9 562 brands
2 694 000 user's guides


Download your manual, it's FREE! Diplodocs allows you to download several types of document in order to best use your HONEYWELL CT3697 : user manual, user guide, instruction manual.
Search a brand
Advanced Search

Need help using a product?
Look at the reviews on HONEYWELL CT3697

User manual HONEYWELL CT3697

Diplodocs help download the user guide HONEYWELL CT3697 .

Download the complete user guide (556 Ko)



This product, although classified under the brand HONEYWELL, may have been manufactured by ADEMCO, DOMONIAL, ENVIRACAIRE, FBII, FISHER PRICE, GALAXY, INTELLISENSE, RELI ON after mergers, acquisitions, or a change in name.



Preview of the first 3 pages of manual

You either have JavaScript turned off or an old version of Adobe Flash Player
Get the latest Flash Player.
Manual abstract: user guide HONEYWELL CT3697

Detailed instructions for use are in the User's Guide.

Honeywell CT3600/CT3697 OWNER'S GUIDE Seven Day Programmable Heat and/or Cool Low Voltage (20 to 30 Vac) Thermostat and Wallplate Model CT3600/CT3697 Para obtener un documento con las instrucciones en español, por favor visite nuestro sitio de web a: www.honeywell.com/yourhome. Pour obtenir des notices techniques en français, veuillez consulter notre site web www.honeywell.com/yourhome. PROGRAMMABLE THERMOSTAT Contents Step 1. Prepare for Installation ................................................................................................................................... Step 2. Remove Old Thermostat ................................................................................................................................ Step 3. Mount Thermostat Wallplate .......................................................................................................................... Step 4. Wire Wallplate Terminals ................................................................................................................................ Step 5. Install the Batteries ......................................................................................................................................... Step 6. Set Fan Operation Switch .............................................................................................................................. Step 7. Mount the Thermostat .................................................................................................................................... Step 8. Customize Your Thermostat ........................................................................................................................... Step 9. Set the Clock .................................................................................................................................................. Step 10. Programming ................................................................................................................................................ Step 11. Operating Your Thermostat .......................................................................................................................... Step 12. Set the Fan and System Switches ............................................................................................................... If You Have a Problem ................................................................................................................................................ Smart ResponseTM Technology .................................................................................................................................. Wiring Diagrams ......................................................................................................................................................... ® U.S. Registered Trademark Copyright © 2002 Honeywell · 5 6 7 8 9 10 11 11 13 14 17 19 20 21 22 ·All Rights Reserved 69-1642 Total comfort temperature management with Smart ResponseTM Technology. Congratulations! You made a smart choice by purchasing your new Honeywell thermostat; the smart thermostat that; · Keeps you comfortable by automatically calculating exactly when the furnace or air conditioning should go on to have the house at the desired comfort temperature by the time you wake up or return home. · Saves the maximum amount of energy and money by automatically remembering to adjust the temperature when you leave home or go to sleep. · Provides the ultimate in comfort and convenience. It comes preprogrammed. You can use the preprogrammed schedule, or set your own. This manual answers many of the questions that can arise as you become familiar and comfortable with your Honeywell thermostat -- the state of the art in home comfort controls. Read these instructions carefully. Failure to follow these instructions can damage the product or cause a hazardous condition. If this thermostat is replacing a control that contains mercury in a sealed tube, do not place your old control in the trash. Contact your local waste management authority for instructions regarding recycling and the proper disposal of this control, or of an old control containing mercury in a sealed tube. MERCURY NOTICE MERCURY SWITCH TYPICAL LOCATION OF A MERCURY SWITCH IN A THERMOSTAT M10614 69-1642 2 TIME /TIME DIGITAL DISPLAY RAISES TEMPERATURE SETTING SETS TIME FORWARD OR BACK SET CURRENT DAY/TIME SETS CURRENT TIME AND DAY LOWERS TEMPERATURE SETTING DISPLAYS RUN PROGRAM RETURNS THERMOSTAT TO NORMAL OPERATING MODE CURRENT HEAT/COOL TEMPERATURE SETTING PROGRAM PERIODS Time Run Program Set Current Day/Time Wake Set Program Leave Return Sleep WAKE/LEAVE/RETURN/SLEEP: ENTERS PROGRAMMING MODE HOLD TEMP SETS A HOLD TEMPERATURE SETTING AND ACTIVATES VACATION HOLD FEATURE Heat Off Cool Hold Temp Day Heat/Cool Settings System On Auto SYSTEM SWITCH SELECTS HEAT/OFF/COOL Daylight Time Copy Usage Fan FAN SWITCH SELECTS AUTO/ON DAY SETS DAY OF THE WEEK HEAT/COOL SETTING COPY COPY SETTINGS FROM ONE DAY TO ANOTHER DAY FOR QUICK PROGRAMMING SWITCHES BETWEEN HEAT SETPOINTS AND COOL SETPOINTS WHILE PROGRAMMING DAYLIGHT TIME SELECTS STANDARD TIME OR DAYLIGHT SAVINGS TIME USAGE TRACKS EQUIPMENT RUNTIME M18635C 3 69-1642 DISPLAYS EITHER CURRENT TIME OF DAY OR PROGRAM TIMES SHOWS WHEN THERMOSTAT IS IN THE PROGRAMMING MODE SHOWS VACATION HOLD DURATION SHOWS THERMOSTAT IS IN THE SET DAY/TIME MODE SHOWS TEMPERATURE SETTING CHANGED FOR THIS PROGRAM PERIOD SHOWS CURRENT DAY OR DAYS BEING PROGRAMMED SHOWS CURRENT PROGRAM PERIOD OR PERIOD BEING PROGRAMMED SHOWS CURRENT SYSTEM KEY POSITION HEAT/OFF/COOL Set Program Hold for AM Em Ht Aux Ht MonTueWedThuFriSatSun Days WakeLeaveReturnSleep In Recovery DST System Off Cool Auto Wait Em Heat Set Day/Time Temporary Setting Room Humid Outdoor Repl Batt SHOWS THE TEMPERATURE DISPLAYED IS THE CURRENT SET TEMPERATURE SHOWS THE TEMPERATURE DISPLAYED IS THE CURRENT ROOM TEMPERATURE SHOWS THE BATTERIES ARE LOW AND MUST BE REPLACED DISPLAYS EITHER ROOM OR SET TEMPERATURES Filter SHOWS THAT THERMOSTAT IS "CALLING" FOR HEAT OR COOL SHOWS SMART RESPONSE IS OFF. CONVENTIONAL RECOVERY IS ON SHOWS SYSTEM ON DAYLIGHT SAVINGS TIME SHOWS THERMOSTAT IS PROCESSING INFORMATION AND WAITING TO CALL FOR HEAT OR COOL SHOWS SMART RESPONSE IS CHANGING THE TEMPERATURE TO MEET THE CURRENT PROGRAMS M16421C 69-1642 4 STEP 1. PREPARE FOR INSTALLATION Check Table 1, the compatibility chart, to make sure the thermostat is compatible with your system. If your system is not compatible, call Honeywell Customer Relations Center, toll-free, 1-800-468-1502. Table 1. Compatibility Chart. System Type Gas -- Standing Pilot Gas -- Electronic Ignition Gas-fired Boilers Gas -- 750 Millivolt Heat onlyb Oil-Fired Boilers Oil-Fired Furnace Electric Furnace Electric Air Conditioning Baseboard Electric (120/240 line volt)c Single Stage Heat Pump Multistage Heat Pumps/Multistage Equipment a b c Compatibility with CT3600/ CT3697 Yes Yes Yesa Yes Yesa Yes Yes Yes No Yes No Compatible with 2-wire Honeywell and Taco zone valves. Not compatible with 3-wire zone valves or 2-wire White Rodgers no. 1361 zone valves. Millivolt system must be heating only. Not compatible with any 120/240 volt system. Thermostat Wiring labels Screwdriver Drill 5 69-1642 · · Wallplate Owner's Guide · Screws and anchors Package Contents · · · · Tools Required STEP 2. REMOVE OLD THERMOSTAT Test your heating and cooling systems to make sure they work properly. If either system does not work, contact your local heating/air-conditioning dealer. To avoid compressor damage, do not operate the cooling system when outdoor temperature is below 50°F (10°C). Turn off power to the system at the furnace or the fuse/circuit breaker panel. Carefully unpack your new thermostat and wallplate. Save package of screws, instructions, and receipt. Remove the cover from the old thermostat. If the cover does not snap off when pulled firmly from the bottom, check for a screw or screws used to lock on the cover. Loosen the screw or screws holding the thermostat to the wallplate and lift the thermostat away. Disconnect the wires from the old thermostat. As you disconnect each wire, attach the enclosed labels with the old terminal designation. If there are only two wires, they do not need to be labeled. Wrap the wires around a pencil as shown to keep them from falling back into the wall. Special Installations Read this section if you are replacing: · Clock thermostat with separate wires for the clock. · Thermostat with six or more wires connected to it. · Thermostat in a heating only system with three wires. WIRES THROUGH WALL OPENING Replacing a Clock Thermostat that has C or C1 Clock Terminals M5136 If you are replacing a Honeywell Chronotherm® Thermostat, you may find one or two wires going to the C or C1 clock terminals on the Chronotherm wiring wallplate. Do not allow them to touch, or you can damage the transformer. Disconnect the wires and wrap them separately using electrical tape. Do not wrap them together. Place the wires where they will not interfere with the operation of the new thermostat. Record the colors and terminal designation labels of the remaining wires. Replacing a Thermostat that has Six or More Wires If there are six or more wires (excluding clock wires attached to terminals), you probably have a variation of a multistage heat pump or other multistage system. This thermostat is not compatible with multistage systems, so return the product to the place of purchase. For information about which programmable thermostats will work with your system, call Honeywell Customer Relations Center, at 1-800-468-1502. Replacing a Thermostat that has Three Wires If you have three wires for a heating only system and can operate the fan using the fan ON switch this thermostat works with your system. However, some hot water (zoned) heating systems also have three wires. Your thermostat will work only if you install an isolating relay on these systems. For details, call your local heating and/or cooling contractor. 69-1642 6 STEP 3. MOUNT THERMOSTAT WALLPLATE Separate the wallplate from the thermostat by placing your thumb or fingers between the bottom of the wallplate and the thermostat, and pulling the wallplate up and away from the thermostat. See illustration at right. Position the wallplate on the wall. Level the wallplate for appearance if desired. Use a pencil to mark the two mounting holes that best fit the application. Remove the wallplate from the wall. Drill two 3/16 in. holes in wall (if drywall) as shown. For materials such as plaster or wood, drill 7/32 in. holes where marked. Gently, tap the (provided) anchors into the drilled holes until they are flush with the wall. Reposition the wallplate over the holes. Pull the wires through the wiring opening. Loosely insert mounting screws into each of the holes. Level the wallplate if desired. Thermostat functions properly when not level. Tighten mounting screws. WALL WIRES THROUGH WALL M16427 WALL ANCHORS (2) MOUNTING HOLES MOUNTING SCREWS M15044 7 69-1642 STEP 4. WIRE WALLPLATE TERMINALS IMPORTANT All wiring must comply with local codes and ordinances. If unsure about household wiring procedures, call your local heating/air-conditioning contractor. Refer to the labels you placed on the wires when you removed the old thermostat (see illustration). Match the letter of your old thermostat wire with the corresponding terminal letter on your new thermostat. Refer to Table 2. Remove the factory-installed jumper connecting terminals R and RC if wires are connected to both of those terminals. For wiring diagrams, if needed, see pp 22-23. Loosen the terminal screws. Slip each wire beneath its matching terminal. Wraparound and straight connections are both acceptable, (see illustration). Tighten the terminals. FOR WRAPAROUND INSERTION STRIP 7/16 IN. (11 MM). FOR STRAIGHT INSERTION STRIP 5/16 IN. (8 MM). M16425 R W Y G M4826 Plug the hole in the wall with insulation to help prevent drafts from adversely affecting thermostat operation. 69-1642 8 Table 2. Terminal Designations on Old and New Thermostats Terminal on Old Thermostat R, RHa, 4, V R Rc W Y G O Bb c b Connect To Power Power for cooling Heat Cooling Fan Description Rc, Ra W, W1, H Y, Y1, M G, F O Bb C,X,B W2, H2 Y2 a b c c Changeover in cool. (Single stage heat pump only). Changeover in heat. (Single stage heat pump only). Transformer common Second stage heat. Second stage cool. Do not connect. Do not continue installation. Call 1-800-468-1502. If both RH and R terminals are present on existing thermostat, remove jumper and connect Rh to R and R to Rc. Do not connect both O and B when wiring to a single stage heat pump. Connect O to O. Tape off B. Tape off end of the wire with electrical tape and push the taped wire back into the w ...

  Know our Partners   Frequently Asked Questions   Contact Diplodocs team   Last searches
Latest additions
  Sitemap
Brands starting with A B C D E F G H I J K L M N O P Q R S T U V W X Y Z #
Copyright © 2005 - 2008 - Diplodocs - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.