9 562 brands
2 694 000 user's guides


Download your manual, it's FREE! Diplodocs allows you to download several types of document in order to best use your HONEYWELL VISIONPRO TH8000 : user manual, user guide, instruction manual.
Search a brand
Advanced Search

User manual HONEYWELL VISIONPRO TH8000

Diplodocs help download the user guide HONEYWELL VISIONPRO TH8000 .

Download the complete user guide (963 Ko)



This product, although classified under the brand HONEYWELL, may have been manufactured by ADEMCO, DOMONIAL, ENVIRACAIRE, FBII, FISHER PRICE, GALAXY, INTELLISENSE, RELI ON after mergers, acquisitions, or a change in name.


The HONEYWELL VISIONPRO TH8000 forum

Preview of the first 3 pages of manual

You either have JavaScript turned off or an old version of Adobe Flash Player
Get the latest Flash Player.
Manual abstract: user guide HONEYWELL VISIONPRO TH8000

Detailed instructions for use are in the User's Guide.

Operating Manual VisionPRO® TH8000 Series Touchscreen Programmable Thermostat BE CAREFUL! Never use sharp instruments, such as a pencil or pen, to press touchscreen keys. To prevent damage to the thermostat, always press keys with your fingertip. This manual covers the following models TH8110U: For 1 Heat/1 Cool systems TH8320U: For up to 3 Heat/2 Cool systems TH8321U: For up to 3 Heat/2 Cool systems with dehumidification (Pull thermostat from wallplate and turn over to find model number) Need Help? For assistance with this product please visit http://yourhome.honeywell.com or call Honeywell Customer Care toll-free at 1-800-468-1502 Read and save these instructions ® U.S. Registered Trademark. US Patent No. 6595430, D509151 and other patents pending. Copyright © 2006 Honeywell International Inc. All rights reserved. VisionPRO® TH8000 Series Table of contents About your new thermostat Thermostat features ..........................2 Programming at a glance..................3 Quick reference to controls ..............4 Quick reference to status display ....5 Appendices Battery installation ..........................20 Advanced functions ........................21 In case of difficulty ..........................26 Optional remote sensors ................28 Limited warranty ..............................29 Programming & Operation Clock setting ......................................6 Fan setting ........................................7 System setting....................................8 Using program schedules ................9 Program schedule overrides ..........12 Vacation hold ..................................14 Special features ..............................15 Screen lock ......................................16 Screen cleaning ..............................17 Humidity display & control ..............18 This thermostat is ready to go! Your new thermostat is preprogrammed and ready to go. See page 3 to check settings. CAUTION: EQUIPMENT DAMAGE HAZARD. To prevent possible compressor damage, do not operate cooling system when outdoor temperature is below 50°F (10°C). 1 Operating Manual About your new thermostat Congratulations! You've just purchased the world's most advanced, easyto-use thermostat. It has been designed to give you many years of reliable service and touchscreen climate control. Features · · · · · · · · · 7-day program schedules maximize comfort and economy. Armchair programming: Just pull thermostat from the wall to set schedules. EnergyStar® compliant to greatly reduce your heating/cooling expenses. One-touch temp control overrides program schedule at any time. Precise comfort control keeps temperature within 1°F of the level you set. Change/check reminders let you know when to service or replace filters, batteries and other critical components. Large touchscreen display with backlight is easy to read -- even in the dark. Select models display and control summer humidity. Select models accommodate optional outdoor or indoor remote sensors. 2 VisionPRO® TH8000 Series This thermostat is ready to go! Your new thermostat is pre-programmed and ready to go. All you have to do is set the time and day. Then check the settings below and change if needed: 1 2 3 4 Set clock......................................................................................See page 6 Select fan setting: Preset to Auto ........................To change, see page 7 Select system setting: Preset to Heat ..................To change, see page 8 Program schedules: Preset to energy-saving levels while you're at work or asleep (assumes you wake at 6 am, leave at 8 am, return at 6 pm and go to bed at 10 pm) ..................................To change, see pages 10-13 ONE-TOUCH TEMP CONTROL: You can override the program schedule at any time, and manually adjust the temperature (see pages 12-14). 3 Operating Manual Quick reference to controls Press day(s) to set program schedule (see page 11) Press to adjust temperature settings (see pages 11-14) Press to select fan operation (see page 7) Press to select system type (see page 8) MON FAN AUTO TUE WED THU FRI SAT SUN OK TO PICK MULTIPLE DAYS Inside 70 AM HOLD CLOCK Set To 70 Press for more options (select models only) SYSTEM HEAT Following Schedule Press to set program schedule (see page 11) 6:01 SCHED SCREEN MORE Press to override program schedule (see pages 12-14) Press to set clock (see page 6) Press to lock keypad for 30 seconds to clean screen (see page 17). 4 VisionPRO® TH8000 Series Quick reference to status display Current inside temperature Current day of week Temperature setting WED FAN Inside Fan setting AUTO 70 AM HOLD CLOCK Set To 70 SYSTEM Following Schedule Recovery Program schedule on (does not display when off) Adaptive Intelligent Recovery in effect (see page 15) System setting HEAT 6:01 SCHED SCREEN MORE Current time Other display messages: · · · Cool On: Cooling system is activated Heat On: Heating system is activated Aux Heat On: Auxiliary heating system is activated 5 Operating Manual Clock setting Press CLOCK 6:01 SCHED AM HOLD CLOCK SCREEN MORE To set the current time display, press clock, then press or to adjust the time. Press and hold or to advance the time more quickly. Press CANCEL DONE to save & exit (or press to exit without changing the time). Adjust time, then press DONE 6:02 DONE AM CANCEL Note: The real-time clock should never require adjustment since it automatically updates for daylight savings time, and stores all date/time information. Note: To change the current week day display, see page 22. 6 VisionPRO® TH8000 Series Fan setting Press WED FAN AUTO FAN to select fan operation: · Inside On: Fan is always on. Auto: Fan runs only when the heating or cooling system is on. Circ: Fan runs randomly, about 35% of the time. Use this setting for improved air circulation, or for more efficient air cleaning, if you do not want the fan to run all the time. 70 AM HOLD CLOCK Set To 70 · · SYSTEM HEAT Following Schedule 6:01 SCHED SCREEN MORE Press FAN You can press FAN at any time to override the fan settings you've programmed for different time periods (see page 11). If you select On or Circ, the setting you select will remain active until you press FAN again to select Auto. 7 Operating Manual System setting Press the WED FAN AUTO SYSTEM button to select: · Inside 70 AM HOLD CLOCK Set To 70 · · SYSTEM HEAT Following Schedule 6:01 SCHED SCREEN MORE · · Heat: Thermostat controls only the heating system. Cool: Thermostat controls only the cooling system. Off: Heating and cooling systems are off. Auto: Thermostat automatically selects heating or cooling depending on the indoor temperature. ** Em Heat (only for heat pumps with auxiliary heat): Thermostat controls Emergency and Auxiliary Heat. Compressor is locked out. ** ** Select models only 8 VisionPRO® TH8000 Series Save money by setting program schedules It's easy to program your system for maximum energy savings. You can program four time periods each day, with different settings for weekdays and weekends. WAKE 6:00 am 70 ° LEAVE 8:00 am Set to the time you awaken and the temperature you want during the morning, until you leave for the day. Set to the time you leave home and the temperature you want while you are away (usually an energy-saving ° level). RETURN Set to the time you return home and the temperature 6:00 pm you want during the evening, until bedtime. 62 70 ° SLEEP 10:00 pm 62 ° Set to the time you go to bed and the temperature you want overnight (usually an energy-saving level). 9 Operating Manual EnergyStar® settings for maximum cost savings This thermostat is pre-set to use EnergyStar® program settings. We recommend these settings, since they can reduce your heating/cooling expenses by as much as 33%. (See next page to adjust times and temperatures of each time period.) Heat (Mon-Fri) Wake (6:00 am) Cool (Mon-Fri) Heat (Sat-Sun) Cool (Sat-Sun) Leave (8:00 am) Return (6:00 pm) Sleep (10:00 pm) 70 ° 62 ° 70 ° 62 ° 78 ° 85 ° 78 ° 82° [Or cancel period] [Or cancel period] 70 ° 62 ° 70 ° 62 ° [Or cancel period] [Or cancel period] 78 ° 85 ° 78 ° 82° 10 VisionPRO® TH8000 Series To adjust program schedules Press SCHED SCHED HOLD CLOCK SCREEN MORE Press DONE EDIT EDIT WAKE LEAVE RETURN SLEEP CANCEL Select day(s) MON FAN AUTO CANCEL PERIOD TUE WED Set heat/cool levels THU FRI SAT SUN OK TO PICK MULTIPLE DAYS 70 6:00 78 AM LEAVE RETURN SLEEP HEAT 1 Press SCHED, then EDIT. M 2 Press day buttons (MON-SUN) to select day(s). 3 Press or to set Wake time for selected day(s). 4 Press or to set Heat and Cool temperature for this time period. L 5 Press other time periods (LEAVE, RETURN, SLEEP) to set time and temperatures for each. 6 Press DONE to save & exit (or press CANCEL to exit without saving changes). Note: You can press CANCEL PERIOD to eliminate any unwanted time period. Note: Press FAN to customize fan settings for any time period (see page 7). COOL DONE WAKE CANCEL Set time for program period start 11 Operating Manual Program schedule override (temporary) Adjust temperature WED FAN AUTO Inside 70 AM HOLD CLOCK Set To 73 Press or to immediately adjust the temperature. This will temporarily override the temperature setting for the current time period. The new temperature will be maintained until the time you set. When the timer expires, the program schedule will resume and set the temperature to the level you've programmed for the current time period. To cancel the temporary setting at any time, press CANCEL (or SCHED). The program schedule will resume. Heat On SYSTEM HEAT Hold Temperature Until 8:00 SCHED SCREEN MORE CANCEL Press to set timer Press CANCEL (or SCHED) to resume program schedule 12 VisionPRO® TH8000 Series Program schedule override (permanent) Press HOLD Adjust temperature WED Press HOLD to permanently adjust the temperature. This will turn off the program schedule. Whatever temperature you set will be maintained 24 hours a day, until you manually change it, or press CANCEL (or SCHED) to cancel "Hold" and resume the program schedule. FAN AUTO Inside 70 AM HOLD CLOCK Set To 73 Heat On SYSTEM HEAT 8:00 Permanent Hold SCHED SCREEN MORE CANCEL Press CANCEL (or SCHED) to resume program schedule 13 Operating Manual Vacation hold 1 Set temperature FAN AUTO This feature can suspend the program schedule for extended periods of time. Press or to set the temperature you want, then press or to set the time of day you want the schedule to resume when you return. Press HOLD twice, then press or to select the number of days. Whatever temperature you set will be maintained 24 hours a day for the number of days you select. After this number of days have elapsed, the previously programmed schedule will resume at the time you set. If you return earlier than expected, press CANCEL (or SCHED) to cancel "Hold" and resume the program schedule. 14 Inside 70 HOLD CLOCK Set To 55 SYSTEM HEAT Hold Temperature Until 6:00pm SCHED SCREEN MORE CANCEL 2 Press to set time for schedule to resume 3 Press SYSTEM HEAT HOLD twice Hold Temperature Until 14 SCHED HOLD DAYS CLOCK SCREEN MORE CANCEL 4 Press to select number of days VisionPRO® TH8000 Series Special features Auto Changeover: When set to Auto, the thermostat automatically selects heating or cooling depending on the indoor temperature. Adaptive Intelligent Recovery: This feature allows the thermostat to "learn" how long the furnace and air conditioner take to reach programmed temperature settings, so the temperature is reached at the time you set. For example: Set the Wake time to 6 am, and the temperature to 70°. The heat will come on before 6 am, so the temperature is 70° by the time you wake at 6. The message "Recovery" is displayed when the system is activated before a scheduled time period. Compressor Protection: This feature forces the compressor to wait a few minutes before restarting, to prevent equipment damage. During the wait time, the message "Wait" is displayed on screen. 15 Operating Manual Screen lock WED SCREEN LOCKED FAN AUTO Inside To prevent tampering, the screen can be partially or fully locked. When partially locked, the screen displays SCREEN LOCKED for several seconds if a locked key is pressed. To unlock the screen, press any unlocked key while SCREEN LOCKED appears on the screen. When the screen is fully locked, no keys function. To lock or unlock the screen, see advanced function 0670 on page 25). 70 PM HOLD CLOCK Set To 70 SYSTEM HEAT Following Schedule 6:00 SCHED SCREEN MORE See advanced function 0670 (page 25) for screen lock options 16 VisionPRO® TH8000 Series Screen cleaning Press SCREEN 6:00 SCHED PM Press SCREEN to lock the screen for cleaning. The screen will remain locked for ...

  Know our Partners   Frequently Asked Questions   Contact Diplodocs team   Last searches
Latest additions
  Sitemap
Brands starting with A B C D E F G H I J K L M N O P Q R S T U V W X Y Z #
Copyright © 2005 - 2008 - Diplodocs - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.