Manual abstract: user guide IDEAL ND 4969-2 61-772774

Detailed instructions for use are in the User's Guide.

#61-772 #61-774 1000A Clamp Meters w/TightSightTM Display Instruction Manual CAT.IV 600V CAT.III 1000V 1000A HOLD 61-774 V V A MAX MIN A 400 1000 OFF PEAK True RMS 000VX 750V DCA CA MP S 0 10 20 30 40 COM V/ CAT.IV 600V CAT.III 1000V MAX 1000V 750V 600V TightSightTM Display Read First: Safety Information Understand and follow operating instructions carefully. Use the meter only as specified in this manual; otherwise, the protection provided by the meter may be impaired. WARNING To avoid possible electric shock, personal injury or death, follow these guidelines: · Do not use if meter appears damaged. Visually inspect the meter to ensure case is not cracked and back case is securely in place. · Inspect and replace leads if insulation is damaged, metal is exposed, or probes are cracked. Pay particular attention to the insulation surrounding the connectors. · Do not use meter if it operates abnormally as protection maybe impaired. · Do not use during electrical storms or in wet weather. · Do not use around explosive gas, dust, or vapor. · Do not apply more than the rated voltage to the meter. · Do not use without the battery and the back case properly installed. · Remove the test leads from the circuit prior to removing battery cap. · Do not attempt to repair this unit as it has no user-serviceable parts. CAUTION To protect yourself, think "Safety First": · Voltages exceeding 30VAC or 60VDC pose a shock hazard so use caution. · Use appropriate personal protective equipment such as safety glasses, face shields, insulating gloves, insulating boots, and/or insulating mats. · Before each use: - Perform a continuity test by touching the test leads together to verify the functionality of the battery and test leads. - Use the 3 Point Safety Method. (1) Verify meter operation by measuring a known voltage. (2) Apply meter to circuit under test. (3) Return to the known live voltage again to ensure proper operation. · Never ground yourself when taking electrical measurements. · Connect the black common lead to ground or neutral before applying the red test lead to potential voltage. Disconnect the red test lead from the voltage first. · Always work with a partner. · When using the probes, keep fingers as far behind the probe tips as possible. Page 2 770 Series Common Features: · Auto/manual ranging clamp meter · TightSightTM bottom display · Visual and audible indication when voltage is present even when the meter is set on the wrong function for enhanced safety · Measures 1000 AAC Current · Measures AC/DC Voltage & Resistance · Audible continuity · Bright, bold backlight · Large numbers and symbols displayed · Peak max/min, max/min, data hold · Selectable Auto power off and low battery indicator · Tapered jaws for reaching into tight spaces · Hook tip for easier wire separation · Protective rubber boot · Electronic overload protection on all ranges · Cat IV-600V/Cat III-1000V · 61-772 model is true rms sensing · 61-774 model is true rms sensing, measures DC current and capacitance Features 1. Tapered jaws w/hook tip 2. Lever 3. Function Dial 4. Main Display (LCD) 5. Volts and resistance (V-) input terminal 6. Common (COM) input terminal 7. TightSightTM bottom display 8. Protective rubber boot 9. Measuring Functions 10. High Voltage (Hi-V) warning 11. Data Hold 12. Max/min 13. Peak max/min 14. Backlight 15. Range ( ) 16. Relative mode ( ) Symbols on the Unit · Warning - read the instruction manual · Cat IV - 600V Safety category · Cat III - 1000V Safety category Page 3 1 CAT.IV 600V CAT.III 1000V 1000A 10 2 61-774 HOLD V V 11 3 9 12 13 MAX MIN A A 400 1000 14 OFF PEAK True RMS 15 16 4 0 10 20 30 40 COM V/ 6 CAT.IV 600V CAT.III 1000V MAX 1000V 750V 5 8 7 Main Display Icons 15. 4000 count display 16. AC measurement 17. DC measurement 18. Polarity indicator for DC 19. Range ( ) 20. Auto Power Off (APO) 21. Data Hold 22. Max/min 23. Peak max/min 24. Audible continuity 25. Volts 26. Amps 27. Farads 28. Ohms 29. Hertz 30. Units of measure 31. Analog bar graph 32. Low battery indicator 33. Relative ( ) Main Display 20 21 22 23 25 26 24 27 28 29 19 16 18 17 33 15 APO HOLD MAX MIN P + P AC DC mVA nmµF kM Hz 31 30 32 4 7 -7 1 6 00 01 4 O P A C A 0 0 0 M O C IV 10 T. I X A . II A C AT M 0V 0V C 00 1 75 V 0 0V 6 00 1 0 2 0 A 3 0 / V 4 0 DC A C AM PS TightSightTM Bottom Display TightSightTM Display Icons 34. 4000 count display 35. Polarity indicator for DC 36. DC measurement 37. AC measurement 38. Amps 36 37 38 34 35 DCAC AMPS Note: Only AC/DC amps units of measure are displayed in the TightSightTM display since primary use is for viewing current measurements in tight locations. The display will show numerical values only for other functions. The main display is to be used to view units of measure for all other functions. Page 4 OPERATION: High Voltage Warning (HI-V) The meter beeps and lights an LED when > 30V AC/DC voltage is present through the test leads of the meter. This enhanced safety feature alerts the user that dangerous voltage is present across the leads even if the meter is set on an incorrect function or range. Note: This features does not work through the clamp head as the clamp is intended to only measure current. Auto/Manual Ranging Mode ( ) The meter defaults to autoranging mode when powered on. In this mode, the meter automatically selects the best range to display the measurement. By pressing the Range ( ) button on the meter, the manual range mode will override the auto-ranging feature of the meter. A ( ) appears in the upper left side of the display. Continue pressing the Range button until the desired range is obtained. Use this mode to lock in a specific range for repeated measurements. To return to the autoranging mode, either depress the Range button for greater than 1 second or turn the meter off and then back on again. Peak Max/Min Feature Peak function captures peak voltage in the VAC function and peak current in the AAC function. Both P+ and P- have 1 ms capture time. Set the meter to the desired function, press the "PEAK" button and apply the setup to the circuit. The P+ will be displayed. Press the "PEAK" button again to display the P-. Depress the peak button for >2 sec. to exit the peak feature. Note: If a more accurate peak measurement is required, then calibration should be performed. Depress the Peak button for >2 sec. until "CAL" appears in the display. The meter selfcalibrates to ±3% accuracy + 60 digits accuracy (400m/4VAC ranges unspecified). Max/Min Feature The Max records the maximum vaue measured over time while Min captures the minimum value measured over time. Press the Max/Min button to activate this feature and to toggle between Max, Min and Maxmin. "MAXMIN" displays the real time reading while still capturing max and min values over time. Depressing the max/min button for >2 sec. exits the mode. Note: To record max/min values over a time period >30 min, the Auto Power Off (APO) feature must be defeated. Data Hold Feature Press the Hold button on the side of the meter to toggle in and out of the data hold mode. "HOLD" appears in the upper left of the meter display when data hold is active. Use the data hold feature to lock a measurement reading on the display. Press the Hold button again to unlock the display and obtain a real-time reading. Page 5 Relative Mode ( ) (61-774 model only) This mode is used to zero out the display before measuring DC current. Press the " "button to subtract out the non-zero number. Then, measure the DC amps. Pressing the " " button again causes the " " to flash and the original offset number to be displayed. Depress the " " button for >2 sec. to exit this mode. Selectable Auto Power Off (APO) Feature The meter automatically powers itself down after about 30 minutes of no use. Press any button, and the meter will wake up and display the last reading taken before power down. This feature can be overridden by holding the Range ( ) button while turning the function switch from Off to any other position. When APO is defeated, the "APO" will be removed from the display. Turning the meter off will restore the APO default. Backlight Press the button in the middle of the meter to turn the backlight on and off. The green backlight will remain lit for about 4.5 minutes before it automatically turns off to conserve battery power. Also, the TightSightTM bottom display only lights while the meter is in the Amp function to minimize battery drain. Note: Backlight consumes 4x the battery power. 61 -774 40 0 10 00 AP AC O 0 A CO 10 M 20 30 V/ CA CA T. IV T. III 600 V MA 1000V 100 X 750 0V V 40 Backlight on in all functions. Backlight on A function only DCAC AM PS Measuring AC Current (Amps): H CAT.IV 600V CAT.III 1000V 1000A N HOLD CAT.IV 600V CAT.III 1000V 1000A 61-774 V V HOLD 61-774 V V A MAX MIN A MAX MIN A 400 1000 OFF A 400 1000 PEAK OFF True RMS PEAK True RMS 0 10 20 30 40 COM 0 10 20 30 40 V/ COM V/ CAT.IV 600V CAT.III 1000V MAX 1000V 750V CAT.IV 600V CAT.III 1000V MAX 1000V 750V CORRECT Single Conductor only INCORRECT Currents cancel Note: 61-774 model also measures DC Current. Page 6 Measuring Voltage: CAT.IV 600V CAT.III 1000V CAT.IV 600V CAT.III 1000V 1000A 1000A HOLD HOLD 61-774 V V 61-774 V V A MAX MIN A 400 1000 OFF MAX MIN A A 400 1000 OFF PEAK PEAK True RMS True RMS 0 10 20 30 40 COM V/ 0 10 20 30 40 CAT.IV 600V CAT.III 1000V MAX 1000V 750V COM V/ CAT.IV 600V CAT.III 1000V MAX 1000V 750V AC Voltage DC Voltage Measuring Resistance (Ohms): · Verify the circuit is de-energized to obtain accurate measurements. CAT.IV 600V CAT.III 1000V 1000A HOLD 61-774 V V A MAX MIN A 400 1000 OFF PEAK True RMS 0 10 20 30 40 COM V/ CAT.IV 600V CAT.III 1000V MAX 1000V 750V Page 7 Verifying Continuity ( ): · Verify the circuit is de-energized. · The meter will sense the level of resistance and beep if the resistance is less than 35 to confirm that continuity is present. CAT.IV 600V CAT.III 1000V 1000A CAT.IV 600V CAT.III 1000V 1000A HOLD HOLD 61-774 V V 61-774 V V A MAX MIN 400 1000 A OFF MAX MIN A A 400 1000 OFF PEAK PEAK True RMS True RMS 0 10 20 30 40 0 10 20 30 40 COM V/ COM V/ CAT.IV 600V CAT.III 1000V MAX 1000V 750V CAT.IV 600V CAT.III 1000V MAX 1000V 750V Closed Circuit Open Circuit Capacitance (61-774): CAT.IV 600V CAT.III 1000V 1000A HOLD 61-774 V V A MAX MIN A 400 1000 OFF PEAK True RMS 0 10 20 30 40 COM V/ CAT.IV 600V CAT.III 1000V MAX 1000V 750V Page 8 Battery Replacement: · Ensure test leads are disconnected from circuit or components. · Remove test leads from input jacks on meter. · Remove the two screws from the battery cap. · Remove the battery cap. · Replace battery with a new 9V battery. · Assemble the battery cap to the meter and re-tighten the screws. Maintenance: Clean the case with a damp cloth and mild detergent. Do not use abrasives or solvents. Service and Replacement Parts: This unit has no user-serviceable parts. For replacement parts or to inquire about service information contact IDEAL INDUSTRIES, INC. at 1-877-201-9005 or visit our website www.testersandmeters.com. Warranty Statement: This tester is warranted to the original purchaser against defects in material and workmanship for the lifetime of the product. During this warranty period, IDEAL INDUSTRIES, INC. will, at its option, replace or repair the defective unit, subject to verification of the defect or malfunction. This warranty does not apply to defects resulting from abuse, neglect, accident, unauthorized repair, alteration, or unreasonable use of the instrument. Any implied warranties arising out of the sale of an IDEAL product, including but not limited to implied warranties of merchantability and fitness for a particular purpose, are limited to the above. The manufacturer shall not be liable for loss of use of the instrument or other incidental or consequential damages, expenses, or economic loss, or for any claim or claims for such damage, expenses or economic loss. State laws vary, so the above limitations or exclusions may not apply to you. This warranty gives you specific legal rights, and you may also have other rights which vary from state to state. Page 9 + Replacement boot is available. Specifications: Displays: Backlight: Analog Bargraph: Polarity: Overrange: Zero: Measure Rate: Auto Power Off: Battery Life: 3-3/4 digit LCD with 4000 counts for both displays Green illumination with auto-off after 4.5 minutes 41 segment LCD with measurements of 20 times per second Automatic, positive implied, negative (-) polarity indication. "OL" indication is displayed. Automatic Samples 2 times per second, nominal. Approximately after 30 minutes of non-use. 200 hours continuous with Alkaline (61-772) 150 hours continuous with Alkaline (61-774) Low Bat ...

  Know our Partners   Frequently Asked Questions   Contact Diplodocs team   Last searches
Latest additions
  Sitemap
Brands starting with A B C D E F G H I J K L M N O P Q R S T U V W X Y Z #
Copyright © 2005 - 2008 - Diplodocs - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.