9 562 brands
2 694 000 user's guides


Download your manual, it's FREE! Diplodocs allows you to download several types of document in order to best use your KEYENCE CZ : user manual, user guide, instruction manual.
Search a brand
Advanced Search

Need help using a product?
Look at the reviews on KEYENCE CZ

User manual KEYENCE CZ

Diplodocs help download the user guide KEYENCE CZ .

Download the complete user guide (383 Ko)





Preview of the first 3 pages of manual

You either have JavaScript turned off or an old version of Adobe Flash Player
Get the latest Flash Player.
Manual abstract: user guide KEYENCE CZ

Detailed instructions for use are in the User's Guide.

142-001 SAFETY PRECAUTIONS This manual describes the instructions, operating procedures and precautions for using the CZ Series. Before beginning operation, please read this manual carefully to get the most from your CZ Series. Keep this manual handy for future reference. WARNING RGB Digital Fiberoptic Sensors CZ Series Instruction Manual · The CZ Series is intended for the detection of target objects. Do not use the CZ Series in a safety circuit to protect the human body. · The CZ Series does not have an explosion-proof structure. Do not use it in a location where any flammable gases, liquid or powder exist. ACCESSORIES Instruction manual (This manual): 1 Mounting bracket: 1 Quick reference: 1 * Attach this sticker close to the CZ-V1 unit. CZ-V1 Quick Reference Button Names DIP switch 1234 ON [In C/C+I mode] [ : Briefly press the button.] Resin driver: 1 UP/DOWN button Mode button M [Fine sensitivity [Calling adjustment] preset value] MODE CH SET Display Switching Matching rate display CH Using button M Preset value display M CH Fine sensitivity adjustment Press CH CH SET button S [Sensitivity setting] Using button Precise Press Rough Sensitivity Setting S Error display CH · 1-point calibration (DIP switch 3: OFF) With a target in place, With a target in place, Received light intensity is too low. Received light intensity is too high. S S S . CH · 2-point calibration (DIP switch 3: ON) , and . with the target removed, * In I mode, button operation is the same as that of the FS-V1. SPECIFICATIONS Amplifier Model Light source Response time Indicators Error indication CZ-V1 Red LED, Green LED, Blue LED 300 µs/1 ms (switch selectable) Output: Red LED, Calibration: Orange LED, External synchronization input: Green LED, Matching rate/received light intensity: LCD (Red/Green) Excess light intensity, insufficient light intensity, insufficient color difference 1-point/2-point calibration (switch selectable) Fiber unit Detection method Model Type Detection range Smallest spot diameter Minimum bend radius Enclosure rating Ambient temperature Relative humidity Fiber length Housing material Weight CZ-40 Long detecting distance 70±20 mm 6 mm dia. R25 mm IP-67 -40 to +70°C 35 to 85% 2 m (free-cut) Polyarylate Approx. 27 g Reflective CZ-41 Small beam spot 16±4 mm 1 mm dia. R15 mm Calibration method Tolerance value Numerical value setting on digital display adjustment Differentiation mode C mode/C + I mode/I mode (switch selectable) Timer function Timer OFF/OFF-delay timer (40 ms) (switch selectable) Match output: Turns on when target color Output mode matches registered color. selection Mismatch output: Turns on when target color is different from registered color. (switch selectable) External synchroNon-voltage input, Response speed: 500 µs max. nization input External calibration Non-voltage input, Input response time: 20 ms min. input Registered color 8-bank selection (By external input or key operation), selection Non-voltage input, Input response time: 20 ms min. NPN open-collector: 40 VDC max. (100 mA max.), Control output Residual voltage: 1.0 V max. Reverse-polarity protection (power supply), Protection circuit overcurrent protection (output), surge absorber (output) Power supply 12 to 24 VDC±10%, Ripple (P-P): 10% max. Current 75 mA max. consumption Incandescent lamp: 5,000 lux max., Ambient light Sunlight: 10,000 lux max. Ambient -10 to +55°C 1. temperature Relative humidity 35 to 85% 10 to 55 Hz, 1.5 mm double amplitude in X, Y, and Z Vibration directions, 2 hours respectively Shock 500 m/s2 in X, Y, and Z directions, 3 times respectively Housing material Polycarbonate Weight (including Approx. 115 g 2 m cable) 1 1. When several units are connected, the acceptable ambient temperature varies depending on the conditions given below. To connect several units, be sure to mount them to a DIN rail (metallic plate). Ensure that the output current is 20 mA max. · When 3 to 10 units are connected: -10 to +50°C · When 11 to 16 units are connected: -10 to +45°C CONNECTING FIBER UNIT AND AMPLIFIER 1. Tilt the quick-release lever. 2. Push the single-core fiber to the transmitter side, and the multiplecore fiber to the receiver side as far as they will go (Approx. 14 mm of the fiber will be inserted.). * Inserting the fiber in the wrong side will decrease the original detection performance. Be sure to check the markings on the amplifier's lateral side before inserting the fiber. 3. Raise the quick-release lever. DETACHING EXPANSION UNITS FROM DIN RAIL 1. Detach the end units. 2. Slide the expansion unit that is to be detached. Detach it individually from the DIN rail. Note 1: When connecting several amplifiers, be sure to use a DIN rail and the end units. Note 2: Be sure to turn the power off before connecting/disconnecting amplifiers. Note 3: Do not remove the protective cover on the expansion connector from the outermost unit. Note 4: Do not detach several units from the DIN rail while they are connected to each other. Note 5: When several units are connected, confirm that the ambient temperature is appropriate. (See "Specifications" on page 1.) 13 Quick-release lever Single-core fiber (with markings) Transmitter side (with markings) MOUNTING FIBER UNIT · Use the supplied special mounting bracket to mount the fiber unit in the desired position according to the location. · Be sure to limit the tightening torque to 0.3 Nm or less. 2 Multiple-core fiber Receiver side Multiple-core Single-core (Transmitter side) (Receiver side) Mounting example 1 Mounting example 2 MOUNTING AMPLIFIER s Mounting/detaching amplifier to/from DIN rail or mounting bracket Hook the claw on the rear side of the amplifier onto the DIN rail or the mounting bracket, and then hook the front side claw to the rail or bracket while pressing the amplifier forward. To detach the amplifier, unhook the front claw by lifting the amplifier front side while pressing it forward. Mounting Detaching Reference: To cut the fiber to the desired length, use the special cutter included with the fiber unit. INPUT/OUTPUT CIRCUIT Connections s Side mounting Using the side holes of the supplied mounting bracket, secure the amplifier with the screws. Brown Black Pink Purple Orange/purple 100 mA max. Load 12 to 24 VDC 5 to 40 VDC External calibration External synchronization input External bank selection 1 External bank selection 2 External bankselection 3 0V CONNECTING SEVERAL AMPLIFIERS s Mounting expansion units Up to 16 expansion units (FS-T2, FS-M2, FS-V12, PS-T2) can be mounted to the side of the CZ-V1 amplifier. 1. Remove the protective cover on the side of the amplifier. 2. Mount expansion units to the DIN rail one at a time. Remove the protective cover. Yellow/purple Green/purple Blue Output circuit Photoelectric sensor main circuit Brown 12 to 24 VDC Black 5 to 40 Load 100 mA max. VDC Blue 3. Slide one expansion unit toward the main unit or another unit. Align the front claws of the units and push them together until you hear a click. 4. Secure the units together by pushing the end units (included in the expansion unit) from both sides. Align the claw. End unit (included with the expansion unit) Overcurrent protection 0V Input circuit External calibration input External synchronization input External bank selection input 1 to 3 +5 V Photoelectric sensor main circuit Main unit Expansion units -5 V Up to 16 expansion units can be connected. Pink Purple Orange/purple Yellow/purple Green/purple PLC, etc. 0V Blue The sticker on the right is included with the expansion unit. Attach the sticker close to the sensor units. 2 Short-circuit current: Approx. 1 mA PART NAMES DIP switches for mode setting HSPD 2-P C+I I FINE High-speed/High-precision 1-P C 2-point/1-point calibration Differentiation mode selection UP/DOWN key · Changes sensitivity setting value. · Changes channels. LCD display monitor 4 MODE CH OUT TIM SET SET MODE selection button · Changes display. · Shows matching rate. · Shows setting value. SET button Sets sensitivity. Output selection switch Switches between N.O. and N.C. Calibration indicator Output indicator DLY. OFF N.C N.O External synchronization input indicator Timer selection switch Switches between Timer OFF and 40 ms OFF-delay. SETTING EACH MODE DIP switch 1234 MODE 1 2 3 s FINE/HSPD selection (Using DIP switch 4) Use HSPD when the detection requires a response speed less than 1 ms. Mode FINE (Fain) HSPD (High-speed) Switch 4 4 CH OUT TIM SET SET DLY. OFF N.C N.O Timer selection switch Output selection switch Description Differentiates colors with high precision. Differentiates colors with a high-speed response of 300 µs. Factory setting "" indicates the factory-set mode. Normally, you should use the CZV1 with the setting indicated by "", and only change the setting if required. s N.O./N.C. selection Change the setting to invert the output mode. Mode Switch N.O. N.O. (Color match N.C. output) N.C. (Color N.O. N.C. mismatch output) Description Output is turned on when the target color matches the registered color. Output is turned on when the target color does not match the registered color. s Differentiation mode setting (Using DIP switches 1 and 2) Change the setting according to the detection conditions such as the target color or received light intensity. Mode Switch 12 C (Color) C+I (Color and intensity) I (Intensity) or Description Detects color using color components (R, G, and B). Detects color using color components (R, G, and B) and received light intensity (received light quantity). Detects color using received light intensity (received light quantity). s Timer OFF/40 ms OFF-delay selection Change the setting to delay the output timing. Mode Switch DLY. DLY. 12 12 Description Timer OFF 40 ms OFF-delay OFF Output is turned on without any delay. OFF Output is delayed for 40 ms. Sensitivity setting in C or C + I mode © Go to page 4. Sensitivity setting in I mode © Go to page 5. s 1-point/2-point calibration selection1. (Using DIP switch 3) Change the calibration method. Mode Switch 3 12 3 1-P (1-point calibration) 2-P (2-point calibration) Description Detects one specified color. (The sensitivity is automatically set to detect only the one color selected during calibration.) Differentiates two specified colors. (The sensitivity is automatically set to the optimal value to differentiate the two colors selected during calibration.) 1. The setting of DIP switch 3 is effective only in the C and C + I modes. The setting is unnecessary in I mode. 3 OPERATING PROCEDURE FOR USING C OR C + I MODE Setting sensitivity s 1-point calibration (Detection of one specified color) Place a target that is the reference color in the detection area of the fiber unit. Press the SET button and then release it. The calibration indicator illuminates momentarily and the reference color is saved. MODE q When calibration/differentiation fails Check the following points. · Check whether the fiber unit is mounted properly (detection distance and detection angle). (See page 7.) · Perform the sensitivity adjustment. (See below.) · Select the other differentiation mode and then perform calibration again. (See page 3.) LCD display indication Current value q Matching rate display (Matching rate display) Displays the matching degree (matching rate) of CH Channel the color of the currently Indicates the channel of detected target to the the amplifier currently v reference color registered being monitored. during calibration. Mode "C" indicates that the current mode is C or C + I. Nothing appears while in I mode. * Displays a value between 0 and 999. (Higher value indicates a better match.) MODE CH OUT TIM SET SET DLY. OFF N.C N.O Calibration indicator Press this button once. q To ignore certain color differences There are two methods for ignoring color differences. · Perform the sensitivity adjustment after calibration. (© See the lower right part of page 4.) · Use the quick color difference cancellation function. In 1-point calibration, hold down the SET button and continue the calibration with targets of different colors. The CZ Series ignores the color variation and saves them as the reference color. MODE Press the button once. Setting value CH CH OUT TIM SET SET DLY. OFF N.C N.O The setting value flashes on and off. Hold down the SET button. Calibration indicator (Illuminates while the SET button is held down.) When "nnn or "VVV is displayed nnn" VVV" nnn VVV These displays indicate that the received light is insufficient or excessive. © See page 7. s 2-point calibration (Differentiation of two colors) 1. Place a target that is the reference color in the detection area of the fiber unit. Press the SET button and then release it. The calibration indicator illuminates and the reference color is saved. 4 Sensitivity adjustment The tolerance of the detect ...

  Know our Partners   Frequently Asked Questions   Contact Diplodocs team   Last searches
Latest additions
  Sitemap
Brands starting with A B C D E F G H I J K L M N O P Q R S T U V W X Y Z #
Copyright © 2005 - 2008 - Diplodocs - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.