|
5 600 brands
1 870 000 user's guides |
|
|
|||||||||||||||
|
Search a brand
Advanced Search
|
Our partners wish to propose you the following products
|
User manual MEADE 506
Diplodocs help download the user guide MEADE 506.
Preview of the first 3 pages of manual
You either have JavaScript turned off or an old version of Adobe Flash Player Get the latest Flash Player.
User guide MEADE 506
Detailed instructions for use are in the User's Guide. Operating Instructions
#506 AstroFinderTM Software and Cable Connector Kit
For use with the Meade® #494 AutoStarTM Computer Controller
The #506 AstroFinder Software and Cable Connector Kit provides access to two #494 AutoStar operations: · Telescope Control: Use a personal computer (PC) to directly control a Meade #494 AutoStar-compatible telescope through the use of an astronomical software program with telescope control capabilities such as Meade AutoStar Suite Software. Download from a PC: Download a new version of the #494 AutoStar software or object information (e.g., new satellite orbital parameters) from the Meade web site (www.meade.com) through a PC to the #494 AutoStar. · · · · · 7. Baud Rate Data Bits Parity Stop bit Flow Control 9600 8 None 1 None
·
Complete telescope alignment as detailed in your instruction manual.
Follow the instructions provided with the software to control your telescope. NOTE: The AutoStar GO TO function is still active when connected to an astronomical software program, allowing control either from the PC or AutoStar.
PARTS LIST
The · · · #506 Cable Connector Kit includes the following: 6-foot, 4-pin to 6-pin cable with integrated AUX-to-serial converter 6-pin to RS-232 serial interface adapter AstroFinder software (CD-Rom)
DOWNLOAD FROM A PC
To download software or object information from a PC to AutoStar, follow this procedure: NOTE: Downloading information is a two-step process: First, information is downloaded from a website to your PC; second, information is downloaded from the PC to AutoStar.
TELESCOPE CONTROL
A powerful feature of AutoStar is that it serves as an interface between an astronomical software program, such as Meade AutoStar Suite Software. To use this function, complete the following procedure: 1. 2. 3. Verify that telescope and computer power are OFF. Connect the serial interface adapter (1, Fig. 1) to the RS232 port on your PC. Connect the 6-pin end of the 6-foot cable (2, Fig. 1) to the serial interface adapter, then connect the 4-pin end to the AUX port at the base of the telescope mount (5, Fig. 1). Connect the #494 AutoStar to the HBX port (4, Fig. 1) on the telescope computer control panel. 1. 2.
ENTER
Download from the website to the PC
1. From your PC, connect to the Meade website (www.meade.com) to download an AutoStar file or files (i.e., new software, orbital elements, etc.). Follow the instructions from your web browser (i.e., Internet Explorer, Netscape, etc.) on how to download a file from the Internet to the PC. Once downloaded, the data reside in a PC desktop program titled AUTOSTAR UPDATE (a READ ME file is also attached). Complete steps 1 through 6 of TELESCOPE CONTROL detailed earlier in this instruction sheet, then return to this procedure. Open the AUTOSTAR UPDATE program on the PC. NOTE: Not all files downloaded from the website to the PC have to be transferred to AutoStar (i.e., software and orbital data may be downloaded to the PC, but you may choose to update the software now and the orbital data at a later time). 3. 4. Within the AUTOSTAR UPDATE program, select the file or files you wish to transfer and follow the instructions provided in the READ ME file. When downloading is complete, AutoStar beeps and the initialization sequence begins. When complete, turn off the telescope's power and disconnect the cables.
2.
4.
Download from the PC to AutoStar
MODE
GO TO
MEADE
4
HBX
AUX
5 3
6
MEADE
2 1
AutoStar downloading from a PC is now complete. If you have a question concerning use of the #506 Cable Connector Kit, call the Meade Instruments Customer Service Department at (949) 451-1450, or fax to (949) 451-1460. Customer Service hours are 8:00 AM to 5:00 PM, Pacific Time, Monday through Friday.
Fig. 1: The #506 Connector Cable Set connects between a PC and #494 AutoStar for telescope computer control or download capabilities. (1) Serial Interface Adapter; (2) 6-Foot Cable; (3) #494 AutoStar; (4) Handbox (HBX) port on the telescope's computer control panel; (5) AUX port; (6) CPU.
5. 6.
Apply power to the telescope and computer, then complete basic AutoStar initialization as detailed in the AutoStar instruction manual. Be sure that the computer Com Port is configured to the following specifications:
(800) 626-3233
www.meade.com
Ver. 0805
Part no. 14-4020-06
If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Diplodocs provides you a fast and easy access to the user manual MEADE 506. MEADE offer a product for which we do not have the user manual? Let us know what you are looking for: user guide, owner's manual, online manual, operating instructions, quick start guide, mounting instructions, schematics, service manual, installation instructions, RTFM. Diplodocs allows you to download user manual MEADE 506, user guide MEADE 506, instructions MEADE 506, owner's manual MEADE 506, online manual MEADE 506.MEADE 506, , Binocular | Telescope. |
![]() |
Include the add-on to download manuals from your site, forum or blog | ![]() |
Frequently Asked Questions | ![]() |
Contact Diplodocs team | ![]() |
Last searches Last additions |
![]() |
Sitemap | ![]() |
|||
| Brands starting with A B C D E F G H I J K L M N O P Q R S T U V W X Y Z # | |||||||||||||
|
|
Copyright © 2005 - 2008 - Diplodocs -
All Rights Reserved. Designated trademarks and brands are the property of their respective owners. |