User manual IDEAL 61732

Diplodocs help download the user guide IDEAL 61732 .

Download the complete user guide (531 Ko)





Preview of the first 3 pages of manual

You either have JavaScript turned off or an old version of Adobe Flash Player
Get the latest Flash Player.
Manual abstract: user guide IDEAL 61732

Detailed instructions for use are in the User's Guide.

#61-732 #61-736 400 AAC Clamp Meter Instruction Manual HOLD AC DC APO KMmVA WARNING Read First: Safety Information Understand and follow operating instructions carefully. Use the meter only as specified in this manual; otherwise, the protection provided by the meter may be impaired. WARNING To avoid possible electric shock, personal injury or death, follow these guidelines: · Do not use if meter appears damaged. Visually inspect the meter to ensure case is not cracked and back case is securely in place. · Inspect and replace leads if insulation is damaged, metal is exposed, or probes are cracked. Pay particular attention to the insulation surrounding the connectors. · Do not use meter if it operates abnormally as protection maybe impaired. · Do not use during electrical storms or in wet weather. · Do not use around explosive gas, dust, or vapor. · Do not apply more than the rated voltage to the meter. · Do not use without the battery and the back case properly installed. · Remove the test leads from the circuit prior to removing battery cap. · Do not attempt to repair this unit as it has no user-serviceable parts. Page 2 CAUTION To protect yourself, think "Safety First": · Voltages exceeding 30VAC or 60VDC pose a shock hazard so use caution. · Use appropriate personal protective equipment such as safety glasses, face shields, insulating gloves, insulating boots, and/or insulating mats. · Before each use: - Perform a continuity test by touching the test leads together to verify the functionality of the battery and test leads. - Use the 3 Point Safety Method. (1) Verify meter operation by measuring a known voltage. (2) Apply meter to circuit under test. (3) Return to the known live voltage again to ensure proper operation. · Never ground yourself when taking electrical measurements. · Connect the black common lead to ground or neutral before applying the red test lead to potential voltage. Disconnect the red test lead from the voltage first. · Always work with a partner. · When using the probes, keep fingers as far behind the probe tips as possible. Features: · Auto/manual ranging clamp meter · Non-Contact Voltage (70-600VAC) · Measures 400 AAC Current · Measures AC/DC Voltage and Resistance · Audible continuity · Data hold · Auto Power Off · Low Battery Indicator · Compact jaws for reaching into tight spaces · Electronic overload protection on all ranges · 61-732 model is averaging sensing, rms calibrated · 61-736 model is true rms sensing. Page 3 Features 1. Jaw Clamp 2. Lever 3. Function Dial 4. Display (LCD) 5. Volts and resistance (V-) input terminal 6. Common (COM) input terminal 7. Non-Contact Voltage (NCV) 8. Range ( ) 9. Data Hold 10. Measuring Functions Display Icons 11. 4000 count display 12. Units of measure 13. Voltage 14. Amperes 15. Ohms 16. Continuity 17. AC measurement is selected 18. DC measurement is selected 19. Polarity indicator for DC 20. Low battery indicator 21. Range ( ) 22. Data hold 23. APO - Auto Power Off 1 NCV 9 2 10 3 7 HOLD AC DC APO 8 4 KMmVA 6 5 21 17 19 18 22 HOLD 23 APO 16 AC DC 11 KMmVA 20 12 15 13 14 Symbols on the Unit · Warning - read the instruction manual · NCV - Non-Contact Voltage · Cat III - 600V Safety category Page 4 OPERATION: Non-contact voltage (NCV) With the NCV tab on the tip of the clamp close to an AC voltage, press the NCV button. The NCV LED will light and the beeper will sound. The closer the NCV tab is to AC voltage, the louder the beep. To differentiate between hot and neutral in an outlet, insert the NCV tab into each slot in the outlet. The beeper will be much louder on the hot side of the outlet than the neutral. The test lead can also be used to differentiate between the hot and neutral. Plug the red test lead into the V/ input jack on the meter. Press the NCV button and insert the probe tip into each slot of the outlet. The beeper will only beep on the hot side of the outlet. Auto/Manual Ranging Mode ( ) The meter defaults to autoranging mode when powered on. In this mode, the meter automatically selects the best range to display the measurement. By pressing the Range ( ) button on the meter, the manual range mode will override the autoranging feature of the meter. A ( ) appears in the upper left side of the display. Continue pressing the Range button until the desired range is obtained. Use this mode to lock in a specific range for repeated measurements. To return to the autoranging mode, either depress the Range button for greater than 1 second or turn the meter off and then back on again. Data Hold Feature Press the Hold button on the side of the meter to toggle in and out of the data hold mode. "HOLD" appears in the upper left of the meter display when data hold is active. Use the data hold feature to lock a measurement reading on the display. Press the Hold button again to unlock the display and obtain a real-time reading. Auto Power Off (APO) Feature The meter automatically powers itself down after about 10 minutes of no use. Press any button, and the meter will wake up and display the last reading taken before power down. This feature can be overridden by holding the Range ( ) button while turning the function switch from Off to any other position. When APO is defeated, the "APO" will be removed from the display. Turning the meter off will restore the APO default. Page 5 Measuring AC Current (Amps): H N CORRECT Single Conductor only INCORRECT Currents cancel CORRECT Use with line splitter Measuring Voltage: AC Voltage DC Voltage Page 6 Measuring Resistance (Ohms): · Verify the circuit is de-energized to obtain accurate measurements. Verifying Continuity ( ): · Verify the circuit is de-energized. · The meter will sense the level of resistance and beep if the resistance is less than 25 to confirm that continuity is present. Closed Circuit Page 7 Open Circuit Battery Replacement: · Ensure test leads are disconnected from circuit or components. · Remove test leads from input jacks on meter. · Remove the two screws from the battery cap. · Remove the battery cap. · Replace batteries with two "AAA" batteries. · Assemble the battery cap to the meter and re-tighten the screws. + + Maintenance: · Clean the case with a damp cloth and mild detergent. Do not use abrasives or solvents. Service and Replacement Parts: This unit has no user-serviceable parts. For replacement parts or to inquire about service information contact IDEAL INDUSTRIES, INC. at 1-877-201-9005 or visit our website www.testersandmeters.com. Page 8 Specifications: Display: Polarity: Overrange: Measure Rate: Auto Power Off: Battery Life: 3-3/4 digit LCD with 4000 counts Automatic, positive implied, negative (-) polarity indication. "OL" indication is displayed. Samples 2 times per second, nominal. Approximately after 10 minutes of non-use. 400 hours continuous with Alkaline (61-732) 250 hours continuous with Alkaline (61-736) Low Battery Indication: The " " is displayed when battery voltage drops below operating level. Power Supply: (2) 1.5V "AAA" batteries (NEDA R03). Includes an isolated battery compartment. Accuracy: Stated accuracy at 23°C ±5°C, <75% R.H. Temperature 0.1 x (specified accuracy) per °C, Coefficient: (0°C to 18°C, 28°C to 50°C). Altitude: 6561.7 ft. (2000m) Operating Environment: 32°F to 122°F (0°C to 50°C) at < 70% R.H. Storage Environment: -4°F to 140°F (-20°C to 60°C) at < 80% R.H. Jaw Opening: Accepts a 1.25" (32mm) conductor Dimensions: 7.4"H x2.6"W x1.5"D (187mm H x65mm W x37mm D) Weight: 6.7 oz (190g) including batteries Accessories included: Carrying Case, Test Leads, (2) 1.5V "AAA" batteries, operating instructions. Safety: Complies with EN 61010-1, EN 61010-2-032, UL 61010B-1, UL 61010B-2-032 specifications, Clamp rated to Cat III-300V. Voltage rated for Cat III-600V. + C US N12966 Double Insulation Instrument has been evaluated and complies with insulation category II (overvoltage category II). Pollution degree 2 in accordance with IEC-644. Indoor use. Page 9 Ranges & Accuracies: AC Converter: 61-732 model is averaging sensing, rms calibrated 61-736 model is true rms sensing. Accuracy: Accuracy is specified as +/-(a percentage of the reading + a fixed amount) at 23°C±5°C (73.4°F ± 9°F), less than 75% relative humidity. Temperature Coefficient: 0.1 times the applicable accuracy specification per degree C from 0°C to 18°C and 28°C to 50°C (32°F to 64°F and 82°F to 122°F) Range and Resolution 40.0A/400.0A 40.0A/400.0A 400.0V 600V Accuracy 61-732 61-736 Overload Protection 400AAC Function AC Current* (50Hz - 60Hz) 1.7% + 6 digits 1.7% + 10 digits (60Hz - 400Hz) 3.0% + 6 digits 3.0% + 10 digits (50Hz - 500Hz) 1.2% + 5 digits 1.2% + 8 digits (50Hz - 500Hz) 1.5% + 5 digits 1.5% + 8 digits AC Voltage 600 VDC or AC rms DC Voltage 400.0V/600V 400.0/4.000k/40.00k/ 400.0k Resistance 4.000M 40.00M Continuity Audible indication < 25 Response time: 500ms 0.5% + 2 digits 1.0% + 4 digits 600 VDC or AC rms 600 VDC or AC rms 1.5% + 4 digits 3.0% + 5 digits N/A 600 VDC or AC rms * Accuracy stated for crest factor 3 Input Impedance is 10M. Page 10 Warranty Statement: This tester is warranted to the original purchaser against defects in material and workmanship for the lifetime of the product. During this warranty period, IDEAL INDUSTRIES, INC. will, at its option, replace or repair the defective unit, subject to verification of the defect or malfunction. This warranty does not apply to defects resulting from abuse, neglect, accident, unauthorized repair, alteration, or unreasonable use of the instrument. Any implied warranties arising out of the sale of an IDEAL product, including but not limited to implied warranties of merchantability and fitness for a particular purpose, are limited to the above. The manufacturer shall not be liable for loss of use of the instrument or other incidental or consequential damages, expenses, or economic loss, or for any claim or claims for such damage, expenses or economic loss. State laws vary, so the above limitations or exclusions may not apply to you. This warranty gives you specific legal rights, and you may also have other rights which vary from state to state. IDEAL INDUSTRIES, INC. Sycamore, IL 60178 Technical Hotline: 877- 201-9005 www.testersandmeters.com ND 4952-1 Made in Taiwan Page 11 #61-732 #61-736 Medidor de pinza Manual de Instrucciones HOLD AC DC APO KMmVA ADVERTENCIA Lea primero: Información de seguridad Comprenda y siga estas instrucciones de operación cuidadosamente. Use el medidor sólo según se especifica en este manual; de lo contrario, la protección que él proporciona podría deteriorarse. ADVERTENCIA Para evitar una posible descarga eléctrica, lesiones personales o la muerte, siga estas instrucciones: · No utilice el medidor si se lo ve dañado. Inspeccione visualmente el medidor para asegurarse de que la caja no esté agrietada y la caja posterior esté colocada firmemente. · Inspeccione y reemplace los cables si el aislamiento está dañado, el metal está al descubierto o las sondas están agrietadas. Preste atención en particular al aislamiento que rodea los conectores. · No utilice el medidor si funciona de forma anormal, ya que la protección puede haberse dañado. · No lo utilice durante tormentas eléctricas o con tiempo húmedo. · No lo utilice cerca de gases, polvo o vapores explosivos. · No aplique al medidor un voltaje mayor que el voltaje nominal. · No lo utilice sin las baterías y sin la caja posterior bien instalada. · Quite los cables de prueba del circuito antes de quitar la tapa de las baterías. · No intente reparar esta unidad, ya que no tiene piezas reparables por el usuario. Page 2 PRECAUCIÓN Para protegerse, piense en la `Seguridad ante todo': · Los voltajes que superen 30 V CA o 60 V CC presentan un peligro de descarga, por lo que debe tener cuidado. · Utilice equipos de protección personal apropiados, como gafas de seguridad, máscaras, guantes aislantes, botas aislantes y esteras aislantes. · Antes de cada uso: - Realice una prueba de continuidad poniendo en contacto los cables de prueba entre sí, para verificar la funcionalidad de las baterías y los cables de prueba. - Use el Método de Seguridad de 3 Puntos. (1) Verifique la operación del medidor midiendo un voltaje conocido. (2) Aplique el medidor al circuito bajo prueba. (3) Pruebe nuevamente con un voltaje real conocido para asegurar un funcionamiento correcto. · Nunca se conecte a tierra cuando tome medidas eléctricas. · Conecte el cable común negro a tierra antes de aplicar el cable de prueba rojo al voltaje. Desconecte primero el cable de prueba rojo del voltaje. · Trabaje siempre con un compañero. · Al usar las sondas, mantenga los dedos lo más detrás posible de las puntas de las mismas. Características: · Medidor de pinza con selección de gama automática y manual · Indicaciones de valor eficaz (rm ...

  Know our Partners   Frequently Asked Questions   Contact Diplodocs team   Last searches
Latest additions
  Sitemap
Brands starting with A B C D E F G H I J K L M N O P Q R S T U V W X Y Z #
Copyright © 2005 - 2008 - Diplodocs - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.