|
5 600 brands
1 870 000 user's guides |
|
|
|||||||||||||||
|
Search a brand
Advanced Search
Where is my user guide?
|
Our partners wish to propose you the following products
|
User manual MAXDATA PLATINUM 200I M7
Diplodocs help download the user guide MAXDATA PLATINUM 200I M7.
This product, although classified under the brand MAXDATA, may have been manufactured by BELINEA after mergers, acquisitions, or a change in name.
Preview of the first 3 pages of manual
You either have JavaScript turned off or an old version of Adobe Flash Player Get the latest Flash Player.
User guide MAXDATA PLATINUM 200I M7
Detailed instructions for use are in the User's Guide. MAXDATA PLATINUM 200 I M7
User's Manual
2
Contents
Contents
1 Setting up the System 5
Safety Information ...................................................................................................................................5 Server Position ...................................................................................................................................5 System Access Warnings ..................................................................................................................6 Rack Mount Warnings ........................................................................................................................6 Powering up the System .........................................................................................................................7
2 Board Features
9
Connector and Header Locations ..........................................................................................................10 Configuration Jumpers ..........................................................................................................................11 Back Panel Connectors .........................................................................................................................12 Hardware Requirements .......................................................................................................................13 Memory ............................................................................................................................................13
3 Hardware Installations and Upgrades
15
Before You Begin ..................................................................................................................................15 Tools and Supplies Needed ..............................................................................................................15 Installing and Removing Memory ..........................................................................................................15 Installing DIMMs ..............................................................................................................................15 Replacing the Backup Battery ...............................................................................................................17
4 Server Utilities
19
Using the BIOS Setup Utility .................................................................................................................19 Starting Setup...................................................................................................................................19 If You Cannot Access Setup.............................................................................................................19 Setup Menus ....................................................................................................................................19 Clearing the CMOS ...............................................................................................................................21 Configuring the System for embedded Serial ATA RAID ......................................................................22 Configuring the BIOS .......................................................................................................................22 Creating your RAID set.....................................................................................................................22 Loading the RAID Drivers .................................................................................................................22
5 Rack Installation
23
Parts List ..............................................................................................................................................23 Installation .............................................................................................................................................24
6 Regulatory and Compliance Information
27
Product Regulatory Compliance ............................................................................................................27 Product Safety Compliance ..............................................................................................................27 Product RoHS Compliance ...............................................................................................................27 Product EMC Compliance ...............................................................................................................27 Product Regulatory Compliance Markings .......................................................................................27 Electromagnetic Compatibility Notices .................................................................................................27 Europe (CE Declaration of Conformity) ............................................................................................27
MAXDATA PLATINUM 200 I M7
3
Figures
1. 2. 3. 4. 5. 6. 7. PLATINUM 200 I Controls .................................................................................................................7 Board Connector and Component Locations ..................................................................................10 Configuration Jumpers ....................................................................................................................11 Back panel Connectors ...................................................................................................................12 Installing DIMMs .............................................................................................................................15 Removing the Battery .....................................................................................................................18 Clearing the CMOS .........................................................................................................................21
Tables
1. 2. 3. 4. 5. 6. 7. Feature Summary ..............................................................................................................................9 Board Connectors and Components ...............................................................................................10 Configuration Jumpers ....................................................................................................................11 Back panel Connectors ...................................................................................................................12 NIC LEDs .........................................................................................................................................12 Keyboard Commands ......................................................................................................................20 Product Certification Markings ........................................................................................................27
4
Contents
1 Setting up the System
Safety Information
Server Position
Please take note of the following criteria for creating a practical and safe workplace when setting up your computer:
! CAUTION
The system can be used anywhere the temperature is suitable for people. However, rooms with humidity over 70%, and dusty or dirty areas are not appropriate. In addition, do not expose the server to any temperatures over +30°C or under +10°C.
! CAUTION
For proper cooling and airflow, operate the system only with the chassis covers installed.
! CAUTION
Make sure that the cables connecting the server to peripheral devices are not tight.
! CAUTION
Make sure that all power and connection cables are positioned so that they are not trip hazards.
! CAUTION
When you save data to your server`s hard disks or to a floppy disk, they are stored as magnetic information on the media. Make sure that they are not damaged by magnetic or electromagnetic fields.
! CAUTION
Because the electronics in your computer can be damaged by jarring, no mechanical devices should be placed on the same surface as the server. This is especially important for impact printers whose vibrations could damage the hard disk.
! CAUTION
Hazardous conditions, devices and cables: Hazardous electrical conditions may be present on power, telephone, and communication cables. Turn off the server and disconnect the power cord, telecommunications systems, networks, and modems attached to the server before opening it. Otherwise, personal injury or equipment damage can result.
! CAUTION
Electrostatic discharge (ESD) and ESD protection: ESD can damage disk drives, boards, and other parts. We recommend that you perform all procedures in chapter 3 only at an ESD workstation. If one is not available, provide some ESD protection by wearing an antistatic wrist strap attached to chassis ground - any unpainted metal surface - on your server when handling parts.
! ATTENTION
In order to fully separate the server from current, the power cord must be removed from the wall outlet.
! ATTENTION
To ensure stability, the floor stands must be turned outwards (pedestal version only).
MAXDATA PLATINUM 200 I M7
5
System Access Warnings
! CAUTION
To avoid personal injury or property damage, the following safety instructions apply whenever accessing the inside of the product: · · · · · · · · Turn off all peripheral devices connected to this product. Turn off the system by pressing the power button to off. Disconnect the AC power by unplugging all AC power cords from the system or wall outlet. Disconnect all cables and telecommunication lines that are connected to the system. Retain all screws or other fasteners when removing access cover(s). Upon completion of accessing inside the product, refasten access cover with original screws or fasteners. Do not access the inside of the power supply. There are no serviceable parts in the power supply. Return to manufacturer for servicing. Power down the server and disconnect all power cords before adding or replacing any non hotplug component. When replacing a hot-plug power supply, unplug the power cord to the power supply being replaced before removing the power supply from the server.
! CAUTION
If the server has been running, any installed processor(s) and heat sink(s) may be hot. Unless you are adding or removing a hot-plug component, allow the system to cool before opening the covers. To avoid the possibility of coming into contact with hot component(s) during a hotplug installation, be careful when removing or installing the hot-plug component(s).
! CAUTION
To avoid injury do not contact moving fan blades. If your system is supplied with a guard over the fan, do not operate the system without the fan guard in place.
Rack Mount Warnings
The equipment rack must be anchored to an unmovable support to prevent it from tipping when a server or piece of equipment is extended from it. The equipment rack must be installed according to the rack manufacturer`s instructions. Install equipment in the rack from the bottom up, with the heaviest equipment at the bottom of the rack. Extend only one piece of equipment from the rack at a time. You are responsible for installing a main power disconnect for the entire rack unit. This main disconnect must be readily accessible, and it must be labeled as controlling power to the entire unit, not just to the server(s). To avoid risk of potential electric shock, a proper safety ground must be implemented for the rack and each piece of equipment installed in it.
6
Setting up the System
Powering up the System
At the front of the case, you can find the neccessary controls like power button, reset button and the HDD LEDs. Press the power button one time briefly in order to boot the server.
A B C D E
G H I
F
Figure 1. PLATINUM 200 I Controls
A. B. C. D.
Power LED HDD LED NIC2 LED (not used in this system) NIC1 LED
E. F. G. H. I.
Fan Warning LED Front USB ports Power switch Reset switch Disable Fan Warning
MAXDATA PLATINUM 200 I M7
7
8
2 Board Features
This chapter briefly describes the main features of the mainboard. Table 1 summarizes the major features of the board.
Table 1. Feature Summary Feature Processor Description · Support for one Intel® Xeon® Processor 3000 Sequence, Intel® Pentium® D, Pentium® 4 or Celeron® D processor · Supports Intel® Dual Core Architecture · Supports Intel® Hyper-Threading Technology · Supports Intel® Extended Memory System 64 Technology (EM64T) · 4 DIMM sockets supporting 533/667 MHz ECC or non-ECC unbuffered stacked DDR2 DIMMs · Data bandwidth per channel of 4.2 GB/s or 8.4 GB/s in dual channel when using DDR2 667 MHz · Support for up to two DDR2 channels for a total of 4 DIMMs (2 DIMMs / Channel) providing up to 8 GB max memory capacity Intel® 3000 chipset, consisting of: · Intel® 3000 MCH Memory Controller Hub · Intel® ICH7R I/O Controller Hub Super I/O: SMsC SCH5027 External connections: · Stacked PS2 Keyboard/Mouse connections · DB9 Serial A port · One RJ45 NIC connector for 10/100/1000 Mbps connections · Two USB 2.0 ports Internal connections: · One USB port header which supports two USB 2.0 ports · One DH10 Serial B header · Four SATA connectors with integrated RAID 0/1/10 support · One ATA-100 connector · ATX-compliant 24-pin control panel header Video Expansion Capabilities On-board ATI ES1000 video controller with 16 MB external video memory · Two full length 32 bit / 33 MHz, 3.3 V Universal PCI connectors · One x8 PCI Express connector · One physical x8 PCI Express connector (operating at x4 lane speed) · Ultra ATA100 support: One IDE channel capable of supporting up to two drives. · SATA support: Four independent SATA ports support data transfer rates up to 3.0 Gbit/s per port Support for up to four system fans and one processor fan Intel® System Management Software
Memory
Chipset
I/O Control
Hard drive
Fans System Management
MAXDATA PLATINUM 200 I M7
9
Connector and Header Locations
Figure 2 shows the approximate location of the major components on board.
A
BC
D
EFG H
I
J K
LL
L M
KK JJ II HH GG FF EE DD
CC
AA Y BB Z X
W
VU T
SR Q P
O
N
Figure 2. Board Connector and Component Locations
Table 2. Board Connectors and Components Label Description A. B. C. D. E. F. G. H. I. J. K. L. M. N. O. P . Q. R. S. Video Memory PCI 32/33 Slot 2 ATI ES1000 Video Controller PCIe x8 (x4 Lane) Slot 5 PCIe x8 (x8 Lane) Slot 6 LAN SPI Flash Intel® 82573E LAN Controller Clock Generator Back Panel Connectors Rear System Fan 2x4 Power Connector Processor Socket Processor Fan DIMM Sockets (2B and 2A) DIMM Sockets (1B and 1A) System Front DIMM Blower Header System Front Processor Blower Header Chassis Intrusion Header Intel S3000 MCH
®
Label Description T. U. V. W. X. Y. Z. AA. BB. CC. DD. EE. FF. GG. HH. II. JJ. KK. LL. Battery 2x12 Main Power Connector Front System Fan Floppy Connector PATA IDE Connector SATA Port 3 SMSC SCH5027 Super I/O SATA Port 2 Intel® 82801 ICH7R Front Panel Connector SCSI HDD LED Header SATA Port 1 Clear CMOS Jumper SATA Port 0 BIOS SPI Flash External USB Connector SPI/FWH Select Header SMBus Connector PCI 32/33 Slot 1
10
Board Features
Configuration Jumpers
Figure 3 shows the location of the configuration jumpers.
CMOS CLR
J1G3
2 3
Default CLEAR CMOS
BIOS
J1H3
3 2
Default
Remove jumper for BIOS recovery
Figure 3. Configuration Jumpers
Table 3. Configuration Jumpers Jumper Name CMOS Clear What happens at system reset... If pins 2-3 are jumpered, the CMOS settings will be cleared on the next reset. These pins should be jumpered on 1-2 for normal operation. Remove the jumper for BIOS recovery. These pins should be jumpered on 1-2 for normal operation.
BIOS Recovery
MAXDATA PLATINUM 200 I M7
11
Back Panel Connectors
D
B
A
C
Figure 4. Back panel Connectors
E
Table 4. Back panel Connectors Label Description A. B. C. Stacked PS2 Mouse/Keyboard Ports Serial A Video Label Description D. E. NIC (10/100/1000 Mbps) USB1-2
The NIC LEDs at the right and left of the NIC provide the following information:
Table 5. NIC LEDs LED Left LED State Off Solid Green Blinking Green Right Off Solid Green Solid Yellow Description No network connection Network connection in place Transmit/receive activity 10 Mbps connection (if left LED is on or blinking) 100 Mbps connection 1000 Mbps connection
12
Board Features
Hardware Requirements
To avoid integration difficulties and possible board damage, your system must meet the requirements outlined below.
Memory
The Intel® Server Board S3000AH provides four DIMM sockets across two banks. Bank 1 consists of DIMM sockets 1A and 1B. Bank 2 consists of DIMM sockets 2A and 2B. Minimum memory operation is a single 256MB DIMM in socket 1A. This will provide single-channel interleave. For dual-channel interleave, two identical DIMMs are required in sockets 1A and 1B. To operate in dual-channel dynamic paging mode, the following conditions must be met: · · Populate two identical DIMMs in sockets DIMM1A and DIMM 1B. Populate four identical DIMMs in each socket location.
Note
The use of three DIMMs is not supported. Use DIMMs that are the same type and speed. Use of identical DIMMs is preferred. DIMMs must meet the following requirements: · · Use only DIMMs with DDR2 DRAM technology. Use only DDR2-533 and DDR2-667 stacked DIMM modules.
MAXDATA PLATINUM 200 I M7
13
14
3 Hardware Installations and Upgrades
Before You Begin
Before working with your server product, pay close attention to the "Safety Information" at the beginning of this manual.
Tools and Supplies Needed
· · ·
Phillips (cross head) screwdriver (#1 bit and #2 bit) Needle nosed pliers Antistatic wrist strap and conductive foam pad (recommended)
Installing and Removing Memory
The silkscreen on the board for the DIMMs displays DIMM 1A, DIMM 1B, DIMM 2A, DIMM 2B starting from the center of the board. DIMM 1A is the socket closest to the processor socket. See ,,Memory" for a discussion of the memory requirements and options.
Installing DIMMs
To install DIMMs, follow these steps: 1. Observe the safety and ESD precautions in "Safety Information". 2. Turn off all peripheral devices connected to the server. Turn off the server. 3. Disconnect the AC power cord from the server. 4. Remove the server`s cover. 5. Locate the DIMM sockets (see Figure 5).
C
D
B
A
DIMM 1A DIMM 2A DIMM 2B DIMM 1B
Figure 5. Installing DIMMs
MAXDATA PLATINUM 200 I M7
15
6. Make sure the clips at either end of the DIMM socket(s) are pushed outward to the open position (see letter "A" in Figure 5). 7. Holding the DIMM by the edges, remove it from its anti-static package. 8. Position the DIMM above the socket. Align the notch on the bottom edge of the DIMM with the key in the DIMM socket (see letter "B" in Figure 5). 9. Insert the bottom edge of the DIMM into the socket (see letter "C" in Figure 5). 10. When the DIMM is inserted, push down on the top edge of the DIMM until the retaining clips snap into place. Make sure the clips are firmly in place (see letter "D" in Figure 5). 11. Replace the server`s cover and reconnect the AC power cord.
16
Hardware Installations and Upgrades
Replacing the Backup Battery
The lithium battery on the server board powers the RTC for up to 10 years in the absence of power. When the battery starts to weaken, it loses voltage, and the server settings stored in CMOS RAM in the RTC (for example, the date and time) may be wrong. Contact your customer service representative or dealer for a list of approved devices.
! WARNING
Danger of explosion if battery is incorrectly replaced. Replace only with the same or equivalent type recommended by the equipment manufacturer. Discard used batteries according to manufacturer's instructions.
! WARNUNG
Wenn eine ungeeignete Batterie eingesetzt wird oder die Batterie falsch eingesetzt wird, besteht Explosionsgefahr. Ersetzen Sie verbrauchte Batterien nur durch Batterien gleichen oder äquivalenten Typs, der vom Hersteller empfohlen wurde. Entsorgen Sie die verbrauchte Batterie entsprechend den Anweisungen des Herstellers.
! AVERTISSEMENT
Danger d'explosion en cas de remplacement incorrect de la pile. Remplacez-la uniquement par une pile du même type ou d'un type équivalent recommandé par le fabricant. Mettez au rebut les piles usagées en vous conformant aux instructions du fabricant.
! OSTRZEENIE
Nieprawidlowa wymiana baterii grozi eksplozj. Wymienia tylko na taki sam lub równowany typ, zalecany przez producenta. Zuyte baterie utylizowa zgodnie z instrukcjami producenta.
! ADVARSEL
Lithiumbatteri - Eksplosionsfare ved fejlagtig håndtering. Udskiftning må kun ske med batteri af samme fabrikat og type. Levér det brugte batteri tilbage til leverandøren.
! ADVARSEL
Lithiumbatteri - Eksplosjonsfare. Ved utskifting benyttes kun batteri som anbefalt av apparatfabrikanten. Brukt batteri returneres apparatleverandøren.
! VARNING
Explosionsfara vid felaktigt batteribyte. Använd samma batterityp eller en ekvivalent typ som rekommenderas av apparattillverkaren. Kassera använt batteri enligt fabrikantens
instruktion.
! VAROITUS
Paristo voi räjähtää, jos se on virheellisesti asennettu. Vaihda paristo ainoastaan laitevalmistajan suosittelemaan tyyppiin. Hävitä käytetty paristo valmistajan ohjeiden mukaisesti.
MAXDATA PLATINUM 200 I M7
17
To replace the battery, follow these steps: 1. Observe the safety and ESD precautions in "Safety Information". 2. Turn off all peripheral devices connected to the server. Turn off the server. 3. Disconnect the AC power cord from the server. 4. Remove the server`s cover and locate the battery. 5. Lift the battery retention mechanism (see Figure 6). 6. Remove the battery from its socket.
Figure 6. Removing the Battery
7. Dispose of the battery according to local ordinance. 8. Remove the new lithium battery from its package, and, being careful to observe the correct polarity, insert it in the battery socket. 9. Close the chassis. 10. Run Setup to restore the configuration settings to the RTC.
18
Hardware Installations and Upgrades
4 Server Utilities
Using the BIOS Setup Utility
This section describes the BIOS Setup Utility options, which is used to change server configuration defaults. You can run BIOS Setup with or without an operating system being present.
Starting Setup
You can enter and start BIOS Setup under several conditions: · · When you turn on the server, after POST completes the memory test When you have moved the CMOS jumper on the server board to the "Clear CMOS" position (enabled)
In the two conditions listed above, during the Power On Self Test (POST), you will see this prompt:
Press
If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Diplodocs provides you a fast and easy access to the user manual MAXDATA PLATINUM 200I M7. MAXDATA offer a product for which we do not have the user manual? Let us know what you are looking for: user guide, owner's manual, online manual, operating instructions, quick start guide, mounting instructions, schematics, service manual, installation instructions, RTFM. Diplodocs allows you to download user manual MAXDATA PLATINUM 200I M7, user guide MAXDATA PLATINUM 200I M7, instructions MAXDATA PLATINUM 200I M7, owner's manual MAXDATA PLATINUM 200I M7, online manual MAXDATA PLATINUM 200I M7.MAXDATA PLATINUM 200I M7, , Desktop PC, Mini PC & Mac Desktop Computer. |
![]() |
Include the add-on to download manuals from your site, forum or blog | ![]() |
Frequently Asked Questions | ![]() |
Contact Diplodocs team | ![]() |
Last searches Last additions |
![]() |
Sitemap | ![]() |
|||
| Brands starting with A B C D E F G H I J K L M N O P Q R S T U V W X Y Z # | |||||||||||||
|
|
Copyright © 2005 - 2008 - Diplodocs -
All Rights Reserved. Designated trademarks and brands are the property of their respective owners. |