User guide HONEYWELL RTH7000
Detailed instructions for use are in the User's Guide. Operating Manual
RTH7000 Series
Programmable Thermostat
This manual covers RTH7400 and RTH7500 models.
(Pull thermostat from wallplate and turn over to find model number)
CAUTION: EQUIPMENT DAMAGE HAZARD. To prevent possible compressor damage, do not operate cooling system when outdoor temperature is below 50°F (10°C).
Need Help?
For assistance with this product please visit http://yourhome.honeywell.com or call Honeywell Customer Care toll-free at 1-800-468-1502
Read and save these instructions
® U.S. Registered Trademark. Patents pending. Copyright © 2006 Honeywell International Inc. All rights reserved.
RTH7400/RTH7500
Table of contents
About your new thermostat
Thermostat features ..........................2 Programming at a glance..................3 Quick reference to controls ..............4 Quick reference to status display ....5
Appendices
Battery replacement ........................17 In case of difficulty ..........................18 Limited warranty ..............................20
Programming & Operation
Clock setting ......................................6 Fan setting ........................................7 System setting....................................8 Using program schedules ................9 Program schedule overrides ..........13 Furnace filter reminder ....................15 Special features ..............................16 This thermostat is ready to go! Your new thermostat is preprogrammed and ready to go. See page 3 to check settings.
1
Operating Manual
About your new thermostat
Congratulations! You've just purchased the world's most advanced, easy-to-use thermostat. It has been designed to give you many years of reliable service and touchscreen climate control.
Features
· · · · · · Daily program schedules maximize comfort and economy. EnergyStar® compliant to greatly reduce your heating/cooling expenses. One-touch temp control overrides program schedule at any time. Precise comfort control keeps temperature within 1°F of the level you set. Change/check reminder lets you know when to replace furnace filter. Large screen display with backlight is easy to read -- even in the dark.
2
RTH7400/RTH7500
This thermostat is ready to go!
Your new thermostat is pre-programmed and ready to go. All you have to do is set the time and day. Then check the settings below and change if needed: 1 2 3 4 Set clock ..................................................................................................See page 6 Select fan setting: Preset to Auto ......................................To change, see page 7 Select system setting: Preset to Heat................................To change, see page 8 Program schedules: Preset to energy-saving levels while you're at work or asleep (assumes you wake at 6 am, leave at 8 am, return at 6 pm and go to bed at 10 pm)................................................To change, see pages 10-14
ONE-TOUCH TEMP CONTROL: You can override the program schedule at any time, and manually adjust the temperature (see pages 13-14).
3
Operating Manual
Quick reference to controls
Arrow buttons Press to adjust temperature (see pages 11-14), or to make selections from screen menus.
System & Fan Press to select fan operation (see page 7) or system (see page 8).
Clock & More Press to set clock (see page 6) or furnace filter reminder.
Schedule Press to set program schedule (see pages 11-12). 4
RTH7400/RTH7500
Quick reference to status display
Current day of week Current inside temperature
Mon
Current time
Smart Response Technology in effect (see page 15)
®
70
Recovery System Cool System & Fan
Temperature setting
Set To
6:01
Fan Auto Schedule
AM
70
Heat On
Clock & More
System setting (see page 8)
Fan setting (see page 7)
Other display messages: · Cool On: Cooling system is activated · Heat On: Heating system is activated · Aux Heat On: Auxiliary heating system is activated (heat pump systems only) 5
Operating Manual
Clock setting
Press
CLOCK
System & Fan
Schedule
Clock & More
To set the current time display, press CLOCK, then press or to adjust the time. Press and hold or to advance the time more quickly. Press DONE to save & exit (or press GO BACK to exit without changing the time).
Note: The real-time clock should never require adjustment since it automatically updates for daylight savings time, and stores all date/time information.
Adjust time, then press
Mon
DONE
6:01
Go Back
AM
Done
Note: To change the current week day display, see System Setup in your Installation Guide. 6
RTH7400/RTH7500
Fan setting
Press
SYSTEM
&
FAN
Press SYSTEM & FAN, then FAN to select fan operation:
Clock & More
System & Fan
Schedule
· ·
On: Fan is always on. Auto: Fan runs only when the heating or cooling system is on.
Press
FAN
to select mode, then press
DONE
System Heat System
Fan Auto
Fan
Done
7
Operating Manual
System setting
Press
SYSTEM
&
FAN
Follow steps at left to select system:
Clock & More
System & Fan
Schedule
· ·
Press SYSTEM to select mode, then press DONE
· · ·
System Heat System
Fan Auto
Fan
Done
Heat: Thermostat controls only the heating system. Cool: Thermostat controls only the cooling system. Auto: Thermostat automatically selects heating or cooling depending on the indoor temperature. Off: All systems are off. Em Heat (only for heat pumps with auxiliary heat): Thermostat controls Emergency and Auxiliary Heat. Compressor is locked out.
Note: The Auto and Em Heat system settings may not appear, depending on how your thermostat was installed. 8
RTH7400/RTH7500
Save money by setting program schedules
It's easy to program your system for maximum energy savings. You can program four time periods each day, with different settings for weekdays and weekends. WAKE
6:00 am
Set to the time you awaken and the temperature you want during the morning, until you leave for the day. Set to the time you leave home and the temperature you want while you are away (usually an energy-saving level).
70 °
LEAVE
8:00 am
62 °
RETURN Set to the time you return home and the temperature you want during the evening, until bedtime. 6:00 pm
70 °
SLEEP
10:00 pm
Set to the time you go to bed and the temperature you want overnight (usually an energy-saving level).
9
62 °
Operating Manual
EnergyStar® settings for maximum cost savings
This thermostat is pre-set to use EnergyStar® program settings. We recommend these settings, since they can reduce your heating/cooling expenses by as much as 33%. (See next page to adjust times and temperatures of each time period.) Heat (Mon-Fri) Wake
(6:00 am)
Cool (Mon-Fri)
Heat (Sat-Sun)
Cool (Sat-Sun)
Leave
(8:00 am)
Return
(6:00 pm)
Sleep
(10:00 pm)
70 ° 62 ° 70 ° 62 °
78 ° 85 ° 78 ° 82°
10
70 ° 62 ° 70 ° 62 °
78 ° 85 ° 78 ° 82°
RTH7400/RTH7500
To adjust program schedules (RTH7400 only)
Press
SCHEDULE Schedule Clock & More
1
Press SCHEDULE, then EDIT to see weekdays.
System & Fan
2 Press SELECT DAY to highlight Mon-Fri (they will share the same settings).
3 4 Press NEXT STEP twice, then press or to set Wake time for selected days. Press NEXT STEP, then or to set Heat temperature for this time period. Press NEXT STEP, then or to set Cool temperature for this time period. Repeat steps 3-5 to program other time L periods (LEAVE, RETURN, SLEEP), then press DONE. Repeat steps 1-6 to program Saturday/ Sunday. (Press or until the desired day is flashing, then press SELECT DAY.) Press DONE to save & exit.
11
Press
EDIT Edit View
Go Back
5 6
MON TUE WED THU FRI
Period Wake
Set To
AM
6:00
Next Step
62
Heat Done
7 8
Go Back
Select day(s)
Select time Select temp
Operating Manual
To adjust program schedules (RTH7500 only)
Press
SCHEDULE Schedule Clock & More
1
Press SCHEDULE, then EDIT to see weekdays.
System & Fan
2 Press SELECT DAY. You can select multiple days to program with the same settings.
3 4 Press NEXT STEP twice, then press or to set Wake time for selected day(s). Press NEXT STEP, then or to set Heat temperature for this time period. Press NEXT STEP, then or to set Cool temperature for this time period. Repeat steps 3-5 to program other time L periods (LEAVE, RETURN, SLEEP), then press DONE. Repeat steps 1-6 to program Saturday/ Sunday. (Press or until the desired day is flashing, then press SELECT DAY.) Press DONE to save & exit.
12
Press
EDIT Edit View
Go Back
5 6
MON TUE WED THU FRI
Period Wake
Set To
AM
6:00
Next Step
62
Heat Done
7 8
Go Back
Select day(s)
Select time Select temp
RTH7400/RTH7500
Program schedule override (temporary)
Adjust temperature
Mon Temporary Set To
62
System Heat System & Fan
6:08
Fan Auto Use Schedule
AM
68
Heat On
Press or to immediately adjust the temperature. This will temporarily override the temperature setting for the current time period. The new temperature will be maintained until the next time period. When the timer expires, the program schedule will resume and set the temperature to the level you've programmed for the current time period. To cancel the temporary setting at any time, press USE SCHEDULE.
Clock & More
Press USE SCHEDULE to resume program schedule
13
Operating Manual
Program schedule override (permanent)
1- Adjust temperature
Mon
62
System Heat
Set To
Press or to adjust temperature, then press HOLD. This will turn off the program schedule. Whatever temperature you set will be maintained 24 hours a day, until you manually change it, or press USE SCHEDULE to cancel "Hold" and resume the program schedule.
6:08
Fan Auto Hold
AM
68
Cancel
Permanent Hold
2- Press HOLD to turn off program schedule and maintain set temperature
14
RTH7400/RTH7500
Furnace filter reminder
Press RESET after changing filter
Change Filter
If activated during installation, the furnace filter reminder alerts you when it is time to replace your filter. Press RESET after changing the filter, to restart the timer. To reset the reminder interval before it expires: 1 Press MORE, then NEXT. Press RESET. Press DONE to save and exit.
70
System Heat Reset
Set To
6:01
Fan Auto Schedule
AM
70
Heat On
Clock & More
2 3
Press MORE to reset reminder interval
60
Days Reset Next Done
15
Operating Manual
Special features
Smart Response® Technology: This feature allows the thermostat to "learn" how long the furnace and air conditioner take to reach programmed temperature settings, so the temperature is reached at the time you set. For example: Set the Wake time to 6 am, and the temperature to 70°. The heat will come on before 6 am, so the temperature is 70° by the time you wake at 6. The message "Recovery" is displayed when the system is activated before a scheduled time period. Compressor Protection: This feature forces the compressor to wait a few minutes before restarting, to prevent equipment damage. During the wait time, the message "Wait" is displayed on screen. Auto Changeover (RTH7500 only): This feature is used in climates where both air conditioning and heating are used on the same day. When the system is set to Auto, the thermostat automatically selects heating or cooling depending on the indoor temperature. Heat and cool settings must be at least 3 degrees apart. The thermostat will automatically adjust settings to maintain this 3-degree separation.
CAUTION: To avoid possible compressor damage, do not use Auto Changeover if the outside temperature drops below 50°F (10°C). 16
RTH7400/RTH7500
Battery replacement
Grasp thermostat and pull to remove from wallplate
Batteries are optional (to provide backup power) if your thermostat was wired to run on AC power when installed. Install fresh batteries immediately when the LO BATT warning begins flashing. The warning flashes about 30 days before batteries are depleted. Even if the warning does not appear, you should replace batteries once a year, or before leaving home for more than a month.
Insert 2 fresh AA alkaline batteries
17
Operating Manual
In case of difficulty
If you have difficulty with your thermostat, please try the suggestions below. Most problems can be corrected quickly and easily.
Display is blank · · · · Check circuit breaker and reset if necessary. Make sure power switch at heating & cooling system is on. Make sure furnace door is closed securely. If thermostat is battery powered, make sure fresh AA alkaline batteries are correctly installed (see page 17).
No response to key presses (or temperature will not change)
Make sure heating and cooling temperatures are set to acceptable ranges: · Heat: 40° to 90°F (4.5° to 32°C). · Cool: 50° to 99°F (10° to 37°C).
18
RTH7400/RTH7500
In case of difficulty
Heating or · Press SYSTEM to set system to Heat. Make sure the temperature is set cooling system higher than the Inside temperature. does not respond · Press SYSTEM to set system to Cool. Make sure the temperature is set lower than the Inside temperature. · · · · Check circuit breaker and reset if necessary. Make sure power switch at heating & cooling system is on. Make sure furnace door is closed securely. If "Wait" is displayed, the compressor protection timer is on. Wait 5 minutes for the system to restart safely, without damaging the compressor (see page 15).
19
Operating Manual
1-year limited warranty
Honeywell warrants this product, excluding battery, to be free from defects in the workmanship or materials, under normal use and service, for a period of one (1) year from the date of purchase by the consumer. If at any time during the warranty period the product is determined to be defective or malfunctions, Honeywell shall repair or replace it (at Honeywell's option). If the product is defective, (i) return it, with a bill of sale or other dated proof of purchase, to the place from which you purchased it; or (ii) call Honeywell Customer Care at 1-800-468-1502. Customer Care will make the determination whether the product should be returned to the following address: Honeywell Return Goods, Dock 4 MN10-3860, 1885 Douglas Dr. N., Golden Valley, MN 55422, or whether a replacement product can be sent to you. This warranty does not cover removal or reinstallation costs. This warranty shall not apply if it is shown by Honeywell that the defect or malfunction was caused by damage which occurred while the product was in the possession of a consumer. 20
RTH7400/RTH7500
1-year limited warranty
Honeywell's sole responsibility shall be to repair or replace the product within the terms stated above. HONEYWELL SHALL NOT BE LIABLE FOR ANY LOSS OR DAMAGE OF ANY KIND, INCLUDING ANY INCIDENTAL OR CONSEQUENTIAL DAMAGES RESULTING, DIRECTLY OR INDIRECTLY, FROM ANY BREACH OF ANY WARRANTY, EXPRESS OR IMPLIED, OR ANY OTHER FAILURE OF THIS PRODUCT. Some states do not allow the exclusion or limitation of incidental or consequential damages, so this limitation may not apply to you. THIS WARRANTY IS THE ONLY EXPRESS WARRANTY HONEYWELL MAKES ON THIS PRODUCT. THE DURATION OF ANY IMPLIED WARRANTIES, INCLUDING THE WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE, IS HEREBY LIMITED TO THE ONE-YEAR DURATION OF THIS WARRANTY. Some states do not allow limitations on how long an implied warranty lasts, so the above limitation may not apply to you. This warranty gives you specific legal rights, and you may have other rights which vary from state to state. If you have any questions concerning this warranty, please write Honeywell Customer Relations, 1985 Douglas Dr, Golden Valley, MN 55422 or call 1-800-468-1502. In Canada, write Retail Products ON15-02H, Honeywell Limited/Honeywell Limitée, 35 Dynamic Drive, Scarborough, Ontario M1V4Z9. 21
Automation and Control Solutions
Honeywell International Inc. 1985 Douglas Drive North Golden Valley, MN 55422 http://yourhome.honeywell.com
Printed in U.S.A. on recycled paper containing at least 10% post-consumer paper fibers. ® U.S. Registered Trademark. © 2006 Honeywell International Inc. Patents pending. All rights reserved. 69-1899EF · 01-2006
Honeywell Limited-Honeywell Limitée 35 Dynamic Drive Scarborough, Ontario M1V 4Z9
Mode d'emploi
RTH7000 Series
Thermostat programmable
Ce guide a trait aux modèles suivants: RTH7400 et RTH7500.
(Il suffit de tirer le thermostat de la plaque murale et de le retourner pour voir la référence du modèle)
ATTENTION : RISQUE D'ENDOMMAGER L'ÉQUIPEMENT. Pour éviter tout risque de dommage au compresseur, ne pas faire fonctionner la climatisation lorsque la température extérieure est inférieure à 50° F (10° C)
Vous faut-il de l'aide ?
Pour obtenir de l'assistance concernant ce produit, visitez www.honeywell.com/yourhome ou appelez gratuitement l'assistance client d'Honeywell au 1-800-468-1502.
Veuillez lire et conserver ces instructions
® U.S. Marque déposée. Brevets en instance. Copyright © 2006 Honeywell International Inc. Tous droits réservés.
RTH7400/RTH7500
Table des matières
À propos de votre nouveau thermostat Caractéristiques du thermostat ........2 La programmation en bref ................3 Aide-mémoire sur les commandes ..4 Aide-mémoire sur l'affichage ............5 Programmation et fonctionnement Réglage de l'horloge ........................6 Fonctionnement de la ventilation ....7 Mode de fonctionnement ..................8 Utilisation de la programmation........9 Annulation de la programmation ....13 Rappel de changement du filtre de la chaudière........................15 Fonctions spéciales ........................16 Annexes Pose des piles ................................17 En cas de difficultés ........................18 Garantie limitée................................20
Ce thermostat est prêt à fonctionner Votre nouveau thermostat est préprogrammé et prêt à fonctionner. La configuration se trouve à la page 3.
1
Mode d'emploi
À propos de votre nouveau thermostat
Félicitations! Vous venez d'acheter le thermostat le plus perfectionné et le plus facile à utiliser du monde.
Caractéristiques
· · · · · · Programmes quotidiens maximisant confort et économie. Conforme aux exigences du programme EnergyStar®, ce qui réduit considérablement les dépenses de chauffage/climatisation. Annulation du programme à tout moment par commande de climat à un seul bouton. Commande précise du climat maintenant la température à 1° F du niveau fixé. Rappels changer/vérifier permettant de savoir à quel moment réviser ou remplacer les filtre de four. Grand affichage facile à lire, même dans le noir.
2
RTH7400/RTH7500
Ce thermostat est prêt à fonctionner
Votre nouveau thermostat est pré-programmé et prêt à fonctionner. Il suffit de régler l'heure et le jour. Vérifiez ensuite les réglages ci-dessous et modifiez-les si besoin est : 1 2 3 4 Réglage de l'horloge ..............................................................................Voir page 6 Sélection de la configuration du ventilateur : Pré-réglé sur Auto....Voir page 7 Sélection du mode de fonctionnement : Préréglé sur Chauffage ....Voir page 8 Programme de régulation : pré-réglages aux niveaux économie d'énergie pendant vos heures de travail ou de sommeil (présumez que vous vous levez à 6 h, partez à 8 h, rentrez à 18 h et vous couchez à 22 h) ..........................................................................Voir les pages 10-14
COMMANDE DE TEMPÉRATURE PAR TOUCHE UNIQUE : Vous pouvez annuler le programme à n'importe quel moment et régler manuellement la température (voir pages 13-14) 3
Mode d'emploi
Aide-mémoire des commandes
Appuyez pour modifier la température (voir pages 11-14), ou pour faire des choix à partir des menus System & Fan Appuyez pour sélectionner la configuration du ventilateur (voir page 7) ou système (voir page 8).
Clock & More Appuyez pour régler l'horloge (voir page 6) ou rappel de changement du filtre de la chaudière
Schedule Appuyez pour paramétrer le programme (voir pages 11-12) 4
RTH7400/RTH7500
Aide-mémoire de l'affichage d'état
Jour actuel de la semaine Smart Response Technology (voir page 15)
®
Température intérieure actuelle
Mon
Heure actuelle
70
Recovery System Cool System & Fan
Set To
6:01
Fan Auto Schedule
AM
70
Heat On
Réglage de la température
Clock & More
Réglage système (voir page 8)
Réglage ventilation (voir page 7)
Autres messages affichés : · Cool On : Le système de climatisation est activé · Heat On : Le système de chauffage est activé · Aux Heat On: Le système de chauffage auxiliaire est activé (thermopompe seulement)
5
Mode d'emploi
Réglage de l'horloge
Appuyez sur
System & Fan CLOCK
Schedule
Clock & More
Modifiez l'heure et appuyez sur
Mon
Pour régler l'affichage de l'heure actuelle, appuyez sur CLOCK, puis sur ou pour modifier l'heure. Appuyez sur ou maintenant la pression pour avancer l'heure plus rapidement. Appuyez sur DONE pour sauvegarder et quitter (ou appuyez sur GO BACK pour quitter sans modifier l'heure).
DONE
6:01
Go Back
AM
Done
Note : l'horloge temps réel ne devrait jamais nécessiter de réglage puisqu'elle est automatiquement mise à jour lors des changements entre heure d'été et heure d'hiver et met en mémoire tous les renseignements concernant la date et l'heure. 6
RTH7400/RTH7500
Réglage du fonctionnement de la ventilation
Appuyez
SYSTEM
&
FAN
System & Fan
Schedule
Clock & More
Appuyez sur SYSTEM & FAN, puis sur FAN pour sélectionner le fonctionnement de la ventilation : · On : Le ventilateur est constamment en marche. Auto : Le ventilateur ne fonctionne que lorsque la chauffage ou la climatisation fonctionne.
Appuyez
FAN
au mode choisi, puis
DONE
·
System Heat System
Fan Auto
Fan
Done
7
Mode d'emploi
Sélection du mode de fonctionnement
Appuyez
SYSTEM
&
FAN
Suivez les étapes à la gauche pour choisir le système :
Clock & More
System & Fan
Schedule
· ·
Appuyez
SYSTEM
au mode choisi, puis
DONE
·
System Heat System Fan Auto
·
Done
Fan
·
Note : Les options Auto et Em Heat peuvent ne pas apparaître, selon la façon dont votre thermostat a été installé.
Heat : Le thermostat ne commande que l'installation de chauffage. Cool : Le thermostat ne commande que l'installation de climatisation. Off : Arrêt des installations de chauffage et de climatisation. Auto : Le thermostat sélectionne automatiquement le chauffage ou la climatisation en fonction de la température intérieure. Em Heat : (uniquement pour les thermopompes à chauffage auxiliaire) : Le thermostat commande le chauffage d'urgence et auxiliaire. Le compresseur est verrouillé.
8
RTH7400/RTH7500
Économisez de l'argent en paramétrant le programme
Il est facile de programmer votre système afin de réaliser un maximum d'économies d'énergie. Vous pouvez programmer quatre plages horaires chaque jour, avec des réglages différents la semaine et les week-ends. Programmez l'heure de votre réveil et la température désirée le matin WAKE
6:00 am
70 °
LEAVE
8:00 am
jusqu'à votre départ pour la journée. Programmez l'heure de votre départ et la température désirée pendant votre absence (en général, un niveau d'économie d'énergie). Programmez l'heure de votre départ et la température désirée pendant votre absence (habituellement, un niveau d'économie d'énergie).
62 °
6:00 pm
RETURN Programmez l'heure de votre retour et la température désirée pendant la
soirée, jusqu'à l'heure du coucher.
70 °
SLEEP
10:00 pm Programmez l'heure de votre coucher et la température désirée pendant la nuit (habituellement, un niveau d'économie d'énergie). 9
62 °
Mode d'emploi
Réglages EnergyStar® pour économiser au maximum
Ce thermostat est préréglé pour utiliser les paramètres du programme Energy Star®. Nous conseillons ces réglages car ils peuvent réduire vos dépenses de chauffage/ climatisation de jusqu'à 33%. (Voir la page suivante pour horaires et températures de chaque plage.) Heat (Lun-Ven) Wake
(6:00 am)
Cool (Lun-Ven) Heat (Sam-Dim) Cool (Sam-Dim)
Leave
(8:00 am)
Return
(6:00 pm)
Sleep
(10:00 pm)
70 ° 62 ° 70 ° 62 °
75 ° 83 ° 75 ° 78 °
10
70 ° 62 ° 70 ° 62 °
75 ° 83 ° 75 ° 78 °
RTH7400/RTH7500
Pour modifier le programme (RTH7400 seulement)
Appuyez sur
System & Fan SCHEDULE Schedule Clock & More
1 2 3
Appuyez sur
Go Back
EDIT Edit View
4 5 6
MON TUE WED THU FRI
Period Wake
Set To
AM
6:00
Next Step
62
Heat Done
7 8
Go Back
Appuyez sur SCHEDULE, puis EDIT. Appuyez SELECT DAY pour accentuer Lun-Ven (ils partageront les mêmes arrangements). Appuyez NEXT STEP deux fois, serrez alors pour placer le temps de Wake. Appuyez NEXT STEP, puis pour placer la température de la Heat pour cette période. Appuyez NEXT STEP, puis pour placer la température de la Cool pour cette période. Répétez les étapes 3-5 pour programmer L d'autres périodes (LEAVE, RETURN, SLEEP), puis appuyez DONE. Répétez les étapes 1-6 pour programmer Sam-Dim. (appuyez jusqu'à ce que le jour désiré clignote, puis appuyez SELECT DAY.) Appuyez DONE pour sauvegarder et quitter.
Les jours
Le temps
La température 11
Mode d'emploi
Pour modifier le programme (RTH7500 seulement)
Appuyez sur
System & Fan SCHEDULE Schedule Clock & More
1 2 3
Appuyez sur
Go Back
EDIT
4
Edit View
5
MON TUE WED THU FRI
6
Period Wake Set To
AM
6:00
Next Step
62
Heat
7 8
Go Back
Done
Appuyez sur SCHEDULE, puis EDIT. Appuyez SELECT DAY. Vous pouvez choisir des jours multiples pour programmer avec les mêmes arrangements. Appuyez NEXT STEP deux fois, serrez alors pour placer le temps de Wake. Appuyez NEXT STEP, puis pour placer la température de la Heat pour cette période. Appuyez NEXT STEP, puis pour placer la température de la Cool pour cette période. Répétez les étapes 3-5 pour programmer L d'autres périodes (LEAVE, RETURN, SLEEP), puis appuyez DONE. Répétez les étapes 1-6 pour programmer Sam-Dim. (appuyez jusqu'à ce que le jour désiré clignote, puis appuyez SELECT DAY.) Appuyez DONE pour sauvegarder et quitter.
12
Les jours
Le temps
La température
RTH7400/RTH7500
Annulation de la programmation (momentanée)
If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Diplodocs provides you a fast and easy access to the user manual HONEYWELL RTH7000. HONEYWELL offer a product for which we do not have the user manual? Let us know what you are looking for: site Internet, histoire, actualité, filiales, site Internet, mode d'emploi, driver, avis des utilisateurs, meilleur prix des produits, forum d'assistance aux problèmes, annuaire des marques, annuaire des constructeurs, répertoire des marques, répertoire des constructeurs, site Internet de la marque, site Internet du constructeur Diplodocs allows you to download user manual HONEYWELL RTH7000, user guide HONEYWELL RTH7000, instructions HONEYWELL RTH7000, owner's manual HONEYWELL RTH7000, online manual HONEYWELL RTH7000.Access web reviews HONEYWELL RTH7000, , |
![]() |
Include the add-on to download manuals from your site, forum or blog | ![]() |
Frequently Asked Questions | ![]() |
Contact Diplodocs team | ![]() |
Last searches Last additions |
![]() |
Sitemap | ![]() |
|||
| Brands starting with A B C D E F G H I J K L M N O P Q R S T U V W X Y Z # | |||||||||||||
|
|
Copyright © 2005 - 2008 - Diplodocs -
All Rights Reserved. Designated trademarks and brands are the property of their respective owners. |