User manual NETGEAR EN104 - INSTALL GUIDE
Diplodocs help download the user guide NETGEAR EN104 - INSTALL GUIDE.
You may also download the following manuals related to this product:
Preview of the first 3 pages of manual
You either have JavaScript turned off or an old version of Adobe Flash Player Get the latest Flash Player.
User guide NETGEAR EN104 - INSTALL GUIDE
Detailed instructions for use are in the User's Guide. Start Here
Congratulations on your purchase of the NETGEARTM Model EN104, Model EN108, or Model EN116 Ethernet hub. The hubs deliver standards-based, plugand-play networking solutions for small businesses, home offices, and lowdensity workgroups of larger companies. In this installation guide, all three hubs are referred to collectively as the Model EN104/EN108/EN116 hub. Each hub is listed individually when information is provided that refers to a specific model.
Features
The Model EN104/EN108/EN116 hub has the following features: · Four (on the Model EN104 hub), eight (on the Model EN108 hub), and sixteen (on the Model EN116 hub) vista 10BASE-T network ports (RJ-45) that provide 10 megabit per second (Mbps) networking using simple unshielded twisted pair (UTP) wiring Built-in LED indicators for at-a-glance status checks by vista networks ports AUI (not on the Model EN104 hub) or coaxial BNC backbone support for connecting to an existing Ethernet segment or external transceiver, or for network expansion by connecting multiple hubs together using twisted pair or coaxial cabling Uplink port for connecting to other hubs using simple straight-through cables Clear front-panel light-emitting diode (LED) indicators to monitor overall hub status Plug-and-play installation with no software to configure Complete hub functions including packet retiming, collision detection, preamble regeneration, and fragment extension Automatic partitioning and reconnection of a port that has excessive collisions or is jabbering Automatic polarity detection for recognizing and correcting incorrect polarity on the receive pair Compact design, enabling easy tabletop or rack-mounting installation External power adapter Limited lifetime warranty on the unit and three-year warranty on the power supply
· ·
· · · · · · · · ·
Model EN104/EN108/EN116 Ethernet Hub Installation Guide
Package Contents
Model EN104 hub
10 BASE-T HUB
Model EN108 hub or
10 BASE-T HUB
EN104
LINK Rx
Pwr Col
EN108
LINK
Rx
Pwr Col
1
2
3
4
5
6
7
8
or Model EN116 hub
10 BASE-T HUB
Pwr Col
EN116
LINK
Rx
1
2
3
4
5
6
7
8
1
2
3
4
5
6
7
8
Power adapter Mounting kit
Installation guide, Warranty & Owner Registration Card, Support Information Card
8731FA
Verify that your package contains the following: · · · · · · · Model EN104 hub, Model EN108 hub, or Model EN116 hub Mounting kit (for wall installation) BNC T-connector and BNC 50 terminator (only if you have purchased the Model EN108 hub or the Model EN116 hub) This installation guide Warranty & Owner Registration Card Support Information Card Power adapter
Model EN104/EN108/EN116 Ethernet Hub Installation Guide
Product Illustration
Front Panel of the Model EN104 hub 10BASE-T ports
Pwr (Power) Col (Collision)
10 BASE-T HUB
EN104
LINK Rx
Pwr Col
Normal/Uplink push button
Front Panel of the Model EN108 hub
10 BASE-T HUB
Pwr Col
EN108
LINK
Rx
1
2
3
4
5
6
7
8
Front Panel of the Model EN116 hub
10 BASE-T HUB
Pwr Col
EN116
LINK
Rx
1
2
3
4
5
6
7
8
1
2
3
4
5
6
7
8
8732FA
Vista 10BASE-T Network Ports with Built-in LEDs
The front panel of the Model EN104 hub has four RJ-45 10BASE-T ports, the Model EN108 hub has eight RJ-45 10BASE-T ports, and the Model EN116 hub has sixteen RJ-45 10BASE-T ports. Two LEDs--the Link LED and the Rx LED--are built into each 10BASE-T port.
Link LED Rx LED
8724EA
Model EN104/EN108/EN116 Ethernet Hub Installation Guide
LEDs
The table below describes the activity of the LEDs.
Label Pwr (Power) Col (Collision) Color Green Amber Activity Description On Blinking Power is supplied to the hub. Data collision is occurring on the network. Note that occasional collisions are normal. The link between this port and the connected device is good.
Link (located on the top left corner of each vista 10BASE-T port) Rx (located on the top right corner of each vista 10BASE-T port) Active (for BNC) Rx (for BNC) Active (for AUI) Rx (for AUI)
Green
On
Green
Blinking
There is incoming data on the port.
Green Green Green Green
On Blinking On Blinking
The link between the BNC port and the connected device is good. There is incoming data on the BNC port. The link between the AUI port and the connected device is good. There is incoming data on the AUI port.
Normal/Uplink Push Button
The Normal/Uplink push button allows you to select Normal (MDI-X) wiring for direct PC connection. The push button also allows you to select Uplink (MDI) wiring for connection to a hub or a switch through port 4 on the Model EN104 hub, port 8 on the Model EN108 hub, or port 16 on the Model EN116 hub. This uplink configuration eliminates the need to use a crossover cable. The other 10BASE-T ports are permanently configured for normal wiring for connection to a PC.
Model EN104/EN108/EN116 Ethernet Hub Installation Guide
Rear Panel
The rear panel of the hub has a BNC port that you can use to connect to a backbone network or other PCs using thin coaxial cable. The rear panel of the Model EN108 hub and the Model EN116 hub also has an AUI port in addition to the BNC port. You can use the AUI port with the appropriate transceiver to connect the hub to a backbone network using thin coaxial cable, thick coaxial cable, fiber optic cable, or 10BASE-T wiring. The rear panel also includes a DC power receptacle.
BNC port LEDs BNC port
Active Rx
BNC
12Vdc 1.2A
--
+
Rear Panel of the Model EN104 hub AUI port LEDs AUI port Power receptacle
Active Rx
AUI
Active Rx
BNC
12Vdc 1.2A
--
+
Rear Panel of the Model EN108 hub
Active Rx
AUI
Active Rx
BNC
12Vdc 1.2A
--
+
Rear Panel of the Model EN116 hub
8738FA
Model EN104/EN108/EN116 Ethernet Hub Installation Guide
Installation Procedures Prepare the Site
Before you begin installing your hub, prepare the installation site. Make sure your operating environment meets the operating environment requirements of the equipment.
Characteristic Temperature Requirement Ambient temperature between 0° and 40° C (32° and 104° F). No nearby heat sources such as direct sunlight, warm air exhausts, or heaters. Maximum relative humidity of 90%, noncondensing. Minimum 2 inches (5.08 cm) on all sides for cooling. Adequate airflow in room or wiring closet. At least 6 feet (1.83 m) to nearest source of electromagnetic noise (such as photocopy machine or arc welder). Minimum 12 inches (19.68 cm) front and back for service access and maintenance. Front and back clearance for cables and wiring hardware such as punchdown blocks. Adequate power source within 6 feet (1.83 m). Wiring hardware, such as punchdown blocks or patch panels, should be complete before installing the hub.
Operating humidity Ventilation Operating conditions Service access
Power Wiring hardware
Install the Hub
To install your hub on a flat surface, you do not need any special tools. Be sure the hub is positioned with at least 2 inches of space on all sides for ventilation. To install the hub on a wall, measure the distance between the mounting holes on the back of the hub and mark the wall to match the location of the mounting holes on the hub. At the marked location, screw into the wall the two screws that you received with the mounting kit included in your package contents. Be sure to choose a location that is near the devices to be
connected, is close to an electrical outlet, and provides at least 2 inches of space all around the hub for ventilation.
Model EN104/EN108/EN116 Ethernet Hub Installation Guide
Connect a PC to the Hub
You can connect PCs, Apple Macintosh computers, UNIX workstations, or any device equipped with a 10BASE-T Ethernet interface to the RJ-45 ports on your hub by using twisted pair Ethernet cables. To connect any of the RJ-45 ports on your hub to a PC, use a regular straightthrough UTP cable. If you are connecting using port 4 on the Model EN104 hub, port 8 on the Model EN108 hub, or port 16 on the Model EN116 hub, set the Normal/Uplink push button to Normal.
(The Model EN108 hub is shown in the illustration.)
Pwr Col
1 2 3 4 5 6 7 8 Normal/U plink
8734FA
Note: Ethernet specifications limit the cable length between your PC or server and the hub to 328 feet (100 meters) in length.
Model EN104/EN108/EN116 Ethernet Hub Installation Guide
Connect the Hub to a Network
Cascading refers to connecting hubs together to increase the number of ports or the number of users supported on the network. The 10BASE-T ports can be used to cascade hubs together. The twisted pair cable extended from a 10BASE-T port (or UTP port) is called a twisted pair segment and can be up to 100 meters (m) in length. The 10BASE-T ports, with the exception of port 4 on the Model EN104 hub, port 8 on the Model EN108 hub, or port 16 on the Model EN116 hub, are MDI-X (or Normal) ports. Use the following table as a guide for selecting the appropriate network cable.
Connecting Port on the Hub Model EN104 hub: Ports 13 Ports 13 Model EN108 hub: Ports 17 Ports 17 Model EN116 hub: Ports 115 Ports 115 PC, server, or router Hub or switch Straight-through cable Crossover cable PC, server, or router Hub or switch Straight-through cable Crossover cable PC, server, or router Hub or switch Straight-through cable Crossover cable Connecting Device Cable Used
Set the Normal/Uplink Push Button
If you are connecting to port 4 on the Model EN104 hub, port 8 on the Model EN108 hub, or port 16 on the Model EN116 hub, use the following table. Determine the type of cable to use and how to set the Normal/Uplink push button.
Connecting Port Connecting Device Cable Used Straight-through cable Straight-through cable
Port 4, port 8, or port 16 set to PC, server, or router Normal Port 4, port 8, or port 16 set to Hub or switch Uplink
Model EN104/EN108/EN116 Ethernet Hub Installation Guide
Cascade the Hub
The following illustration shows cascading hubs together in a hierarchical star through the 10BASE-T ports and indicates the setting of the Normal/Uplink push button on each hub.
Hub 1
10 BASE-T HUB
Pwr Col
EN116
LINK
Rx
1
2
3
4
5
6
7
8
1
2
3
4
5
6
7
8
Normal
Hub 2
10 BASE-T HUB
Hub 3
10 BASE-T HUB
Pwr Col
EN108TP
Pwr
EN108TP
1
2
3
4
5
6
7
8
Uplink
Col
1
2
3
4
5
6
7
8
Uplink
Hub 4 Uplink
Hub 5 Uplink
A
B
8735FA
Note: Ethernet specifications limit the number of hubs with twisted pair links in any communication path to five, as shown in the example. When PC "A" communicates with PC "B," the communication path goes from hub 4 to hub 2, to hub 1, to hub 3, and then to hub 5.
The following illustration shows cascading hubs together daisy-chain style and indicates the setting of the Normal/Uplink push button on each hub.
Model EN104 hub
10 BASE-T HUB
EN104
LINK Rx
Pwr Col
Normal
Model EN108 hub
10 BASE-T HUB
Pwr Col
EN108
LINK
Rx
1
2
3
4
5
6
7
8
Uplink
Model EN116 hub
10 BASE-T HUB
Pwr Col
EN116
LINK
Rx
1
2
3
4
5
6
7
8
1
2
3
4
5
6
7
8
Uplink
8733FA
Model EN104/EN108/EN116 Ethernet Hub Installation Guide
Connect to a Network Using the BNC Port
The BNC port on the rear panel of the hub is used for connecting to a thin coaxial segment. You can connect other Model EN104/EN108/EN116 hubs, servers, workstations, or other devices to the BNC port. A BNC-T connector is inserted in the port, and the 50 terminator terminates the connection at each end device. By using the BNC port for cascading, you treat each connected hub as just another node on the coaxial segment. The separation marks in the coaxial cable between the hubs in this illustration represent the incorporation of other devices and show that interconnection is not limited to hubs.
BNC T- connector
Model EN104 hub BNC 50 terminator
Model EN108 hub
Model EN116 hub
BNC 50
terminator
8736FA
Note: Ethernet specifications limit a BNC segment to 30 BNC connections, specify a minimum of 1.64 feet (0.5 m) between any two stations, and limit segments to 607 feet (185 m) in length.
Model EN104/EN108/EN116 Ethernet Hub Installation Guide
Connect to a Network Using the AUI Port
The AUI port on the rear panel (found only on the Model EN108 hub and the Model EN116 hub) is normally used for connecting a thick coaxial segment. With the right type of transceiver, you can use the AUI port to connect to most types of network media, including 10BASE-T twisted pair cable or thin coaxial, thick coaxial, and 10BASE-FL fiber optic cables.
Note: All transceivers connected to the AUI port must have the signal quality error (SQE) test function disabled. Refer to your transceiver documentation for information about disabling the SQE test function.
Cable terminator device AUI cable
Thick coaxial cable
10BASE-5 transceiver Model EN108 hub and Model EN116 hubs
8737FA
Note: Ethernet specifications limit thick coaxial segments to 100 stations and 1,640 feet (500 m) in length, and they specify that the AUI cable between the hub and the transceiver is limited to 164 feet (50 m).
Model EN104/EN108/EN116 Ethernet Hub Installation Guide
Verify Installation
To complete the installation, connect the power cord first to the power receptacle on the hub rear panel and then to the power outlet on the wall. When power has been applied to the hub: · · · · The green Pwr (Power) LED on the front panel is on. The green Link LED on each connected port is on. The green Active LED on each connected AUI port is on. The green Active LED on each connected BNC port is on.
If encounter any problems, refer to "Troubleshooting" on page 4.
Model EN104/EN108/EN116 Ethernet Hub Installation Guide
Troubleshooting
Symptom Amber Col LED blinks. Amber Col LED blinks excessively. Cause There is data collision on the network. There is data collision on the network because the network is extremely busy or defective devices are connected on the network that cannot detect network traffic or collision. Wrong or miswired cables are used. Solution Data collision is normal on Ethernet networks. No action is required. Make sure connected devices are operating in half-duplex mode. The hub is not compatible with devices that operate in full-duplex mode. If you suspect that there might be a defective device on the network, disconnect devices one at a time to isolate the defective unit on the network. If the network is extremely busy, you may have to segment the network with an Ethernet switch such as a NETGEAR Ethernet switch or to upgrade your network to Fast Ethernet operation.
Make sure the correct UTP cables are used. See the table in the installation section of this guide for cable use and Normal/Uplink push button information. Note that home telephone cables can cause a collision condition and cannot be used in place of UTP cables. Check for a bad cable, cable pairs that are not correctly wired, or loose connectors. Make sure that there is power to both the hub and the Ethernet transceiver on the connected device. Check for a bad cable, cable pairs that are not correctly wired, or loose connectors. Make sure that there is power to both the hub and the Ethernet transceiver on the connected device. Make sure that each segment is terminated with a BNC 50 terminator at both ends. Check for a bad cable.
Green Link LED The port is not is off when a detecting a cable is attached. successful link. Green Link LED is not blinking when there is data transmission. The port is not detecting data transmission.
Green Active The port is not LED on the BNC detecting a port is not on successful link. when the port is connected. The port is not Green Rx LED on the BNC port detecting data transmission. is not blinking when there is data transmission. Green Active LED on the AUI port is not on when the port is connected. The port is not detecting a successful link.
Check for a bad cable or loose connectors. Make sure that there is power to both the hub and the connected device.
Make sure that the AUI transceiver is functioning properly, the coaxial segment is terminated correctly, the segment is not disconnected along the cable length, and the signal quality error (SQE) test on the transceiver is disabled. Refer to your transceiver documentation for instructions on setting the SQE. Check for a bad cable or loose connectors. Make sure that there is power to both the hub and the connected device.
Green Rx LED The port is not on the AUI port is detecting data not blinking when transmission. there is data transmission.
Model EN104/EN108/EN116 Ethernet Hub Installation Guide
Network Interface Cards
Make sure the network interface cards installed in the workstations are in working condition and the software drivers have been installed.
Hub Integrity
If required, verify the integrity of the hub by resetting it. Turn power to the hub off and then back on. If the problem continues and you have completed all the preceding diagnoses, contact NETGEAR Customer Support. For the phone number of the representative in your area, refer to the Support Information Card.
Model EN104/EN108/EN116 Ethernet Hub Installation Guide
Technical Specifications
General Specifications Network Protocol and Standards Compatibility IEEE 802.3i, 10BASE-T, 10BASE-2, 10BASE-5 Ethernet Data Rate Interface 10 Mbps, Manchester encoded 10BASE-T ports (RJ-45), BNC port, AUI port (Model EN108 hub and Model EN116 hub only) 11.0 W 16.5 W 20.5 W 7.5 V DC@ 1A max. 12 V DC @ 1.2A max. 12 V DC @ 1.2A max.,
Max. Power Consumption Model EN104 hub Model EN108 hub Model EN116 hub DC Output Voltage (Power Adapter): Model EN104 hub Model EN108 hub Model EN116 hub Physical Specifications Dimensions: Model EN104 hub Model EN108 hub Model EN116 hub Weight: Model EN104 hub Model EN108 hub Model EN116 hub Environmental Specifications Operating temperature: Operating humidity: Electromagnetic Complience CE mark, commercial FCC Part 15 Class A EN 55 022 (CISPR 22), Class A VCCI Class A C-Tick Safety Agency Approvals for Power Adapter CE mark, commercial UL listed (UL 1950) CUL TUV licensed (EN 60 950)
T-Mark
3.7 by 4.0 by 1.1 in. 94 by 101 by 28 mm 6.2 by 4.0 by 1.1 in. 158 by 101 by 28 mm 11.3 by 4.0 by 1.1 in. 286 by 101 by 28 mm 0.74 lb (0.34 kg) 1.17 lb (0.53 kg) 1.97 lb (0.89 kg) 0° to 40° C (32° to 104° F) 90% maximum relative humidity, noncondensing
Model EN104/EN108/EN116 Ethernet Hub Installation Guide
Replacement Power Adapter
If, for any reason, the power adapter for any of the hubs fails, contact NETGEAR immediately to order a replacement adapter. Use the following table when ordering a specific power adapter.
Order code PWR-024-001 PWR-024-002 PWR-024-003 PWR-024-004 PWR-024-005 Order code PWR-002-004 PWR-002-005 PWR-002-006 PWR-002-008 PWR-002-010 EN104 Power adapter (7.5 V DC, 1 A), North America Power adapter (7.5 V DC, 1 A), Europe Power adapter (7.5 V DC, 1 A), United Kingdom Power adapter (7.5 V DC, 1 A), Australia Power adapter (7.5 V DC, 1 A), Japan EN108, EN116 Power adapter (12 V DC, 1.2 A), North America Power adapter (12 V DC, 1.2 A), Japan Power adapter (12 V DC, 1.2 A), Europe Power adapter (12 V DC, 1.2 A), United Kingdom Power adapter (12 V DC, 1.2 A), Australia
Model EN104/EN108/EN116 Ethernet Hub Installation Guide
© 2000 by NETGEAR, Inc. All rights reserved.
Trademarks
NETGEARTM is a trademark of NETGEAR, Inc. Windows® is a registered trademark of Microsoft Corporation. Other brand and product names are trademarks or registered trademarks of their respective holders. Information is subject to change without notice.
Statement of Conditions
In the interest of improving internal design, operational function, and/or reliability, NETGEAR reserves the right to make changes to the products described in this document without notice. NETGEAR does not assume any liability that may occur due to the use or application of the product(s) or circuit layout(s) described herein.
Certificate of the Manufacturer/Importer
It is hereby certified that the NETGEAR Model EN104 hub, Model EN108 hub, and Model EN116 hub have been suppressed in accordance with the conditions set out in the BMPT-AmtsblVfg 243/1991 and Vfg 46/ 1992. The operation of some equipment (for example, test transmitters) in accordance with the regulations may, however, be subject to certain restrictions. Please refer to the notes in the operating instructions. Federal Office for Telecommunications Approvals has been notified of the placing of this equipment on the market and has been granted the right to test the series for compliance with the regulations.
Voluntary Control Council for Interference (VCCI) Statement
This equipment is in the first category (information equipment to be used in commercial and/or industrial areas) and conforms to the standards set by the Voluntary Control Council for Interference by Data Processing Equipment and Electronic Office Machines that are aimed at preventing radio interference in commercial and/ or industrial areas. Consequently, when this equipment is used in a residential area or in an adjacent area thereto, radio interference may be caused to equipment such as radios and TV receivers.
Federal Communications Commission (FCC) Compliance Notice: Radio Frequency Notice
Note: This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to Part 15 of the FCC rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment. This equipment generates, uses, and can radiate radio frequency energy. If it is not installed and used in accordance with the instruction manual, it may cause harmful interference to radio communications. Operation of this equipment in a residential area is likely to cause harmful interference, in which case users will be required to take whatever measures may be necessary to correct the interference at their own expense.
EN 55 022 Statement
This is to certify that the NETGEAR Model EN104 hub, Model EN108 hub, and Model EN116 hub are shielded against the generation of radio interference in accordance with the application of Council Directive 89/336/EEC, Article 4a. Conformity is declared by the application of EN 55 022 Class A (CISPR 22). Warning: This is a Class A product. In a domestic environment, this product may cause radio interference, in which case the user may be required to take appropriate measures.
Canadian Department of Communications Radio Interference Regulations
This digital apparatus (NETGEAR Model EN104 hub, Model EN108 hub, and Model EN116 hub) does not exceed the Class A limits for radio-noise emissions from digital apparatus as set out in the Radio Interference Regulations of the Canadian Department of Communications.
Règlement sur le brouillage radioélectrique du ministère des Communications
Cet appareil numérique (NETGEAR Model EN104 hub, Model EN108 hub, et Model EN116 hub) respecte les limites de bruits radioélectriques visant les appareils numériques de classe A prescrites dans le Règlement sur le brouillage radioélectrique du ministère des Communications du Canada.
Model EN104/EN108/EN116 Ethernet Hub Installation Guide
NETGEAR, Inc. 4500 Great America Parkway Santa Clara, CA 95054 USA Phone: 1-888-NETGEAR E-mail: Support@NETGEAR.com http://www.NETGEAR.com
*M-EN100NA-3*
If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Diplodocs provides you a fast and easy access to the user manual NETGEAR EN104. NETGEAR offer a product for which we do not have the user manual? Let us know what you are looking for: user guide, owner's manual, online manual, operating instructions, quick start guide, mounting instructions, schematics, service manual, installation instructions, RTFM. Diplodocs allows you to download user manual NETGEAR EN104, user guide NETGEAR EN104, instructions NETGEAR EN104, owner's manual NETGEAR EN104, online manual NETGEAR EN104.Access web reviews NETGEAR EN104, , Router, Switch, Firewall & Other network security hardware. |
![]() |
Include the add-on to download manuals from your site, forum or blog | ![]() |
Frequently Asked Questions | ![]() |
Contact Diplodocs team | ![]() |
Last searches Last additions |
![]() |
Sitemap | ![]() |
|||
| Brands starting with A B C D E F G H I J K L M N O P Q R S T U V W X Y Z # | |||||||||||||
|
|
Copyright © 2005 - 2008 - Diplodocs -
All Rights Reserved. Designated trademarks and brands are the property of their respective owners. |