Download user guide, user manual, owner manual and instructions guide
5 600 brands
1 870 000 user's guides
Search a brand
Advanced Search



Our partners wish to propose you the following products


Visit LG official site

User manual LG *

Diplodocs help download the user guide LG *.



Download the user manual LG *  
Download the complete
user guide (1166 Ko)
Need help, support, reviews, tips or troubleshooting for your LG * products ?


You may also download the following manuals related to this product:
LG -CB773F-EJ-
LG -CS990E-EV-
LG (WS771B)
LG -CB773F-NJ-
LG -CS778F-NJ-
LG -CS778F-EJ-

This product, although classified under the brand LG, may have been manufactured by GOLDSTAR, ZENITH after mergers, acquisitions, or a change in name.

Preview of the first 3 pages of manual

You either have JavaScript turned off or an old version of Adobe Flash Player
Get the latest Flash Player.
User guide LG *

Detailed instructions for use are in the User's Guide.

ENGLISH ITALIANO ESPAÑOL Room Air Conditioner OWNER'S MANUAL · Please read carefully and thoroughly this manual before operating this unit. · Contact the authorized SVC man for repair or maintenance of this unit. · Contact the installer for installation of this unit. · The appliance is not intended for use by young children or infirm persons without supervision. · Young children should be supervised to ensure that they do not play with the appliance. MODELS: LS-J07_Series LS-J09_Series LS-L12_Series LS-K18_Series LS-K24_Series S07_Series S09_Series S12_Series S18_Series S24_Series FRANÇAIS DEUTSCH GREEK Prior to installation, this air-conditioning unit must be submitted for approval by the utility service which provides electricity (EN 61000-3 Norm). Safety Precautions Safety precautions Safety Precautions Warning ................................2 Caution .................................3 To prevent injury to the user or other people and property damage, the following instructions must be followed. s Incorrect operation due to ignoring of instruction will cause harm or damage, the seriousness is classified by the following indications. Operating Instructions Preparation before operation ..4 Remote Control Features .....5 Operation Mode Selection ......7 Additional features..............13 WARNING This symbol indicates the possibility of death or serious injury. CAUTION This symbol indicates the possibility of injury or damage to properties only. Operating Instructions Care and Maintenance Care and Maintenance .......16 Operation Tips ....................18 Installation precautions WARNING WARNING s Do not install, remove and reinstall the unit by yourself. · Improper installation will cause water leakage, electrical shock, or fire. Please consult authorized dealer or specialist for the installation work. Please note fault caused by improper installation is not covered by warranty. · Unit must be installed in an easily accessible area. Any additional cost required to hire a special equipment to service the unit will be the responsibility of the customer. Troubleshooting tips Before You Call For Service ...............19 Care and Maintenance WARNING WARNING Plug in the power plug properly. · Otherwise, it will cause electrical shock or fire due to heat generation. Do not operate or stop the unit by inserting or pulling out the power plug. · It will cause electrical shock or fire due to heat generation. Do not damage or use an unspecified power cord. · It will cause electrical shock or fire. · If the supply cord is damaged, it must be replaced by the manufacturer or its service agent or a similarly qualified person in order to avoid a hazard. Do not insert anything into the air inlet/air outlet. · Since the fan rotates at high speed, this may cause an injury or damage the unit. Repair or relocation should not be done by the customer. · If this is done incorrectly, it may cause a fire, electric shock, injury by dropping of the unit, water leakage, etc. Consult your dealer. Do not modify power cord length or share the outlet with other appliances. · It will cause electrical shock or fire due to heat generation. Do not expose the skin directly to cool air for long periods of time. · This could damage your health. Do not operate with wet hand. · It may cause electrical shock. When an abnormality (smell of burning, etc) occurs, stop the air conditioner, and disconnect the power plug or turn off the breaker. Troubleshooting Tips · If the unit continues to be operated in an abnormal condition, it may cause a fire, damage, etc. In this case, consult your dealer. 2 CAUTION · Contact the authorized Service technician for repair or maintenance of this unit. · Contact the installer for installation of this unit. · The air conditioner is not intended for use by young children or infirm persons without supervision. · Young children should be supervised to ensure that they do not play with the air conditioner. ENGLISH CAUTION CAUTION When the air filter is to be removed, do not touch the metal parts of the indoor unit. · It may cause an injury. · Should be disconnected from supply When the unit is to be cleaned, switch off, and turn off the circuit breaker. · Since the fan rotates at high speed during operation, it may cause an injury. Do not apply an insecticide or flammable spray. Do not clean the air conditioner with water. Ventilate well when used together with a stove, etc. · Water may enter the unit and degrade the insulation. It may cause an electric shock. Do not put a pet or house plant where it will be exposed to direct air flow. · This could injure the pet or plant. Do not put a stove, etc. where is exposed to direct air flow. · It may affect combustion. · An oxygen shortage may occur. Do not leave on installation stand which is damaged. · The unit may drop or fall down and cause an injury. Do not step on the indoor/outdoor unit and do not put anything on it. · It may cause an injury through dropping or falling down. Do not step onto an unstable bench when cleaning and/or maintaining the unit. · It may cause an injury, etc. by falling down. · It may cause a fire or deformation of the cabinet. Do not insert hands through vanes when the air conditioner is operationg · It will cause an injury by the rotating blower. Do not use for special purposes. When the unit is not going to be used for a long time, turn off the circuit breaker. · If not, dirt may collect and cause a fire. Do not operate for a long time in high humidity, e.g. leaving a door or window open. · In the cooling mode, if it is operated in a room with high humidity (80%RH or more) for a long time, water condensed in the air conditioner may drop and may wet and spoil furniture, etc. · Do not use this air conditioner to preserve precision devices, food, animal, plants, and art objects. It may cause deterioration of quality, etc. 3 Safety Precautions Preparation before operation How to Insert the Batteries Remove the battery cover by pulling it according to the arrow direction. Insert new batteries making sure that the (+) and (-) of battery are installed correctly. Reattach the cover by sliding it back into position. Operating Instructions NOTES: · Use 2 AAA(1.5volt) batteries. Do not use rechargeable batteries. Storage and Tips For Using the Remote Control · The remote control may be stored mounted on a wall. · To operate the room air conditioner, aim the remote control at the signal receptor. Care and Maintenance Signal Receptor Receives the signals from the remote control.(Signal receiving sound: two short beeps or one long beep.) Operation Indication Lamps On/Off : Lights up during the system operation. : Lights up during Sleep Mode Auto operation. : Lights up during Timer operation. : Lights up during Defrost Mode or Hot Start operation (Heat pump model only) Troubleshooting Tips Sleep Mode Timer Defrost Mode OUT DOOR OUTDOOR UNIT : Lights up during outdoor unit operation. OPERATION (Cooling model only) Power Display (Inverter only) : Indicates the setting temperature and the receptor operating frequency of compressor.(5 steps) Operation indication lamps Signal 4 About the remote control on the system The remote control transmits the signals to the system. ENGLISH Features of the Remote Control- Door Closed 1 START/STOP BUTTON Operation starts when this button is pressed and stops when the button is pressed again. 2 OPERATION MODE SELECTION BUTTON Used to select the operation mode. 3 5 4 6 1 ROOM TEMPERATURE SETTING BUTTONS Used to select the room temperature. 4 3 INDOOR FAN SPEED SELECTOR Used to select fan speed in four steps low, medium, high, or CHAOS. Flip-up door (closed) 5 JET COOL Used to start or stop the speed cooling. (Speed cooling operates super high fan speed in cooling mode.) 2 6 CHAOS SWING BUTTON Used to stop or start louver movement and set the desired up/down airflow direction. Operation Mode Cooling Operation Cooling Operation Auto Operation Auto Operation Healthy Dehumidification Operation Healthy Dehumidification Operation (Cooling Model) Heating Operation (Heat Pump Model) 5 Safety Precautions Features of the Remote Control- Door Opened 1 Signal transmitter ON/OFF TIMER BUTTONS Used to set the time of starting and stopping operation. 2 Operating Instructions TIME SETTING BUTTONS Used to adjust the time. (See page 13) 3 TIMER SET/CANCEL BUTTONS Used to set the timer when the desired time is obtained and to cancel the Timer operation. (See page 13) 4 SLEEP MODE AUTO BUTTON Used to set Sleep Mode Auto operation. (See page 13) ON OFF 5 4 5 6 PLASMA AIR CIRCULATION BUTTON Used to circulate the room air without cooling or heating (turns indoor fan on/off). (See page 14) 1 Care and Maintenance 2 SET CANCEL 3 7 8 6 ROOM TEMPERATURE CHECKING BUTTON Used to check the room temperature. 7 PLASMA(OPTION) Used to start or stop the plasma-purification function. (See page 12) 8 Troubleshooting Tips RESET BUTTON Used prior to resetting time or after replacing batteries. 6 How to use the Operation Mode Selection button Cooling Operation ENGLISH 1 Press the Start/Stop button. The unit will respond with a beep. 2 Open the door on the remote control. To select Cooling Operation, press the Operation Mode Selection button. Each time the button is pressed, the operation mode is shifted in the direction of the arrow. Cooling Auto Healthy Dehumidification Heating (Heat pump model only) 3 Close the door on the remote control. Set the temperature lower than the room temperature. The temperature can be set within a range of 18°C~30°C in 1°C increments. To raise the temperature To lower the temperature 4 Set the fan speed again with the door of the remote control still closed. You can select the fan speed in four stepslow, medium, high, or CHAOS. Each time the button is pressed, the fan speed mode is shifted. Natural wind by the CHAOS logic For more fresh feeling than other fan speed, press the Indoor Fan Speed Selector and set to CHAOS mode. In this mode, the wind blows like natural breeze by automatically changing fan speed according to the CHAOS logic. 7 Safety Precautions Auto Operation 1 Press the Start/Stop button. The unit will respond with a beep. Operating Instructions 2 Open the door on the remote control. To select Auto Operation, press the Operation Mode Selection button. Each time the button is pressed, the operation mode is shifted in the direction of the arrow. Cooling Auto Care and Maintenance Healthy Dehumidification Heating (Heat pump model only) 3 The temperature and fan speed are automatically set by the electronic controls based on the actual room temperature. If you want to change the set temperature, close the door on the remote control and press the Room Temperature Setting buttons. The cooler or warmer you feel, the more times (up to two times) you should press the button. The set temperature will then be changed automatically. To raise the temperature Troubleshooting Tips To lower the temperature During Auto Operation: You cannot switch the indoor fan speed. It has already been set by the Fuzzy rule. If the system is not operating as desired, manually switch to another mode. The system will not automatically switch from the cooling mode to the heating mode, or from heating to cooling, it must be done by manually resetting. During Auto Operation, pressing the chaos swing button makes the horizontal louvers swing up and down automatically. If you want to stop auto-swing, press the chaos swing button again. 8 Healthy Dehumidification Operation ENGLISH 1 Press the Start/Stop button. The unit will respond with a beep. 2 Open the door on the remote control. To select Healthy Dehumidification Operation, press the Operation Mode Selection button. Each time the button is pressed, the operation mode is shifted in the direction of the arrow. Cooling Auto Healthy Heating Dehumidification (Heat pump model only) 3 Set the fan speed again with the door of the remote control still closed. You can select the fan speed in four stepslow, medium, high, or CHAOS. Each time the button is pressed, the fan speed mode is shifted. Natural wind by the CHAOS logic For more fresh feeling than other fan speed, press the Indoor Fan Speed Selector and set to CHAOS mode. In this mode, the wind blows like natural breeze by automatically changing fan speed according to the CHAOS logic. During Healthy Dehumidification Operation: If you select the dehumidification mode on the operation selection button, the A/C starts to run the dehumidification function, automatically setting the room temp. and airflow volume to the best condition for dehumidification based on the sensed current room temp. In this case, however, the setting temp. is not displayed in the remote control and you are not able to control the room temp. either. During the healthy dehumidification function, the airflow volume is automatically set according to the optimization algorithm responding to the current room temp. status and makes the room condition healthy and comfortable even in the high humidity season. 9 Safety Precautions Heating Operation(Heat pump model only) 1 Press the Start/Stop button. The unit will respond with a beep. Operating Instructions 2 Open the door on the remote control. To select Heating Operation, press the Operation Mode Selection button. Each time the button is pressed, the operation mode is shifted in the direction of the arrow. Cooling Auto Healthy Heating Dehumidification (Heat pump model only) Care and Maintenance 3 Close the door on the remote control. Set the temperature higher than the room temperature. The temperature can be set within a range of 16°C~30°C in 1°C increments. To raise the temperature To lower the temperature 4 Troubleshooting Tips Set the fan speed again with the door of the remote control still closed. You can select the fan speed in four steps­low, medium, high, or CHAOS. Each time the button is pressed, the fan speed mode is shifted. Natural wind by the CHAOS logic For more fresh feeling than other fan speed, press the Indoor Fan Speed Selector and set to CHAOS mode. In this mode, the wind blows like natural breeze by automatically changing fan speed according to the CHAOS logic. 10 Jet Cool Operation ENGLISH 1 Press the Start/Stop button. The unit will respond with a beep. 2 Press the Jet Cool button to operate the speed cooling mode and the unit will operate in super high fan speed on cooling mode for 30 minutes. 3 To cancel the Jet Cool mode, press the Jet Cool button again or the fan speed button or the room temperature setting button and the unit will operate in high fan speed on cooling mode. or or NOTE: During the JET COOL function at any moment, the A/C starts to blow the cool air at extremely high speed for 30 minutes setting the room temp. automatically to 18°C. It is especially used to cool the room temp. in the shortest time in a hot summer. In heat pump mode or neuro fuzzy mode however, the JET COOL function is not available. In order to return to the normal cooling mode from the JET COOL mode, you just press either the operation mode selection button, airflow volume selection or temp. setting button or the JET COOL button again. 11 Safety Precautions PLASMA Purification Operation(Option) 1 Press the Start/Stop button. The unit will respond with a beep. Operating Instructions 2 Open the door on the remote control. Press the PLASMA air purifying operation ON/OFF button. Operation will start when the button is pressed and stop when the button is pressed again. PLASMA Care and Maintenance 3 Set the fan speed again with door of the remote control closed. You can select the fan speed in four steps-low, medium, high or CHAOS. Each time the button is pressed, the fan speed mode is shifted. Air purifying operation (PLASMA) with cooling, Heating or any other operations. Troubleshooting Tips PLASMA Air Purifying Operateion only If you press the only PLASMA button, PLASMA air purifying operates only. Then, fan speed is low. You can select the fan speed in four steps-low, medium, high or CHAOS. Each time the button ( ) is pressed, the fan speed mode is shifed. PLASMA 12 Additional features Sleep Mode 1 2 Press the Sleep Mode Auto button to set the time you want the unit to turn off automatically. The Timer is programmed in one-hour increments by pressing the Sleep Mode Auto button 1 to 7 times. The sleep mode is available for 1 to 7 times. To alter the time period in steps of 1 hour, press the Sleep Mode Button while aiming at air conditioner. Make sure the Sleep Mode Auto LED lights up. To cancel the Sleep Mode, press the sleep Mode Auto button several times until the star ( ) disappears from the operation display. Note: The Sleep Mode will be operated at low fan speed (cooling) or medium fan speed (heat pump only) for quiet sleeping. IN COOLING MODE: The temperature will automatically rise by 1°C over the next 30 minutes and by 2°C in 1 hour for comfortable sleeping. ENGLISH 3 Setting the Time 1 Time can be set only when you have pressed the Reset button. If you have just replaced the batteries, the Reset button should be pressed to reset the time. Press the Start/Stop button. 2 Press the Time Setting buttons until the desired time is set. 3 Press the Timer SET button. Note: Check the indicator for A.M. and P.M. SET Delay Start/Pre-Set Stop 1 2 Make sure the time is set correctly on the remote control display. ON OFF 4 Press the selected on/off setting by pressing the Timer SET button while aiming the remote control at the signal receptor. SET Press the ON/OFF Timer buttons to turn Timer on or off. 3 Press the Time Setting buttons until the desired time is set. To cancel the setting the timer. Press the Timer Cancel button while CANCEL aiming remote control at the signal receptor. (The timer lamp on the air conditioner and the display will go out.) NOTE: Select one of the following four types of operation. with the unit running Delay OFF Timer Delay ON Timer Delay OFFand ON Timer Delay ONand OFF Timer 13 Safety Precautions Vertical Airflow Direction Control The up/down airflow (Vertical Airflow) can be adjusted by using the remote control. Note: If you press the CHAOS swing button, the horizontal airflow direction is changed automatically based on the CHAOS algorithm to distribute the air in the room evenly and at the same time to make the human body feel most comfortable, as if enjoying a natural breeze. Always use the remote control to adjust the up/down airflow direction. Manually moving the vertical airflow direction louver by hand could damage the air conditioner. When the unit is shut off, the up/down airflow direction louver will close the air outlet vent of the system. To adjust left/right(Horizontal Airflow) direction Caution : Ensure unit is turned off before adjusting the horizontal airflow direction control. Carefully open vertical louver to allow access to the horizontal airflow direction. Adjust the left/right airflow direction by hand. Operating Instructions Press the Start/Stop button to start the unit. Open the door on the remote control. Press Chaos Swing button and the louvers will swing up and down. Press the Chaos Swing button again to set the vertical louver at the desired airflow direction. Care and Maintenance Air Circulation Mode Circulates the room air without cooling or heating. 1 2 Press the Start/Stop button. the unit will respond with a beep. Open the door on the remote control. Press the Air Circulation button. Close the door on the remote control. Now each time that you press the Indoor Fan Speed Selector, the fan speed is shifted from low to CHAOS and back to low again. Troubleshooting Tips CHAOS Air Fan speed is on low. Fan speed is on medium. Fan speed is on high. Note: CHAOS Air economizes power consumption and prevents overcooling. The fan speed is automatically changed from high to low or vice versa, depending on the ambient temperature. 14 Slide Switch Operation FORCED OPERATION Operation procedures when the remote control can't be used. Open the front panel upward and move the Slide Switch to the Forced Operation position. If you want to stop operation, move the Slide Switch to the Auto Restart or the Remote Control position. In case the power comes on again after power failure on the Forced Operation position, the operating conditions are automatically set as follows: During Forced Operation, the initial mode continues. Slide Switch Open the front panel upward Slide Switch FORCED OPERATION AUTO RESTART REMOTE CONTROL ENGLISH Cooling Model Operating mode Indoor FAN Speed Setting Temperature Cooling High 22°C Room Temp. 24°C Cooling High 22°C Heat pump Model 21°C Room Temp. < 24°C Healthy Dehumidification Healthy Dehumidification Rule 23°C Room Temp. < 21°C Heating High 24°C Auto restart In case the power comes on again after a power failure, Auto Restarting Operation is the function to operate procedures automatically to the previous operating conditions. If you want to use this operation, Open the front panel upward and move the slide switch to the Auto Restart position. If you do not want to use this operation, move the Slide Switch to the Remote Control position. Slide Switch FORCED OPERATION AUTO RESTART REMOTE CONTROL Slide Switch Open the front panel upward When you are out for a while, put the Slide Switch on the Remote Control. Helpful information Fan speed and cooling capacity. The cooling capacity indicated in the specification is the value when the fan speed is set to high, and the capacity will be lower at low or medium fan speed. High fan speed is recommended when you wish to cool the room quickly. gh Hi eed Sp 15 Safety Precautions Care and maintenance of the air conditioner CAUTION: Before performing any maintenance, turn off the main power to the system. Indoor Unit Grille, Case, and Remote Control Turn the system off before cleaning. To clean, wipe with a soft, dry cloth. Do not use bleach or abrasives. NOTE: Supply power must be disconnected before cleaning the indoor unit. Never use any of the followings: · Water hotter than 40°C Could cause deformation and/or discoloration. · Volatile substances Could damage the surfaces of the air conditioner. Operating Instructions P o wd er G asoline Air inlet vent Air outlet vent Air filters (behind front panel) Vertical louver Horizontal louver 1 AIR FILTERS The air filters behind the front grille should be checked and cleaned once every 2 weeks or more often if neccessary. Lift the front access panel and pull the filter tab slightly forward to remove the filter. water. · If dirt is conspicuous, wash with a solution of detergent in lukewarm water. · If hot water (40°C or more) is used, it may be deformed. shade. 2 Clean the filter with a vacuum or warm, soapy Care and Maintenance 3 After washing with water, dry well in the 4 Re-install the air filter. PLASMA FILTER, DEODORIZER FILTER(OPTION) The PLASMA filter behind the air filters should be checked and cleaned once every 3 months or more often if necessary. 1 After removing the air filters, pull slightly forward to remove the PLASMA filter. 2 Dip the PLASMA filter into the water mixed with neutral detergent, for 20~30 minutes. 3 Dry the PLASMA filter in the shade for a day (Especially, the humidity must be removed perfectly on this parts). Troubleshooting Tips 4 Note the cuts of electric discharge lines. DEODORIZER Filter PLASMA Filter 5 Re-install the PLASMA filter to the original position. 1 forward to remove the DEODORIZER filter. Don't touch this PLASMA Filter within 10 seconds after opening the inlet grille, it may cause an electric shock. After removing the air filters, pull slightly 2 Dry in the sunlight for tow hours. 3 original position. Re-install the DEODORIZER filter to the 16 Replacement of Purifying Filter(Option) · Recomended use period : About 2 years ENGLISH 1 Open front panel and remove air filters. 2 Remove air purifying filters. 3 Insert new air purifying filters. 2 Air filter 3 4 Reinsert air filters and close front panel. Air purifying filter Outdoor Unit The heat exchanger coils and panel vents of the outdoor unit should be checked regularly. If clogged (Side) with dirt or soot, the heat exchanger and panel Air intake vents vents may be professionally steam cleaned. NOTE: Air outlet vents Dirty or clogged coils will reduce the operating efficiency of the system and cause higher operating costs. (Rear) (Rear) Air intake vents (Side) Piping Drain Hose Air intake vents Air outlet vents (Side) Piping Drain Hose (Rear) Piping Drain Hose Air outlet vents 17 Safety Precautions When the air conditioner is not going to be used for a long time. When air conditioner is not going to be used for a long time. Operate the air conditioner on Air circulation mode (Refer to page 14) for 2 to 3 hours. · This will dry out the internal mechanisms. When the air conditioner is to be used again. Clean the air filter and install it in the indoor unit. (Refer to page 16 for cleaning filters.) Operating Instructions Turn off the circuit breaker, and disconnect the plug. CAUTION Turn off the circuit breaker when the air conditioner is not going to be used for a long time. Dirt may collect and may cause a fire. Remove the batteries from the remote control. Check that the air inlet and outlet of the indoor/outdoor unit are not blocked. Care and Maintenance Operation Tips Do not overcool the room. Keep blinds or curtains closed. Do not let direct sunshine enter the room when the air conditioner is in operation. Keep the room temperature uniform. Adjust the vertical and horizontal airflow direction to ensure a uniform temperature in the room. This is not good for the health and wastes electricity. Troubleshooting Tips Make sure that the doors and windows are shut tight. Avoid opening doors and windows as much as possible to keep the cool air in the room. Clean the air filter regularly. Ventilate the room occasionally. Since windows are kept closed, it is a good idea to open them and ventilate the room now and then. Blockages in the air filter reduce the airflow and lower cooling and dehumidifying effects. Clean at least once every two weeks. 18 Before you call for service... ? Troubleshooting Tips! Save time and money! ENGLISH Check the following points before requesting repairs or service.... If the fault persists, please contact your dealer or service center. Case The air conditioner does not operate. Explanation · Have you made a mistake in timer operation? · Has the fuse blown or has the circuit breaker been tripped? · Check that this is not a damp smell exuded by the walls, carpet, furniture, or cloth items in the room. · Condensation occurs when the airflow from the air conditioner cools the warm room air. See page 13 - The room has a peculiar odor. - It seems that condensation is leaking from the air conditioner. Air conditioner does not operate for about 3 minutes when restarted. Does not cool or heat effectively. - · This is the protector of the mechanism. · Wait about three minutes and operation will begin. · Is the air filter dirty? See air filter cleaning instructions. · Has the temperature been set incorrectly? · Are the indoor unit's air inlet or outlet vents obstructed? · For a noise that sounds like water flowing. -This is the sound of freon flowing inside the air conditioner unit. · For a noise that sounds like the compressed air releasing into atmosphere. -This is the sound of the dehumidifying water being processed inside the air conditioning unit. · Are the batteries depleted? · Are the batteries inserted in the opposite (+) and (-) directions? · This sound is generated by the expansion/constriction of the front panel, etc. due to changes of temperature. - 16 7, 10 - The air conditioner operation is noisy. - Remote control display is faint, or no display at all. 4 Crack sound is heard. - NOTE WATER RESISTANT: The outdoor side of this appliance is WATER RESISTANT. The indoor side is not water resistant and should not be exposed to excess water. 19 P/No.: 3828A20083U Printed in Korea

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Diplodocs provides you a fast and easy access to the user manual LG *.

LG offer a product for which we do not have the user manual? Let us know what you are looking for: site Internet, histoire, actualité, filiales, site Internet, mode d'emploi, driver, avis des utilisateurs, meilleur prix des produits, forum d'assistance aux problèmes, annuaire des marques, annuaire des constructeurs, répertoire des marques, répertoire des constructeurs, site Internet de la marque, site Internet du constructeur

Diplodocs allows you to download user manual LG *, user guide LG *, instructions LG *, owner's manual LG *, online manual LG *.


Access web reviews LG *, GOLSTAR, L G, LG ELECTRONIC, LG ELECTRONICS, LGE, Heating & Air Conditioning.
Include the add-on to download manuals from your site, forum or blog Frequently Asked Questions Contact Diplodocs team Last searches
Last additions
Sitemap
Brands starting with A B C D E F G H I J K L M N O P Q R S T U V W X Y Z #
Copyright © 2005 - 2008 - Diplodocs - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.