Preview of the first 3 pages of manual
You either have JavaScript turned off or an old version of Adobe Flash Player Get the latest Flash Player.
User guide HONEYWELL VISIONPRO IAQ
Detailed instructions for use are in the User's Guide. Operating Manual Mode d'emploi Manual de Uso
VisionPRO IAQ
®
Total Home Comfort System
69-1815EFS-1
BE CAREFUL! Never use sharp instruments, such as a pencil or pen, to press touchscreen keys. To prevent damage to the thermostat, always press keys with your fingertip.
Need Help?
For assistance with this product please visit http://yourhome.honeywell.com or call Honeywell Customer Care toll-free at 1-800-468-1502
Read and save these instructions.
® U.S. Registered Trademark. US Patent No. 6,208,263; 6,373,376; 6,448,901; 6,926,076; D509151; H25192; H25193 and other patents pending. Copyright © 2006 Honeywell International Inc. All rights reserved.
VisionPRO IAQ
®
Table of contents
About your new thermostat
Programming at a glance ..................... 2 Quick reference to controls .................. 3 Quick reference to status display ........ 4 Clock setting.......................................... 5 Fan setting ............................................. 6 System setting....................................... 7 Energy Star settings .............................. 8 Using program schedules ..................... 9 Program schedule overrides .............. 10 Vacation hold ....................................... 12 Special features................................... 13 Screen lock .......................................... 14 Screen cleaning ................................... 15 Optional remote sensors .................... 16 Humidity control .................................. 17 Ventilation control................................ 19
Appendices
Advanced functions ............................ 20 In case of difficulty .............................. 27 Limited warranty.................................. 29
Programming & Operation
This thermostat is ready to go!
Your new thermostat is preprogrammed and ready to go. See page 2 to check settings.
CAUTION: EQUIPMENT DAMAGE HAZARD. To prevent possible compressor damage, do not operate cooling system when outdoor temperature is below 50°F (10°C).
Operating Manual
About your new thermostat
Your new thermostat is pre-programmed and ready to go. Just set the time and day. Then check the settings below and change if needed: 1. Set clock........................................................................................................See page 5 2. Select fan setting: Preset to Auto ..............................................................See page 6 3. Select system setting: Preset to Heat ......................................................See page 7 4. Program schedules: Preset to energy-saving levels while you're at work or asleep (assumes you wake at 6 am, leave at 8 am, return at 6 pm and go to bed at 10 pm) ........................................................................ See pages 8-11 5. Set humification, dehumidification & ventilation controls, if applicable ............................................... See pages 17-19
ONE-TOUCH TEMP CONTROL: You can override the program schedule at any time, and manually adjust the temperature (see pages 10-11).
VisionPRO IAQ
®
Quick reference to controls
Press day(s) to set program schedule (see page 9) Press to select fan operation (see page 6) Press to select system type (see page 7) Press to adjust temperature settings (see pages 9-11) Press for more options
MON
FAN AUTO
TUE
WED
THU
FRI
SAT
SUN
OK TO PICK MULTIPLE DAYS
Inside
70
HOLD
Set To
70
SYSTEM
HEAT
Following Schedule
Press to set program schedule (see page 9)
6:01
SCHED
AM
CLOCK
SCREEN
MORE
Press to override program schedule (see pages 10-11)
Press to set clock (see page 5)
Press to lock keypad for 30 seconds to clean screen (see page 14)
Operating Manual
Quick reference to status display
Current inside temperature Current day of week Temperature setting
WED
FAN
Fan setting System setting Current time Other display messages: · · · · ·
Inside
AUTO
70
AM
Set To
70
Recovery
Program schedule on (does not display when off) Adaptive Intelligent Recovery in effect (see page 13) Inside humidity (If an outdoor sensor is installed, the outdoor temperature is shown instead of the humidity level. Press MORE to display the humidity level.)
SYSTEM
HEAT
Following Schedule
6:01
SCHED
55
Humidity
HOLD
CLOCK
SCREEN
MORE
Cool On: Cooling system is activated Heat On: Heating system is activated Aux Heat On: Auxiliary heating system is activated Wait: Compressor protection activated (see page 13) Screen Locked: See page 26 to unlock
VisionPRO IAQ
®
Clock setting Inside
FAN AUTO
WED
Press CLOCK
70
WED HOLD
Set To
70
6:01
SCHED
FAN AUTO
AM
To set the current time display, press CLOCK, then press s or t to adjust the time. Press and hold s or t to advance the time more quickly. Press DONE to save & exit (or press CANCEL to exit without changing the time).
Note: The real-time clock should never require adjustment since it automatically updates for daylight savings time, and stores all date/time information. Note: To change the current week day display, see page 21.
CANCEL
CLOCK
SCREEN
MORE
Inside
Adjust time, then press DONE
70
Set To
70
6:02
DONE
AM
Operating Manual
Fan setting
WED
FAN AUTO
Press FAN to select fan operation:
Set To
Inside
70
AM
70
· On: Fan is always on. · Auto: Fan runs only when the heating or cooling system is on. · Circ: Fan runs randomly, about 35% of the time. Use this setting for improved air circulation, or for more efficient air cleaning, if you do not want the fan to run all the time. You can press FAN to override the fan settings you've programmed for different time periods (see page 9). If you select On or Circ, the setting you select will remain active until you press FAN again to select Auto, and return to the fan schedule.
SYSTEM
HEAT
Following Schedule
6:01
SCHED
HOLD
CLOCK
SCREEN
MORE
Press FAN
Note: If a fan schedule is programmed, "Auto" will run the fan schedule.
VisionPRO IAQ
®
System setting
WED
FAN AUTO
Press the SYSTEM button to select:
Set To
Inside
70
AM
70
· Heat: Thermostat controls only the heating system. · Cool: Thermostat controls only the cooling system. · Off: Heating and cooling systems are off. · Auto: Thermostat automatically selects heating or cooling depending on the indoor temperature. · Em Heat (only for heat pumps with auxiliary heat): Thermostat controls Auxiliary Heat. Compressor is not used.
SYSTEM
HEAT
Following Schedule
6:01
SCHED
HOLD
CLOCK
SCREEN
MORE
Press SYSTEM
Operating Manual
EnergyStar settings for maximum cost savings
®
It's easy to program your system for maximum energy savings. You can program four time periods each day, with different settings for each day. This thermostat is pre-set to use EnergyStar program settings. We recommend these settings, since they can reduce your heating/cooling expenses by as much as 33%. (See next page to adjust times and temperatures of each time period.)
®
Heat (Mon-Fri)
Wake (6:00 am) Leave (8:00 am) Return (6:00 pm) Sleep (10:00 pm)
Cool (Mon-Fri)
Heat (Sat-Sun)
Cool (Sat-Sun)
70 ° 62 ° 70 ° 62 °
78 ° 85 °
[Or cancel period]
78 °
82
[Or cancel period]
°
70 ° 62 ° 70 ° 62 °
[Or cancel period]
[Or cancel period]
78 ° 85 ° 78 ° 82 °
FAN AUTO
Inside
To adjust program schedules
WED
70
HOLD
Set To
70
70
VisionPRO IAQ
®
Following Schedule
FAN
AUTO Press SCHED
Inside
6:00 70
AM
Set To
SCHED
CLOCK
Following SCREEN MORE Schedule
Press EDIT
DONE EDIT
6:00
WAKE
AM
LEAVE
RETURN
SLEEP
CANCEL
Select day(s)
MON
FAN AUTO
Set heat/cool levels
WED THU FRI SAT SUN
TUE
OK TO PICK MULTIPLE DAYS
70
CANCEL PERIOD
HEAT
1. Press SCHED, then EDIT. 2. Press day buttons (MON-SUN) to select day(s). 3. Press s or t to set your Wake time for selected day(s). 4. Press s or t to set Heat and Cool temperature for this time period. 5. Press other time periods (LEAVE, RETURN, SLEEP) to set time and temperatures for each. 6. Press DONE to save & exit (or press CANCEL to exit without saving changes).
Note: You can press CANCEL PERIOD to eliminate any unwanted time period.
6:00
DONE WAKE
AM
78
LEAVE RETURN SLEEP
COOL
CANCEL
Note: Press FAN to customize fan settings for any time period (see page 6).
Set time for program period to start
Operating Manual
Program schedule override (temporary)
Adjust temperature
WED
FAN AUTO
Press s or t to immediately adjust the temperature. This will temporarily override the temperature setting for the current time period. The new temperature will be maintained only until the time you set. When the timer expires, the program schedule will resume and set the temperature to the level you've programmed for the current time period. To cancel the temporary setting at any time, press CANCEL (or SCHED). The program schedule will resume.
Inside
70
AM
Set To
73
HEAT
Heat On
SYSTEM
HEAT
Hold Temperature Until
8:00
HOLD
78
CLOCK SCREEN MORE
COOL
SCHED
CANCEL
Press to set timer Press CANCEL (or SCHED) to resume program schedule
0
VisionPRO IAQ
®
Program schedule override (permanent)
Press HOLD Adjust temperature
WED
FAN AUTO
Press HOLD to permanently adjust the temperature. This will turn off the program schedule. Whatever temperature you set will be maintained 24 hours a day until you manually change it or press CANCEL (or SCHED) to cancel "Hold" and resume the program schedule.
Inside
70
AM
Set To
73
Heat On
SYSTEM
HEAT
8:00
Permanent Hold
SCHED
HOLD
CLOCK
SCREEN
MORE CANCEL
Press CANCEL (or SCHED) to resume program schedule
Operating Manual
Vacation hold
1WED temperature Set
FAN AUTO
Inside
70
PM
Set To
55
This feature can suspend the program schedule for extended periods of time. Press s or t to set the temperature you want, then press s or t to set the time of day you want the schedule to resume when you return. Press HOLD twice, then press s or t to select the number of days.
CANCEL
SYSTEM
HEAT
Hold Temperature Until
6:00
SCHED
HOLD
CLOCK
SCREEN
MORE
WED
FAN
2 Press to set time for Set To schedule to resume 3 AUTO Press HOLD twice
Inside
70
14
HOLD
55
Whatever temperature you set will be maintained 24 hours a day for the number of days you select. After this number of days have elapsed, the previously programmed schedule will resume at the time you set. If you return earlier than expected, press CANCEL (or SCHED) to cancel "Hold" and resume the program schedule.
SYSTEM
HEAT
Hold Temperature Until DAYS
SCHED
CLOCK
SCREEN
MORE CANCEL
4 Press to select number of days
VisionPRO IAQ
®
Special features
Auto Changeover: When set to Auto, the thermostat automatically selects heating or cooling depending on the indoor temperature. Adaptive Intelligent Recovery: This feature allows the thermostat to "learn" how long the furnace and air conditioner take to reach programmed temperature settings, so the temperature is reached at the time you set. Compressor Protection: This feature forces the compressor to wait a few minutes before restarting, to prevent equipment damage. During the wait time, the message "Wait" is displayed on screen. Flashing message: Reminder to replace filter or UV lamp. After replacement, press RESET to reactivate the alert timer. Southern Away Dehumidification: Your system may be programmed to control humidity while your house is vacant during the humid season. Before you leave the house, press the HOLD button three times to activate this feature. This will control temperature and humidity to help protect your house and possessions while you are away. (If this feature does not work, contact your installer.)
Operating Manual
Screen lock
WED
FAN AUTO
Inside
70
PM
SCREEN LOCKED
To prevent tampering, the screen can be partially or fully locked. When partially locked, the screen displays SCREEN LOCKED for several seconds if a locked key is pressed. When the screen is fully locked, no keys function. To lock or unlock the screen, see advanced function 0670 on page 26.
Set To
70
SYSTEM
HEAT
Following Schedule
6:00
SCHED
43
CLOCK SCREEN MORE
HOLD
See advanced function 0670 (page 26) for screen lock options
WED
VisionPRO IAQ
®
Screen cleaning
FAN
Inside
AUTO
Press SCREEN
70
HOLD
SCREEN LOCKED
Set To
70
Press SCREEN to lock the screen for cleaning. The screen will remain locked for 30 seconds so you can clean the screen without changing any settings. After 30 seconds, press DONE to resume normal operation, or press SCREEN again if you require more time for cleaning.
Note: Do not spray any liquid directly on the thermostat. Spray liquids onto a cloth, then use the damp cloth to clean the screen. Use water or household glass cleaner. Avoid abrasive cleansers.
Following Schedule
6:00
SCHED
PM
CLOCK
SCREEN
MORE
Screen lock timer (30 seconds)
30
SCHED HOLD
OK TO CLEAN SCREEN
CLOCK
SCREEN
MORE
Operating Manual
Optional remote sensors
WED
FAN AUTO
If an outdoor sensor is installed, the current outdoor temperature is displayed.
Set To
Inside
70
AM
70
Outside
SYSTEM
HEAT
Following Schedule
If an indoor remote sensor is installed, the display shows the indoor temperature at the location of the sensor. If more than one indoor sensor is installed, the display shows an average of temperature readings from all sensors or an average between the thermostat and the sensor(s).
6:01
SCHED
43
CLOCK SCREEN
HOLD
MORE
Inside temperature
Outside temperature
VisionPRO IAQ
®
Humidification control
Set Frost Control & humidity level
Press MORE until the humidifier screen is displayed, then press s or t to set the humidity and Frost Control level. When using Frost Protection, if frost/condensation appears on windows, lower the frost setting. Wait at least 1 day before adjusting the frost level again. Once frost no longer appears, the thermostat will control humidity to the maximum level without frosting or fogging windows and without further adjustment. Press DONE to save and exit, or press CANCEL to exit without saving changes.
Note: If you do not have an outdoor temperature sensor, the Frost Control level will not be displayed.
Inside
32
5
FROST
DEHUMIDIFIER
55
DONE CANCEL
Press to save & exit
Operating Manual
Dehumidification control
Press to select Auto or Off Press to set desired humidity
Press MORE until the dehumidifier screen is displayed, then press s or t to set the desired humidity level and operation (Auto or Off). If installed to control a dehumidifier, the thermostat can activate it as needed to reduce humidity.
Inside
73
DEHUMIDIFIER
AUTO
DONE
55
CANCEL
If you don't have a dehumidifier, the thermostat activates the air conditioner to reduce humidity (may cool as much as 3°F lower than your temperature setting). Press DONE to save and exit, or press CANCEL to exit without saving changes.
Press to save & exit Note: Auto/Off only present when using a whole house dehumidifier (not present when dehumidifying with A/C).
VisionPRO IAQ
®
Ventilation control
Press to set ventilation timer
You can ventilate your home at any time: Press MORE until the ventilation screen is displayed, then press s or t to set the ventilation timer. You can set the timer to ventilate from 20 to 180 minutes, in 20-minute increments. To turn off the ventilator, select 0.
AUTO
DONE
VENT
40
Minutes
Press DONE to save and exit, or press CANCEL to exit without saving changes.
CANCEL
If programmed for auto-ventilation by the installer, the thermostat will ventilate your home as needed. Auto/Off will turn off/on the automatic ventilation only. Ventilation can still be requested by using the timer when set to Off.
Press to save & exit
Operating Manual
TUE
FAN AUTO
Advanced functions
1
Press SYSTEM.
TUE
FAN AUTO
Inside
2 Press and hold
70
AM
Set To
70
Inside
70
AM
blank center key until the display changes.
SYSTEM
HEAT
6:01
TUE
If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Diplodocs provides you a fast and easy access to the user manual HONEYWELL VISIONPRO IAQ. HONEYWELL offer a product for which we do not have the user manual? Let us know what you are looking for: site Internet, histoire, actualité, filiales, site Internet, mode d'emploi, driver, avis des utilisateurs, meilleur prix des produits, forum d'assistance aux problèmes, annuaire des marques, annuaire des constructeurs, répertoire des marques, répertoire des constructeurs, site Internet de la marque, site Internet du constructeur Diplodocs allows you to download user manual HONEYWELL VISIONPRO IAQ, user guide HONEYWELL VISIONPRO IAQ, instructions HONEYWELL VISIONPRO IAQ, owner's manual HONEYWELL VISIONPRO IAQ, online manual HONEYWELL VISIONPRO IAQ.Access web reviews HONEYWELL VISIONPRO IAQ, , |
![]() |
Include the add-on to download manuals from your site, forum or blog | ![]() |
Frequently Asked Questions | ![]() |
Contact Diplodocs team | ![]() |
Last searches Last additions |
![]() |
Sitemap | ![]() |
|||
| Brands starting with A B C D E F G H I J K L M N O P Q R S T U V W X Y Z # | |||||||||||||
|
|
Copyright © 2005 - 2008 - Diplodocs -
All Rights Reserved. Designated trademarks and brands are the property of their respective owners. |