Manual abstract: user guide MAYTAG MDE1100AES
Detailed instructions for use are in the User's Guide. Use and Care Guide Drying cabinet
MDE 1100AES
Dear MAYTAG customer! Congratulations on your excellent product choice and welcome to the Maytag family. A global family with its roots in Scandinavia. Cleaning results, design, environmental impact on nature and home, user friendliness, low consumption of time, energy and water, a long life span, reliability.... Good appliances should include all of these. And this is what we try to give you. When you buy an MAYTAG product, we want you to feel assured that the inside is as good as the outside and that the ethics and morals on which we built this machine are just as high as the quality and performance you get from it. That is what Scandinavian quality is all about. In order to get the best possible results from your machine and all its functions, please read this Use and Care Guide before using the machine for the first time. And if you have any questions, please do not hesitate to call us or contact us via our web site. Best regards from Scandinavia and the people at Maytag.
Contents
Safety Instructions . . . . . . . . . . . . . . . 4 Symbols . . . . . . . . . . . . . . . . . . . . 4 Important safety information . . . . . . 4 Description of the drying cabinet . . . . 5 Control panel . . . . . . . . . . . . . . . . . . . . 6 Where to install it. . . . . . . . . . . . . . . . . 7 Electrical requirements . . . . . . . . . . . . 8 User's responsibility . . . . . . . . . . . 8 Electrical connection . . . . . . . . . . . 8 Ventilation alternatives . . . . . . . . . . . . 9 Ventilation out into the room where the drying cabinet is located . . . . 9 Connection to a vent duct . . . . . . 10 Installation . . . . . . . . . . . . . . . . . . . . . Unpacking . . . . . . . . . . . . . . . . . . Complete delivery includes . . . . . Recommended tools . . . . . . . . . . Placing the door the other way round. . . . . . . . . . . . . . . . . . . . . . Horizontal adjustment . . . . . . . . Mounting . . . . . . . . . . . . . . . . . . . Mounting into custom cabinetry. . . Ventilation connection . . . . . . . . . Electrical connection . . . . . . . . . . Final check . . . . . . . . . . . . . . . . . 12 12 12 12 13 14 14 15 17 17 18 How to use the drying cabinet . . . . . Starting . . . . . . . . . . . . . . . . . . . . Setting pause and restart . . . . . . Stopping . . . . . . . . . . . . . . . . . . . Loading . . . . . . . . . . . . . . . . . . . . Some advice for users . . . . . . . . Setting the temperature selector knob . . . . . . . . . . . . . . . . . . . . . . 19 19 19 19 19 20 21
Care. . . . . . . . . . . . . . . . . . . . . . . . . . . 22 Cleaning the drying cabinet . . . . 22 When the drying cabinet is not in use . . . . . . . . . . . . . . . . . . . . . . . 22 Trouble Shooting . . . . . . . . . . . . . . . . 23 Service . . . . . . . . . . . . . . . . . . . . . . . . 24 Technical information . . . . . . . . . . . . Technical characteristics . . . . . . . Evacuation/Air intake . . . . . . . . . Energy consumption and drying time . . . . . . . . . . . . . . . . . . . . . . Manufacturing standards. . . . . . . Air gap left during mounting . . . . 25 25 25 25 25 25
Personal notes . . . . . . . . . . . . . . . . . . 26
3
Safety Instructions
Read this manual very carefully and follow the instructions provided. Especially important information is indicated by the accompanying symbols and text WARNING or ATTENTION.
Symbols
WARNING Indicates a risk of personal injuries or serious damage to the product if the instructions are not followed. Advice and instructions about the best way to use the product and avoid operating disorders. ATTENTION Other important remarks
Important safety information
The following advice and warnings have been drawn up, so that you may avoid both misusing the drying cabinet and the risk of unnecessary accidents. So read the following through very carefully before installing and using the drying cabinet. Read this Use and Care Guide before using the drying cabinet. Do not dry articles of clothing or similar items which have just been treated with petrol or some other volatile and inflammable agent. This can result in the build up of an explosive mixture of gases. Do not allow children to play in or on the drying cabinet. Keep an eye on children when they are in the immediate vicinity of the cabinet. Keep this Use and Care Guide in a safe place so that it will always be at hand for future reference. The drying cabinet should be installed or kept in storage indoors. Follow Asko's recommendations concerning repairs and spare part replacement. If a softening agent or antistatic substance is used, the manufacturer's instructions concerning the utilisation of the product should be followed. Do not use heat in the cabinet for products containing foam rubber or similar material. Follow the manufacturer's washing and drying instructions for such products very carefully. Keep the area around the evacuation duct free from dust and dirt. Regularly clean the inside of the drying cabinet.
4
Description of the drying cabinet
9 1 2 3 4 11 12
X DC XXX
10
5
6
7
13
8
1. 2. 3. 4. 5. 6. 7. 8.
Exhaust collar Drying cabinet model Hanger hooks Identification plate (inside) Upper hanger section Middle hanger section Lower hanger section Shoe rack
9.
Air intake
10. Control panel 11. Door 12. Door hanger for lighter items 12. Glove hanger
5
Control panel
1
2
1. 2.
Temperature setting Timer
6
Where to install it
If the drying cabinet is to be installed with a connection to exhaust air ventilation, this must be available on the premises. See futher section "Ventilation alternatives", page 9. A grounded electrical outlet must be within 79 in. (2 meters) of the drying cabinet's upper section. A 79-in. (2-meter) grounded power cord with a plug is connected at the top of the drying cabinet. If the electrical outlet is not located as above, the location must be adjusted so that an extension cord is not necessary. The electrical outlet shall be easily accessible after installation of the drying cabinet. Take this into consideration even in cases when the drying cabinet is built into custom cabinetry or similar framing. For further information, see the section "Electrical requirements". The floor must be able to support the weight of the cabinet 133 lbs (60 kg). The floor must be flat with a slope under the cabinet of no more than 1 in. (2.5 cm). The drying cabinet is only intended for installation indoors and at temperatures above 0°C (32°F). The drying cabinet may not be located in environments where pressurized water is used for cleaning.
595 mm
640 mm
1730 mm
610 mm
7
Electrical requirements
User's responsibility
It is the responsibility of the user to contact a qualified electrician if the electric outlet socket is not easily accessible as laid down in this manual WARNING Connect to grounded wall outlet . Do not use an adapter or an extension cord.
Electrical connection
The drying cabinet must be connected to a 230 Volt single-phase 50 Hz grounded wall outlet. The electric outlet must be installed and grounded in accordance with regulations in force. The drying cabinet is delivered complete with connections, including a 2 metre long cable with a grounded plug. Do not change the flexible cord and plug which come with the drying cabinet. If the plug is not adapted to the electric outlet, this problem should be put in the hands of a qualified technician. The drying cabinet should be connected with the provided connector cable and must not be permanently connected! The electrical outlet should be placed in such a way that the plug can easily be pulled out whenever necessary. Check that mains supply complies with the data on the identification plate and also that the main lead is grounded in the correct fashion, according to standards in force. We recommend that the main lead be provided with a circuit breaker. The connection shall be separately fused. The manufacturer declines all responsibility for any consequences if the electrical connection is not made in the manner laid down in this Use and Care Guide.
8
Ventilation alternatives
Moist air can be discharged in two ways: Ventilation out into the room where the drying cabinet is located Connection to a vent duct (exhaust air ventilation)
Ventilation out into the room where the drying cabinet is located
Do not hesitate to open doors or windows in the room for optimum ventilation. In the case of an inbuilt drying cabinet, exchange the flexible ventilation hose delivered with the cabinet (only certain markets) for a rigid ventilation pipe of 100 mm in diameter. The distance between the top edge of the pipe and the ceiling should not be less than 300 mm. The ventilation pipe must reach the outside of the cabinet mounting unit. Be sure that there is a good supply of air to the drying cabinet air intake orifice.
The room must be well aired
1. 2.
Humid air out Air intake
Ceiling Minimum 300 mm Ceiling Minimum 300 mm 2 1
1
2
Ventilation out into the room where the drying cabinet is located. Drying cabinet not built in
Ventilation out into the room where the drying cabinet is located. Built-in drying cabinet in custom cabinetry
9
Connection to a vent duct
When the cabinet is on, 45 m³ of humid air are evacuated per hour. So make sure that air can penetrate into the room to replace the humid air given off by the drying cabinet. ATTENTION The drying cabinet must not be connected to the fireplace chimney
The drying cabinet can be connected to a vent duct in two ways:
With a draft stabilizer
The ventilation duct valve is replaced by a draft stabilizer (included in the delivery). See also the section 'Connect Ventilation' page 17. Do not assemble the ventilation duct valve inside the drying cabinet
1. 2. 6 3. 4. 5. 4 6. Humid air out Hose Exhaust collar Draft stabilizer Air intake Ventilation duct valve
1 5 2
3
The drying cabinet is connected to the evacuation duct with a draft stabilizer
10
Permanently installed and connected to a vent duct (only certain markets)
When the drying cabinet is permanently connected to the vent duct, the entire room is ventilated through the drying cabinet. The ventilation duct valve is replaced by an adapter (not included). See also the section 'Connect Ventilation' page 17. ATTENTION Only the evacuation hose delivered with the cabinet must be used. (For the markets where such an article is included)
Do not assemble the ventilation duct valve inside the drying cabinet.
3
1
1. Adapter 2. Air intake 3. Ventilation duct valve 2
The drying cabinet permanently installed and connected to the evacuation duct
11
Installation
Unpacking
WARNING The cabinet can easily tip over since it is not yet solidly screwed into place. WARNING The packing material such as plastic or frigolite should be kept out of children´s way.
Take off all the packing material; do not use a sharp tool which could damage the product. Check that the drying cabinet has not been damaged during transportation. The distributor should be notified of any damage during transportation within 7 days.
After unpacking, check that the drying cabinet is free from defects. The distributor should immediately be notified of any damage, defects or even missing parts. Check that all the safety devices used for transportation have been removed before the drying cabinet is connected.
Complete delivery includes
The cabinet with the fan unit Flexible hose for ventilation (only certain markets) Exhaust collar with 2 attachment screws Draft stabilizer (only certain markets) Attachment screws (2 screws, washers and protective caps) for firmly fixing the cabinet to the wall Allen wrench and protective caps for the adjustable feet The Use and Care Guide for installation and utilisation
Recommended tools
Bubble level Tape measure Hand drill Screwdriver (Phillips) An 8 mm diameter drill bit Pencil Protective gloves (if supplied)
12
Placing the door the other way round
The door can be hung on its hinges on the left or the right. 1. Lay the drying cabinet on its back side. 2. Disengage the hinge pin of the bottom hinge (1) and lift the door off. 3. Take off the plastic plug and press it right down on to the bottom hinge on the opposite side. 4. Disengage the hinge pin of the upper hinge (2) and place it on the opposite side. 5. Completely unscrew the glove hangers on the inside of the door and turn them completely around. The glove hangers are fastened into place with four screws. 6. Rotate the door, fit it into place and fix it firmly by means of the lower hinge pin (1).
2
1
13
Horizontal adjustment
1. Lift out the shoe rack. 2. Control that surfaces are horizontal by placing a bubble level parallel to the walls and parallel to the back and the door. 3. Use the Allen wrench provided, and correct the position of all four adjustable feet through the holes in the base plate of the drying cabinet (u ...
|