5 600 brands
1 870 000 user's guides |
|
|
|||||||||||||||
|
Search a brand
Advanced Search
|
Our partners wish to propose you the following products
|
User manual MINOLTA DIMAGE SCAN DUAL
Diplodocs help download the user guide MINOLTA DIMAGE SCAN DUAL.
You may also download the following manuals related to this product:
Preview of the first 3 pages of manual
You either have JavaScript turned off or an old version of Adobe Flash Player Get the latest Flash Player.
User guide MINOLTA DIMAGE SCAN DUAL
Detailed instructions for use are in the User's Guide. Windows Version
Thank you for purchasing the Minolta Dimâge Scan Dual. The Dimâge Scan Dual is a dual format film scanner capable of scanning 35mm and, with the optional AD-10 APS Adapter, Advanced Photo System film. This manual has been designed to help you understand the operation of your scanner. To realize all the benefits of your scanner, please read this manual thoroughly. Your scanner has been packaged with the DS Dual twain driver software for Adobe PhotoshopTM/ Adobe PhotoDeluxeTM. Before using the Minolta Dimâge Scan Dual, we recommend you have a working knowledge of the PC and its operating conventions. Familiarity with the mouse and Windows® menus and commands is necessary before operating the Minolta Dimâge Scan Dual driver software. This manual does not instruct in the basic use of the PC, the Windows® 95, Windows® 98, or Windows NT® operating systems, Adobe PhotoshopTM , or Adobe PhotoDeluxeTM. MS, MS-DOS, Microsoft, Windows®, Windows® 95, Windows 98®, and Windows NT® are registered trademarks of the Microsoft Corporation. Adobe®, PhotoshopTM, and Adobe PhotoDeluxeTM are registered trademarks of Adobe Systems Inc. Corel DrawTM is a trademark of the Corel Corporation. Other corporate and product names are the trademarks and registered trademarks of their respective companies.
· Changes or modifications not approved by the party responsible for compliance could void the user's authority to operate the equipment. · This manual may not be copied in part or whole without prior written permission from Minolta Co., Ltd. ©1997 Minolta Co., Ltd. · Every necessary caution has been taken to ensure the accuracy of this instruction manual. Please contact us if you have any questions, find any errors, or notice missing information. · Minolta is not responsible for loss, damage, or other results occurring during the operation of this product.
This mark certifies that this product meets the requirements of the EU (European Union) concerning interference causing equipment regulations. CE stands for Conformité Européenne. This device complies with Part 15 of the FCC Rules. Operation is subject to the following conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. To meet FCC regulations, the SCSI cables used with this scanner must be equipped with ferrite cores. This Class B digital apparatus meets all the requirements of the Canadian InterferenceCausing Equipment Regulations. Cet appareil numérique de la classe B respecte toutes les exigences du Règlement sur le matériel brouilleur du Canada. Tested by the Minolta Corporation 101 Williams Drive Ramsey, New Jersey 07446 USA
FOR PROPER AND SAFE USE
Please read and understand each caution before using this product.
CAUTION
To avoid fire or electric shock:
· · · · · Only use the voltage specified for this unit. Do not expose this unit to liquids. Do not insert metal objects into this unit. Do not touch the cord or plug if your hands are wet. Unplug this unit when it is not in use.
Improper use of the power cord may result in fire or electric shock.
· Insert the plug securely into an electrical outlet. · Do not pull on the cord. Grasp the plug when removing the power cord from an outlet. · Do not scratch, twist, modify, heat, or place a heavy object on the power cord. · Do not connect the ground to a gas pipe, telephone ground, or a water pipe. Improper grounding can result in electric shock.
This product must have sufficient ventilation while in use. Blocked ventilation ducts may cause the unit to overheat, increasing the risk of fire.
· Do not use or store this product in dusty or very humid areas.
If there is smoke, a strange smell, or any other unusual conditions, shut down and unplug the unit, then contact a Minolta Service Facility. Do not attempt to disassemble this product. It contains high-voltage circuits. Take the product to a Minolta Service facility for repairs. Unexpected damage may occur if this unit is left unattended near young children.
Dimâge Scan Dual
1
PACKAGE CONTENTS / SYSTEM REQUIREMENTS
The following contents should be included in this package.
1. 2. 3. 4. 5. 6. 7. 8. Minolta Dimâge Scan Dual 35mm Slide and Negative holders SCSI cable SC-11 AC power cord DS Dual installer CD ROM Instruction Manuals (2) Warranty card Photoshop LE CD ROM
System Requirements
CPU: IBM PC/AT compatible with a 486SX-25 MHz processor or better. A Pentium is recommended to obtain all the benefits of this software.
· Support cannot be provided for custom or home built machines.
Operating System: Windows 95, Windows 98, or Windows NT Memory: A minimum of 8 MB application RAM in addition to the requirements for the OS and Adobe Photoshop (or PhotoDeluxe). 32 MB of RAM is recommended to obtain all the benefits of this software. 60 MB of available hard disk space. The following Adaptec SCSI boards are recommended for this device: AHA-1520B AHA-1540CP AHA-2940J AHA-2940U AHA2940AU AHA-2910B AVA-2902E AVA-1505AE*
* Applicable for use with Windows 95 only. · Support will not be provided for malfunctions or problems caused by the use of untested SCSI boards.
SCSI Board:
Monitor: Other:
High Colour (16 bit) VGA monitor and video card or better. Photoshop 3.0.5, Photoshop 4.0.1, Photoshop 5.0.1, PhotoDeluxe (ver. 1.0 and 2.0), Corel DRAW (ver 7 and 8), and Corel Photopaint (in Corel DRAW) have been fully tested for use with the TWAIN driver software.
· Use TWAIN 32 to acquire images into Corel Draw and Photopaint. Using CorelScan to access the DS_Dual driver software may cause sizing errors.
2
TABLE OF CONTENTS
FOR PROPER AND SAFE USE PACKAGE CONTENTS . . . . . . SYSTEM REQUIREMENTS . . . TABLE OF CONTENTS . . . . . . NAMES OF PARTS . . . . . . . . . SCANNER SETUP
Setting the SCSI ID . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .6 Connecting the Hardware . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .7 Installing the Software . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .10
. . . .
. . . . .
. . . . .
. . . . .
. . . . .
. . . . .
. . . . .
. . . . .
. . . . .
. . . . .
. . . . .
. . . . .
. . . . .
. . . . .
. . . . .
. . . . .
. . . . .
. . . . .
. . . . .
. . . . .
. . . . .
. . . . .
. . . . .
. . . . .
. . . . .
. . . . .
. . . . .
. . . . .
. . . . .
. . . . .
. . . . .
. . . . .
. . . . .
. . . . .
. . . . .
. . . . .
. . . . .
. . . . .
. . . . .
. . . . .
. . . . .
. . . . .
. . . . .
. . . . .
. . . . .
.1 .2 .2 .3 .4
STANDARD OPERATION
Launching the Software . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .16 Standard Control Window - Names of Parts . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .18 Preview Window - Names of Parts . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .19 Preferences Dialog Box - Names of Parts . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .20 Setting the Preferences . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .21 Loading the Film Holder . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .23 Inserting the Film Holder into the Scanner . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .25 Setting the Film Type . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .26 Prescan . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .26 Selecting the Usage Mode . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .27 Orienting the Image . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .29 Variation Dialog Box - Names of Parts . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .32 Image Correction - Variation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .33 Scanning and Saving the Image . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .34
PRECISION OPERATION
Precission Operation - Startup . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .36 Precision Control Window - Names of Parts . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .37 Loading and Prescan . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .38 Orienting the Image . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .39 Setting the Resolution . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .40 Resolution Notes . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .41 Scan Settings - Save and Load . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .42 Histogram Dialog Box - Names of Parts . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .43 Image Correction - Histogram . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .44 Tone Curve Dialog Box - Names of Parts . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .48 Image Correction - Tone Curve . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .49 Scanning and Saving the Image . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .52
SCANNING APS FILM
Launching the Software . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .54 Setting the Film Type . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .55 Setting the APS Preferences . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .56 APS Adapter - Names of Parts . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .57 Loading the APS Adapter . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .57 Inserting the APS Adapter into the Scanner . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .58 Index Scan . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .59 Prescan and Image Correction . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .60 Scanning the Image . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .61 Quitting the APS Window . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .62
APPENDIX
Trouble-Shooting . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .64 User Technical Support . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .65 Installing Adobe PhotoDeluxe . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .66
Dimâge Scan Dual
3
SCANNER - NAMES OF PARTS
1. Indicator lamp 2. Film slot 3. Film door 4. Power switch 5. SCSI port - DB25 6. Terminator power switch 7. SCSI ID switches 8. SCSI port - SCSI-1 9. AC socket
4
SCANNER SETUP
SETTING THE SCSI ID
A SCSI ID is a unique address you assign to each SCSI device connected to your PC. The SCSI ID range of your PC is from 0 to 7. Do not use a SCSI ID for more than one SCSI device.
Turn off the PC and all the devices in the SCSI chain down before changing SCSI IDs, connecting, or disconnecting SCSI cables. Hardware damage may occur if this precaution is not followed.
Setting the SCSI ID
1. Turn off the PC and all connected SCSI devices. 2. Determine which SCSI IDs are not being used. 3. Using a pointed object, set the switches to an unused SCSI ID.
· The Dimâge Scan Dual's SCSI ID is factory preset to 5. If 5 is not occupied, there is no need to change the SCSI ID. · Two operating SCSI devices in the same SCSI chain cannot share a SCSI ID.
SCSI ID Dip Switch Settings
6
CONNECTING THE HARDWARE
Connecting the SCSI Cable
The SCSI cable SC-11 (DB25-to-SCSI-1) has been packaged with the Dimâge Scan Dual. See your dealer if you require a different SCSI cable.
· To meet FCC regulations, the SCSI cables used with this scanner must be equipped with ferrite cores.
BEFORE YOU BEGIN... TURN THE COMPUTER AND ALL CONNECTED DEVICES OFF. 1. Place the scanner on a level surface. 2. Plug the SCSI cable SC-11 into the SCSI port on the rear of the PC.
3. Plug the other end of the SCSI cable) into the back of the scanner.
· Either SCSI port can be used, there is no dedicated in or out port.
Dimâge Scan Dual
7
CONNECTING THE HARDWARE
If there are other devices in your SCSI chain...
4. Plug the SCSI cable from the next device in your SCSI chain into the open port on the back of the scanner.
5. Plug the power cord into the scanner's AC socket, then plug it into a grounded outlet.
8
CONNECTING THE HARDWARE
If the Dimâge Scan Dual is the last or only device in your SCSI chain...
4. Turn the terminator power switch (switch 4) to ON.
· An external terminator is not necessary with this scanner.
Terminating th e SCSI chain helps to suppress el ectronic noise in the SCSI chai n. Not terminatin g the SCSI ch ain can cause slow downs, data errors, crashe s, and other unpredictable errors.
5. Plug the power cord into the scanner's AC socket, then plug it into a grounded outlet.
Dimâge Scan Dual
9
INSTALLING THE SOFTWARE
Dimâge Scan Dual for Windows Setup installs the Twain and Twain_32 driver software into the drive and folder you select. Photoshop, PhotoDeluxe, Corel DRAW, or Corel PhotoPaint should be installed before you launch this installer.
· The appearance and/or wording of some dialog boxes may vary depending on the version of Windows running on your machine. · The install instructions assume drive D is the CD ROM drive.
1. Turn on the Dimâge Scan Dual, then turn on your PC. 2. Start Windows.
This step varies with your specific operating software...
Windows 95
· The New Hardware Found dialog box will appear.
Windows 95 Release 2 (OSR2) and Windows 98
· The Device Wizard dialog box will appear.
3. Click on Cancel.
· This dialog box may appear several times. Repeat step 3 until the dialog box no longer appears.
3. Click on Next until the Unknown Device window appears... then click on Finish.
· This dialog box may appear several times. Repeat step 3 until the dialog box no longer appears.
Windows NT
3. Select Start > Settings > Control Panel, then double-click on the SCSI Adapters icon. Confirm that Minolta #2882 appears as a connected device for your SCSI board.
· If Minolta #2884 does not appear, turn the system off and check all the connections. Repeat the procedure.
10
INSTALLING THE SOFTWARE
4. Insert the Dimâge Scan Speed CD-ROM into the CD-ROM drive. 5. Select Run from the Start menu. The Run dialog box will appear.
6. Select D:\ENGLISH\Setup.exe from the Open drop-down list, then click on .
· If your CD-ROM drive is not the D drive, replace the D with the appropriate designation for your CD-ROM drive.
The installer flash will appear.
7. Click on
.
Continued on the following page. Dimâge Scan Dual
11
INSTALLING THE SOFTWARE
The Welcome dialog box will appear.
8. Click on
. The Software License Agreement will appear.
9. After reading the agreement, click on
· If you do not agree to the conditions stated in the End-User License Agreement, click on No and the software will not be installed.
.
12
INSTALLING THE SOFTWARE
The Setup Options dialog box will appear.
10. Select the desired option, then click on
.
The Select Program Folder dialog box will appear.
11. Click on
· Setup will begin.
.
Continued on the following page. Dimâge Scan Dual
13
INSTALLING THE SOFTWARE
The Setup Successful dialog box will appear.
12. Click on
. The following dialog box will appear.
13. Click on
.
Dimage Scan Dual for Window Setup has placed the following files onto your computer. DSDual.ds DSDual.du DSDual.hlp dsd_tw.ini Twain.dll Twain_32.dll Twunk_16.exe Twunk_32.exe readme.txt
Please read the Read Me file before proceeding with this manual.
14
S TA N D A R D O P E R AT I O N
SCAN FLOW
Launch the Software
Set the Preferences
Load the Film Holder
Insert the Film Holder
Specify the Film Type
Prescan Select the Output Mode
Orient the Image
Correct the Brightness, Contrast, and Colour
Scan
Save
LAUNCHING THE SOFTWARE
The following instructions detail the import procedure for Adobe Photoshop. Refer to the online manual to import images into Adobe PhotoDeluxe.
1. Turn on the Minolta Dimâge Scan Dual, then turn on your PC. 2. Launch Adobe Photoshop. 3. Select File > Import > Select Twain_32 Source
The Select Source dialog box appears. 4. Select DS_dual, then click on Select
5. Select File > Import > Twain32
16
LAUNCHING THE SOFTWARE
The setup screen will appear.
The Dimâge Scan Dual's standard control and preview windows appear after initialization is complete (approx. 2 min.).
Dimâge Scan Dual
17
STANDARD CONTROL WINDOW NAMES OF PARTS
1. Image use option buttons 2. Image orientation option buttons 3. File size 4. Saving drive storage capacity 5. Preference button 6. Help button 7. Status window
8. Exit button 9. Scan button 10. Prescan button 11. Reset button 12. Relative image size option buttons 13. Image /Paper size list box 14. Film type list box
18
PREVIEW WINDOW NAMES OF PARTS
1. Grab button 2. Enlarge button 3. Flip vertical 4. Rotate 90° right 5. Rotate 90° left 6. Flip horizontal 7. Reduce button 8. RGB values under cursor
9. Full-screen display button 10. Revert to prescan settings button 11. Histogram button 12. Curves button 13. Variations button 14. Cropping frame dimensions 15. Cropping frame 16. Preview window
Dimâge Scan Dual
19
PREFERENCES DIALOG BOX NAMES OF PARTS
1. Click on .
The Preferences dialog box will appear.
1. Scanner control option buttons 2. Close driver after scan checkbox 3. Auto expose positive film checkbox 4. Background colour modify button 5. Preview window size list box 6. Scratch disk list box
7. Unit list box 8. Output resolution list box 9. Input resolution list box 10. Help button 11. Cancel changes button 12. OK Button
20
SETTING THE PREFERENCES
2. Click on the Standard option button.
3. Click on this checkbox if you want to use the auto-exposure system when scanning slides.
· You will obtain better scans from underexposed slide film when this checkbox is selected.
4. Select the desired preview window size from the drop-down list.
5. Select the saving directory.
· The number of options depends on the number of drives connected to your system.
6. Click on the "Close driver after scanning" checkbox to automatically shut down the driver software after scanning.
Continued on the following page. Dimâge Scan Dual
21
SETTING THE PREFERENCES
7. Click on to change the background colour of the full screen display.
· The colour chip displays the background colour currently selected.
The Colour Palette dialog box will appear. 8. Click on the desired background colour, then click on .
Defining Cus tom Colours
1. Click on Def ine Custom C olours to open the colour fie ld. 2. Click on an d drag the po inter to select custom colour a . 3. Click on an d drag the br ightness slider lighten or dark to en the colour . 4. Click on Ad d to Custom Colours to ad new colour to d the the custom co lours options.
9. Click on settings.
to accept the new preference
22
LOADING THE FILM HOLDER
Using the included 35mm negative and slide holders, the Minolta Dimâge Scan Dual can scan mounted or unmounted... · 35mm colour negatives · 35mm colour slides · 35mm black & white negatives · 35mm black & white positives Advanced Photo System negatives and slides can also be scanned using the optional AD-10 APS Adapter. See page 57.
Loading the Negative Holder
1. Open the film holder. 2. Place the film in the film holder emulsion side down.
· The film holder will accept film strips up to 6 frames long. · Brush dust off the film before placing it into the film holder.
The frame nu mbers and text are back wards when the film's emul sion side is up.
3. Align the frames within the scanning windows.
4. Snap the film holder closed.
Dimâge Scan Dual
23
LOADING THE FILM HOLDER
Loading the Slide Holder
Insert slides into the slide holder emulsion side down.
· Brush dust off the the slide before placing it into the film holder. · Slide mounts must be thicker than 1 mm and thinner than 2 mm to fit into the slide holder. · Orient the slides horizontally, not vertically.
Do not scan gl ass mounted slides. Glass mounts bend the light from the line scanner, prod ucing bad results.
24
INSERTING THE FILM HOLDER INTO THE SCANNER
The notches in the film and slide holders identify the position of the scanning windows. Push the holder in all the way in to scan the last frame on that side of the film holder. Remove, flip, then reinsert the film holder to scan the frames on the other side of the holder.
Insert the negative holder into the scanner's film slot to scan frames 1, 2, or 3.
· Frames 1 or 2 with the slide holder.
The white should be up rig
ht.
mark
Remove, flip, then reinsert the negative holder to scan frames 4, 5, or 6.
· Frames 3 or 4 with the slide holder. · The blue mark should be upright
Dimâge Scan Dual
25
SETTING THE FILM TYPE / PRESCAN
Setting the type of film you are scanning is necessary to accurately reproduce the image. When 35mm film is being scanned, select colour negative, colour positive, black & white negative, or black & white positive. Refer to pages 54-62 when you are scanning Advanced Photo System film.
Select the type of film you are scanning from the film type dropdown list.
· The selected film type will be displayed in the film type window. · Refer to pages 54-62 if you are scanning an APS film type.
Prescan
Click on to preview the image. The prescanned image will appear in preview window.
· The indicator lamp blinks slowly (0.5 Hz) during prescan.
Press the optio n key when clicking on to improve th e colour accuracy of th e prescan image.
· The film will be prescanned twice. The first scan will set the exposure . The second prescans the image.
· The Preview and Control windows can be moved to any convenient location on the screen. Grab the title bar to move the preview or control windows.
26
SELECTING THE USAGE MODE
Standard mode has three image usage options to simplify operation of the Dimâge Scan Dual for beginners. Screen Paste Print Image will be viewed on a monitor (image data base or home page). Image will be imported into a word processing document. Image will be printed or modified using Photoshop or PhotoDeluxe.
1. Click on the option button for the desired usage mode.
Screen
2. Select the desired image size from the image size drop-down list.
· When selected, your image will be scanned at a 96 dpi resolution.
The table below lists the display size for each image size in the drop-down list for monitors with a screen resolution of 72 dpi. Image Size (pixels) 384 x 256 640 x 480 768 x 512 800 x 600 1024 x 768 1280 x 1024 3504 x 2336 Approx. Screen Image Size 4.83 x 3.56 in. 8.89 x 6.67 in. 10.67 x 7.11 in. 11.11 x 8.33 in. 14.22 x 10.67 in. 17.78 x 14.22 in. 48.67 x 32.44 in. Approx. File Size 263K 907K 1.2MB 1.4MB 2.3MB 3.9MB 24.2MB
Continued on the following page. Dimâge Scan Dual
27
SELECTING THE USAGE MODE
Paste
2. Select the word processing document's paper size from the paper size drop-down list.
3. Click on the landscape (horizontal) or portrait (vertical) print orientation option button.
· Image orientation only affects the orientation of the prescan and scanned images. Set the correct paper orientation in your printer driver and word processing application.
4. Click on the desired image size option button.
· The actual size of the image depends on the paper size selected in step 2. · The image will be scanned at a resolution of 96 dpi. · The page orientation icon changes according to the image size selected.
Print
2. Select a paper size from the paper size dropdown list.
· Image orientation only affects the orientation of the prescan and scanned images. Set the correct paper orientation in your printer driver.
3. Click on the landscape (horizontal) or portrait (vertical) print orientation option button. 4. Click on the desired image size option button.
· The actual size of the image depends on the paper size selected in step 2. · The image will be scanned at a resolution of 180 dpi.
28
ORIENTING THE IMAGE
Rotate
Click on the and buttons to correct the orientation of your image before scanning. Changes will be reflected in the preview image.
· Click on to view the image inside the cropping window full screen.
Click on to rotate the image 90° clockwise.
Click on to rotate the image 90° counter-clockwise.
Continued on the following page. Dimâge Scan Dual
29
ORIENTING THE IMAGE
Flip
The and buttons let you flip the image left to right or top to bottom before scanning. Changes will be reflected in the preview image.
· Click on to view the image inside the cropping window full screen.
Click on
to flip the image top to bottom.
· The image is upside down compared to the original prescan.
Click on
to flip the image left-to-right.
· Image is backwards compared to the original scan.
30
ORIENTING THE IMAGE
Cropping
The cropping frame is the box surrounding the image area you want to scan. The height to width ratio of the scan area is fixed in standard mode. Use precision mode when you want to change the height to width ratio of the scanning area .
· Click on to view the image inside the cropping window full screen.
To enlarge or reduce the size of the cropping frame... Click on the corners and drag...
or click on sides and drag.
To move the cropping frame... Click on the inside of the cropping frame and drag.
Click on or to enlarge or re duce the image in the preview window. Click on to move an enlarged image.
Dimâge Scan Dual
31
VARIATION DIALOG BOX NAMES OF PARTS
The variation dialog box lets you quickly correct the brightness and contrast of your image by clicking on simulations that represent varying amounts correction to your image. Correct the colour by clicking on the colour you want to add to your image.
· Click on to view a full screen display of the control and preview windows.
1. Click on
in the preview window.
The Variation dialog box will appear.
1. RGB levels 2. Colour picker 3. Control image 4. Brightness Level 5. Full-screen display button 6. Reset button 7. Contrast level 8. Contrast-level slider
9. Status window 10. Brightness slider 11. Image simulation windows 12. Preview image 13. Help button 14. Cancel button 15. OK button
32
IMAGE CORRECTION VARIATION
Adjusting the Brightness and Contrast
The image simulation windows map contrast and brightness changes to the preview image. The windows display a one step change in the brightness and contrast, but up to 10 steps (+/-) can be applied. The current colour, brightness, and contrast changes are automatically applied to the preview image
2. Click on the appropriate window or move the sliders to increase or decrease the contrast and/or brightness.
· The changes are automatically applied to the preview image. · Additional contrast and brightness simulations will be mapped around the center image.
Correcting th e brightness an d contrast may eliminate the need for colour correc tions.
Adjusting the Colour
The colour picker consists of a colour map and a pointer. Adjust the colour of your image +/ 20 points in any direction by clicking on any colour tone within the colour map. Colour corrections at the edge of the colour map are more saturated (stronger). Colour corrections closer to the center are less saturated. Colour corrections are automatically applied to all of the image simulations.
3. Place the colour correction you want to apply to your image within the the cursor, then click the mouse button.
· The pointer will move to the new position on the colour map. · The RGB correction values are displayed to the right of the colour picker.
Cursor Pointer
4. Click on
· Click on · Click on corrections.
to apply the changes to your scan.
to cancel all corrections and start over. to close the variations window without applying any
Dimâge Scan Dual
33
SCANNING AND SAVING THE IMAGE
When you have finished making all the desired adjustments to the image, you are ready to scan the film.
1. Click on
.
· The cursor will change to an hourglass and a progress bar will appear. · To cancel the scan, click on or press the escape key until the Cancelling Operation message box appears.
Do not remove the film holder until the scan is finished. Interfering with the scanner during scan could result in image distortion.
2. Click on to exit the Dimâge Scan Dual driver software. The image will be opened in your photo application software.
· The driver window will automatically close after each scan if "Close driver after scanning" was selected in the preferences dialog box.
3. Save the image using the instructions from your photo application software.
Multiple imag es can be scanned befo re closing the software if Pho toshop is the host softw are. PhotoDeluxe, Corel DRAW and Corel Pho topaint can only acquire on e image at a time.
4. Remove the film holder from the scanner.
34
P R E C I S I O N O P E R AT I O N
SCAN FLOW
Launch the Software
Set Preferences
Load the Film Holder
Insert the Film Holder
Specify the Film Type
Prescan Orient the Image
Set the Resolution
Correct the Brightness, Contrast, and Colour
Scan
Save
PRECISION OPERATION STARTUP
Launch the Software
1. Turn on the Minolta Dimâge Scan Dual, then turn on your PC. 2. Launch Adobe Photoshop. 3. Select File > Import > Select TWAIN_32 Source...
· The select source dialog box will appear.
4. Click on DS_Dual, then click on . 5. Select File > Acquire > TWAIN_32.
· The Minolta Dimâge Scan Dual control and preview windows appear after initialization is complete.
The startup pr ocedure on pages 16 and 17 can also be us ed
Set the Preferences
1. Click on to open the preferences dialog box.
· The preferences dialog box will open.
2. Click on the Precision mode option button. 3. Specify the default input resolution, output resolution, and units settings from the drop-down lists.
· We recomm end setting th e default input resolution to the highest resolu tion your outp ut device (printe r etc.) can handle.
4. Click on settings.
to accept the new preference
36
PRECISION CONTROL WINDOW NAMES OF PARTS
The precision mode control window will appear with the preview window.
1. Input size text box 2. Magnification window 3. Output size text box 4. Load scan settings button 5. Save scan settings button
6. Units list box 7. Lock buttons 8. Output resolution list box 9. Input resolution list box
Dimâge Scan Dual
37
LOADING AND PRESCAN
Load and insert the film holder.
The white should be up rig
ht.
mark
Specify the film type.
Click on
.
Press the optio n key when clicking on to improve th e colour accuracy of th e prescan image.
· The film will be prescanned twice. The first scan will set the exposure . The second prescans the image.
· The indicator lamp blinks slowly (0.5 Hz) during prescan.
38
ORIENTING THE IMAGE
Rotate, flip, and crop the image as desired.
Click on the corners of the cropping frame to resize the scan area proportionally.
Click on the sides of the cropping frame to resize the scan area non-proportionally.
Dimâge Scan Dual
39
SETTING THE RESOLUTION
Image resolution is the number of pixels per inch (ppi or dpi) that represent your scanned image. Image size and resolution determine the size of your image file. Lower input resolutions result in shorter scan times. Higher input resolutions make larger output sizes and higher output resolutions possible. The rule to follow when scanning is, "bigger is better". We recommend you set the output resolution to the highest value your output device (printer, monitor, etc.) can handle. The input resolution will vary with the size of the scan area, magnification, and output size.
1. Select the desired output resolution from the output resolution drop-down list.
· Values can also be entered directly to the output resolution list box. · This menu is dimmed and cannot be accessed when the units menu is set to pixels.
2. The dimensions of the cropping frame are displayed in the input size text boxes.
· Values can also be entered directly to the input size list boxes. · The values will change if a different unit of measure is selected.
3. Enter the desired output size (maximum 3 digits).
· The output size is limited by the maximum resolution of the scanner. · The values will change if a different unit of measure is selected. · The output size windows are dimmed when the units menu is set to pixels.
4. The input resolution list box displays the lowest input (scan) resolution necessary to achieve the desired output size and resolution.
· Input scan resolutions can also be selected from the drop-down list or entered directly into the input resolution list boxes.
· Click on to lock the inpu t size settings. The icon will change to . Click again to unlock. · The magnific ation window displays the ou tput/input size ratio as a perc entage.
40
RESOLUTION NOTES
Resolution and Output Size
Output resolution is determined by hardware. The Dimâge Scan Dual driver software automatically determines the correct scan resolution to obtain the desired output size and resolution. To determine the final dimensions of a displayed or printed image yourself, multiply the dimensions of the scan area by the scan resolution (input resolution), then divide by the resolution of the output device (output resolution).
Resampling Up
Resampling up occurs when pixel values are interpolated to create an output resolution higher than the input resolution value. Resampling up generally results lower image quality. Users of the Dimâge Scan Dual need to be aware of resampling because image corrections entered in the driver software are applied after the image has been scanned and sent to the CPU. Resampling up will occur when the scanner's output resolution is set higher than the input resolution at magnification greater than 100.
Incorrectly Scanned Image
Correctly Scanned Image
Dimâge Scan Dual
41
SCAN SETTINGS SAVE AND LOAD
button in the precision control window saves the resolution, scan area, magnification, and units settings to a data file. The button lets you retrieve those settings and apply them to a new image The
Saving Scan Settings
1. Click on .
· The resolution, scan area, magnification, and units settings are saved to a data (dat) file.
The save file dialog box will appear.
2. Enter a file name and the location to save the file, then click on .
Loading Scan Settings
1. Click on . The open file dialog box will appear. 2. Select the data file you want to use, then click on .
· The settings in the selected file are applied to the current image.
The scan sett ings files for colou r and black and wh ite film are not interc hangeable.
42
HISTOGRAM DIALOG BOX NAMES OF PARTS
The histogram dialog box displays the frequency of occurrence of the 256 levels of brightness for each of the colour channels that make up the image area inside the cropping frame. Level 0 is minimum brightness. Level 255 is maximum brightness. The midtones fall in-between.
· The histograms represent the red, green, and blue brightness levels for the control image. Click on to view the histograms for the preview image. and hold
Click on
in the preview window. The Histogram dialog box will appear.
1. Control image 2. White point button 3. Black point button 4. Gray point button 5. Output histogram button 6. RGB synchro button 7. Load settings button
8. Save settings button 9. Shadow sliders 10. Midtone slider 11. Highlight sliders 12. Output level sliders 13. Input level sliders 14. Preview image
Continued on the following page. Dimâge Scan Dual
43
IMAGE CORRECTION HISTOGRAM
Setting the White, Black, and Gray Points
Properly setting an image's white and black points will usually correct the colour cast and midtone distribution.
· Changes are automatically applied to the preview image.
1. Click on , then click on the tone in the control image that should be scanned as the brightest neutral white in your image.
· The cursor will change to . · The RGB brightness values of the selected tone will be changed to 255.
2. Click on , then click on the tone in the control image that should be scanned as the darkest neutral black in your image.
· The cursor will change to . · The RGB brightness values of the selected tone will be changed to 0.
3. Click on , then click on the tone in the control image that should be scanned as middle gray.
· The cursor will change to . · The RGB brightness values of the selected tone will be changed to 127.
Setting the gr ay point is not necess ary for most images.
44
IMAGE CORRECTION HISTOGRAM
Using the Histogram Sliders - RGB Synchro
When RGB synchro is selected, moving the levels sliders remaps the pixel values without changing the colour balance. Correcting the highlight and shadow values with the histogram sliders, may produce better results on images without neutral highlights or shadows.
If the histogram contains large flat line areas... 1. Click on .
If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Diplodocs provides you a fast and easy access to the user manual MINOLTA DIMAGE SCAN DUAL. MINOLTA offer a product for which we do not have the user manual? Let us know what you are looking for: site Internet, histoire, actualité, filiales, site Internet, mode d'emploi, driver, avis des utilisateurs, meilleur prix des produits, forum d'assistance aux problèmes, annuaire des marques, annuaire des constructeurs, répertoire des marques, répertoire des constructeurs, site Internet de la marque, site Internet du constructeur Diplodocs allows you to download user manual MINOLTA DIMAGE SCAN DUAL, user guide MINOLTA DIMAGE SCAN DUAL, instructions MINOLTA DIMAGE SCAN DUAL, owner's manual MINOLTA DIMAGE SCAN DUAL, online manual MINOLTA DIMAGE SCAN DUAL.Access web reviews MINOLTA DIMAGE SCAN DUAL, MINOLTA QMS, MINOLTA-QMS, MINOLTA/QMS, Photocopier & Copier. |
![]() |
Include the add-on to download manuals from your site, forum or blog | ![]() |
Frequently Asked Questions | ![]() |
Contact Diplodocs team | ![]() |
Last searches Last additions |
![]() |
Sitemap | ![]() |
|||
| Brands starting with A B C D E F G H I J K L M N O P Q R S T U V W X Y Z # | |||||||||||||
|
|
Copyright © 2005 - 2008 - Diplodocs -
All Rights Reserved. Designated trademarks and brands are the property of their respective owners. |