9 562 brands
2 694 000 user's guides


Download your manual, it's FREE! Diplodocs allows you to download several types of document in order to best use your HITACHI CMPAT04 : user manual, user guide, instruction manual.
Search a brand
Advanced Search

Need help using a product?
Look at the reviews on HITACHI CMPAT04

User manual HITACHI CMPAT04

Diplodocs help download the user guide HITACHI CMPAT04 .

Download the complete user guide (230 Ko)



This product, although classified under the brand HITACHI, may have been manufactured by HITACHI POWER TOOLS, MAXELL after mergers, acquisitions, or a change in name.



Preview of the first 3 pages of manual

You either have JavaScript turned off or an old version of Adobe Flash Player
Get the latest Flash Player.
Manual abstract: user guide HITACHI CMPAT04

Detailed instructions for use are in the User's Guide.

Hitachi Plasma Display Ceiling Mount Unit Model CMPAT04 Special techniques are necessary for installation of the plasma display. Do not attempt to perform this work by yourself. Request an installation specialist to install this unit. This company assumes absolutely no responsibility for injuries and damages that may occur due to improper installation and handling. Installation Instructions Thank you for purchasing the Hitachi Plasma Display Ceiling Mount Unit. To ensure correct usage, please read this instruction manual thoroughly. After reading, please store this manual in a safe place for future reference. This plasma display ceiling mount unit is for use only with the following models : CMP401X, CMP402HD, CMP307X · To dealers and shops · To ensure customer safety, be sure to design the installation location so that the strength is sufficient to withstand the weight of both the plasma display and the Ceiling mount unit. · Always use at least two persons for all installations. · Firmly install coupling pins, snap pins and screws as specified in the installation instructions. Parts Configuration Chart Packed in a temporarily assembled condition Ceiling mount unit X1 Coupling pin X2 Snap pin X2 In the parts packing M6 X 18 screw X8 Parts for CMP401X only Angle adjustment unit X1 (left) (right) Support X2 M4 x 12 screw X4 Display mount fitting 1 each left/right Usage cautions to ensure correct usage Symbols · The following symbols are used to ensure safe usage of the product, to prevent danger to yourself and other parties and to prevent damage to property. This symbol indicates that incorrect handling due to ignoring this symbol can result in the possibility of personal injury or even death. This symbol indicates that incorrect handling due to ignoring this symbol can result in the possibility of personal injury and physical damage. This symbol indicates forbidden actions. This symbol indicates required actions. WARNING CAUTION This symbol indicates additional cautions (including warnings). Caution (general) Forbidden (general) Disassembly prohibited Required (general) Indicates that the power plug is to be disconnected from the power outlet. Safety Cautions WARNING When a malfunction occurs, disconnect the power plug from the power outlet and take measures to prevent other people coming near the plasma display. Disconnect the power plug from the power outlet. Contact your local dealer. In the cases such as · The plasma display is loose and vibrates to an extreme degree, · Mounting screws or parts are loose or missing, failure to take appropriate actions can result in injury. Perform the following actions immediately whenever a malfunction occurs. 1.Turn off the plasma display power switch. 2.Disconnect the power plug from the power outlet. 3.Surround the area with rope, etc., to prevent other people coming near. 4.Contact your local dealer. Ask your dealer to install, move or adjust the angle of the ceiling mount unit. Handling by other than professional contractors is prohibited. Incorrect installation or adjustment can cause the plasma display to fall. Installation Location WARNING The ceiling where the ceiling mount unit is to be installed must fully support the weight of the plasma display and the ceiling mount unit for an extended period of time. Take measures to fully withstand earthquake, other vibration and external forces. Incorrect installation can cause the plasma display to fall and cause injury. Total load of the (plasma display + ceiling mount unit) = 51kg · Always use bolts, washers and nuts to firmly install on a rigid construction member such as ceiling beam, etc. · Do not mount directly on a ceiling of insufficient strength or use wood screws or anchor screws that do not have sufficient strength to reliably resist pulling out. · When installing the ceiling mount unit on ceiling construction members, use commercially available 10mm nominal diameter screws that are appropriate for the construction members. Wood screw Ceiling beam 10mm nominal dia. bolt, spring washer, washer, nut (4 each) CAUTION Avoid installing in locations where the temperature and humidity are excessively high, and where contact with water is possible. These can result in fire or electrical shock. 10cm or more 10cm or more 10cm or more Do not block the ventilation holes. Also provide 10cm sufficient clearance or more in regard to the surroundings to avoid blocking the ventilation. The internal temperature could elevate and possibly result in fire. -2- CAUTION Do not install close to an airconditioner intake or outlet. Do not install in locations where there is excessive amounts of dust, oily smoke or tobacco smoke. Fire could result. Do not install near sprinklers or sensors. This could result in misoperation or electrical shock. Do not install in locations where there is excessive vibration or impact. Injury and damage could result from falling. ,,,,,,,,,,,, Install only on a ,,,,,,,,,,,, horizontal surface. ,,,,,,,,,,,, ,,,,,,,,,,,, Avoid sloped ,,,,,,,,,,,, surfaces. Also, do not ,,,,,,,,,,,, install facing upward. The internal temperature could elevate and possibly result in fire. Injury or damage could also result from falling. Installing WARNING Firmly install coupling pins, snap pins and screws in the prescribed locations. Failure to do so could result in the plasma display dropping. Make sure the plasma display mount fittings and angle adjustment unit are firmly engaged. Failure to do so could cause the plasma display to fall. Do not loosen or remove hex head screws. This could result in insecure installation and dropping. Do not alter any of the parts. And do not use broken parts. This could result in injury due to the plasma display falling. Always use at least two people to perform the installation work. Injury could result from dropping heavy objects. -3- Installation Method Installation space While referring to the dimensional drawing for the ceiling mount unit, decide an installation location where the ceiling strength is sufficient. Also, set the height adjustment position, screen tilt angle and horizontal angle of the ceiling mount unit beforehand. CMP401X 418 549 45 45 180 (307) (121) (P60x3) 549 366 235 25 Screen center 742 940 97 55 CMP402HD 451 583 45 45 180 (P60x3) 583 977 (274) (121) 314 25 319 Screen center 1041 648 89 55 -4- 969 CMP307X 513 398 45 45 180 (284) (121) (P60 x 3) 513 337 291 25 Screen center 684 884 100 55 Ceiling mount unit dimensions 330 300 Pipe dia. 61mm 300 330 Four 12mm dia. holes Adjustment range Height adjustment: 180mm (P60 x 3 steps) Downward tilt angle adjustment: 0, 5, 10, 15, 20, 25 (6 steps) Horizontal angle adjustment: 45 degrees left or right (continuous) -5- 975 Installing the ceiling mount unit 1. Disassembly · Slightly loosen the 4 lock screws and 1 rotation stopper screw. Merely slightly loosen the above screws. Do not remove them. · Pull out the 2 snap pins and the 2 coupling pins. · Separate the ceiling mount unit and angle adjustment unit. Ceiling mount unit remove the 2 coupling pins. Remove the 2 snap pins. Loosen the 4 lock screws. Loosen the 1 rotation stopper screw. Angle adjustment unit (Front) (Back) 2. Downward tilt angle adjustment · Remove 1 M6 x 18 screw from each side of the angle adjustment unit. Align the hole for the necessary screen tilt angle and then tighten the M6 x 18 screws. Be sure that both the left and right sides are set to the same angle. M6 X 18 screw 3. Installing on the ceiling · Pass the wiring cable through the ceiling mount unit as necessary. · Install the ceiling mount unit on the ceiling with the cable hole facing the back. · For the ceiling, use commercially available bolts, washers and nuts that are appropriate for the ceiling construction. Mounting hole: 12mm dia. 0 30 30 0 M10 bolt Flat washer Spring washer Nut Cable hole Ceiling mount unit Wiring cable -6- 4. Installing the angle adjustment unit 1. Pass the wiring cables through the pipe, then insert the angle adjustment unit into the ceiling mount unit. Adjust the height so that the red mark on the pipe is not visible and then insert the two coupling pins. Have two coupling pins inserted into the linkage holes in the angle adjustment unit. 2. Insert snap pins into the holes in the ends of the coupling pins. 3. Tighten the 4 lock screws. 4. Adjust the horizontal angle of the screen. 5. Tighten the one rotation stopper screw. Red mark 2.Insert 2 snap pins. Ceiling mount unit 3.Tighten the 4 lock screws. 1.Insert the 2 coupling pins Linkage hole 5.Tighten the rotation stopper screw. Angle adjustment unit This could cause the plasma display to fall if it is assembled to make the red mark visible. 4.Adjust the horizontal angle. Mounting the display mounting fittings on the plasma display CMP401X 1. Remove the stand. 1. Place a protective sheet cover on the top of a table and place the plasma display on the cover with the back side upward. 2. Remove the screws fastening the column and pull the column out in the direction indicated by the arrow mark. 3. Remove the 4 screws fastening the stand and remove the stand in the direction indicated by the arrow mark. Remove 4 screws. Column Stand Remove the screws. CMP401X plasma display Stand Table -7- 2. Installing the CMP401X supports · Fasten the two supports to the back of the plasma display with 4 M4 X 12 screws. M4 X 12 screws (2 each) 3. Installing the display mounts · fasten the two display mounts to the back of the plasma display with 6 M6 X 18 screws. M6 X 18 screws (3 each) The top hole of the display mount. Display mount The top hole of the plasma display. Support fittings The 3rd display mount hole from the top. The 6th display mount hole from the top. Align the protrusion of the support with the outer hole. CMP402HD 1. Remove the top case of the cardboard box and the polyethylene bag. 2. Mounting the display mount. · Mount the display mounting fixtures (left / right) on the back of the plasma display unit with the bent part facing inward, then fasten with six M6 X 18 screws. Display mount (right) M6 X 18 screws (3 each) Display mount (left) 2nd display mount hole from the top. 4th hole from the top. 5th hole from the top. CMP307X 1. Remove the stand. · Remove the top case of the cardboard box and the polyethylene bag. When a stand is attached to the plasma display, remove the four screws and detach the stand. CMP307X plasma display Remove 4 screws. and remove the stand. 2. Mounting the display mount. · Mount the display mounting fixtures (left / right) on the back of the plasma display unit with the bent part facing inward, then fasten with six M6 X 18 screws. Display mount (right) M6 X 18 screws (3 each) 2nd display mount hole from the top. Display mount (left) 2nd plasma display hole from the top. Stand -8- Installing the plasma display on the angle adjustment unit To fasten the plasma display to the ceiling mount unit, engage the four pins of the angle adjustment unit in the four cutouts of the display mount fitting on the back of the plasma display. Next, tighten the two screws from the bottom. When installation is complete, fasten the wiring cable with cable clamps as necessary. Pin Make sure that the pins and cutouts at both the top and bottom are firmly engaged. Angle adjustment unit · The plasma display should always be carried by at least two persons. · Disconnect all of the plasma display power cords and cables. Make sure that the angle adjustment unit holes and display mount fitting screw holes are aligned before tightening the screws. Cutout Cable clamp Display mount fitting M6 X 18 screw -9- Product Specifications External Dimensions Four 12mm dia. holes 180 (P = 60 X 3 steps) 633 (CMP402HD screen center) 628 (CMP307X screen center) 300 330 601 (CMP401X screen center) 55 61 5s ees X 5 degrgrees 25 de teps = 969 454 Mass Main material 14kg Steel sheet Surface treatment Black electrodeposited baked paint Angle adjustment 0, 5, 10, 15, 20, 25 degrees (6 steps) Horizontal angle 45 degrees (continuous) adjustment Vertical (tilt) angle 180mm (P60mm X 3 steps) adjustment Products mounted Hitachi Plasma Displays CMP401X, CMP402HD and CMP307X Hitachi, Ltd. Tokyo Japan Digital Media Systems Division 2-15-12 Nishi-Shimbashi, Minato-ku, Tokyo, 105-8430, Japan (Hitachi Atago Annex) (03) 3502-2111 3 Printed in Japan (JE) ...

  Know our Partners   Frequently Asked Questions   Contact Diplodocs team   Last searches
Latest additions
  Sitemap
Brands starting with A B C D E F G H I J K L M N O P Q R S T U V W X Y Z #
Copyright © 2005 - 2008 - Diplodocs - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.