN or RED.
6
3. Signal Input Connection
Connect the Signal Input Connector to the D-Sub Mini IBpin signal output terminal of the host computer.
to the host computer b' QIg , REAR VIEW ENGe LISH -
+@-
Signal Input Connector
l
If the graphics board supplies more than one type of sync. signal, the sync. signal type will be automatically selected by the monitor, with the priority shown in the following table.
4. Power On
Turn on the Power Switch of the monitor first, then the computer. Refer to Page 9 `POWER ON/OFF".
NOTICE
w After turning OFF the switch, wait at least 5 seconds to restart the monitor. Otherwise the monitor may operate unusually. n If the picture doesn't appear, turn OFF the power switch, make sure of'the following and wait at least 30 seconds to restart the monitor. Make sure the power switch of the computer, power cord connection, signal cable connection and the input sync. signal are right. 1 If the colour is impure on the screen after turning ON the monitor, wait for about 10 minutes and press the Degauss button.
7
l
Microprocessor-based preset functions can store 20 sets of geometry settings including the standard settings. Below listed preset modes. The following industrial standard settings have been preprogrammed by the factory.
NOTE
w Input signals with approximately the same frequencies may be regarded as the same signal. n The following horizontal timing conditions are recommended. Horizontal front porch should be more than 0.1 us. Horizontal sync. width should be more than 1 .O us. Horizontal back porch should be more than 1.2 us. Horizontal blanking width should be more than 3.0 ps for 31 kHz - 55 kHz or 2.7 ps for 55 kHz - 82 kHz w The following vertical timing conditions are recommended. Vertical front porch should be more than 10.9 us. Vertical sync. width should be less than 0.3 ms. Vertical back porch should be more than 400 us. Vertical blanking width should be more than 450 us. q In case the front or back porch is extremely long, or the data display time is extremely short, it may not be able to set the expected size and position. n Standard settings are subject to change without notice.
8
- Control Panel p
-Function LED `p--l~Jj [-=-g-J F&T-J ffy Power LED -O @
F"t;;;N
I page 12
+fOR~ ...
|