Manual abstract: user guide HONEYWELL T8611M
Detailed instructions for use are in the User's Guide. Microelectronic Programmable Thermostat Owner's Manual
1
J.H. · 5-94 · Form Number 69-0819 69-0819
Table of Contents
Programmed Recovery ............................................... 3 Programming Your Thermostat ................................. 6 Programming ............................................................ 6 Program Schedule ............................................... 7 Set the Current Day and Time ............................ 11 Heating Program ................................................. 11 Copying One Day's Program to Another Day .... 12 Cooling Program ................................................ 12 Setting System and Fan Switches .......................... 13 Fan Switch ......................................................... 13 System Switch .................................................... 13 Operating Your Thermostat ...................................... 14 Temporarily Changing the Program ........................ 14 Permanently Changing the Program ...................... 15 Manually Operating the Thermostat ....................... 15 Canceling Program Settings ................................... 15 Checking the Program Times and Temperatures ... 16 Checking the Current Temperature Settings .......... 16 Maintaining Your Thermostat .................................... 17 Removing the Thermostat ....................................... 17 Replacing the Thermostat ....................................... 18 Replacing the Batteries ........................................... 19 Power Outages ........................................................ 19 Glossary ...................................................................... 20 Troubleshooting Guide .............................................. 23 Index ............................................................................ 26 Limited One-Year Warranty .............. Inside Back Cover
2
69-0819
Programmed Recovery
PROGRAMMED RECOVERY-- BREAK-THROUGH TECHNOLOGY SENSES TEMPERATURE MORE LIKE YOU DO
s Your body perceives temperature from a variety of sources, not only from the air in the zone, but also from your surroundings--walls, windows and furnishings. s Human beings feel differences in temperature as slight as two degrees Fahrenheit. s Common household thermometers and standard thermostats sense only air temperature, which may or may not reflect how hot or cold the zone actually feels to a human being. s Your new thermostat reads the temperature of the wall as well as the air--and responds to temperature changes as little as one degree Fahrenheit--so zone temperature is more likely to feel right to you and your family. THE OPTIMUM COMFORT AND ENERGY SAVINGS SOLUTION s This thermostat is actually a small but powerful computer. When calculating the exact time to turn on your furnace or air conditioner, it considers: (1) air temperature, (2) temperature of the wall and (3) when you want the comfort temperature established.
M168
Your new thermostat is so smart, it's almost human.
3
69-0819
s During programmed recovery, the thermostat gradually increases the control temperature and turns the equipment on and off several times to save energy by avoiding overshooting the comfort temperature. You can see the current control temperature anytime during recovery by pressing the PRESENT SETTING key. s This smart control learns from experience. Each day it checks how closely it hit the target and adjusts the recovery start time accordingly. It typically takes four to eight days after installation for this thermostat to adjust to the weather, your life style,
home construction and heating/cooling system. The thermostat calculates the LEAVE/RETURN recovery separately from the SLEEP/WAKE recovery. IMPORTANT: With Programmed Recovery, program the times when you want your home comfortable. The thermostat will decide how early to begin the temperature changes. NOTE: Some models will show 32° F instead of the current temperature, indicating the thermostat is operating on backup batteries until the thermostat is mounted on the wallplate and the system is powered.
4
69-0819
System Operating in Comfort Mode
AM PM
SET PT
SUN MON TUE WED THU FRI SAT COOL ON HEAT ON WAKE LEAVE RETURN SLEEP TEMPORARY UNOCCUIPIED
TEMPERATURE
AM PM
SET PT
SUN MON TUE WED THU FRI SAT COOL ON HEAT ON WAKE LEAVE RETURN SLEEP TEMPORARY UNOCCUIPIED
Recovery Begins
AM PM
SET PT
Recovery Continues
System Operating in Energy Savings Mode
AM PM
SET PT
SUN MON TUE WED THU FRI SAT COOL ON HEAT ON WAKE LEAVE RETURN SLEEP TEMPORARY UNOCCUIPIED
SUN MON TUE WED THU FRI SAT COOL ON HEAT ON WAKE LEAVE RETURN SLEEP TEMPORARY UNOCCUIPIED
ENERGY SAVINGS PERIOD
RECOVERY FROM ENERGY SAVINGS
COMFORT PERIOD
TIME
M171
THE THERMOSTAT USES THE SAME SCHEME TO RETURN GRADUALLY TO LOWER COMFORT TEMPERATURE DURING THE COOLING SEASON.
5
69-0819
Programming Your Thermostat
The thermostat can be programmed in your hand before it is installed or after it is on the wall if you make sure the batteries are installed. If you need to install or replace the batteries, refer to the Maintaining Your Thermostat section. Your thermostat can be programmed for seven days (separate programs for each day of the week). PROGRAMMING The personal programming chart can be helpful for plannng your program schedule of time and temperature settings for various times of the day. Four time periods are available: MORNING is the time period when you want the zone at a comfortable temperature to begin the day. (This will be a higher temperature during the heating season, or a lower temperature during the cooling season.) This is the only period that must contain a time and temperature for every day. MIDDAY is the time period you can set for an energysaving temperature while the zone is unoccupied. (This will be a lower temperature during the heating season, or a higher temperature during the cooling season.) EVENING is the time period when you want the zone at a comfortable temperature for family activities in the evening. NIGHT is the time period you can set for an energysaving temperature while you are sleeping or the zone is unoccupied. Set it to start at your family's normal bedtime. (For more comfortable sleeping in the cooling season, some people choose not to raise the cooling temperature during the night.) You can set a different schedule for each day of the week because your requirements will probably be different for each day. Fill in the times and temperatures you desire for each day of the week. If you decide not to program the
6
69-0819
thermostat, it will automatically control heating from 6:00 AM to 10:00 PM at 70° F [21° C]. The temperature will be 60° F [16° C] from 10:00 PM to 6:00 AM. Cooling is automatically controlled at 78° F [26° C] 24 hours a day. Also, you do not need to enter a time and temperature program for all periods if your schedule does not require it. For example, a zone that is occupied Monday and Tuesday only requires programs for MORNING and NIGHT. PROGRAM SCHEDULE
Sunday MORNING MIDDAY EVENING NIGHT Start Time ÂÂÂÂÂÂÂÂÂÂÂÂÂÂÂÂÂÂÂÂÂ ÂÂÂÂÂÂÂÂÂÂÂÂÂÂÂÂÂÂÂÂÂ ÂÂÂÂÂÂÂÂÂÂÂÂÂÂÂÂÂÂÂÂÂ ÂÂÂÂÂÂÂÂÂÂÂÂÂÂÂÂÂÂÂÂÂ
1
IMPORTANT: Always press the keys with your finger or similar blunt tool. Use of sharp instruments like a pen or pencil point can damage the keyboard. If you make an error at any time during programming, just press the RUN PROGRAM key, and continue at the step where you left off.
Heating Temp ÂÂÂÂÂÂÂÂÂÂÂÂÂÂÂÂÂÂÂÂÂÂ ÂÂÂÂÂÂÂÂÂÂÂÂÂÂÂÂÂÂÂÂÂÂ ÂÂÂÂÂÂÂÂÂÂÂÂÂÂÂÂÂÂÂÂÂÂ ÂÂÂÂÂÂÂÂÂÂÂÂÂÂÂÂÂÂÂÂÂÂ
Cooling Temp ÂÂÂÂÂÂÂÂÂÂÂÂÂÂÂÂÂÂÂÂÂÂ ÂÂÂÂÂÂÂÂÂÂÂÂÂÂÂÂÂÂÂÂÂÂ ÂÂÂÂÂÂÂÂÂÂÂÂÂÂÂÂÂÂÂÂÂÂ ÂÂÂÂÂÂÂÂÂÂÂÂÂÂÂÂÂÂÂÂÂÂ
1
1 See footnote on page 9.
7
69-0819
Monday MORNING MIDDAY EVENING NIGHT Tuesday MORNING MIDDAY EVENING NIGHT Wednesday MORNING MIDDAY EVENING NIGHT
Start Time ÂÂÂÂÂÂÂÂÂÂÂÂÂÂÂÂÂÂÂÂÂ ÂÂÂÂÂÂÂÂÂÂÂÂÂÂÂÂÂÂÂÂÂ ÂÂÂÂÂÂÂÂÂÂÂÂÂÂÂÂÂÂÂÂÂ ÂÂÂÂÂÂÂÂÂÂÂÂÂÂÂÂÂÂÂÂÂ ÂÂÂÂÂÂÂÂÂÂÂÂÂÂÂÂÂÂÂÂÂ ÂÂÂÂÂÂÂÂÂÂÂÂÂÂÂÂÂÂÂÂÂ ÂÂÂÂÂÂÂÂÂÂÂÂÂÂÂÂÂÂÂÂÂ ÂÂÂÂÂÂÂÂÂÂÂÂÂÂÂÂÂÂÂÂÂ ÂÂÂÂÂÂÂÂÂÂÂÂÂÂÂÂÂÂÂÂÂ ÂÂÂÂÂÂÂÂÂÂÂÂÂÂÂÂÂÂÂÂÂ ÂÂÂÂÂÂÂÂÂÂÂÂÂÂÂÂÂÂÂÂÂ ÂÂÂÂÂÂÂÂÂÂÂÂÂÂÂÂÂÂÂÂÂ
Heating Temp ÂÂÂÂÂÂÂÂÂÂÂÂÂÂÂÂÂÂÂÂÂÂ ÂÂÂÂÂÂÂÂÂÂÂÂÂÂÂÂÂÂÂÂÂÂ ÂÂÂÂÂÂÂÂÂÂÂÂÂÂÂÂÂÂÂÂÂÂ ÂÂÂÂÂÂÂÂÂÂÂÂÂÂÂÂÂÂÂÂÂÂ ÂÂÂÂÂÂÂÂÂÂÂÂÂÂÂÂÂÂÂÂÂÂ ÂÂÂÂÂÂÂÂÂÂÂÂÂÂÂÂÂÂÂÂÂÂ ÂÂÂÂÂÂÂÂÂÂÂÂÂÂÂÂÂÂÂÂÂÂ ÂÂÂÂÂÂÂÂÂÂÂÂÂÂÂÂÂÂÂÂÂÂ ÂÂÂÂÂÂÂÂÂÂÂÂÂÂÂÂÂÂÂÂÂÂ ÂÂÂÂÂÂÂÂÂÂÂÂÂÂÂÂÂÂÂÂÂÂ ÂÂÂÂÂÂÂÂÂÂÂÂÂÂÂÂÂÂÂÂÂÂ ÂÂÂÂÂÂÂÂÂÂÂÂÂÂÂÂÂÂÂÂÂÂ
1
Cooling Temp ÂÂÂÂÂÂÂÂÂÂÂÂÂÂÂÂÂÂÂÂÂÂ ÂÂÂÂÂÂÂÂÂÂÂÂÂÂÂÂÂÂÂÂÂÂ ÂÂÂÂÂÂÂÂÂÂÂÂÂÂÂÂÂÂÂÂÂÂ ÂÂÂÂÂÂÂÂÂÂÂÂÂÂÂÂÂÂÂÂÂÂ ÂÂÂÂÂÂÂÂÂÂÂÂÂÂÂÂÂÂÂÂÂÂ ÂÂÂÂÂÂÂÂÂÂÂÂÂÂÂÂÂÂÂÂÂÂ ÂÂÂÂÂÂÂÂÂÂÂÂÂÂÂÂÂÂÂÂÂÂ ÂÂÂÂÂÂÂÂÂÂÂÂÂÂÂÂÂÂÂÂÂÂ ÂÂÂÂÂÂÂÂÂÂÂÂÂÂÂÂÂÂÂÂÂÂ ÂÂÂÂÂÂÂÂÂÂÂÂÂÂÂÂÂÂÂÂÂÂ ÂÂÂÂÂÂÂÂÂÂÂÂÂÂÂÂÂÂÂÂÂÂ ÂÂÂÂÂÂÂÂÂÂÂÂÂÂÂÂÂÂÂÂÂÂ
1
1 See footnote on page 9.
8
69-0819
Thursday MORNING MIDDAY EVENING NIGHT Friday MORNING MIDDAY EVENING NIGHT Saturday MORNING MIDDAY EVENING NIGHT
Start Time ÂÂÂÂÂÂÂÂÂÂÂÂÂÂÂÂÂÂÂÂÂ ÂÂÂÂÂÂÂÂÂÂÂÂÂÂÂÂÂÂÂÂÂ ÂÂÂÂÂÂÂÂÂÂÂÂÂÂÂÂÂÂÂÂÂ ÂÂÂÂÂÂÂÂÂÂÂÂÂÂÂÂÂÂÂÂÂ ÂÂÂÂÂÂÂÂÂÂÂÂÂÂÂÂÂÂÂÂÂ ÂÂÂÂÂÂÂÂÂÂÂÂÂÂÂÂÂÂÂÂÂ ÂÂÂÂÂÂÂÂÂÂÂÂÂÂÂÂÂÂÂÂÂ ÂÂÂÂÂÂÂÂÂÂÂÂÂÂÂÂÂÂÂÂÂ ÂÂÂÂÂÂÂÂÂÂÂÂÂÂÂÂÂÂÂÂÂ ÂÂÂÂÂÂÂÂÂÂÂÂÂÂÂÂÂÂÂÂÂ ÂÂÂÂÂÂÂÂÂÂÂÂÂÂÂÂÂÂÂÂÂ ÂÂÂÂÂÂÂÂÂÂÂÂÂÂÂÂÂÂÂÂÂ
Heating Temp ÂÂÂÂÂÂÂÂÂÂÂÂÂÂÂÂÂÂÂÂÂÂ ÂÂÂÂÂÂÂÂÂÂÂÂÂÂÂÂÂÂÂÂÂÂ ÂÂÂÂÂÂÂÂÂÂÂÂÂÂÂÂÂÂÂÂÂÂ ÂÂÂÂÂÂÂÂÂÂÂÂÂÂÂÂÂÂÂÂÂÂ ÂÂÂÂÂÂÂÂÂÂÂÂÂÂÂÂÂÂÂÂÂÂ ÂÂÂÂÂÂÂÂÂÂÂÂÂÂÂÂÂÂÂÂÂÂ ÂÂÂÂÂÂÂÂÂÂÂÂÂÂÂÂÂÂÂÂÂÂ ÂÂÂÂÂÂÂÂÂÂÂÂÂÂÂÂÂÂÂÂÂÂ ÂÂÂÂÂÂÂÂÂÂÂÂÂÂÂÂÂÂÂÂÂÂ ÂÂÂÂÂÂÂÂÂÂÂÂÂÂÂÂÂÂÂÂÂÂ ÂÂÂÂÂÂÂÂÂÂÂÂÂÂÂÂÂÂÂÂÂÂ ÂÂÂÂÂÂÂÂÂÂÂÂÂÂÂÂÂÂÂÂÂÂ
1
Cooling Temp ÂÂÂÂÂÂÂÂÂÂÂÂÂÂÂÂÂÂÂÂÂÂ ÂÂÂÂÂÂÂÂÂÂÂÂÂÂÂÂÂÂÂÂÂÂ ÂÂÂÂÂÂÂÂÂÂÂÂÂÂÂÂÂÂÂÂÂÂ ÂÂÂÂÂÂÂÂÂÂÂÂÂÂÂÂÂÂÂÂÂÂ ÂÂÂÂÂÂÂÂÂÂÂÂÂÂÂÂÂÂÂÂÂÂ ÂÂÂÂÂÂÂÂÂÂÂÂÂÂÂÂÂÂÂÂÂÂ ÂÂÂÂÂÂÂÂÂÂÂÂÂÂÂÂÂÂÂÂÂÂ ÂÂÂÂÂÂÂÂÂÂÂÂÂÂÂÂÂÂÂÂÂÂ ÂÂÂÂÂÂÂÂÂÂÂÂÂÂÂÂÂÂÂÂÂÂ ÂÂÂÂÂÂÂÂÂÂÂÂÂÂÂÂÂÂÂÂÂÂ ÂÂÂÂÂÂÂÂÂÂÂÂÂÂÂÂÂÂÂÂÂÂ ÂÂÂÂÂÂÂÂÂÂÂÂÂÂÂÂÂÂÂÂÂÂ
1
1 Heating and cooling temperatures must be at least 3° F apart for proper control in the AUTO mode.
9
69-0819
SELECT ONE DAY'S PROGRAM TO COPY TO ANOTHER DAY SET THE TIME EARLIER SELECT AND SET A PROGRAM PERIOD RETURN TO THE PROGRAM
AM
ROOM WED MIDDAY HEAT ON
SEE THE CURRENT SETTING
SYSTEM
SET A WARMER TEMPERATURE
SET CURRENT DAY AND TIME
RUN PROGRAM TIME SET PRESENT DAY/TIME COPY FROM
TEMPERATURE PRESENT SETTING
DAY
PERIOD
AHEAD
WARMER
SKIP NEXT PERIOD CHANGE TO LAST PERIOD
SKIP THE NEXT PROGRAM PERIOD
MANUALLY OPERATE THE THERMOSTAT
HOLD TEMP
SET HEAT/COOL
CANCEL PERIOD
COPY TO
BACK
COOLER
FAN
CHANGE THE PROGRAM BACK TO THE LAST SETTTING
EM. HT HEAT OFF
AUTO COOL
EM. HT
AUX. HT
CHECK
ON
AUTO
CANCEL A PROGRAM PERIOD SELECT A DAY TO COPY A PROGRAM TO SET THE TIME LATER
SET A COOLER TEMPERATURE
M8368
10
69-0819
SET CURRENT DAY AND TIME 1. To set the day, press and release SET PRESENT DAY/TIME key. 2. Press and hold DAY key until the current day appears in the display. 3. To set the time, press and release SET PRESENT DAY/TIME key. 4. Press and hold AHEAD or BACK key until the current time appears in the display. Make sure AM or PM appears as desired. 5. Press RUN PROGRAM key. HEATING PROGRAM Choose a day to program first. Monday is used in the following example, but you can start with any day. Start by programming the MORNING time and temperatures. The thermostat requires a MORNING progra ...
|