User manual HONEYWELL CT3451
Diplodocs help download the user guide HONEYWELL CT3451.
This product, although classified under the brand HONEYWELL, may have been manufactured by ADEMCO, DOMONIAL, ENVIRACAIRE, FBII, FISHER PRICE, GALAXY, INTELLISENSE, RELI ON after mergers, acquisitions, or a change in name.
Preview of the first 3 pages of manual
You either have JavaScript turned off or an old version of Adobe Flash Player Get the latest Flash Player.
User guide HONEYWELL CT3451
Detailed instructions for use are in the User's Guide. CT3451 Programmable Thermostat
OWNER'S GUIDE
If this control is replacing a control that contains mercury in a sealed tube, do not place your old control in the trash. Dispose of it properly. Contact your local waste management authority for instructions regarding recycling and the proper disposal of an old control.
MERCURY NOTICE
1 PREPARE FOR INSTALLATION
Programmable Heat and/or Cool Low Voltage (20 to 30 Vac) Thermostat and Wallplate Congratulations on the purchase of your new thermostat! More than 100 years of Honeywell engineering produced this thermostat that can provide you with a more comfortable and convenient living environment. Your new thermostat automatically controls the temperature in your home, keeping you comfortable while saving energy when programmed according to these instructions. Direct questions about this thermostat to our Web site at www.honeywell.com/yourhome or call the customer information line at 1-800-468-1502.
WIRE CUTTER/STRIPPER IF NEEDED TO STRIP WIRES SCREWDRIVER HAND OR POWER DRILL WITH 3/16 INCH DRILL BIT, IF NEEDED TO DRILL HOLES IN WALL
Check Table 1 to make sure this thermostat is compatible with your system. If not, return it to the retailer. Acquire tools and items, as needed. See Fig. 1.
MERCURY SWITCH
LEVEL, IF NEEDED TO LEVEL THERMOSTAT FOR APPEARANCE
M20551
Fig. 1. Required installation tools/supplies.
TYPICAL LOCATION OF A MERCURY SWITCH IN A THERMOSTAT
M10614
® U.S. Registered Trademark Copyright © 2003 Honeywell ·
·All Rights Reserved
69-1620-1
CT3451 PROGRAMMABLE THERMOSTAT
2 REMOVE OLD THERMOSTAT
Test to be sure your heating and air conditioning systems (where applicable) are working correctly. If not, contact your local heating/air conditioning dealer. To avoid compressor damage, do not operate the cooling system when outdoor temperature is below 50°F (10°C).
Table 1. Compatibility Chart. System Type Gas--standing pilot Gas--electronic ignition Gas-fired boilers Gas--750 millivolt Oil-fired boilers Oil-fired furnace Electric furnace Electric air conditioning Single stage heat pumps (no backup or auxiliary heat) Baseboard electric (120/240 line volt) Multistage heat pumps/multistage equipment Yes Yes Yesa Yes Yesa Yes Yes Yes Yes No No Compatible With CT3451
aCompatible
Not compatible with any 120/240 volt circuit. with 2-wire Honeywell zone valves. Isolating relay required for zone valves that have a 3-wire thermostat connection.
CAUTION
Equipment Damage Hazard. Handling wires during installation can damage equipment. Disconnect power at furnace or main breaker/ fuse box before beginning installation.
Replacing Clock WIth C or C1 Clock Terminals
If you are replacing a Honeywell Chronotherm® Thermostat, you may find one or two wires that go to the C or C1 clock terminals on the Chronotherm® Thermostat wiring wallplate. Do not allow them to touch, or you can damage your transformer. Disconnect the wires and wrap them separately using electrical tape; do not wrap them together. Do not place the wires where they can interfere with the new thermostat operation. Record the colors and terminal designation labels of the remaining wires.
Carefully unpack your new thermostat and wallplate and save package of screws, instructions and receipt. Remove the cover from the old thermostat. If it does not snap off when pulled firmly from the bottom, check for screw that locks on the cover. Loosen screws holding thermostat to subbase, wallplate or wall and lift away. Disconnect wires from old thermostat or subbase. As you disconnect each wire, use the wiring labels (enclosed) to label each wire with the old terminal designation. If there are only two wires, they do not require labeling. Wrap wires around a pencil to keep them from falling back into the wall as shown in Fig. 2.
WIRES THROUGH WALL OPENING
Six or More Thermostat Wires
If there are six or more wires connected to the thermostat (excluding clock wires attached to terminals), you probably have a variation of a multistage heat pump or other multistage system. The thermostat is not compatible with these systems, so return the product to your retailer. If you want information about which programmable thermostats work with your system, visit our Web site at www.honeywell.com/yourhome or call the customer information line at 1-800-468-1502.
Three Thermostat Wires
M5136
Fig. 2. Wrapping wires around pencil.
If you have three wires for heating only and can operate the fan using the Fan On switch, this thermostat works with your system. However, some hot water (zoned) heating systems have three thermostat wires. The thermostat works only if a contractor installs an isolating relay on these systems. For details, contact a local heating/cooling contractor.
2
69-1620--1
CT3451 PROGRAMMABLE THERMOSTAT
3 MOUNT WALLPLATE
IMPORTANT Level for appearance only. The thermostat functions normally even when not mounted level. Position the wallplate on the wall. Level the wallplate for appearance, if desired. Use a pencil to mark the two mounting holes that best fit the application. See Fig. 3.
TERMINAL SCREW FOR STRAIGHT INSERTION STRIP 5/16 IN. (8 MM) FOR WRAPAROUND STRIP 7/16 IN. (11 MM)
G
Rc R
WALL 1
WALL ANCHORS (2)
W B Y O
M12559A
Fig. 4. Connecting wiring.
MOUNTING SCREWS (2) 1 WALLPLATE
WHEN USING WALL ANCHORS, DRILL 3/16 INCH HOLES FOR DRYWALL, 7/32 INCH HOLES FOR PLASTER OR WOOD.
NOTE: To ensure correct mounting of thermostat, restrict all wiring to the shaded area in the center of the terminals. Loosen the terminal screws and slip each wire beneath its matching terminal. The shape of the terminals permit insertion of straight or wraparound connections. See Fig. 5. Tighten the terminals.
M12202A
Fig. 3. Mounting wallplate to wall. Remove the wallplate from the wall and drill two 3/16in. holes in the wall (if drywall). For firmer wall material such as plaster or wood, drill 7/32-in. holes. Gently tap provided anchors into the drilled holes until flush with the wall. Reposition the wallplate, pulling wires through the wiring opening. Loosely insert the mounting screws into the holes. Level for appearance only; the thermostat functions correctly even when not level. Tighten the mounting screws.
FOR WRAPAROUND, STRIP 7/16 IN. (11 mm)
FOR STRAIGHT INSERTION, STRIP 5/16 IN. (8 mm)
4 WIRE WALLPLATE TERMINALS
M12537
All wiring must comply with local electrical codes and ordinances. If unsure about household wiring procedures, call your local heating and air conditioning contractor. Refer to the labels you placed on wires when you removed your old thermostat. Match the letter of your old thermostat wire with the terminal of the corresponding letter on your new thermostat. Refer to Fig. 4.
Fig. 5. CT3451 methods for wiring connection. Plug the hole in the wall with insulation to help prevent drafts from adversely affecting thermostat operation. The CT3451 Thermostat is powered with 3AA alkaline batteries and is adaptable to most 18 to 30 Vac heatingcooling systems. Refer to Fig. 6 through 10 for typical system wiring diagrams.
3
69-1620--1
CT3451 PROGRAMMABLE THERMOSTAT
THERMOSTAT G Rc R W B Y O HEAT RELAY 1 L1 (HOT) L2 TRANSFORMER 1 POWER SUPPLY. PROVIDE DISCONNECT MEANS AND OVERLOAD PROTECTION AS REQUIRED. CAN BE USED FOR CHANGEOVER VALVE ON SINGLE-STAGE HEAT PUMP SYSTEMS. JUMPER R TO Rc.
M20510
THERMOSTAT G Rc
3
R W B Y 2 O
FAN COIL
COOL DAMPER
2 1 L1 (HOT) L2 1
FAN RELAY
COMPRESSOR CONTACTOR
HEAT DAMPER
COOLIING CONTRACTOR COIL 24V
POWER SUPPLY. PROVIDE DISCONNECT MEANS AND OVERLOAD PROTECTION AS REQUIRED.
M20537
2 3
Fig. 8. Typical cool system hookup with 3-wire, cool-only system.
Fig. 6. Typical heat-cool system hookup with single transformer.
THERMOSTAT G Rc
THERMOSTAT G Rc R W B Y O
1 L1 (HOT) L2 COOLING TRANSFORMER 1 FAN RELAY
R W
2 B
Y O
3 COOL DAMPER
3 HEAT DAMPER HEAT RELAY 1 L1 (HOT) L2 HEATING TRANSFORMER
COMPRESSOR CONTACTOR
1 24V
HEATING RELAY AND FAN COIL
POWER SUPPLY. PROVIDE DISCONNECT MEANS AND OVERLOAD PROTECTION AS REQUIRED. REMOVE RC TO R JUMPER WHEN INSTALLED ON A TWO TRANSFORMER SYSTEM. CAN BE USED FOR CHANGEOVER VALVE ON SINGLE-STAGE HEAT PUMP SYSTEMS. M20511
1
POWER SUPPLY. PROVIDE DISCONNECT MEANS AND OVERLOAD PROTECTION AS REQUIRED.
M20536
2 3
Fig. 7. Typical heat system hookup with 2-wire, heatonly system.
Fig. 9. Typical heat-cool system hookup with two transformers.
69-1620--1
4
CT3451 PROGRAMMABLE THERMOSTAT Swing down the thermostat and press the lower edge of the thermostat onto the wallplate to latch. See Fig. 12.
DASHED LINES INDICATE TABS ON BACK OF THERMOSTAT
T8002 THERMOSTAT G Rc R W 4 FAN RELAY Y 2 B O COOL CHANGEOVER VALVE 1 L1 (HOT) L2 TRANSFORMER 1 POWER SUPPLY. PROVIDE DISCONNECT MEANS AND OVERLOAD PROTECTION AS REQUIRED. JUMPER Y TO W. JUMPER R TO Rc. USE EITHER O OR B FOR HEAT PUMP CHANGEOVER.
M20512
3
Hold Sele ct
COMPRESSOR CONTACTOR
HEAT CHANGEOVER VALVE
FA Auto N On
Coo SYSTE l Off M Hea
t
2 3 4
A ENGAGE TABS AT TOP OF THERMOSTAT
WITH SLOTS ON WALLPLATE.
Fig. 10. Typical single-stage heat pump system hookup.
TUE
PM
Hold Selec t
5 ADJUST FAN OPERATION SWITCH
The thermostat fan operation switch, labeled fuel switch in Fig. 11, is set at the factory in the F (gas/oil fuel) position. This is the correct setting for most systems. If you have an electric heat system, set the switch to the E (electric) position. The E setting allows the fan to turn on immediately with the heating equipment in a system where the G terminal is connected.See Fig. 11.
FA Auto N On
Coo SYSTE l Off M Hea
t
B PRESS LOWER EDGE OF
CASE TO LATCH.
M20513
Fig. 12. Mounting thermostat to wallplate.
7 INSTALLING AND REPLACING BATTERIES
E F
FAN OPERATION (FUEL) SWITCH
M20530
The thermostat requires three AA alkaline batteries to operate: Remove the battery door, located on the right side of the thermostat, by pulling outward from the bottom. See Fig. 13. Insert three AA alkaline batteries as shown in Fig. 13. NOTE: The thermostat shows a "bAtLo" message on the digital display to alert the homeowner one to two months before the batteries run out completely. IMPORTANT Homeowner should replace the batteries once a year to prevent leakage and/or the heating/cooling system from shutting down due to lack of battery power in the thermostat.
Fig. 11. Fan operation (fuel) switch.
6 MOUNT THERMOSTAT TO WALLPLATE
Slide System switch to the Off position. Engage the tabs at the top of the thermostat and wallplate.
5
69-1620--1
CT3451 PROGRAMMABLE THERMOSTAT --
AA BATTERIES (3)
Release the keys to display the three-digit software revision code. (Information displayed varies by model).
PM
TUE
Hold Selec t
M12583
FA Auto N On
--
Coo SYSTE l Off M Hea t
Press the key. FC (factory configuration) displays. (A typical example is shown, but information displayed varies by model. This information is for factory use only.)
M20514
Fig. 13. Installing batteries. Restore power to the heating/cooling system.
M12584A
8 CUSTOMIZE YOUR THERMOSTAT
Your Honeywell thermostat comes preset to the most commonly used settings: -- Temperature (°F). -- Gas or oil forced air furnace. -- Aggressive algorithm control. You can change these settings using the instructions that follow. To exit at any time, press the key until End displays.
Setting °C or °F. -- Press the key again to display the current setting. -- Press the key to change the °C or °F indication. Setting Heat Cycle Rate (see Table 2 for the cycle rate options and equipment). -- Press the key to display the current heat cycle rate setting of 1, 3, 4, 5, 9, or 12 cph.
M12589A
--
Setting °F/°C Indication, Heat Cycle Rate, Heating/Cooling Temperature Control
The following instructions provide information to change the heating cycle rate to match the heating equipment and to choose either the Fahrenheit (°F) or Celsius (°C) display. NOTE: All four steps must be completed to save changes to the °F/°C indication and the heat cycle rate. Enter Installer Setup. -- Use or keys to set the temperature setpoint to 52°F (11°C).
SET
If the desired cycle rate is displayed, press the key to display heating and cooling algorithm default.
M12588A
-- --
To change the heat cycle rate, press the key until your choice of 1, 3, 4, 5, 6, 9, or 12 is displayed. Press the key to display the heating and cooling temperature control algorithm configuration default.
HT.
M14691 M12582A
--
--
Press and keys simultaneously for more than two seconds to enter Installer Setup.
Press the key to change the heating and cooling control algorithm to C1 or C3. C1 = Standard control algorithm. C3 = Aggressive control algorithm (Default. Can cause overshooting.)
69-1620--1
6
CT3451 PROGRAMMABLE THERMOSTAT -- Press the key. Current configuration (CC) is displayed. A typical example is shown, but CC varies by model. (This information is for factory use only.) NOTE: The heating and cooling program times are the same. Changing your cooling Wake time also changes your heating Wake time. Leave is the time period you can set for an energy saving temperature while you are away from home during the day. Return is the time period when you want the house at a comfortable temperature when you come home during the day. Sleep is the time period when you can set an energysaving temperature while you are sleeping. IMPORTANT Always press the keys with your fingertip or similar blunt tool. Sharp instruments like pens and pencil points can damage the keyboard.
PM
M14692
Exit Installer Setup. -- Press the key to save all changes and return to normal operation.
Setting Current Time and Day
M12590A
1.
To set current time, press Select twice. Press or key to set current time.
Table 2. Heating Cycle Rate. System Steam, gravity Hydronic heat, condensing gas furnacesa Gas or oil forced air (default) Electric heat Special applications
aHigh
NOTE: While setting the current time, the word SET is displayed.
Cycle Per Hr 1 3 6 9 4, 5, 12
SET
PM
M12591A
2.
To set day of week, press Select again. Press or key to set current day.
SET
bRefer
efficiency furnace (90+). to the equipment manufacturer's instructions.
M18534
9 PROGRAM YOUR THERMOSTAT
The thermostat is preprogrammed for your convenience with the following time and temperature settings; see Table 3. See energy saving charts at the end of this document for energy-saving information.
To use the preprogrammed time and temperature settings (see Table 3), press Hold to exit the programming mode.
Setting Weekday Program
Slide the System switch to the position, Heat or Cool, that you want to program. A flame (heating) or a snowflake (cooling) appears in the right side of the display, when setting the program temperature. 1. Wake a. Press Select. Press or key to set Wake time.
SET
Table 3. Preprogrammed Time and Temperature Settings. Period Wake Leave Return Sleep Time 6:00 AM 8:00 AM 6:00 PM 10:00 PM Heat Setpoint 70°F (21°C) 62°F (17°C) 70°F (21°C) 62°F (17°C) Cool Setpoint 78°F (26°C) 85°F (29°C) 78°F (26°C)
M18570
82°F (28°C)
b. Press Select. Press or key to set Wake temperature.
Wake is the time period when you want the house at a comfortable temperature when you get up in the morning.
7 69-1620--1
CT3451 PROGRAMMABLE THERMOSTAT
Setting Saturday and Sunday Programs
SET
To set the Saturday program: 1.
M12625C
Wake a. Press Select. Press or key to set Wake time.
SET
2.
Leave. a. Press Select. Press or key to set Leave time.
SET
M20558
b. Press Select. Press or key to set Wake temperature.
M18566
b. Press Select. Press or key to set Leave temperature.
SET
SET
M20559
2.
M12627B
Leave a. Press Select. Press or key to set Leave time.
SET
3.
Return a. Press Select. Press or key to set Return time.
SET
M20560
b. Press Select. Press or key to set Leave temperature.
M18567
b. Press Select. Press or key to set Return temperature.
SET
SET
M20561
3.
M12629B
Return a. Press Select. Press or key to set Return time.
SET
4.
Sleep a. Press Select. Press or key to set Sleep time.
SET
M20562
b. Press Select. Press or key to set Return temperature.
M18568
b. Press Select. Press or key to set Sleep temperature.
SET
SET
M20563
M12631C
69-1620--1
8
CT3451 PROGRAMMABLE THERMOSTAT 4. Sleep a. Press Select. Press or key to set Sleep time.
SET
Setting Indefinite Temperature Hold
The Hold key allows you to indefinitely hold a temperature. When Hold is active, the letters Hld are displayed continuously. Hold can be canceled by pressing the Hold key again. Press Hold. Press or key to set indefinite temperature setting.
M20564
b. Press Select. Press or key to set Sleep temperature.
SET
M12641A
M20565
5. 6.
Repeat steps 1-4 in Setting Saturday and Sunday Program section to set the Sunday program. Press Select. End is displayed. Programming is complete. The thermostat reverts to displaying the current day time and temperature in five seconds.
SET
11 SET FAN AND SYSTEM SWITCHES
Manually control Fan and System settings using the switches located at the bottom of the thermostat case. See. Fig. 14 for switch locations.
M18556
7.
Repeat programming steps to set heat or cool program, as desired.
PM
TUE
Hold Selec t
10 OPERATE YOUR THERMOSTAT
Displaying Temperature Setting
Press or key once to display present temperature setting. After approximately five seconds, the thermostat displays the current time and room temperature.
SET TEMPORARY
FA Auto N On
Coo SYSTE l Off M Hea t
M20515
Fig. 14. Time/temperature display and System/Fan switches.
Fan Switch
M20538
The Fan switch settings are: On: The fan runs continuously. Use for improved air circulation. Auto: Normal setting for most homes. In cooling, the fan starts and stops with the cooling equipment. In heating, the fan is controlled directly by the heating equipment and starts a few minutes after the heating equipment turns on (on most systems). When the thermostat fuel switch is set to the E position for electric heat, the fan starts and stops with the heating equipment. Slide the Fan switch on the thermostat to the desired fan setting.
Setting Temporary Temperature Hold
Press or key to set a temporary temperature setting.
TEMPORARY
PM
WED
M12640A
NOTE: The temporary temperature setting remains in effect until the next program period. To cancel, press Hold twice.
9
69-1620--1
CT3451 PROGRAMMABLE THERMOSTAT
System Switch
The System switch settings control thermostat operation as follows: Cool: The thermostat controls the cooling system. Off: Both heating and cooling are off. Heat: The thermostat controls the heating system. Slide the System switch on the thermostat to the desired system setting.
with the Fuel switch set to the E position for electric heat, the fan starts immediately. Press the key to lower the temperature setting below the room temperature. The heating equipment should shut down.
Cooling System
Heat and Cool Indicators
indicates a call for heat. indicates a call for cool. NOTE: In the programming mode, the the indicate System setting. and
CAUTION
Minimum Off-Timer
The thermostat minimum off-timer assures that the compressor does not come on again for at least five minutes after it turns off. The minimum off-timer is triggered when the compressor turns off and when the System switch position is changed. If the compressor turns off when the setpoint is changed, the minimum off-timer is triggered. A flashing snowflake is in effect. indicates the minimum off-timer
Compressor Damage Hazard. Operating at too low of an outdoor temperature can cause compressor damage. Do not operate cooling if outdoor temperature is below 50°F (10°C). Allow compressor to remain off for five minutes before restarting. Refer to manufacturer's recommendations.
1. 2.
Slide the System switch to Cool and the Fan switch to Auto. Press the key to lower the temperature setting several degrees below the room temperature; the cooling equipment should start. The fan starts and stops with the cooling equipment.
NOTE: If the cooling system does not start immediately, remember that the thermostat has a built-in minimum off-time of five minutes to protect the compressor. 3. Press the key to raise the temperature setting above the room temperature. Cooling system should shut down.
12 CHECK OPERATION AFTER INSTALLATION/PROGRAMMING
Heating System
Slide the System switch to Heat and the Fan switch to Auto. Press and hold the key to raise the temperature several degrees above the room temperature to start the heating equipment. When using the thermostat
Fan
Slide the System switch to Off and the Fan switch to On. The fan should run continuously. Slide the Fan switch to Auto. The fan should turn off.
Backlighting
Press any key to light the display for approximately ten seconds.
69-1620--1
10
CT3451 PROGRAMMABLE THERMOSTAT
TROUBLESHOOTING
Table 4. Frequently Asked Questions. If ... Display does not come on. Temperature display does not go lower than 40°F (4°C) or higher than 99°F (37°C during programming. Display shows flashing or steady "bAtLo." Temperature change occurs at the wrong time. Heating does not come on. Then ... Make sure the batteries are fresh and installed correctly. Your thermostat has reached the temperature limit. Be sure the setting range is from 40°F to 99°F (4°C to 37°C). The batteries are low; replace them as soon as possible. Check the program times for the period in question. Be sure that AM and PM indications are correct. Make sure the current day and time are correct. Reprogram if necessary. · Check that the System switch is set to Heat. · Check the system fuse or circuit breaker and replace or reset, if necessary. · Check for correct wiring and good connections. · If display is blank or displays "bAtLo," install fresh batteries. · Allow time for the furnace to heat up and the fan to come on before checking for heat at the register. · If the temperature setting is higher than the current room temperature and the flame is displaying, the thermostat is operating correctly. Contact a heating contractor for assistance. · Check that the System switch is set to Cool. · Check the system fuse or circuit breaker and replace or reset, if necessary. · Check for correct wiring and good connections. · If display is blank or says "bAtLo," install fresh batteries. · The thermostat has a built-in time delay on cooling. Allow five to ten minutes after changing the setting before the air conditioner starts. · If the temperature setting is lower than the current room temperature and the snowflake is displaying, the thermostat is operating correctly. Contact an air conditioning contractor for assistance. Adjust heat cycle rate in the Customize Your Thermostat section. · Plug the wiring hole in the wall behind the mounting plate with insulation to prevent drafts that can adversely affect thermostat operation. · Be aware that it is normal for the current setting and the displayed room temperature to differ occasionally. · During recovery from setback or setup, setting and displayed room temperatures can differ for up to 30 minutes after recovery period. Wait five minutes after seeing the flame or snowflake and check the registers again. If there is no hot or cool air coming from the registers, refer to "Heating does not come on" or "Cooling does not come on." If everything is checked contact you heating and air conditioning contractor. · Wait until Replace Battery indicator is illuminated and replace batteries. · Replace batteries now. · MInimum off-timer is in effect. Wait five minutes until the minimum off-timer is complete.
Cooling does not come on.
The furnace cycles too frequently or the system cycle length is too short or too long. The thermostat current setting does not match the displayed room temperature to within plus or minus 1°.
System on indicator ( = heat; = cool) is lighted, but no warm or cool air is coming from the registers.
Thermostat backlight appears dim.
System on indicator
is flashing.
11
69-1620--1
CT3451 PROGRAMMABLE THERMOSTAT
PERCENT OF HEATING COSTS YOU CAN SAVE
SAVINGS FOR ONCE-A-DAY 10°F (5°C) DECREASE* 6 TO 9 12 14 16 TO TO TO TO 8% 11% 13% 15% 18% HEAT
PERCENT OF COOLING COSTS YOU CAN SAVE
SAVINGS FOR ONCE-A-DAY 10°F (5°C) INCREASE* COOL 7 TO 9% 10 TO 11% 12 TO 14% 14 TO 19%
* YOUR SAVINGS DEPENDS ON HOME SIZE AND ACTUAL HEAT LOSS OR GAIN, GEOGRAPHIC LOCATION, FREQUENCY OF TEMPERATURES CHANGE, AND RANGE IN DEGREES OF CHANGE.
M12545
Limited One-Year Warranty
Honeywell warrants this product, excluding battery, to be free from defects in the workmanship or materials, under normal use and service, for a period of one (1) year from the date of purchase by the consumer. If, at any time during the warranty period, the product is defective or malfunctions, Honeywell shall repair or replace it (at Honeywell's option) within a reasonable period of time. If the product is defective, (i) return it, with a bill of sale or other dated proof of purchase, to the retailer from which you purchased it, or (ii) package it carefully, along with proof of purchase (including date of purchase) and a short description of the malfunction, and mail it, postage prepaid, to the following address: Honeywell Return Goods Dock 4, MN10-3860 1885 Douglas Dr N Golden Valley, MN 55422 Canada: Honeywell Limited/Honeywell Limitée Product Services ON15 35 Dynamic Dr Scarborough, Ontario M1V 4Z9
This warranty does not cover removal or reinstallation costs. This warranty shall not apply if it is shown by Honeywell that the defect or malfunction was caused by damage which occurred while the product was in the possession of a consumer. Honeywell's sole responsibility shall be to repair or replace the product within the terms stated above. HONEYWELL SHALL NOT BE LIABLE FOR ANY LOSS OR DAMAGE OF ANY KIND, INCLUDING ANY INCIDENTAL OR CONSEQUENTIAL DAMAGES RESULTING, DIRECTLY OR INDIRECTLY, FROM ANY BREACH OF ANY WARRANTY, EXPRESS OR IMPLIED, OR ANY OTHER FAILURE OF THIS PRODUCT. Some states do not allow the exclusion or limitation of incidental or consequential damages, so this limitation may not apply to you. THIS WARRANTY IS THE ONLY EXPRESS WARRANTY HONEYWELL MAKES ON THIS PRODUCT. THE DURATION OF ANY IMPLIED WARRANTIES, INCLUDING THE WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE, IS HEREBY LIMITED TO THE ONE YEAR DURATION OF THIS WARRANTY. Some states do not allow limitations on how long an implied warranty lasts, so the above limitation may not apply to you. This warranty gives you specific legal rights, and you may have other rights which vary from state to state. If you have any questions concerning this warranty, please write Honeywell Customer Relations, 1985 Douglas Dr N, MN10-1461, Golden Valley, MN 55422. In Canada, write Retail Products ON15, Honeywell Limited/Honeywell Limitée, 35 Dynamic Dr, Scarborough, Ontario M1V 4Z9.
Automation and Control Solutions
Honeywell 1985 Douglas Drive North Golden Valley, MN 55422 Honeywell Limited-Honeywell Limitée 35 Dynamic Drive Scarborough, Ontario M1V 4Z9
69-1620--1 J.S. 05-03
Printed in U.S.A. on recycled paper containing at least 10% post-consumer paper fibers.
www.honeywell.com/yourhome
If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Diplodocs provides you a fast and easy access to the user manual HONEYWELL CT3451. HONEYWELL offer a product for which we do not have the user manual? Let us know what you are looking for: site Internet, histoire, actualité, filiales, site Internet, mode d'emploi, driver, avis des utilisateurs, meilleur prix des produits, forum d'assistance aux problèmes, annuaire des marques, annuaire des constructeurs, répertoire des marques, répertoire des constructeurs, site Internet de la marque, site Internet du constructeur Diplodocs allows you to download user manual HONEYWELL CT3451, user guide HONEYWELL CT3451, instructions HONEYWELL CT3451, owner's manual HONEYWELL CT3451, online manual HONEYWELL CT3451.Access web reviews HONEYWELL CT3451, , |
![]() |
Include the add-on to download manuals from your site, forum or blog | ![]() |
Frequently Asked Questions | ![]() |
Contact Diplodocs team | ![]() |
Last searches Last additions |
![]() |
Sitemap | ![]() |
|||
| Brands starting with A B C D E F G H I J K L M N O P Q R S T U V W X Y Z # | |||||||||||||
|
|
Copyright © 2005 - 2008 - Diplodocs -
All Rights Reserved. Designated trademarks and brands are the property of their respective owners. |