9 562 brands
2 694 000 user's guides


Download your manual, it's FREE! Diplodocs allows you to download several types of document in order to best use your HITACHI CMPAK06 : user manual, user guide, instruction manual.
Search a brand
Advanced Search

Need help using a product?
Look at the reviews on HITACHI CMPAK06

User manual HITACHI CMPAK06

Diplodocs help download the user guide HITACHI CMPAK06 .

Download the complete user guide (324 Ko)



This product, although classified under the brand HITACHI, may have been manufactured by HITACHI POWER TOOLS, MAXELL after mergers, acquisitions, or a change in name.



Preview of the first 3 pages of manual

You either have JavaScript turned off or an old version of Adobe Flash Player
Get the latest Flash Player.
Manual abstract: user guide HITACHI CMPAK06

Detailed instructions for use are in the User's Guide.

Hitachi Plasma Display Tilting Wall-mount Unit Model CMPAK06 Installation Instructions Thank you for purchasing the Hitachi Plasma Display Wall-mount Unit. To ensure correct usage, please read this instruction manual thoroughly. After reading, please store this manual in a safe place for future reference. This plasma display wall-mount unit is for use only with the following model: CMP5000WX Special techniques are necessary for installation of the plasma display. Do not attempt to perform this work by yourself. Request an installation specialist to install this unit. This company assumes absolutely no responsibility for injuries and damages that may occur due to improper installation and handling. Please remember that if you remove the plasma display set from the wall later, you will find the screw holes and anchor bolts for the mounting unit left on the wall. Also note that a long use of the plasma display set may discolor the wall around it due to its heat and air flow. To dealers and shops To ensure customer safety, be sure to design the installation location so that the strength is sufficient to withstand the weight of both the plasma display and the wall-mount unit. Always use at least two persons for all installations. Fully tighten all of the mounting screws as specified in the installation instructions. Parts Configuration Chart IConfirming the parts provided Before assembly, check to make sure that none of the parts provided are missing. * Screws to be used for wall installation are not included. Obtain them separately. Bolts M8 (6) Hexagon wrench (1) Hung on wall unit (1) Usage cautions to ensure correct usage Symbols The following symbols are used to ensure safe usage of the product, to prevent danger to yourself and other parties and to prevent damage to property. WARNING CAUTION This symbol indicates that incorrect handling due to ignoring this symbol can result in the possibility of personal injury or even death. This symbol indicates that incorrect handling due to ignoring this symbol can result in the possibility of personal injury and physical damage. This symbol indicates additional cautions (including warnings). Caution (general) This symbol indicates forbidden actions. Forbidden (general) This symbol indicates required actions. Required (general) Indicates that the power plug is to be disconnected from the power outlet. Disassembly prohibited Safety Cautions WARNING When a malfunction occurs, disconnect the power plug from the power outlet and take measures to prevent other people coming near the plasma display. In the cases such as The plasma display is loose and vibrates to an extreme degree, Mounting screws or parts are loose or missing, failure to take appropriate actions can result in injury. Perform the following actions immediately whenever a malfunction occurs. Turn off the plasma display power switch. Disconnect the power plug from the power outlet. Surround the area with rope, etc., to prevent other people coming near. Contact your local dealer. Disconnect the power plug from the power outlet. Contact your local dealer. Handling by other than professional contractors is prohibited. Ask your dealer to install, move or adjust the wallmount unit. Incorrect installation or adjustment can cause the plasma display to fall. Installation Location WARNING Plaster board or thin ply wood, etc. The wall where the wall-mount unit is to be installed must be capable of long-term support of the total load of the plasma display and wall-mount unit. Measures should also be taken to ensure sufficient strength to withstand the force of earthquakes, vibration and other external forces. Incorrect installation can cause the plasma display to fall and cause injury. Pillar or thick ply wood. Model 50 Total load of the (plasma display + wall-mount unit) = 52.7kg Installation on a wooden wall Always install so that the load is supported by a piller. If the strength of the piller is insufficient, add reinforcement. Do not install on plasters or decorative posts. Installation on a concrete wall Use commercially available anchors that are capable of fully supporting the load of the plasma display. CAUTION Avoid installing in locations where the temperature and humidity are excessively high, and where contact with water is possible. These can result in fire or electrical shock. 10cm or more 10cm or more 10cm or more Do not block the ventilation holes. Also provide sufficient clearance in regard to the surroundings to avoid blocking the ventilation. The internal temperature could elevate and possibly result in fire. Do not install close to an airconditioner intake or outlet. Do not install in locations where there is excessive amounts of dust, oily smoke or tobacco smoke. Fire could result. Mount only on a vertical, rigid wall surface. The internal temperature could elevate and possibly result in fire. Injury or damage could also result from falling. CAUTION Do not install in locations where there is excessive vibration or impact. Injury and damage could result from falling. Do not install where there is direct sunlight and other strong light. Strong light could result in eye fatigue during usage. Installing WARNING Use the specified bolts and screws in the specified places and tighten firmly. Failure to do this could cause injury if the plasma display falls. Make sure the display fittings and wall-mount fittings are firmly engaged. Failure to do so could cause the plasma display to fall. Do not alter any of the parts. And do not use broken parts. This could result in injury due to the plasma display falling. Always use at least two people to perform the installation work. Injury could result from dropping heavy objects. Use care to prevent the fingers being caught. Installation Method Installation procedure 1 Remove the special screws (2 locations) from the bottom of the hung on wall unit. Be sure to install the speaker at this stage. For the installation method, refer to the speaker installation procedure in the speaker user manual. 5 Attach the wall side hardware to the wall. Install the wall side hardware (4 locations) symmetrically on the left and right side (one at each location from the center of the ). Because the screws and bolts used to do this are different according to the wall strength and wall material, purchase suitable screws and bolts separately. Check the strength of the wall and beams before installing the display. Special screws (M6) 2 Remove the hardware on the wall side and the hardware on the PDP side. Wall side hardware PDP side hardware 3 Attach the PDP side hardware to the plasma 6 Attach the hook on the PDP side hardware to the wall side hardware. display. Do not hold the speakers during the installation work. · Cover the display with a sheet or similar protective material to protect it from scratches or other damage. · Be sure to attach it on top of a flat table or similar surface. Plasma display PDP side hardware Top side of plasma display 7 Fix the bottom of the hardware with the special screws removed at step 1 (one on the left and one on the right). 4 Fix the plasma display to the PDP side hardware with bolt M8 (6 locations). Usually, use the holes marked with the red triangle "". Special screw (M6) Top side of plasma display Installation Method Angle setup This installation hardware allows the display to be directed downwards freely at any angle from the vertical to 25. This adjustment must always be done by 2 people. Adjust the angle by rotating the screws at the center top and center bottom of the wall side hardware to the left or right. If the angle is increased while you are adjusting the angle using the screw at the center of the bottom, it is difficult to turn the screw. When this happens, adjust it at the center of the upper. Turn the screws very carefully to avoid damaging the wall. When a screw becomes tight at either end of the adjustment range, do not turn the adjustment screw any further, because if you do, you will apply excessive force, deforming the screw. (A) Criterion for the vertical location Gap disappears Back of the plasma display (B) Criterion when its angle is 25 End face of the plate Resin plate Wall side hardware Notch Matched in both directions When it is in this state, do not turn the adjustment screw any further in the closing direction. When it is in this state, do not turn the adjustment screw any further in the opening direction. Opening Closing Hexagon wrench Measuring the opening distance X enables approximate angle values to be determined. X A B Tilt Angle Criteria Angle X 133mm 188mm 241mm 291mm Resin plate 5 10 15 20 Product Specifications External Dimensions 98 (314) (239) (125) 655 555 455 33 (314) 239 (258) 25° (143) 45 35 150 714 35 410 59 212 232 465 545 150 (44) 35 6-23x10.5 (43) 6-10.5 54 496 740 1218 (Without side speaker) 1368 (With side speaker) Mass Main material 13.8kg Steel sheet Surface treatment Black baked paint Products mounted CMP5000WX 44 573 Hitachi, Ltd. Tokyo Japan Digital Media Division 292 Yohida-cho, Totsuka-ku, Yokohama, 244-0817 Japan (045) 866-6302 ...

  Know our Partners   Frequently Asked Questions   Contact Diplodocs team   Last searches
Latest additions
  Sitemap
Brands starting with A B C D E F G H I J K L M N O P Q R S T U V W X Y Z #
Copyright © 2005 - 2008 - Diplodocs - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.