9 562 brands
2 694 000 user's guides


Download your manual, it's FREE! Diplodocs allows you to download several types of document in order to best use your LG LW-N2461BCG- : user manual, user guide, instruction manual.
Search a brand
Advanced Search

User manual LG LW-N2461BCG-

Diplodocs help download the user guide LG LW-N2461BCG- .

Download the complete user guide (3305 Ko)



This product, although classified under the brand LG, may have been manufactured by GOLDSTAR, ZENITH after mergers, acquisitions, or a change in name.



Preview of the first 3 pages of manual

You either have JavaScript turned off or an old version of Adobe Flash Player
Get the latest Flash Player.
Manual abstract: user guide LG LW-N2461BCG-

Detailed instructions for use are in the User's Guide.

Room Air Conditioner (Window Type) OWNER'S MANUAL Safety precautions Safety Precautions Safety Precautions .............3 FOR YOUR RECORDS Write the model and serial numbers here: Model # Serial # You can find them on a label on the side of each unit. Dealer's Name Date Purchased Operating instructions Operating Instructions About the Controls on the Air Conditioner .........................5 Care and Maintenance .......8 READ THIS MANUAL Inside you will find many helpful hints on how to use and maintain your air conditioner properly. Just a little preventive care on your part can save you a great deal of time and money over the life of your air conditioner. You'll find many answers to common problems in the chart of troubleshooting tips. If you review our chart of Troubleshooting Tips first, you may not need to call for service at all. Installation Instructions Installation Instructions Features...............................9 Installation Instructions.........9 CAUTION Contact the authorized service technician for repair or maintenance of this unit. Contact the installer for installation of this unit. The air conditioner is not intended for use by young children or infirm persons without supervision. Young children should be supervised to ensure that they do not play with the air conditioner. Troubleshooting tips Troubleshooting Tips Before You Call for Service..................11 -2- Safety Precautions Safety Precautions To prevent injury to the user or other people and property damage, the following instructions must be followed. Incorrect operation due to ignoring of instruction will cause harm or damage, the seriousness is classified by the following indications. WARNING CAUTION : : This symbol shows the possibility of causing death or serious injury. This symbol indicates the possibility of injury or damage to properties only. The items to be followed are classified by the following symbols. Never Do This Always Do This The airconditioner should be installed in accordance with national wiring regulation Following circuit breaker/fuse rating to be used as per unit specification LW-C12..CI(12000 Btu/Hr) 15A, LW-N18..CI(18000 BTu/Hr )-20A ,LW-N24..CI(24,000 Btu/Hr )-30A WARNING Plug in the power plug properly. Otherwise, it will cause electric shock or fire due to heat generation or electrical shock. Do not operate or stop the unit by inserting or pulling out the power plug. It will cause electrical shock or fire due to heat generation. Do not damage or use an unspecified power cord. It will cause electrical shock or fire. If the supply cord is damaged, it must be replaced by a special cord or assembly available from the manufacturer or its service agent. Do not modify power cord length or share the outlet with other appliances. It will cause electrical shock or fire due to heat generation. Do not operate with wet hands or in damp environment. It may cause electrical shock. Do not direct airflow at room occupants only. This could damage your health. If your airconditioner is not provided with a plug then there should be some means for disconnection of both live & neutral poles having a contact seperation of minimum 3mm & must be Incorporated in fixed wiring in accordance to wiring rules -3- Safety Precautions CAUTION Never touch the metal parts of the unit when removing the filter. It may cause an injury. Do not clean the air conditioner with water. Water may enter the unit and degrade the insulation. It may cause an electric shock. Ventilate well when used together with a stive, etc. An oxygen shortage may occur. When cleaning the unit, first make sure the power and breaker are turned off. Since the fan rotates at high speed during operation, it may cause an injury. Do not put a pet or house plant where it will be exposed to direct air flow. This could injure the pet or plant. Do not use for special purposes. Do not use this air conditioner to preserve precision devices, food, pets, plants, and art objects. It may cause deterioration of quality, etc. Do not operate Switches with wet hands. Do not apply an insecticide or flammable spray. Do not put a heater, etc. where is exposed to direct air flow. It may cause imperfect combustion. It may cause an electric shock. It may cause a fire or deformation of the cabinet. -4- About the Controls on the air conditioner The controls will look like the following. Controls OPERATION High Cool ( ), Med Cool ( ) and ) provide cooling with different fan Low Cool ( speeds. Med Fan ( ) or Low Fan ( ) provides air circulation and filtering without cooling. Off ( O ) turns the air conditioner off. NOTE: If you move the switch from a cool setting to off or to a fan setting, wait at least 3 minutes before switching back to a cool setting. Operating Instructions Cooling Descriptions THERMOSTAT (TEMPERATURE) The THERMOSTAT/TEMPERATURE is used to maintain the room temperature. The compressor will cycle on and off to keep the room at the same level of comfort. When you turn the knob to a higher number (the right side) and the indoor air will become cooler. The 5 or 6 position (the middle position of arc) is a normal setting for average conditions. For Normal Cooling- Select High Cool or Med Cool with the OPERATION knob at the midpoint of THERMOSTAT/TEMPERATURE knob. For Maximum Cooling- Select High Cool with the OPERATION knob at the highest number available on your THERMOSTAT/TEMPERARURE knob. For Quieter & Nighttime Cooling- Select Low Cool with the OPERATION knob at the midpoint of THERMOSTAT/TEMPERATURE knob. OPERATION HIGH ( ) Cool, LOW ( ) Cool provide cooling with different fan speeds. HIGH ( )heat, LOW( ) heat provide heating with different fan speeds. FAN ( ) provides air circulation and filtering without cooling or heating. OFF ( O ) turns the air conditioner off. NOTE: If you move the switch from the cool(or the heat) setting to off or to a fan setting, wait at least 3 minutes before switching back to a cool(or heat) setting. Cooling Descriptions THERMOSTAT (TEMPERATURE) The THERMOSTAT/TEMPERATURE is used to maintain the room temperature. The compressor will cycle on and off to keep the room at the same level of comfort. The temperature is selected by turning the THERMOSTAT/ TEMPERATURE knob to the desired position. For Normal Cooling- Select HIGH Cool with the OPERATION knob at the midpoint of the THERMOSTAT/TEMPERATURE knob. For Maximum Cooling- Select HIGH Cool with the OPERATION knob at the clockwise available on the THERMOSTAT/TEMPERATURE knob. For Quieter & Nighttime Cooling- Select LOW Cool with the OPERATION knob at the midpoint of the THERMOSTAT/ TEMPERATURE knob. Heating Descriptions For Normal Heating- Select HIGH heat with the OPERATION knob at the midpoint of the THERMOSTAT/TEMPERATURE knob. For Maximum Heating- Select HIGH heat with the OPERATION knob at the counterclockwise available on the THERMOSTAT/TEMPERATURE knob. For Quieter Heating- Select LOW heat with the OPERATION knob at the midpoint of the THERMOSTAT/TEMPERATURE knob. HEATER LAMP At the heating operation, the lamp is lighted. When the frost settles on the heat exchanger of the outside, defrosting is made automatically and the lamp is unlighted. After defrosting, the heating operation begins again. AUTO SWING Auto swing switch controls the horizontal air direction by air swing system (not on all models). ON ( ) : Auto swing is operated. OFF ( ) : Auto swing is not operated. -5- Operating Instructions Controls Precaution: The Remote Control unit will not function properly if strong light strikes the sensor window of the air conditioner or if there are obstacles between the Remote Control unit and the air conditioner. POWER BUTTON Operation starts, when this button is pressed and stops when you press the button again. OPERATION MODE SELECTION BUTTON Select Cooling Fan or Dehumidification (Dry) mode with this button. ON/OFF TIMER/SLEEP BUTTON Set the time of on/off operation. The timer can be set by the one hour for a maximum of 12 hours. In the first 30 minutes set temperature increases by 1°C and in the next 30 minutes temperature increases by another 1°C, this temperature then remains till the timer function is activated. This is how the sleep function behaves. FAN SPEED SELECTOR Select the fan speed in Three steps Low (F1) / Med. (F2) / High (F3) ROOM TEMPERATURE SETTING BUTTON Control the room temperature within a range of 16°C to 30°C. AUTO SWING The vertical louver swings horizontally by the automatic system and stops when you press the button again. SIGNAL RECEIVER ENERGY SAVER The fan stops when the compressor stops cooling. Approximately even 3 minutes the fan will turn on and check the room air to determine if cooling is needed. FOR PLASMA MODEL- AIR PURIFIER Used to Start or Stop the Plasma Purification function AUTO RESTART In failure of electric power the unit runs as previous setting operation when power returns. How to Insert the Batteries Remove the cover from the back of the remote controller. Slide the cover according to the arrow direction. Insert the two batteries. Be sure that the (+) and (-) directions are correct. Be sure that both batteries are new. Re-attach the cover. Slide it back into the position. Do not use rechargeable batteries, such batteries differ from standard dry cells in shape, dimensions, and performance. Remove the batteries from the remote controller if the air conditioner is not going to be used for an extended length of time. -6- Additional controls and important information. Vent Control The vent control is located above the control knobs. When set at CLOSE, only the air inside the room will be circulated and conditioned. When set at OPEN, some inside air is exhausted outside. To open the vent, pull the lever toward you. To close it, push it in. Operating Instructions Air Direction The direction of air can be controlled horizontally or vertically by using the horizontal louver or vertical louver. Horizontal Air-Direction The horizontal air direction is adjusted by setting the AUTO SWING switch to the ON position. Vertical Air-Direction Fingertip pressure on the bank of horizontal louvers adjusts the air direction up or down -7- Care and Maintenance Grille and Case Turn the air conditioner off and remove the plug from the wall outlet before cleaning. To clean, use water and a mild detergent. Do not use bleach or abrasives. Air Filter Operating Instructions Ensure the power is off before open the front Grill. The air filter behind the front grille should be checked and cleaned at least once every 2 weeks or more often if necessary. The grille is designed to clean the filter both upward and downward. To remove: Open the inlet grille upward by pulling out the bottom of the inlet grille or downward by pulling out the top of the inlet grille. Using the tab, pull up slightly on the filter to release it and pull it down or up. Clean the filter with warm, soapy water below 40°C (104°/F). Rinse and gently shake the water from the filter and let it dry before replacing it. CAUTION: DO NOT operate the air conditioner without a filter because dirt and lint will clog it and reduce performance. Drainage In humid weather, excess water may cause the BASE PAN to overflow. To drain the water, remove the DRAIN CAP and secure the DRAIN PIPE to the rear hole of the BASE PAN. To remove the condensed water, you can install the drain pan as below. 1. Take the drain pan which is located in the air discharge. 2. Install the drain pan to the right corner of the cabinet with 4 screws. 3. Connect the drain hose to the outlet located at the bottom of the drain pan. You can purchase the drain hose or tubing locally to satisfy your particular needs. (Drain hose is not supplied). -8- Features Learning parts name prior to installation will help you understanding the installation procedure. Features 1. CABINET 2. FRONT GRILLE 3. AIR FILTER 4. AIR INTAKE(INLET GRILLE) 5. AIR DISCHARGE 6. VERTICAL AIR DEFLECTOR (HORIZONTAL LOUVER) 7. EVAPORATOR 8. HORIZONTAL AIR DEFLECTOR (VERTICAL LOUVER) Installation Instructions Select the Best Location To prevent vibration and noise, make sure the unit is installed securely and firmly. Install the unit where the sunlight does not shine directly on the unit. There should be no obstacle, such as a fence or wall, within 50cm from the back of the cabinet because it will prevent heat radiation of the condenser. Restriction of outside air will greatly reduce the cooling efficiency of the air conditioner. Install the unit a little obliquely outward not to leak the condensed water into the room (about 10 ~ 15mm or 1/4 bubble with level). CAUTION: All side louvers of the cabinet must remain exposed to the outside of the structure. 9. 10. 11. 12. 13. 14. 15. CONTROL BOARD POWER CORD COMPRESSOR BASE PAN BRACE CONDENSER PLASMA FILTER ASSY. Installation Instructions Remove the Air Conditioner From the Case Remove the ...

  Know our Partners   Frequently Asked Questions   Contact Diplodocs team   Last searches
Latest additions
  Sitemap
Brands starting with A B C D E F G H I J K L M N O P Q R S T U V W X Y Z #
Copyright © 2005 - 2008 - Diplodocs - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.