9 562 brands
2 694 000 user's guides


Download your manual, it's FREE! Diplodocs allows you to download several types of document in order to best use your JANDY H05612 : user manual, user guide, instruction manual.
Search a brand
Advanced Search

User manual JANDY H05612

Diplodocs help download the user guide JANDY H05612 .

Download the complete user guide (509 Ko)





Preview of the first 3 pages of manual

You either have JavaScript turned off or an old version of Adobe Flash Player
Get the latest Flash Player.
Manual abstract: user guide JANDY H05612

Detailed instructions for use are in the User's Guide.

Installation and Operation Data Installation and Operation Manual JandyColors Digital Color Blending, Underwater Pool and Spa Lights ® WARNING H0561200C FOR YOUR SAFETY - This product must be installed and serviced by a professional pool/ spa service technician. The procedures in this manual must be followed exactly. Failure to follow warning notices and instructions may result in property damage, serious injury, or death. Page 3 Table of Contents Section 1. Safety Information ................................................................................................................... Section 2. Product Description and Model Numbers ............................................................................... Section 3. Installing Jandy Light Fixture during New Construction ........................................................ 3.1 3.2 4 5 6 Preparing the Light Fixture for Installation ....................................................................... 6 Installing the Light Fixture ................................................................................................ 7 9 Section 4. Replacing Jandy Light Fixture in an Existing Pool or Spa ..................................................... 4.1 4.2 Preparing the Light Fixture for Replacement .................................................................... 9 Replacing the Light Fixture ............................................................................................... 9 11 Section 5. Wiring Options for Controlling Jandy Pool Lights or Jandy Spa Lights ................................. 5.1 5.2 Wiring to an AquaLink® RS Control System .................................................................... 11 Wiring to a Time Clock ..................................................................................................... 12 13 Section 6. Jandy Pool Light and Jandy Spa Light Operating Instructions................................................ 6.1 6.2 6.3 To Operate the Light .......................................................................................................... 13 To Lock On a Specific Color Set ....................................................................................... 13 To Initiate a New Cycle or Reset from a Locked Color..................................................... 13 14 17 18 18 19 Section 7. Replacing Bulbs ....................................................................................................................... Section 8. Twelve (12) Volt Installation ................................................................................................... Section 9. Exploded View and Replacement Parts ................................................................................... 9.1 9.2 Jandy Digital Pool Light ................................................................................................... Jandy Digital Spa Light ..................................................................................................... Page 4 Section 1. Safety Information IMPORTANT SAFETY INSTRUCTIONS PERTAINING TO A RISK OF FIRE, ELECTRIC SHOCK, OR INJURY TO PERSONS READ AND FOLLOW ALL INSTRUCTIONS When installing and using this electrical equipment, basic safety precautions should always be followed, including the following: WARNING RISK OF ELECTRICAL SHOCK OR ELECTROCUTION. This underwater light must be installed by a licensed or certified electrician in accordance with the National Electrical Code and applicable local codes and ordinances. Improper installation will create an electrical hazard, which could result in death or serious injury to pool or spa users, installers, or others due to electrical shock, and may also cause damage to property. Read and follow the specific instructions below. WARNING Before installing this underwater light, read and follow all warning notices and instructions accompanying this light. Failure to follow safety warnings and instructions can result in severe injury, death, or property damage. Call (707) 776-8200 for additional free copies of these instructions. ATTENTION INSTALLER: This manual contains important information about the installation, operation and safe use of this product. This information should be given to the owner/operator of this equipment. NOTICE These lights are intended for installation in fresh water swimming pools and spas only. SAVE THESE INSTRUCTIONS Page 5 Section 2. Product Description and Model Numbers Product Jandy Pool Light Jandy Pool Light Jandy Pool Light Jandy Pool Light Jandy Pool Light Jandy Pool Light Jandy Pool Light Jandy Spa Light Jandy Spa Light Jandy Spa Light Jandy Spa Light Jandy Spa Light Jandy Spa Light Jandy Spa Light Voltage 12 Volt AC 12 Volt AC 12 Volt AC 120 Volt AC 120 Volt AC 120 Volt AC 120 Volt AC 12 Volt AC 12 Volt AC 12 Volt AC 120 Volt AC 120 Volt AC 120 Volt AC 120 Volt AC Cord Length 30 feet 50 feet 100 feet 30 feet 50 feet 100 feet 150 feet 30 feet 50 feet 100 feet 30 feet 50 feet 100 feet 150 feet Model # JPL1230 JPL1250 JPL12100 JPL12030 JPL12050 JPL120100 JPL120150 JSL1230 JSL1250 JSL 12100 JSL12030 JSL12050 JSL120100 JSL120150 Page 6 Section 3. Installing Jandy Light Fixture during New Construction 3.1 Preparing the Light Fixture for Installation NOTE The electrician must complete preparatory steps before light fixture is installed; see Figure 1 (or Figure 2, for spa). 1. Ensure that the pool or spa meets the requirements of the current National Electrical Code and all local codes and ordinances. A licensed or certified electrician must install the electrical system to meet or exceed those requirements before the underwater light is installed. Some of the requirements of the National Electrical Code, which the pool or spa's electrical systems must meet, are as follows: a. The lighting circuit must have a Ground Fault Circuit Interrupter (GFCI) for line voltage 120 volt models, and must have an appropriately rated circuit breaker. b. The Junction Box (or, for 12 volt models, the low voltage transformer) must be located at least eight (8) inches above water level, at least four (4) inches above ground level, and at least four (4) feet from the edge of the pool or spa; see Figure 1 for pools and Figure 2 for spas. c. The light fixture and all metal items within five (5) feet of the pool or spa must be properly electrically bonded to a reliable point of grounding. d. The wet niche must be properly installed so that the top edge of the underwater light's lens is at least 18 inches below the surface of the water in the pool or spa; see Figure 1 or 2. (Not more than 48 inch depth in Canada.) e. The wet niche must be properly electrically bonded and grounded via the No. 8 AWG ground connector located at the rear of the niche; see Figure 1 or 2. NOTE The pool or spa electrical system can be verified with a Pool and Spa Electrical Qualification Test kit. The test kit is available from local distribution. The electrical system inspection using this kit must be performed by trained and certified personnel. To GFCI, Circuit Breaker and Power Source. 48" min. 4" min. 8" min. Junction Box or Low Voltage Transformer, maximum water level of the pool. 18" min. to top of Lens. Rigid Conduit #8 AWG Ground Connector bonding is located at rear of Niche. Concrete must be cut back around Niche to allow for a compacted plaster seal. 11.50" Coil 4 ft. of light cable around Fixture. 16" Figure 1. Jandy Digital Pool Light Page 7 48" min. To GFCI, Circuit Breaker and Power Source. 4" min. 8" min. Junction Box or Low Voltage Transformer. Rigid Conduit #8 AWG Ground Connector bonded to rebar. 18" min. to top of Lens. 6.0" Concrete must be cut back around Niche to allow for a compacted plaster seal. Coil 4 ft. of light cable around Fixture. Figure 2. Jandy Digital Spa Light 2. 3. To be certain that the pool or spa's electrical system meets all applicable requirements, the electrician should also consult the local building department. Use only approved wet niches (see following note) to ensure a safe and proper installation. NOTE Jandy Pool and Spa Lights are ETL listed (ETL report/file 3033587.001) for installation with only the following manufacturer's wet niche fixtures: Large / Pool Type Niche Model Numbers: Pentair: 7821XXXX, 7822XXXX, 7823XXXX, 792067XX, 792089XX Hayward DuraNiche: SP0600U Sta-Rite: 05161-XXXX, 05163-XXXX Small / Spa Type Niche Model Numbers: Pentair: 7824XXXX, 792066XX Hayward DuraNiche: SP0601U Sta-Rite: 05166-XXXX, 05167-XXXX 3.2 Installing the Light Fixture NOTE Perform these steps only after the electrical system requirements are met. 1. Feed cord through conduit to Junction Box, leaving at least four (4) feet of cord at the light fixture to coil around the light; see Figure 1 (or Figure 2, for spa). This four (4) feet of cord around the light allows the light to be serviced after the pool or spa is filled with water. Cut the cord at the Junction Box, leaving at least six (6) inches of cord to make connections. Strip six (6) inches of the outer cord jacket to expose the three insulated wires. Be careful not to damage the insulation on the three (3) inner wires. Install strain relief over cord jacket and connect all three (3) wires to the corresponding circuit wires in the Junction Box. Install the Junction Box cover. WARNING Never operate this underwater light for more than 10 seconds unless it is totally submerged in water. Without total submersion, the light assembly will get extremely hot, which may result in serious burns or in breakage of the bulb or lens. This may result in serious injury to pool or spa users, installers, or bystanders or in damage to property. 2. 3. 4. Page 8 5. 6. Coil the 4-foot length of cord around the fixture and place the light assembly into the niche. Engage the retainer tab on the bottom of the face ring, then pivot the top of the fixture inward and tighten the special pilot screw. WARNING Use only the special pilot screw provided with this underwater light. This screw mounts and electrically grounds the housing securely to the mounting ring and wet niche. Failure to use the screw provided could create an electrical hazard, which could result in death or serious injury to pool or spa users, installers or others due to electrical shock. 7. Fill the pool or spa until the underwater light is completely submerged in water before operating the light for more than 10 seconds. Turn on main switch or circuit breaker, and the switch, which operates the underwater light, to check for proper operation. Refer to Section 6, Operating Instructions. Page 9 Section 4. Replacing Jandy Light Fixture in an Existing Pool or Spa WARNING Risk of Electrical Shock or Electrocution. This underwater light must be installed by a licensed or certified electrician or a qualified pool or spa serviceman in accordance with the National Electrical Code and all applicable local codes and ordinances. Improper installation will create an electrical hazard, which could result in death or serious injury to pool or spa users, installers or others due to electrical shock, and may also cause damage to property. Always disconnect the power to the pool or spa light at the circuit breaker before servicing the light. Failure to do so could result in death or serious injury to serviceman, pool or spa users or others due to electrical shock. 4.1 Preparing the Light Fixture for Replacement 1. Verify that the pool or spa meets the requirements of the current National Electrical Code and all local codes and ordinances. A licensed or certified electrician must install the electrical system to meet or exceed those requirements before the underwater light is installed. Some of the requirements of the National Electrical Code, which the pool or spa's electrical system must meet, are as follows: a. The lighting circuit must have a Ground Fault Circuit Interrupter (GFCI) for line voltage 120 volt models, and must have an appropriately rated circuit breaker. b. The Junction Box (or, for 12 volt models, the low voltage transformer) must be located at least 8 inches above ground or water level, at least four (4) inches above ground level, and at least 48 inches from the edge of the pool or spa; see Figure 1 (or Figure 2, for spa). c. The light fixture and all metal items within 5 feet of the pool or spa must be properly electrically bonded to a reliable point of grounding. d. The wet niche must be properly installed so that the top edge of the underwater light's lens is at least 18 inches below the surface of the water in the pool or spa; see Figure 1 (or Figure 2, for spa). e. The wet niche must be properly electrically bonded and grounded via the No. 8 AWG ground connector located at the rear of the niche; see Figure 1 (or Figure 2, for spa). NOTE The pool or spa electrical system can be verified with a Pool and Spa Electrical Qualification Test Kit. The test kit is av ...

  Know our Partners   Frequently Asked Questions   Contact Diplodocs team   Last searches
Latest additions
  Sitemap
Brands starting with A B C D E F G H I J K L M N O P Q R S T U V W X Y Z #
Copyright © 2005 - 2008 - Diplodocs - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.