9 562 brands
2 694 000 user's guides


Download your manual, it's FREE! Diplodocs allows you to download several types of document in order to best use your HONEYWELL T8000C : user manual, user guide, instruction manual.
Search a brand
Advanced Search

Need help using a product?
Look at the reviews on HONEYWELL T8000C

User manual HONEYWELL T8000C

Diplodocs help download the user guide HONEYWELL T8000C .

Download the complete user guide (358 Ko)



This product, although classified under the brand HONEYWELL, may have been manufactured by ADEMCO, DOMONIAL, ENVIRACAIRE, FBII, FISHER PRICE, GALAXY, INTELLISENSE, RELI ON after mergers, acquisitions, or a change in name.



Preview of the first 3 pages of manual

You either have JavaScript turned off or an old version of Adobe Flash Player
Get the latest Flash Player.
Manual abstract: user guide HONEYWELL T8000C

Detailed instructions for use are in the User's Guide.

T8000C Programmable Thermostat OWNER'S GUIDE 69-1437EF Features · Program up to four time periods and temperature settings to complement your lifestyle. · Set different schedules for weekdays and weekends. · Programs are permanently held in non-volatile memory in the event of a power failure. · Indefinite temperature hold. · Preprogrammed for your convenience. 2 69-1437EF Welcome to the world of comfort and energy savings with your new Honeywell programmable thermostat. Your new Programmable Thermostat is designed to provide you with reliable, precise temperature control. When you follow the simple programming instructions in this manual, your thermostat automatically controls the temperature in your home, saving energy and allowing you to awake (or return home) to a comfortable level of heating or air conditioning. Direct questions concerning the operation of this thermostat to Honeywell Customer Assistance at 1-800-468-1502, Monday-Friday, 7:00 a.m.-5:30 p.m., Central time. 3 69-1437EF The thermostat display shows day, time, program period, and temperature. Table 1. Preprogrammed Time and Temperature Settings. Period Wake Leave Return Sleep Time 6:00 AM 8:00 AM 6:00 PM 10:00PM Heat Setpoint 21°C (70°F ) 17°C (62°F ) 21°C (70°F ) 17°C (62°F ) Cool Setpoint 26°C (78°F ) 29°C (85°F ) 26°C (78°F ) 28°C (82°F ) The thermostat can be set for four time periods per day for weekdays and weekends. Before programming the thermostat, you can use the following chart on page 5, to organize your program schedule. Fill in the times and temperatures you desire for weekdays and weekends. If you decide not to program the thermostat, it will follow the preprogrammed time and temperature settings shown in Table 1. 4 69-1437EF Program Schedule Weekday Wake Leave Return Sleep Weekend Wake Leave Return Sleep Start Time ________ ________ ________ ________ Start Time ________ ________ ________ ________ Heating Temperature ________ ________ ________ ________ Heating Temperature ________ ________ ________ ________ Cooling Temperature ________ ________ ________ ________ Cooling Temperature ________ ________ ________ ________ WAKE and RETURN start times should include extra lead time, based on outside temperature and equipment response time, to give your equipment a head start to heat or cool the house. The temperatures cannot be set any higher than 37°C (99°F) or any lower than 4°C (40°F). 5 69-1437EF Programming The thermostat is flexible and can be programmed for different schedules for weekdays and weekends, to meet your lifestyle needs. Use the personal Program Schedule for planning your time and temperature settings for various times of the day. See page 5. Four time periods are available during weekdays and weekends --WAKE, LEAVE, RETURN, and SLEEP. WAKE is the time the thermostat turns on the heating/cooling equipment after an energy saving period. When deciding what time to set for your WAKE period, include extra lead time, depending on the outside temperature and your equipment response time, to give the equipment a head start to 6 heat or cool the house before you get up. (This will be a higher temperature during heating season, and a lower temperature during cooling season.) LEAVE is the time period you can set for an energy-saving temperature while you are away at work or school. (This will be a lower temperature during heating season, and a higher temperature during cooling season.) RETURN is the time the thermostat turns on the heating/cooling equipment after an energy saving period. When deciding what time to set for your RETURN period, include extra lead time, depending on the outside temperature and your equipment response time, to give the equipment a head start to heat or cool the house before you arrive home. 69-1437EF SLEEP is the time period you can set for an energy-saving temperature while you are sleeping. (For more comfortable sleeping, some people choose not to raise the cool temperature during the night.) While setting the current time, the word SET is flashing. 2. To Set Day of Week. Press Select again. Press v or w to set current day. MON M12593A IMPORTANT Always press the keys with your fingertip or similar blunt tool. Sharp instruments like pens and pencil points can damage the keys. Setting the Current Time and Day 1. To Set Current Time Press Select twice. Press v or w SET to set current PM time. M12591A To use the preprogrammed time and temperature settings (see Table 1), press Hold now, to exit the programming mode. To enter a custom program to fit you life style, continue to step 3. 7 69-1437EF Setting the Weekday Program Slide the SYSTEM switch to the position, heat or cool, you want to program. A flame (heating) or a snowflake (cooling) will appear in the lower right corner of the display, when setting the program temperature. 3. Wake a. Press Select. Press v or w to set Wake time. 4. Leave a. Press Select. Press v or w to set Leave time. M12626A b. Press Select. Press v or w to set Leave temperature. M14203A M12624A b. Press Select. Press v or w to set Wake temperature. M14205A 5. Return a. Press Select. Press v or w to set Return time. M12628A 8 69-1437EF b. Press Select. Press v or w to set Return temperature. M14204A Setting the Weekend Program 7. Wake a. Press Select. Press v or w to set Wake time. 6. Sleep a. Press Select. Press v or w to set Sleep time. M12632A b. M12630A Press Select. Press v or w to set Wake temperature. M14206A b. Press Select. Press v or w to set Sleep temperature. M14207A 9 69-1437EF 8. Leave a. Press Select. Press v or w to set Leave time. b. Press Select. Press v or w to set Return temperature. M14210A M12634A b. Press Select. Press v or w to set Leave temperature. M14211A 10. Sleep a. Press Select. Press v or w to set Sleep time. M12638A 9. Return a. Press Select. Press v or w to set Return time. b. Press Select. Press v or w to set Sleep temperature. SAT SUN M14212A M12636A 10 69-1437EF 11. Press Select. End is displayed. Programming is complete. The thermostat will revert to displaying the current day time and temperature in five M12511A seconds. Indefinite Temperature Hold The Hold key allows you to indefinitely hold a temperature. When Hold is active, the letters Hld are displayed continuously. Hold can be canceled by pressing the Hold key again. 1. Press Hold 2. Press v or w key to set indefinite temperature setting. Temporary Temperature Hold 1. Press v or w key to set a temporary temperature TEMPORARY setting. PM WED M14214A M14213A NOTE: The temporary temperature setting remains in effect until the next program period. To cancel press Hold twice. 11 69-1437EF Setting System and Fan Use the SYSTEM and FAN switches to change the settings. SYSTEM settings control the thermostat operation as follows: Heat: The thermostat controls the heating. Off: Both the heating and cooling are off. Cool: The thermostat controls the cooling. Slide the SYSTEM switch in the lower right corner of the thermostat to select the desired system setting. FAN settings control the system fan as follows: On: Fan operates continuously. Auto: Fan operates with equipment. Slide the FAN switch in the lower left corner of the thermostat to select the desired fan setting. Heat and Cool Indicators Indicates a call for heat. Indicates a call for cool. NOTE: In the programing mode the indicate system setting. and 12 69-1437EF Minimum Off-Timing A minimum off-timer in the T8000C assures that the compressor does not come on again for at least five minutes after it turns off. The minimum off-timer is triggered when the compressor turns off and when the SYSTEM switch position is changed. If the compressor turns off when the setpoint is changed, the minimum off-timer is triggered. Power interruption and power restoration also trigger the minimum off-timer. The minimum off-timer operates in cooling on the T8000C. A flashing snowflake indicates the minimum off time is in effect. 13 69-1437EF Troubleshooting Guide Symptom Display does not come on. · Action Check if the thermostat is mounted and latched on the wallplate--mount and latch the thermostat on the wallplate. Check if the circuit breaker is tripped--reset the circuit breaker. Check if the fuse is blown--replace the fuse. Check if the switch at the equipment is in the Off position--set to the On position. Check that the temperature setpoints are: between 4 to 37°C (40 to 99°F ). · · · Temperature settings do not · change (Example: cannot set the heating higher or the cooling lower). (continued) 14 69-1437EF Troubleshooting Guide (continued). Symptom Heating does not come on. Action · Check if the circuit breaker is tripped--reset the circuit breaker. · Check if the fuse is blown--replace the fuse. · Check if the switch at the equipment is in the Off position--set to On position. · Wait five minutes for the system to respond. · Set SYSTEM switch to Heat. · Check if the circuit breaker is tripped--reset the circuit breaker. · Check if the fuse is blown--replace the fuse. · Check if the switch at the equipment is in the Off position--set to On position. · Wait five minutes for the system to respond. · Set SYSTEM switch to Cool. (continued) 15 69-1437EF Cooling does not come on. Troubleshooting Guide (continued). Symptom System on indicator or is lit, but no warm or cool air is coming from the registers. System on indicator Minimum off timer is in effect. Wait five minutes until the minimum off timer is complete. See p[age 13 for minimum is flashing off-timing description. Action Wait a couple minutes after seeing the flame or snowflake and then check the registers. 16 69-1437EF Limited One-Year Warranty Honeywell warrants this product, excluding battery, to be free from defects in the workmanship or materials, under normal use and service, for a period of one (1) year from the date of purchase by the consumer. If, at any time during the warranty period, the product is defective or malfunctions, Honeywell shall repair or replace it (at Honeywell's option) within a reasonable period of time. If the product is defective, (i) return it, with a bill of sale or other dated proof of purchase, to the retailer from which you purchased it, or (ii) package it carefully, along with proof of purchase (including date of purchase) and a short description of the malfunction, and mail it, postage prepaid, to the following address: Honeywell Return Goods In Canada: Dock 4 MN10-3860 Honeywell Limited/Honeywell Limitée 1885 Douglas Drive North Product Services ON15-FFE Golden Valley, MN 55422 740 Ellesmere Road Scarborough, Ontario M1P 2V9 This warranty does not cover removal or reinstallation costs. This warranty shall not apply if it is shown by Honeywell that the defect or malfunction was caused by damage which occurred while the product was in the possession of a consumer. 17 69-1437EF Honeywell's sole responsibility shall be to repair or replace the product within the terms stated above. HONEYWELL SHALL NOT BE LIABLE FOR ANY LOSS OR DAMAGE OF ANY KIND, INCLUDING ANY INCIDENTAL OR CONSEQUENTIAL DAMAGES RESULTING, DIRECTLY OR INDIRECTLY, FROM ANY BREACH OF ANY WARRANTY, EXPRESS OR IMPLIED, OR ANY OTHER FAILURE OF THIS PRODUCT. Some states do not allow the exclusion or limitation of incidental or consequential damages, so this limitation may not apply to you. THIS WARRANTY IS THE ONLY EXPRESS WARRANTY HONEYWELL MAKES ON THIS PRODUCT. THE DURATION OF ANY IMPLIED WARRANTIES, INCLUDING THE WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE, IS HEREBY LIMITED TO THE ONE YEAR DURATION OF THIS WARRANTY. Some states do not allow limitations on how long an implied warranty lasts, so the above limitation may not apply to you. This warranty gives you specific legal rights, and you may have other rights which vary from state to state. If you have any questions concerning this warranty, please write our Customer Assistance Center, Honeywell 1985 Douglas Drive North, Golden Valley, MN 55422 or call 1-800-468-1502, Monday-Friday, 7:00 a.m. to 5:30 p.m., Central time. In Canada, write Retail Products ON15-02H, Honeywell Limited/Honeywell Limitée, 35 Dynamic Drive, Scarborough, Ontario M1V 4Z9. 18 69-1437EF 19 69-1437EF Home and Building Control Honeywell 1985 Douglas Drive North Golden Valley, MN 55422 Home and Building Control Honeywell Limited-Honeywell Limitée 35 Dynamic Drive Scarborough, Ontario M1V 4Z9 Copyright © 2000 Honeywell All Rights Reserved ® U.S. Registered Trademark 69-1437EF 9-00 G.H. Printed in Mexico www.honeywell.com T8000C Thermostat programmable GUIDE DU PROPRIÉTAIRE 21 69-1437EF 69-1437EF Caractéristiques · Offre la capacité de programmer jusqu'à quatre périodes et points de consigne de température pour convenir à votre mode de vie. · Permet d'établir des horaires différents pour chacun des jours de la semaine et de la fin de ...

  Know our Partners   Frequently Asked Questions   Contact Diplodocs team   Last searches
Latest additions
  Sitemap
Brands starting with A B C D E F G H I J K L M N O P Q R S T U V W X Y Z #
Copyright © 2005 - 2008 - Diplodocs - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.