9 562 brands
2 694 000 user's guides


Download your manual, it's FREE! Diplodocs allows you to download several types of document in order to best use your KB ELECTRONICS KBCC-SERIES : user manual, user guide, instruction manual.
Search a brand
Advanced Search

User manual KB ELECTRONICS KBCC-SERIES

Diplodocs help download the user guide KB ELECTRONICS KBCC-SERIES .

Download the complete user guide (2016 Ko)





Preview of the first 3 pages of manual

You either have JavaScript turned off or an old version of Adobe Flash Player
Get the latest Flash Player.
Manual abstract: user guide KB ELECTRONICS KBCC-SERIES

Detailed instructions for use are in the User's Guide.

KBPB & KBCC-R SUPPLEMENTAL INFORMATION DESCRIPTION The Anti-Plug Reversing Module used in the KBPB and KBCC-R models has been changed from APRM-2C to APRM-3. The General Performance Specifications of these products have not changed. This supplement is being supplied with the KBPB and KBCC-R Installation and Operation Manuals (Part Nos. A40210A and A40225A) until the new manuals are available. The figures below replace the figures in the KBPB and KBCC-R Installation and Operation Manuals. For further assistance, contact our Sales Department toll free, at 800-221-6570. Read Safety Warning SAFETY WARNING! This drive contains electronic Start/Stop circuits which can be used to start and stop the drive. However, these circuits are never to be used as safety disconnects since they are not failsafe. Use only the AC line for this purpose. Be sure to follow all instructions carefully. Fire and/or electrocution can result due to improper use of this product. Power Main Speed Potentiometer Forward-Brake-Reverse Switch TB1 P1 P2 P3 S1 S2 S3 S4 + ARMATURE P1 P2 P3 S1 S2 S3 S4 A1 TB1 FWD-BRK-REV SWITCH REV BRK FWD HIGH WIPER LOW MAIN SPEED POTENTIOMETER Forward-Brake-Reverse and Run-Brake-Jog Switches with Main Speed Potentiometer P1 P2 P3 S1 S2 S3 S4 TB1 FWD-BRK-REV SWITCH REV BRK FWD HIGH WIPER LOW MAIN SPEED POTENTIOMETER JOG BRK RUN RUN-BRK-JOG SWITCH FWD BRK REV FWD-BRK-REV SWITCH L2 A2 AC LINE INPUT L1 CHASSIS TB3 GROUND (EARTH) Run-Brake and Forward-Reverse Switches Forward-Brake-Reverse Switch with Adjustable Forward and Preset Reverse Speed TB1 P1 P2 P3 S1 S2 S3 S4 FWD-REV SWITCH REV RUN-BRAKE SWITCH FWD P1 P2 P3 S1 S2 S3 S4 TB1 HIGH WIPER LOW MAIN SPEED POTENTIOMETER Forward-Brake-Reverse and Run-Brake-Jog Switches with Main Speed Potentiometer and Remote Jog Potentiometer TB1 Tach-Generator Feedback Connections 50 Volts per 1000 RPM Tach-Generator 7 Volts per 1000 RPM Tach-Generator P1 P2 P3 S1 S2 S3 S4 FWD-BRK-REV SWITCH REV RUN-BRK-JOG SWITCH BRK FWD RUN HIGH WIPER LOW MAIN SPEED POTENTIOMETER BRK JOG "B" TERMINAL (ON KBMM) "T" TERMINAL (ON KBMM) TB2 F+ F- TB2 F+ F- + TACH-GENERATOR + TACH-GENERATOR REMOTE JOG POTENTIOMETER KB ELECTRONICS, INC. 12095 NW 39th Street, Coral Springs, FL 33065-2516 · (954) 346-4900 · FAX (954) 346-3377 Outside Florida Call Toll Free (800) 221-6570 · info@kbelectronics.com www.kbelectronics.com (A40150) ­ Rev. C ­ 7/2006 Print Code KBPB & KBCC-R SUPPLEMENTAL INFORMATION The latest versions (11/2000) of the KBPB and KBCC-R controls do not contain Inhibit terminals on the terminal block. The Inhibit feature is available, however, by wiring a switch or contact to the I1 and I2 QD terminals on the PC board. The control uses the S2 terminal for brake-to-stop operation (open to stop, close to run). If the application requires coast-to-stop operation, connect the Inhibit Switch as shown below. I2 P1 P3 P2 I1 T B F+ A+ L2 L1 Do not route the Inhibit wires with AC line or motor wires unless shielded cables are used. One side of the Inhibit Switch connects to the new piggyback I1 QD Terminal. The other side of the Inhibit Switch connects to the I2 QD Terminal (or the Fterminal on Terminal Block TB2). It is recommended that the Inhibit Switch wires be routed (and secured with wire ties) with other signal wires (S1, S2, S3, etc.). AInhibit Switch (Close to Coast-to-Stop) (Open to Run) F- MOUNTING INSTRUCTION FOR CHASSIS & IP-20 CONTROLS Note: KBPB shown. The KBCC-R uses the same PC board. SAFETY WARNING! This drive contains electronic Start/Stop circuits which can be used to start and stop the drive. However, these circuits are never to be used as safety disconnects since they are not fail-safe. Use only the AC line for this purpose. Be sure to follow all instructions carefully. Fire and/or electrocution can result due to improper use of this product. WARNING! This control must be mounted in an enclosure. Care should be taken to avoid extreme hazardous locations where physical damage to the control can occur due to moisture, metal chips, dust, and other contamination including corrosive atmosphere. If such contamination is present, special enclosures may be required such as NEMA type 4X. Failure to observe these instructions could cause an electrical shock, fire, or explosion in this product or the products used with this product. Do not use this control in an explosion-proof application. You must read the Safety Warning which accompanies this product. KB ELECTRONICS, INC. (A40150) ­ Rev. C ­ 7/2006 Print Code 12095 NW 39th Street, Coral Springs, FL 33065-2516 · (954) 346-4900 · FAX (954) 346-3377 Outside Florida Call Toll Free (800) 221-6570 · info@kbelectronics.com www.kbelectronics.com ...

  Know our Partners   Frequently Asked Questions   Contact Diplodocs team   Last searches
Latest additions
  Sitemap
Brands starting with A B C D E F G H I J K L M N O P Q R S T U V W X Y Z #
Copyright © 2005 - 2008 - Diplodocs - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.