Download user guide, user manual, owner manual and instructions guide
5 600 brands
1 870 000 user's guides
Search a brand
Advanced Search



Our partners wish to propose you the following products


Visit MARTIN official site

User manual MARTIN MAC 250+

Diplodocs help download the user guide MARTIN MAC 250+.



Download the user manual MARTIN MAC 250+  
Download the complete
user guide (653 Ko)
Need help, support, reviews, tips or troubleshooting for your MARTIN MAC 250+ products ?

Preview of the first 3 pages of manual

You either have JavaScript turned off or an old version of Adobe Flash Player
Get the latest Flash Player.
User guide MARTIN MAC 250+

Detailed instructions for use are in the User's Guide.

MAC 250 / MAC 250 user manual + section 1 Safety Safety precautions ................................................................................................................................................... 3 section 2 Setup Unpacking ............................................................................................................................................................... 4 Lamp installation ..................................................................................................................................................... 4 Powering ................................................................................................................................................................. 5 Rigging .................................................................................................................................................................... 6 Connecting the serial data link ................................................................................................................................ 6 section 3 Control Panel Menu navigation ...................................................................................................................................................... 8 Personality settings (P ERS ) ................................................................................................................................... 9 Address and protocol selection ............................................................................................................................. 10 Readouts (I NF O) ................................................................................................................................................ 10 Utilities (U TIL ) .................................................................................................................................................... 10 Test programs (T E ST) ......................................................................................................................................... 11 Manual control (M AN) ........................................................................................................................................... 11 Adjustment (A dJ ) ................................................................................................................................................. 11 section 4 Operation DMX-512 control ................................................................................................................................................... 12 Martin RS-485 control ........................................................................................................................................... 12 Controllable effects ................................................................................................................................................ 12 section 5 Basic Service Replacing the lamp ................................................................................................................................................ 15 Optimizing reflector alignment ............................................................................................................................... 15 Rotating gobos ...................................................................................................................................................... 15 Changing color filters (MAC 250+ only) ................................................................................................................. 16 Configuring the optical system (MAC 250 only) .................................................................................................... 17 Removing modules ................................................................................................................................................ 18 Cleaning ................................................................................................................................................................ 18 Lubrication ............................................................................................................................................................. 18 Replacing fuses ..................................................................................................................................................... 19 Changing the XLR pin-out ..................................................................................................................................... 19 Updating software ................................................................................................................................................. 19 Changing voltage and frequency settings ............................................................................................................ 20 section 6 Appendixes DMX protocol ........................................................................................................................................................ 21 Error messages ..................................................................................................................................................... 24 Troubleshooting ..................................................................................................................................................... 25 PCB layout ............................................................................................................................................................ 26 Specifications ........................................................................................................................................................ 27 ©1998 - 2000 Martin Professional A/S, Denmark. All rights reserved. No part of this manual may be reproduced, in any form or by any means, without permission in writing from Martin Professional A/S, Denmark. Printed in Denmark. P/N 35000067, Rev. D section 1 SAFETY Thank you for selecting the Martin MAC 250 or the MAC 250+. Both the MAC 250 and the MAC 250+ are yokemounted profile spotlights that are designed around a 250 watt discharge lamp. They provide: · · · · · · · 12 saturated dichroic colors 8 replaceable rotating gobos 3-facet rotating prism variable focus strobe effects 0 to 100% dimming accurate 16-bit movement. In addition, the standard MAC 250 provides 4 user-configurable beam angles from 12.1° to 23.3°. The MAC 250+ provides gobo indexing, interchangeable color filters, and an 18.3° achromatic lens system. High-performance optics, attractive design, modular construction and numerous user-friendly features make these Martin fixtures well suited for any effect lighting application calling for a compact, hard-focusing 250 watt fixture. Safety precautions The MAC 250 and MAC 250+ are for professional use only. They are not for household use. They present risks of injury due to electric shock, heat and ultraviolet radiation burns, lamp explosion, falls, high-intensity light, and fire. Read this manual before powering or installing the fixture, follow the safety precautions listed below and observe all warnings in this manual and printed on the fixture. If you have questions about how to operate the fixture safely, please contact your Martin dealer or call the Martin 24-hour service hotline for assistance. · · · · · · ALWAYS disconnect the fixture from AC power before removing or installing the lamp, fuses, or any part; and when not in use. Allow the fixture to cool for at least 5 minutes before replacing the lamp. Keep all combustible materials (for example fabric, wood, paper) at least 0.3 meters (12 inches) away from the fixture. Keep flammable materials well away from the fixture. For protection against dangerous electric shock, always ground (earth) the fixture electrically. Use only a source of AC power that complies with local building and electrical codes. Do not expose the fixture to rain or moisture. Ensure that the air flow through fans and vents is free and unobstructed. When suspending the fixture above ground level, verify that the structure can hold at least 10 times the weight of all installed devices and secure the fixture with an approved safety cable. Block access below the work area whenever installing or removing the fixture. Refer any service operation not described in this manual to a qualified technician. Do not illuminate surfaces within 0.3 meters (12 inches) of the fixture. Never place filters or other materials over the lens. Do not operate the fixture if the ambient temperature (Ta) exceeds 40° C (104° F). Replace the lamp as soon as it becomes defective or worn out, or before usage exceeds the maximum service life. Do not stare directly into the light. Never operate the fixture without all lenses and covers installed: an unshielded lamp can explode without warning and emits dangerous UV radiation that can cause burns and eye damage. Do not modify the fixture or install other than genuine Martin accessories and upgrade kits. · · · · · · · · Safety 3 section 2 SETUP Unpacking The MAC 250 and MAC 250+ come with: · · · · 1 1/4-turn clamp mounting bracket 1 5-meter, 3-pin shielded XLR control cable 1 3-meter, 3-wire IEC power cable 1 user manual The packing material is carefully designed to protect the fixture during shipment - always use it or a custom flight case to transport the fixture. Lamp installation Compatible lamps The lamps listed in the table below may be used with the MAC 250 and MAC 250+. Installing any other lamp may damage the fixture. Lamp Osram HSD 250 Philips MSD 250/2 Philips MSD 200 Replace before 2500 hr 2200 hr 2200 hr Average life 2000 hr 2000 hr 2000 hr Color Temp. 6000K 6500K 5600K Output 68 lm/W 72 lm/W 67 lm/W P/N 97010103 97010100 97010106 WA R N I N G ! Disconnect the fixture from AC power and allow the lamp to cool for at least 5 minutes before proceeding. Wear safety goggles to protect your eyes. reflector alignment screws lamp socket assembly Figure 1: Lamp installation 4 MAC 250 and MAC 250+ To i n s t a l l a l a m p 1. Remove the 2 Phillips screws from the lamp socket assembly. Pull the lamp and socket out of the head. 2. Remove the old lamp, if any, from the socket. 3. Holding the new lamp by its ceramic base (do not touch the glass), align the small pin with the small hole and insert the lamp squarely into the socket. Make sure that the 4 small projections on the base contact the face of the socket. 4. Clean the glass bulb with the cloth supplied with the lamp, particularly if your fingers touched the glass. A clean, lint-free cloth wetted with alcohol may also be used. 5. Gently insert the assembly, making sure the lamp fits through the opening in the reflector. Replace the 2 screws. 6. The reflector is pre-adjusted at the factory; however, precise alignment to compensate for variations between lamps may improve performance. See "Optimizing reflector alignment" on page 15. Pow e r i n g WA R N I N G ! For protection from dangerous electric shock, the fixture must be grounded (earthed). The AC mains supply shall be fitted with a fuse or circuit breaker and ground-fault protection. 1. Verify that the voltage and frequency settings match the local AC supply. The factory settings are printed on a label under the base. Check Table 7 on page 20 to verify that these settings are correct for your local AC voltage. Operating at the incorrect power setting can result in poor light output, greatly reduced lamp life, overheating and damage to the fixture. Refer to "Changing voltage and frequency settings" on page 20 if the settings need to be adjusted. 2. Install a grounding-type cord cap that fits your supply on the power cable. Following the manufacturer's instructions, connect the yellow/green wire to the ground (earth) pin, the blue wire to the neutral pin, and the brown wire to the live pin. The table shows some possible pin identification schemes; if the pins are not clearly identified, or if you have any doubts about proper installation, consult a qualified electrician. Wire brown blue yellow/green Pin live neutral ground Marking "L" "N" Screw (US) yellow or brass silver green Table 1: Cord cap wiring 3. Verify that the supply cable is undamaged and rated for the current requirements of all connected devices. 4. Plug the prepared power cable into the 3-prong IEC inlet and a grounded AC power supply. Do not connect the fixture to a dimmer system. Setup 5 Rigging The MAC 250 and MAC 250+ include a clamp mounting bracket to which 1 or 2 rigging clamps (not included) can be bolted. The clamp mounting bracket fastens to the base as shown with 1/4-turn fasteners. Figure 2: Clamp mounting bracket WA R N I N G ! Always use an approved safety cable. The 1/4-turn fasteners are locked only when turned fully clockwise. 1. Verify that the clamps are in good condition and can bear at least 10 times the weight of the fixture. Bolt clamps to the bracket with a grade 8.8 (minimum) M12 bolt and lock nut, or as recommended by the clamp manufacturer, through the 13 mm holes in the clamp mounting bracket. 2. Align the clamp mounting bracket with any 2 key slots on the base. Insert both locking pins into the slots and turn both levers a full 1/4 turn clockwise to lock. 3. Verify that the structure can bear at least 10 times the weight of all installed fixtures, clamps, cables, auxiliary equipment, etc. 4. Working from a stable platform, clamp the fixture to the structure. 5. Install a safety cable that can bear at least 10 times the weight of the fixture securely to the structure and anchor the cable to the dedicated attachment point on the base. The attachment point is designed to fit a carabiner clamp. Connecting the serial data link The MAC 250 and MAC 250+ have locking 3-pin data input and output sockets that are wired for use with DMX devices, that is, pin 1 to shield, pin 2 to cold (-) and pin 3 to hot (+). As some devices have 5-pin connectors, or 3-pin connectors with reversed polarity on pins 2 and 3, the following adaptor cables may be required. 5-pin to 3-pin Adaptor Male 1 2 3 4 5 Female 1 2 3 3-pin to 5-pin Adaptor Male 1 2 3 Female 1 2 3 4 5 3-pin to 3-pin Phase-Reversing Adaptor Male 1 2 3 Female 1 2 3 P/N 11820005 P/N 11820004 P/N 11820006 Figure 3: Cable adaptors 1. Connect the controller's output to the fixture's data input. For a DMX controller with 5-pin output, use a cable with a 5-pin male and a 3-pin female connector, such as P/N 11820005. For a DMX controller with 3pin output, use a 3-pin cable such as the one included. For a Martin RS-485 protocol controller, use a phase reversing cable or reconfigure the pin-out as described on page 19. 2. Connect the output of the fixture closest to the controller to the input of the next fixture. When connecting a fixture with pin 3 hot to a fixture with pin 3 cold, use a phase-reversing adaptor. 3. To terminate the link, insert a male 120 XLR termination plug in the output of the last fixture. 6 MAC 250 and MAC 250+ Tips for building a serial link · Use shielded twisted-pair cable designed for RS-485 devices: standard microphone cable cannot transmit DMX data reliably over long runs. For links up to 300 meters (1000 ft.) long, you can use 24 AWG, low capacitance, 85-150 ohm characteristic impedance, shielded cable with 1 or more twisted pairs. For runs up to 500 meters (1640 ft.) use 22 AWG cable. Use an amplifier if the serial link exceeds 500 meters. Never use a "Y" connector to split the link. To split the serial link into branches use a splitter such as the Martin 4Channel Opto-Isolated RS-485 Splitter/Amplifier. Do not overload the link. Up to 32 devices may be connected on a serial link. Terminate the link by installing a termination plug in the output socket of the last fixture on the link. The termination plug, which is simply a male XLR connector with a 120 ohm, 0.25 watt resistor soldered between pins 2 and 3, "soaks up" the control signal so it does not reflect back down the link and cause interference. If a splitter is used, terminate each branch of the link. · · · Setup 7 section 3 C O N T RO L PAN E L You set the fixture address, mode, and personalities; read lamp hours, DMX values, and other information; calibrate effects, control the fixture manually, and run test and demo programs from the LED control panel. Functions that do not require feedback can also be performed remotely via the serial link using a Martin uploader. The display can be flipped for easy reading by pressing the [] and [] keys simultaneously. The intensity can be adjusted and the display can be set to black out 2 minutes after the last key-press. Menu navigation The DMX or Martin address, depending on the mode, and any error messages are displayed after the fixture resets. To enter the menu, press [MENU]. Use the [] and [] keys to move within the menu. To select a function or submenu, press [ENTER]. To escape a function or menu, press [MENU]. Address/ Messages AddR DMX MART PSET MOdE AUTO PERS PATI SWAP PINV TINV PTSP GTYP FTYP dLOF dRES ALON dISP dINT INFO HRS TOTL RSET L HR TOTL RSET L ST TOTL RSET VER CPU FEbA dISP TEST TSEQ DMXL STCO SHUT ... E SP PCb FACT UTIL UPLd dEMO MINP MAXP MINT MAXT FOCU GO MAN RST L ON LOFF SHUT dIM COL Rgob FOCU PRIS/ FROS PAN TILT AdJ RST L ON LOFF FEbA HEAd dIM COL Rgob FOCU PRIS PATI CAL P OF T OF d OF COOF RgOF FOOF dFOF STUd dMOd SCUT EFFb dMAC TRAC MOdE CAL dFSE FACT CUS1 CUS2 CUS3 Figure 4: MAC 250 and MAC 250+ menu 8 MAC 250 and MAC 250+ P e r s o n a l i t y s e t t i n g s ( P E R S) Personality Pan/tilt swap Path Options Effect (Default setting shaded, * indicates DMX override) Map DMX pan control to tilt channel and vice versa. Normal pan and tilt control. Reverse DMX pan control (right Æ left). Normal pan control (left Æ right). Reverse DMX tilt control (down Æ up). Normal tilt control (up Æ down). Optimize movement for speed.* Optimize movement for smoothness.* Select non-indexible gobos (MAC 250). Select indexible gobos (MAC 250+). Operate with rotating prism. Operate with optional frost (available soon). Enable DMX lamp off command. Disable DMX lamp off command.* Enable DMX reset command. Disable DMX reset command.* Lamp strikes automatically within 90 seconds of power on. Lamp remains off until "lamp on" command is sent. Display stays on. Display goes out 2 minutes after last key press. Adjust display intensity. Optimize effects for silence. Optimize effects for speed. Normal dimming curve. Simulated tungsten dimming curve. Color and gobo wheels turn the shortest direction.* Wheels turn same direction.* Enable feedback on color and gobo wheels. Disable feedback on color and gobo wheels. Enable DMX-selectable macros and pulsating effects. Disable DMX-selectable macros and pulsating effects. Absolute delta value algorithm (for most controllers) Real delta value algorithm Tracking samples. Increase if pan/tilt is not smooth. Select factory default personality settings. Save / load custom personality settings. To create a custom configuration, select S AVE after setting the personalities as desired. Select L OAd to recall the settings. ON PATI /SW AP OFF ON PATI/PINV OFF ON PATI/TINV OFF FAS T PTSP SLO W STd GTYP INd X PRI S FTYP FRO S ON dLOF OFF ON dRES OFF ON ALON OFF ON dISP OFF dINT STUd OFF NOR M dMOd TUN G ON SCUT OFF ON EFFb OFF ON dMAC OFF MOd 1 TRAC/MOdE MOd 2 TRAC/CAL 1-1 0 FAC T CUS 1 CUS 2 CUS 3 10-100 ON Pan inverse Tilt inverse Pan/tilt speed Gobo type Fixture type DMX lamp off DMX reset Automatic lamp on Display on/off Display intensity Studio mode Dimmer mode Shortcuts Effects feedback DMX macros Tracking algorithm Tracking samples Default settings dFSE Table 2: Personality settings Control Panel 9 Address and protocol selection Mode Movement speed Pan/tilt resolution Channels required 8 bit 9 DMX 1 Tracking DMX 2 16 bit 11 DMX 3 8 bit 11 DMX 4 16 bit 13 Martin Vector 16 bit 2 Tracking and/or Vector Table 3: Control modes The fixture address and operating mode must be selected before the MAC 250 or MAC 250+ will respond to the controller. DMX mode 4 provides full control and is recommended unless channels are limited. See "DMX-512 control" on page 12 for factors to consider when selecting other DMX modes. The address, also known as the start channel, is the first channel used to receive instructions from the controller. For independent control, each fixture must be assigned its own address and non-overlapping control channels. Two fixtures may share the same address only if they are to respond identically: they will receive the same instructions and individual control will not be possible. If automatic protocol detection (A UTO ) is O N, the fixture automatically switches to DMX or Martin mode after interpreting the control signal. This allows you to set the fixture up for both DMX and Martin controllers. If it is O FF, the default, the operating mode must match the controller. Note: automatic protocol detection does not detect the DMX mode (1, 2, 3, or 4) setup on the controller. 1. Apply power to the MAC 250 or MAC 250+. Press [MENU] on the control panel to enter the main menu. 2. Select A ddR using the arrow keys. Press [ENTER]. 3. Select DMX (to set a DMX address) or M ART (to set a Martin address) using the arrow keys. Press [ENTER]. 4. Select the address using the arrow keys. Press [ENTER]. Press [MENU] to return to the main menu. 5. Select P SET using the arrow keys. Press [ENTER]. 6. Select M OdE using the arrow keys. Press [ENTER]. 7. Select DM X1, DMX2 , DM X3, o r DMX 4 if using a DMX controller, or M ART if using a Martin 3032 controller. Press [ENTER]. 8. Press [MENU] to return to the main menu. Press [MENU] again to display the address. R e a d o u t s ( I N F O) Use the counters to track usage, maintenance intervals, lamp life, etc. To reset a counter, display the readout and press [] for 5 seconds. Counters showing totals are not resettable. H o u r s u s e d ( HR S) Read the total number of hours the fixture has been on (T OT L), and the number of hours on since the counter was last reset (R SE T). L a m p h o u r s ( L HR ) Read the total number of hours used with the lamp on (T O TL), and the number of lamp hours since the counter was last reset (R SET ). Reset this counter when installing a new lamp. L a m p s t r i k e s ( L ST) Read the total number of lamp strikes (T OT L), and the number of lamps strikes since the counter was last reset (R SE T ). Reset this counter when installing a new lamp. S o f t w a r e v e r s i o n ( VE R) Read the version number of the CPU software (C PU), feedback circuit software (F EB A), and display module software (d IS P). U t i l i t i e s ( U T I L) U p l o a d m o d e ( U PLd) Upload mode is normally engaged automatically by the uploader. In certain circumstances, however, you may have to set upload mode manually. See "Updating software" on page 19. 10 MAC 250 and MAC 250+ D e m o n s t r a t i o n p r o g r a m ( dEMO ) This menu offers a preprogrammed stand-alone demonstration. Before running the demo, set the minimum and maximum pan and tilt positions (M IN P, MAX P, MIN T, MAXT ) to a good location for viewing the effects. Select FOC U to focus the beam. Select G O to run the demo. Te s t p r o g r a m s ( T E S T) E f f e c t s t e s t s e q u e n c e ( TS EQ) Run a general test of all effects. D M X l o g ( DM XL) Read the DMX start code (S TC O) and DMX values received for each effect. This is an easy way to check that the DMX start code is 0 and that the expected DMX values are received. Q u a l i t y c o n t r o l a n d s e r v i c e t e s t s ( PCb, FA CT) These menus contain tests for factory and service use. M a n u a l c o n t r o l ( MA N ) The manual control menu permits you to do the following from the control panel: · · · · · · · · · reset the fixture (R ST ) turn the lamp on and off (L ON, Lo FF) open, close, and strobe the shutter at 3 speeds (S H UT) control the dimmer (d IM ) move the color wheel to each position and scroll it at 3 speeds (C OL ) move the gobo wheel to each position and rotate the gobos at 3 speeds (R g ob) control the focus (F OC U) insert and rotate the prism (P RIS ) at 3 speeds, or, if a frost filter is installed, insert the frost (F ROS) control pan and tilt (P AN, TIL T ) A d j u s t m e n t ( A d J) The adjustment menu provides the following functions: · · · · · · Reset the fixture (R ST ) Turn on and off the lamp (L O N, LoFF ) Disable pan/tilt feedback (F E bA) Control effects in the head (H EA d) Move the head to the home and extreme positions (P A TI) Calibrate effects (C A L) H e a d e f f e c t s a d j u s t m e n t ( HEAd ) The head submenu provides manual control when making mechanical adjustments, which should be performed by a qualified technician. It allows the technician to: · · · · Open, close, and strobe the dimmer/shutter (d I M) Move the color and gobo wheels through their positions (C OL , Rg ob) Move the focus lens to its extreme positions (F OCU ) Insert and rotate the prism (P RI S ) C a l i b r a t i o n ( CAL ) The calibration submenu allows you to adjust the effects to achieve total uniformity between fixtures: it is not a substitute for mechanical adjustment. To reset all calibrations to their factory defaults, select d FOF and press [ENTER] when SUR E is displayed, or press [MENU] to escape. 1. Select the effect to calibrate: pan (P O F), tilt (T OF ), dimmer/shutter (d O F), color wheel (C O F), rotatinggobo wheel (R gOF ), or focus (F OO F). 2. Adjust the effect using the arrow keys until it matches the other units when set at the same control value. Offsets are adjustable from 1 to 255. Press [ENTER] to save the calibration. Control Panel 11 section 4 OPERATION This section describes the effects and how personality settings affect their behavior. Selecting personalities from the control panel is described in the previous section. DMX-512 control The MAC 250 and MAC 250+ can be operated with DMX-512 controllers in 4 modes that combine vector and/or tracking control with 8-bit or 16-bit pan/tilt resolution. Tr a c k i n g c o n t r o l With tracking control, the speed at which effects move is set by programming a cross-fade time on the controller. The controller divides the move into steps and updates the fixture with small changes at the rate required to achieve the fade. The fixture tracks the changes and averages them with a digital filter algorithm to provide smooth movement at all speeds. This algorithm is adjustable to compensate for controllers that calculate position changes unevenly. In most cases the default settings work well. If movement is not satisfactory there are 2 parameters that can be adjusted. The first is the calculation method used and is selected under PE RS/ TRA C/M OdE. MOd 1, the default, calculates speed based on the absolute value of the change in DMX; it is the best choice with controllers that calculate intermediate positions that are close to the line of travel. MOd 2 uses the real value of the DMX delta to calculate speed and is better if the intermediate positions stray significantly from the line of travel. The second parameter is the number of position updates used to calculate speed. The level is adjustable between 1 and 10 under PE RS/ TRAC /CA L. Increasing the number of samples increases the distance over which speed is calculated, making movement smoother but less responsive to sudden changes. The ideal settings for both parameters will vary from controller to controller: experiment for best results. Ve c t o r c o n t r o l With vector control, you set the speed on a speed channel. This provides a way to control speed on controllers without cross-faders. Vector control also provides smoother movement, particularly at slow speeds, with controllers that send slow or irregular tracking updates, plus a "blackout speed" and overrides of the shortcut and pan/tilt speed personality settings. When using vector speed, the cross-fade time must be 0. Tracking control can be enabled in vector mode by setting one or both of the speed channels to "tracking speed." 8-bit versus 16-bit pan/tilt resolution With 8-bit pan/tilt resolution, pan and tilt are divided into 256 equal increments. Finer position control and smoother movement are provided in 16-bit mode, which divides pan into 40,192 positions and tilt into 43,008 positions. Mar tin RS-485 con trol The MAC 250 is fully supported by the Martin 3032 controller with version 2.05 or higher software. The MAC 250+ may be set up on the 3032 as a MAC 250: gobo indexing, however, is not supported. To respond to the 3032, Martin mode must be selected or automatic protocol detection must be enabled as described on page 10. Controllable effects All mechanical effects are reset to a home position when the fixture is powered up. They can also be reset via DMX. Accidental resets can be prevented by turning DMX Reset (P ERS /dR ES ) off. An on-the-fly position correction system automatically corrects the position of the color and gobo wheels; this feature can be disabled by turning Effects Feedback (P E RS/ EFFb ) off. General operation may be optimized for speed or quietness with the Studio Mode setting (P ER S/S TUd). Lamp With the default setting, the lamp remains off until a "lamp on" command is sent from the controller. Note: A peak of electric current that can be many times the operating current is drawn for an instant when striking a discharge lamp. Striking many lamps at once may cause a voltage drop large enough to prevent lamps from striking or draw enough 12 MAC 250 and MAC 250+ current to trip circuit breakers. If sending "lamp on" commands to multiple fixtures, program a sequence that strikes lamps one at a time at 5 second intervals. The fixture automatically strikes the lamp within 90 seconds of being powered on if the Automatic Lamp On setting (P ER S/AL ON ) is turned on. A delay determined by the fixture address staggers lamp strikes to prevent excessive voltage drop and current draw. The lamp can be turned off from the controller. Note: the lamp cannot be restruck for 8 minutes after being turned off. Accidental "lamp off" commands can be prevented by turning the DMX Lamp Off setting (P ER S/d LOF) off. Color . Position 1 2 3 4 5 6 7 8 9 10 11 12 Color CTC Yellow 603 Blue 104 Pink 312 Green 206 Blue 108 Red 301 Magenta 507 Blue 101 Orange 306 Green 202 Purple 502 MAC 250+ color wheel shown Table 4: Color positions The MAC 250 and MAC 250+color wheel provides a 5500 to 2900K color temperature correction (CTC) filter and 11 dichroic color filters. The wheel can be scrolled continuously - allowing for split color effects - or in steps, and rotated randomly or continuously in both directions at different speeds. The Shortcuts setting (P E RS/S CUT ) determines whether or not the wheel takes the shortest path to the next position; this setting may be overridden on the speed channel in vector mode. Setting the effects speed to "blackout" causes the shutter to black out the light while the wheel is moving. The color filters on the MAC 250+ are interchangeable. See page 16. Rotating gobos . Position 1 2 3 4 5 6 7 8 Gobo Radial Dashes Line of Beams Fan Hat Triple Beam Decentered Beam Fibroid Random Holes, Blue Psycho Circles, Magenta Table 5: Gobo positions The MAC 250 and MAC 250+ has 8 rotating gobo positions plus an open position. Each gobo rotates and/or "shakes" at varying speeds. Gobos and shake are selected on channel 4; rotation is set on channel 5. The gobo wheel also rotates continuously in both directions at variable speed. Operation 13 The MAC 250+ provides gobo indexing as well. Select the gobo on channel 4, between the DMX values of 5 and 44, and set the position on channel 5. The gobo type setting (P ERS /GTY P) automatically defaults to IN dX in the MAC 250+ to enable this feature. It defaults to S Td in the MAC 250. The Shortcuts setting (P E RS/S CUT ) determines whether or not the wheel takes the shortest path to the next position; this setting may be overridden on the effects speed channel. Setting the speed to "blackout" causes the shutter to black out the light while the wheel turns. To change the gobos, see "Rotating gobos" on page 15. Dimmer / shutter The mechanical dimmer/shutter system provides full, high-resolution dimming, "instant" open and blackout, random and variable strobe effects, and random and variable pulses in which the dimmer snaps open and slowly dims or snaps closed and slowly opens. Pulse and random strobe effects can be disabled by switching DMX Macros (P ER S/ dMA C) off. The Dimmer Mode (P ER S / dMO d) setting allows you to select between linear or simulated tungsten fade curves. The fade time must be 0 to simulate tungsten dimming. Focus The beam may be focused from approximately 2 meters (6.5 feet) to infinity. The MAC 250's default beam angle is 17.5°; see page 17 for additional options. The MAC 250+ has a different optical system that uses achromatic lenses. It provides a beam angle of 18.3°. Rotating prism The 3-facet prism rotates in both directions at varying speeds. There are 8 preprogrammed macros that combine prism and gobos. These can be disabled by switching DMX Macros (P E RS/d MAC ) off. Setting the speed to "blackout" causes the shutter to black out the light while the prism moves in and out. Pa n a n d til t The yoke pans 540° and the head tilts 289°. Movement may be optimized for speed by setting the pan/tilt speed setting (P ER S / PTSP ) to FAS T, or for smoothness by setting it to SLOW. This setting may be overridden on the speed channel in vector mode. Setting the speed to "blackout" causes the shutter to black out the light while the head is moving. The pan and tilt channels can be inverted and/or swapped using the pan/tilt menu (P E RS / PAT I ). 14 MAC 250 and MAC 250+ section 5 BASIC SERVICE The MAC 250 and MAC 250+ operate under challenging conditions presented by heat, humidity, dust, and touring. Excessive dust, grease, and smoke fluid buildup degrades performance and causes overheating and damage that is not covered by the warranty. The MAC 250 and MAC 250+ require regular maintenance to keep performing at their peak. The schedule will depend on the application and should be discussed with your Martin distributor. Refer any service that you are not qualified to perform to a professional technician. WARNING! Removing covers exposes dangerous live electrical circuits, hot surfaces, and a lamp under high pressure. Procedures requiring the removal of any cover shall be performed by professional users or technicians only. Disconnect the fixture from AC power and allow it to cool before removing any cover. Replacing the lamp If the lamp becomes difficult to strike, it probably needs to be replaced. To reduce the risk of lamp explosion, which may damage the fixture, do not exceed the lamp's rated life (2000 hours) by more than 25 percent. Refer to page 5 for the lamp replacement procedure. After installing the lamp, reset the lamp usage counters as described on page 10. Optimizing reflector alignment The reflector is aligned at the factory. Due to differences between lamps, however, fine adjustment may improve performance. 1. Strike the lamp and focus the light on a flat surface. 2. See Figure 1 on page 4. Center the hot-spot (the brightest part of the beam) by turning the 3 adjustment screws one at a time with a 3 mm Allen wrench. If there is no hot-spot, adjust the reflector until the light is even. 3. To reduce a hot-spot, "push" the reflector out by turning all 3 screws counterclockwise 1/4-turn at a time until the light is evenly distributed. 4. If the light is brighter around the edge than it is in the center, or if light output is low, the lamp is too far back in the reflector. "Pull" the reflector in by turning the screws clockwise 1/4-turn at a time until the light is bright and evenly distributed. Figure 5 Rotating gobos Custom glass gobos for the MAC 250 and MAC 250+ should be made with any non-reversible graphics true on the coated side. Complete gobo specifications are listed on page 27. Do not use chrome-coated glass gobos: they absorb more heat than enhanced aluminum gobos and are likely to break or oxidize. Changing gobos 1. Disconnect the fixture from AC power and allow it to cool. Remove the top head shell as shown in Figure 5. 2. Turn the gobo wheel until the gobo lines up with the access hole. Squeeze the ends of the retention spring together and remove. Push the gobo out from the back. 3. Insert the new gobo. See Figure 7 for proper orientation. 4. Replace the gobo retention spring. Figure 6 Basic Service 15 Gobo orientation Figure 7 shows the correct orientation for different gobo types. When in doubt, install gobos with the more reflective side towards the lamp. Coated side towards lamp Coated Glass Gobos Uncoated side towards stage When an object is held up to the coated side there is no space between the object and its reflection. The back edge of the gobo cannot be seen when looking through the coated side. When an object is held up to the uncoated side there is a space between the object and its reflection. The back edge of the gobo can be seen when looking through the uncoated side. Textured Glass Gobos Smooth side towards lamp Textured side towards stage Reflective side towards lamp Metal Gobos Black side towards stage True image towards lamp Image/text Gobos Reversed image towards stage Figure 7: Gobo orientation C h a n g i n g c o l o r f i l t e r s ( M AC 2 5 0 + o n l y ) 1. Disconnect the fixture from AC power and allow it to cool. 2. Remove the top head shell as shown in Figure 5. 3. Turn the color wheel so the desired color filter is in front of the access hole. Press the filter forwards slightly to release it and then grasp it by the edges and remove. 4. To insert a filter, slide it under the retention spring until it snaps into place. 5. Replace the top head shell. Figure 8 16 MAC 250 and MAC 250+ C o n f i g u r i n g t h e o p t i c a l s y s t e m ( M AC 2 5 0 o n l y ) Beam angle options The standard MAC 250 lens system can be configured for 4 beam angles ranging from 12.1° to 23.3°. The beam angle in the default 4-lens configuration is 17.5°. Other beam angles are achieved by removing lenses and positioning the dimmer module as shown below. Note: dimming will be somewhat less even in the 12.1° configuration. To calculate the projected size of an image, divide the gobo's image diameter by the focal length and then multiply by the distance in meters. 12.1° 14.6° 17.5° 23.3° 2 34 1 34 12 34 12 4 Figure 9: MAC 250 optical configurations Beam Angle 12.1° 14.6° 17.5° 23.3° Focal Length 80.2 mm 66.3 mm 55.2 mm 41.2 mm Remove Lens 1 (40 mm) 2 (50 mm) 3 (60 mm) Dimmer Position forward forward rear rear Table 6: MAC 250 optical configurations Changing beam angle Verify that lenses and retention springs are fully seated. 1. Disconnect the fixture from AC power and allow it to cool. 2. Remove the top head shell as shown in Figure 5. 3. Remove and/or replace lenses as required. To remove lens 1, first remove lens 2 as described next. Then pull out the retention spring for lens 1 and tilt the module or head until the lens drops out. Catch it in a soft cloth. Store the lens together with the spring in a safe place. Replace lens 2 and the module(s). To remove lens 2, remove either the color/gobo/focus module or the dimmer and prism modules as described below. Pull out the retention spring for lens 2 and tilt the module or head until the lens drops out. Catch it in a soft cloth. Store the lens together with the spring in a safe place. Replace the module(s). To remove lens 3, pull the lens clip back. Tilt the head until the lens drops out and catch it with a soft cloth. Store the lens together with the spring in a safe place. 4. Move the dimmer module to the forward or rear position as indicated in Figure 9. Make sure as you position the module that the bottom sits between the guide pins in the bottom shell. Pull the locking pins up and then snap them down to lock. 5. Replace the head cover. Position the holes by the lens opening over the nipples and check that all wires are inside the head as you lower the cover into place. Push the locking pins in with a flat-tip screwdriver and turn them clockwise until they lock (1/2 turn). Basic Service 17 Removing modules Color/gobo/focus module 1. Disconnect the fixture from AC power and allow it to cool. 2. Remove the top head shell as shown in Figure 5. 3. MAC 250: Unplug the wires from the color and gobo wheel sensors and the 3 top motors. MAC 250 +: Unplug the wires from the color wheel sensor and the 3 top motors. Unplug the outside connector from the junction print behind the gobo wheel. 4. Pull up the 2 plastic locking pins to release the module. Move the starter wires aside and lift the module partially out. Unplug the wires from the bottom motor. Dimmer module 1. Disconnect the fixture from AC power and allow it to cool. 2. Remove the top head shell as shown in Figure 5. 3. Note whether the module is in the forward or rear position. (The MAC 250 + gives best results with the dimmer in the forward position.) 4. Unplug the wires from the top dimmer motor. Pull up the 2 plastic locking pins to release the module. Unplug the wires from the bottom motor. Prism module 1. Disconnect the fixture from AC power and allow it to cool. 2. Remove the top head shell as shown in Figure 5. 3. Remove the dimmer module. 4. Pull the 2 plastic locking pins to release the prism module. Lift the module partially out and unplug the wires from motors. Cleaning Optical components Use care when cleaning optical components. The surface on dichroic filters is achieved by means of special multi-layer coatings and even small scratches may be visible. Residues from cleaning fluids can bake onto components and ruin them. 1. Allow the components to cool completely. 2. Wash dirty lenses and filters with isopropyl alcohol. A generous amount of regular glass cleaner may also be used, but no residues may remain. 3. Rinse with distilled water. Mixing the water with a small amount of wetting agent such as Kodak Photoflo will help prevent streaking and spotting. 4. Dry with a clean, soft and lint-free cloth or blow dry with compressed air. Fans To maintain adequate cooling it is important that the fans be cleaned of dust and dirt periodically. Use a soft brush, vacuum, or compressed air. Lubrication Use silicone lubricant, Martin P/N 37302003 (500 ml) or P/N 37302004 (200 ml, in applicator bottle). No other lubricant is approved for use. When applying lubricant, always remove excess and do not get oil on other parts. Check the focus mechanism when the head is open and apply a drop of lubricant to the 3 metal slides if movement is rough. Lubricate the rotating-gobo bearings if movement is rough on slow rotation or if they become noisy. Apply a few drops of oil to each bearing from the lamp side of the wheel. 18 MAC 250 and MAC 250+ Replacing fuses Po w e r s u p p ly f u s e s The fuses for each of the 3 low-voltage power supplies are located on the printed circuit board. If one of the circuit board LEDs does not light, one of these fuses may be blown. 1. Disconnect the fixture from AC power. Remove the 2 Philips screws from the plastic cover on the arm opposite the side with the visible motor and pull off the cover. 2. Locate and replace the defective fuse with one of the same rating. The fuses are shown on the PCB layout diagram; their values are listed on page 27. 3. Replace the cover before applying power. Main fuse The main fuse holder is built in to the mains input socket. Never replace the fuse with one of a different rating! 1. Unplug the mains cable from the input socket. 2. Pry open the fuse holder and remove the fuse. 3. Replace the fuse with one of the same type and rating. The fuse rating is listed on serial number label. 4. Close the fuse holder and replace the mains cable. Changing the XLR pin-out The signal polarity of pins 2 and 3 on the XLR connectors can be reversed, allowing the fixture to be connected directly to Martin devices wired with pin 3 cold (-). Optionally, a phase-reversing cable may be used. 1. Disconnect the fixture from AC power. Remove the 2 Philips screws from the plastic cover on the arm opposite the side with the visible motor and pull off the cover. PL234 PL233 PL234 PL233 Martin pin-out DMX pin-out (default) Figure 10: XLR jumpers 2. Position the jumpers on PL 233 and PL 234 for the desired XLR pin-out as shown. 3. Replace the cover before applying power. Updating software The MAC 250 and MAC 250+ operate with the same software. Updates are available from your Martin dealer and the Martin Professional web site. Please read the update notes included with the software. Note: the software automatically defaults to the correct gobo type setting (P ERS /GT YP) in unmodified fixtures. Normal upload Update software is uploaded to the MAC 250 and MAC 250+ using a Martin uploader such as the MPBB1. The uploader is connected to the fixture just like a controller. Under normal conditions, software can be installed from a remote location - there is no need to set the MAC 250 and MAC 250+ to boot mode. Please refer to the uploader manual for further instructions. Boot mode upload If the data is corrupted during transmission, a check-sum error (C S ER) occurs and after 15 seconds the fixture switches to boot mode (U PLd) and is ready for a boot mode upload as described in the uploader manual. If a software upload is interrupted, the fixture must be turned off for at least 10 seconds before a new upload can be attempted. When powered on, a check-sum error occurs and the fixture goes into boot mode, ready for a second upload attempt. Select boot mode upload on the uploader. If there is no functional software in memory, the fixture must be set to boot mode manually. If the control panel works, select UP Ld from the U TIL menu and confirm when S URE is displayed by pressing [ENTER]. Basic Service 19 If the control panel does not work, boot mode can be engaged by moving jumper PL121 on the main circuit board to pins 1 and 2 as follows. 1. Disconnect the fixture from AC power. Remove the plastic cover from the arm opposite the side with the visible motor. 2. Move jumper PL121 to pins 1 and 2 (hard boot setting). See also the diagram on page 26. PIN 1 È PL121 PIN 1 È PL121 normal setting hard boot setting Figure 11: Hard boot jumper 3. Perform a boot-mode upload as described in the uploader manual. 4. Disconnect the fixture from AC power. Move the hard boot jumper back to the normal setting and replace the cover. C h a n g i n g vo l t ag e a n d f r e q u e n cy s e t t i n g s Local AC Voltage 95 - 110 V 110 - 130 V 200 - 220 V 220 - 240 V 240 - 260 V 50 Hz Setting 100 V, 50 Hz 120 V, 50 Hz 210 V, 50 Hz 230 V, 50 Hz 250 V, 50 Hz 60 Hz Setting 100 V, 60 Hz 120 V, 60 Hz 210 V, 60 Hz 230 V, 60 Hz 250 V, 60 Hz Maximum power (watts) 350 350 370 360 370 Maximum current (amps) 4.1 3.2 2.2 1.8 1.7 Table 7: Power supply settings and consumption If the factory voltage and frequency setting, shown on the serial number label, does not match local conditions, rewire the fixture as follows. 1. Disconnect the fixture from AC power. Remove the top base cover closest to the power inlet. 2. Find the correct setting for your AC voltage and frequency in Table 7. 3. Locate the 7-terminal connection block inside the base. Move the blue wire to the 0 or 20 V terminal, the brown wire to the 120, 230, or 250 V terminal; and the black wire to the 50 or 60 Hz terminal as shown for each setting in Figure 12. 0V BLUE 20 V 120 V BROWN 230 V 250 V 60 Hz 50 Hz BLACK 0 V BLUE 20 V 120 V BROWN 230 V 250 V 60 Hz 50 Hz BLACK 0V BLUE 20 V 120 V BROWN 230 V 250 V 60 Hz 50 Hz BLACK 0V 20 V 120 V 230 V BROWN 250 V 60 Hz 50 Hz BLACK 0 V BLUE 20 V 120 V 230 V 250 V BROWN 60 Hz 50 Hz BLACK BLUE 100 V / 50 Hz 0V BLUE 20 V 120 V BROWN 230 V 250 V BLACK 60 Hz 50 Hz BLUE 120 V / 50 Hz 0V 20 V BROWN 120 V 230 V 250 V BLACK 60 Hz 50 Hz 210 V / 50 Hz 0V BLUE 20 V 120 V BROWN 230 V 250 V BLACK 60 Hz 50 Hz 230 V / 50 Hz 0 V BLUE 20 V 120 V 230 V BROWN 250 V BLACK 60 Hz 50 Hz BLUE 250 V / 50 Hz 0V 20 V 120 V 230 V BROWN 250 V BLACK 60 Hz 50 Hz 100 V / 60 Hz 120 V / 60 Hz 210 V / 60 Hz 230 V / 60 Hz 250 V / 60 Hz Figure 12: Voltage and frequency settings 20 MAC 250 and MAC 250+ section 6 APPENDIXES DMX protocol DMX1 DMX2 DMX3 DMX4 Value 0 - 19 20 - 49 50 - 72 73 - 79 80 - 99 100 - 119 120 - 127 128 - 147 148 - 167 168 - 187 188 - 190 191 - 193 194 - 196 197 - 199 200 - 202 203 - 207 208 - 217 218 - 227 228 - 237 238 - 247 248 - 255 0 - 255 Percent 0-7 8 - 19 20 - 28 29 - 31 31 - 39 39 - 47 47 - 50 50 - 58 58 - 65 66 - 73 74 - 75 75 - 76 76 - 77 77 - 78 78 - 79 80 - 81 82 - 85 85 - 89 89 - 93 93 - 97 97 - 100 0 - 100 Function Shutter, Strobe, Reset, Lamp On/Off Shutter closed Shutter open Strobe, fastÆslow Shutter open Opening pulse, fast Æslow Closing pulse, fast Æslow Shutter open Random strobe, fast Random strobe, medium Random strobe, slow Shutter open Random opening pulse, fast Random opening pulse, slow Random closing pulse, fast Random closing pulse, slow Shutter open Reset fixture, see note 1 Shutter open Lamp on Shutter open Lamp off: time > 5 seconds, see note 2 Dimmer Closed Æ open Color Continuous Scroll: full color positions: White CTC Yellow 603 Blue 104 Pink 312 Green 206 Blue 108 Red 301 Magenta 507 Blue 101 Orange 306 Green 202 Purple 502 Stepped Scroll Purple 502 Green 202 Orange 306 Blue 101 Magenta 507 Red 301 Blue 108 Green 206 Pink 312 Blue 104 Yellow 603 CTC White Continuous Rotation CW, fast Æ slow CCW, slow Æ fast Random color Fast Medium Slow 1 1If DMX Reset is disabled in the menu, a reset command can only be executed if the CTC filter is selected, the prism is on (not rotating) and the open gobo is selected. 2 If DMX Lamp Off is disabled in the menu, a lamp off command can only be executed if the CTC filter is selected, the prism is on (not rotating) and the open gobo is selected. 2 0 12 24 36 48 60 72 84 96 108 120 132 144 0 5 9 14 19 23 28 33 37 42 47 42 56 3 156 - 159 160 - 163 164 - 167 168 - 171 172 - 175 176 - 179 180 - 183 184 - 187 188 - 191 192 - 195 196 - 199 200 - 203 204 - 207 61 - 63 63 - 64 64 - 65 66 - 67 67 - 68 69 - 70 70 - 72 72 - 73 74 - 75 75 - 76 77 - 78 78 - 79 80 - 81 208 - 226 227 - 245 82 - 88 89 - 96 246 - 248 249 - 251 252 - 255 96 - 97 98 - 98 99 - 100 Appendixes 21 DMX1 DMX2 DMX3 DMX4 Value 0-9 10 - 19 20 - 29 30 - 39 40 - 49 50 - 59 60 - 69 70 - 79 80 - 89 Percent 0-3 4-7 8 - 11 12 - 15 16 - 19 19 - 23 23 - 27 27 - 31 31 - 35 Function Gobo selection and shake Open gobo Gobo 1 Gobo 2 Gobo 3 Gobo 4 Gobo 5 Gobo 6 Gobo 7 Gobo 8 Shake Gobo 8 slow Æ fast Gobo 7 slow Æ fast Gobo 6 slow Æ fast Gobo 5 slow Æ fast Gobo 4 slow Æ fast Gobo 3 slow Æ fast Gobo 2 slow Æ fast Gobo 1 slow Æ fast Continuous rotation CW slow Æ fast CCW fast Æ slow Gobo selection and shake Indexing: set position on channel 5 Open gobo Gobo 1 Gobo 2 Gobo 3 Gobo 4 Gobo 5 Gobo 6 Gobo 7 Gobo 8 Rotation: set velocity on channel 5 Open gobo Gobo 1 Gobo 2 Gobo 3 Gobo 4 Gobo 5 Gobo 6 Gobo 7 Gobo 8 Rotation with shake, slow Æ fast: set velocity on ch. 5 Gobo 8 Gobo 7 Gobo 6 Gobo 5 Gobo 4 Gobo 3 Gobo 2 Gobo 1 Continuous scroll: set velocity of gobo rotation on ch. 5 CW slow Æ fast CCW fast Æ slow Gobo rotation (select gobo on channel 4) Index position 0 - 395° (only if gobo type = indexed) Continuous rotation (direction and speed) No rotation CW, slow Æ fast CCW, fast Æ slow No rotation 4 if gobo type = standard 90 - 104 105 - 119 120 - 134 135 - 149 150 - 164 165 - 179 180 - 194 195 - 209 35 - 41 41 - 47 47 - 52 53 - 59 59 - 64 65 - 70 70 - 76 76 - 82 210 - 232 233 - 255 82 - 91 91 - 100 0-4 5-9 10 - 14 15 - 19 20 - 24 25 - 29 30 - 34 35 - 39 40 - 44 0-1 1-3 3-5 6-7 7-9 9 - 11 11 - 13 13 - 15 15 - 17 4 if gobo type = indexed 45 - 49 50 - 54 55 - 59 60 - 64 65 - 69 70 - 74 75 - 79 80 - 84 85 - 89 17 - 19 19 - 21 21 - 23 23 - 25 25 - 27 27 - 29 29 - 31 31 - 33 33 - 35 90 - 104 105 - 119 120 - 134 135 - 149 150 - 164 165 - 179 180 - 194 195 - 209 35 - 40 41 - 46 47 - 52 53 - 58 59 - 64 65 - 70 70 - 76 76 - 82 210 - 232 233 - 255 82 - 91 91 - 100 0 - 255 5 0-2 3 - 127 128 - 252 253 - 255 0 - 100 0-1 1 - 50 50 - 98 99 - 100 22 MAC 250 and MAC 250+ DMX1 DMX2 6 DMX3 DMX4 Value 0 - 255 0 - 19 20 - 79 80 - 89 90 - 149 150 - 215 Percent 0 - 100 0-7 8 - 31 31 - 35 35 - 58 59 - 84 Focus Infinity Æ 2 meters Function Prism Prism off Rotating prism, CCW fast Æ slow No rotation Rotating prism, CW slow Æ fast Prism off Prism/Gobo Macros Macro 1 Macro 2 Macro 3 Macro 4 Macro 5 Macro 6 Macro 7 Macro 8 Pan Left Æ right (128 = neutral) Pan Fine (LSB) Left Æ right Tilt Up Æ down (128 = neutral) Tilt Fine (LSB) Up Æ down Pan/Tilt Speed Tracking Fast Æ slow Tracking, PTSP NORM (menu override) Tracking, PTSP FAST (menu override) Blackout while moving Effects Speed Dimmer, focus Tracking mode Fast Æ slow Tracking Maximum speed Color Tracking mode Speed, fast Æ slow Tracking, SCUT OFF (menu override) Tracking, SCUT ON (menu override) Blackout while moving Gobo selection Normal (no blackout) Normal, SCUT OFF (menu override) Normal, SCUT ON (menu override) Blackout while moving Indexed gobo rotation (only if gobo type = indexed) Tracking mode Fast Æ slow Tracking Blackout while moving Prism Normal (no blackout) Blackout while moving 7 216 - 220 221 - 225 226 - 230 231 - 235 236 - 240 241 - 245 246 - 250 251 - 255 0 - 255 9 9 10 11 0 - 255 0 - 255 0 - 255 0-2 3 - 245 246 - 248 249 - 251 252 - 255 84 - 86 87 - 88 89 - 90 91 - 92 93 - 94 95 - 96 96 - 98 98 - 100 0 - 100 0 - 100 0 - 100 0 - 100 0-1 1 - 96 96 - 97 98 - 98 99 - 100 8 9 9 10 11 - - 10 12 0-2 3 - 245 246 - 251 252 - 255 0-1 1 - 96 96 - 98 99 - 100 0-2 3 - 245 246 - 248 249 - 251 252 - 255 11 13 0 - 245 246 - 248 249 - 251 252 - 255 0-1 1 - 96 96 - 97 98 - 98 99 - 100 0 - 96 96 - 97 98 - 98 99 - 100 0-2 3 - 245 246 - 251 252 - 255 0-1 1 - 96 96 - 98 99 - 100 0 - 251 252 - 255 0 - 98 99 - 100 23 MAC 250 and MAC 250+ Error messag es Display readout AUTO (Automatic protocol detection error) LERR (Lamp error) Appears if... Automatic protocol detection is enabled and there is no control input. What to do · Verify that controller is connected properly and sending data. ... the lamp doesn't ignite within 10 min- · Check the lamp utes of receiving the `Lamp ON' com· Check voltage and frequency settings mand. ...the EEPROM memory cannot be read. ...a software upload is unsuccessful. ... there is no communication between the control panel and motherboard. This appears briefly when switching on the fixture. ... the fixture detects the lamp is ON but no `Lamp ON' command has been received. This can occur if the lamp relay is stuck. ... you attempt to strike the lamp within 8 minutes after having switched it off. The fixture will store the `Lamp ON' instruction and strike the lamp once the 8 minutes period has elapsed. ...pan (FbEp), tilt (FbET) or both (FbER) feedback circuits are malfunctioning. · Contact service technician. · Reload software, see page 20. · Check fuses. · Check cable between control panel and motherboard. · Reinstall software. · Contact service technician. · The fixture may be operated but remote lamp on/off may be effected. · Contact service technician. · Wait until the lamp strikes. MERR (Memory error) CSER (Check-sum error) **** ShER (Short error) Hot (Hot lamp) FbEP (Feedback error pan) FbET (Feedback error tilt) FbER (Feedback error pan/tilt) · The fixture will still operate, though with reduced maximum speed to prevent the fixture from losing track of its position. · Contact service technician. · After the time-out the fixture will work normally. · Contact service technician. PAER (Pan time-out) TIER (Tilt time-out) COER (Color wheel time-out) RgER (Rot. gobo time-out) ...the pan or tilt indexing circuit is malfunctioning. ...the magnetic-indexing circuit malfunc- · After the time-out, the effect in questions (e.g. sensor defective or magnet tion stops in a random position. missing). · Contact service technician. Appendixes 24 Tr o u b l e s h o o t i n g Problem Probable cause(s) No power to fixture. One or more of the fixtures is completely dead. Primary fuse blown. Secondary fuse(s) blown (located on PCB inside base). Fixtures reset correctly but all respond erratically or not at all to the controller. The controller is not connected. XLR pin-out of the controller does not match pin-out of the first fixture on the link (i.e. signal is reversed). Bad data link connection Data link not terminated with 120 termination plug. Fixtures reset correctly but some respond erratically or not at all to the controller. Incorrect addressing of the fixtures. One of the fixtures is defective and disturbs data transmission on the link. Remedy Check that power is switched on and cables are plugged in. Replace fuse. Check fuses on PCB and replace. Connect controller. Install a phase-reversing cable between the controller and the first fixture on the link. Inspect connections and cables. Correct poor connections. Repair or replace damaged cables. Insert termination plug in output jack of the last fixture on the link. Check address and protocol settings. Bypass one fixture at a time until normal operation is regained: unplug both connectors and connect them directly together. Have the defective fixture serviced by a qualified technician. Install a phase-reversing cable between the fixtures or swap pins 2 and 3 in the fixture that behaves erratically. Disable effects feedback. Contact Martin technician for service. XLR pin-out on fixtures does not match (pins 2 and 3 reversed). Magnetically indexed effect resets correctly but wanders after fixture reaches operating temperature. No light and "LERR" error message displayed. Effect wheel or magnetic sensor requires mechanical adjustment. The ballast and transformer settings do not match local AC voltage and frequency. Lamp missing or blown Fixture is too hot.

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Diplodocs provides you a fast and easy access to the user manual MARTIN MAC 250+.

MARTIN offer a product for which we do not have the user manual? Let us know what you are looking for: user guide, owner's manual, online manual, operating instructions, quick start guide, mounting instructions, schematics, service manual, installation instructions, RTFM.

Diplodocs allows you to download user manual MARTIN MAC 250+, user guide MARTIN MAC 250+, instructions MARTIN MAC 250+, owner's manual MARTIN MAC 250+, online manual MARTIN MAC 250+.


MARTIN MAC 250+, ,
Include the add-on to download manuals from your site, forum or blog Frequently Asked Questions Contact Diplodocs team Last searches
Last additions
Sitemap
Brands starting with A B C D E F G H I J K L M N O P Q R S T U V W X Y Z #
Copyright © 2005 - 2008 - Diplodocs - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.