User manual KUSSMAUL 091-141

Diplodocs help download the user guide KUSSMAUL 091-141 .

Download the complete user guide (53 Ko)





Preview of the first 3 pages of manual

You either have JavaScript turned off or an old version of Adobe Flash Player
Get the latest Flash Player.
Manual abstract: user guide KUSSMAUL 091-141

Detailed instructions for use are in the User's Guide.

FILE: IM_091-141_Rev_B DATE: 10-02-03 INSTRUCTION MANUAL LOAD MANAGER P A battery protector for vehicles with equipment that Is operated with the engine not running MODEL# 091-141 INPUT: 12 Volts D.C. MODEL# 091-141-24 INPUT: 24 Volts D.C. 3 YEAR WARRANTY INTRODUCTION The model 091-141 LOAD MANAGER P is designed to disconnect loads when the battery voltage drops below a certain threshold. In addition a "Shutdown Timer" is provided so that the load is disconnected 1 to 2 hours after the engine is shutdown. This provides the ideal control for the computer or radio in police cars, rescue vehicles, command vehicles or any application where these devices might be used with the engine not running. If the operator forgets to shut down the computer or radio, the battery is protected, as the Load Manager P will turn off the power before the battery is drained. 12VDC Operation: The factory pre-set voltage for shutdown is 11.0 volts, but can be potentiometer adjusted up to 12.85 volts. The factory pre-set shutdown time is 1 hour (when engine is not running). This time can also be potentiometer adjusted up to 2 hours. 24VDC Operation: The factory pre-set voltage for shutdown is 22.0 volts, but can be potentiometer adjusted from 21.25 to 24.75 volts. The factory pre-set shutdown time is 1 hour (when engine is not running). This time can also be potentiometer adjusted up to 2 hours. Shutdown Timer: Enabled (factory default) when diode CR4 is installed on Printed Circuit Board Assembly (refer to Figure 3). Disabling the Shutdown Timer by removing CR4 will allow load power supply regardless of engine running/not running status. The load will, however, still be managed as a function of vehicle battery voltage per voltage shutdown described above. The Load Manager Model Number will be followed by "DIS" if the Shutdown Timer is disabled at the factory per customer order. PRINCIPLES OF OPERATION The Load Manager P is basically a low voltage disconnect which removes power from the load when the voltage sensed drops below the preset threshold of 11.0 volts for 12VDC operation and 22.0 volts for 24VDC operation. A starter override is provided to prevent disabling the load while the engine is cranking. This eliminates re-booting the computer if cranking the engine drops the battery voltage below the threshold. When the device detects that the engine is not running a timer is started. After the set time has elapsed the load will be deenergized. If during the timing cycle, the battery voltage drops below its set point, the load will be immediately deenergized. Starting the engine at any time during the timing cycle will reset the timer. A block diagram appears in figure 1. FACTORY ADJUSTED TO 1 HOUR TIME PRE-SET ADJUST TRIMMER TRUE IF T > T Sp AND ENGINE IS "OFF" ENGINE OFF SENSOR TIMER 1 HOUR TO 2 HOURS STARTER SWITCH "ON" TRUE WHILE ENGINE IS "CRANKING" VOLTAGE PRE-SET ADJUST TRIMMER POWER RELAY IF THIS LINE IS TRUE, THEN THE POWER RELAY IS ENERGIZED VBat VOLTAGE DETECTOR TRUE IF V < VSp Bat Figure 1 BLOCK DIAGRAM, LOAD MANAGER P INSTALLATION WIRING: Figure 2 illustrates the wiring of the Load Manager P. Wire the unit using the wire gauges shown in figure 2. #12 AWG, ORANGE NO RADIO & COMPUTER + LOADS #12 AWG, RED C - #12 AWG, BLACK SIZE FUSE FOR 25% HIGHER THAN ACTUAL LOAD 1 2 3 4 FROM 12 or 24 VOLT BATTERY #20 AWG, RED #20 AWG, BLACK FROM STARTER SWITCH (0PTIONAL) #20 AWG, YELLOW Figure 2 INSTALLATION WIRING, LOAD MANAGER P ALIGNMENT: Refer to Figure 3 for all component locations and measurement points. 12VDC Operation: R102 is normally set maximum counter-clockwise for an 11.0 volt threshold. R102 can be adjusted in a clockwise direction to obtain a higher threshold voltage. Maximum clockwise is 12.85 volts. 24VDC Operation: R102 is normally set approximately 70% of full counter-clockwise for a 22.0 volt threshold. R102 can be adjusted in a clockwise direction to obtain a higher threshold voltage. Maximum clockwise is 24.75 volts, maximum counterclockwise is 21.25VDC. R103 is normally set maximum counter-clockwise for a 1-hour time threshold. R103 can be adjusted in a clockwise direction to obtain a longer time threshold. Maximum clockwise is 2 hours. VOLTAGE ADJUST, R102, 24VDC MAX CCW = 21.25 VOLTS MAX CW = 24.75 VOLTS 70% MAX CCW = 22.0 VOLTS (NORMAL) VOLTAGE ADJUST, R102, 12VDC MAX CCW = 11 VOLTS (NORMAL) MAX CW = 12.85 VOLTS C2 + + CR4 A1 Q1 A2 R101 R103 C11 U3 R7 C10 + R4 C3 U1 C1 A3 R3 Shutdown Timer Enable Diode TIME ADJUSTMENT R103 MAX. CCW = 1 HOUR (NORMAL) MAX. CW = 2 HOURS + R102 VOLTS R5 R1 R8 U2 + C8 V REF CR1 R2 C9 R9 RUN TIME C13 B091-141-001 C5 C6 S1 A4 C12 R6 R12 R10 CR2 KUSSMAUL ELECTRONICS J1 CR3 C7 + + + TEST R11 Q2 + K1 + Figure 3 ALIGNMENT & PROGRAMMING, LOAD MANAGER P SPECIFICATION AND OUTLINE Temperature Environment: Main Input Power: Input Current: 0 to 50 deg C. 12VDC Battery, [24VDC Battery] 90 [40] milliamperes, relay ON 9 [5] milliamperes, relay OFF 12VDC @ 30 amperes maximum. [14VDC @ 30 Amperes maximum] Load Output Power: Low Voltage Dropout of Load: 11.0 to 12.85 volts (potentiometer adjustable, Factory set for 11 volts). [21.25 to 24.75 volts (potentiometer adjustable, Factory set for 22.0 volts)] Load Power Restoration Voltage: .5 [.75] volt higher than the Low Voltage dropout of load. Time Dropout of Load: 1 to 2 hours (potentiometer adjustable, factory set for 1 hour). The Load will not drop out due to low voltage while the engine is being started. 0.5 lbs 5.10 3/16" DIA. Starter Inhibit: Weight: 2.95 4,50 1.55 OUTLINE, LOAD MANAGER P INSTALLATION RECORD & WARRANTY Date Installed________________________________________ Installed By___________________________________________ Vehicle Identification_________________________________ Vehicle Owner________________________________________ WARRANTY All products of Kussmaul Electronics Company Inc. are warranted to be free of defects of material or workmanship. Liability is limited to repairing or replacing at our factory, without charge, any material or defects that become apparent in normal use within 3 years from the date the equipment was shipped. Equipment is to be returned, shipping charges prepaid and will be returned, after repair, shipping charges paid. Kussmaul Electronics Company, Inc. shall have no liability for damages of any kind to associated equipment arising from the installation and /or use of the Kussmaul Electronics Company, Inc. products. The purchaser, by the acceptance of the equipment, assumes all liability for any damages which may result from its installation, use or misuse, by the purchaser, his or its employees or others. ...

  Know our Partners   Frequently Asked Questions   Contact Diplodocs team   Last searches
Latest additions
  Sitemap
Brands starting with A B C D E F G H I J K L M N O P Q R S T U V W X Y Z #
Copyright © 2005 - 2008 - Diplodocs - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.