DISCLAIMER TO DOWNLOAD THE USER GUIDE OMRON HEM-711

Click on "Download the user Manual" at the end of this Contract if you accept its terms, the downloading of the manual OMRON HEM-711 will begin.

You agree to use the Manual in accordance with the terms and conditions hereafter described.

1. Our service
Diplodocs offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets...

2. Access rights
The documents available on this site are and will remain properties of their respective owners. Accessing, downloading or storing a document on this site does not give you any right. You certify accessing and storing only documents for which you regularly acquired rights of use, either by owning the item corresponding to the document, or thanks to a right to broadcast the document, given by the copyright owners.

3. Our responsibility
In any way can't Diplodocs be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Diplodocs, for instance, does not offer a translation service.

4. Checking of use
Once downloaded, you must make sure that the Manual matches the Product for which you intend to use it. You agree to remain entirely responsible for the use you do with the instructions contained in the document, no matter whether damages of losses occur following its use.

5. Your commitment
In compensation for using our service, you certify not to harm Diplodocs by any legal action, and to help Diplodocs by promoting the site or uploading new documents. You acknowledge that Diplodocs does not owe you mandatory results or availability.


Diplodocs explicitly forbids the use of its service by anyone who do not agree with all conditions above. By accepting or downloading the Manual OMRON HEM-711, you agree to have read the disclaimer, to have understood all of it and to be bond by its terms and conditions.

You either have JavaScript turned off or an old version of Adobe Flash Player
Get the latest Flash Player.

   

DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

We hope that this OMRON HEM-711 user guide will be useful to you.

Need help, support, reviews, tips or troubleshooting for your OMRON HEM-711 products ?
Discussion, review, tips, troubleshooting issue, problem : search help on OMRON HEM-711 product forum.



close

5 364 brands
1 237 233 user's guides
520 000 members
Domestic Appliance | TV & Audio | Phone | Computer | Car | Digital Camera | Video Game
Search
a brand
A B C D E F G H I J K L M N O P Q R S T U V W X Y Z # Search for a user manual
 

User manual OMRON HEM-711

Diplodocs help download the user guide OMRON HEM-711.

  Download the user manual OMRON HEM-711     
Download the complete
user guide (191 Ko)
Need help, support, reviews, tips or troubleshooting for your OMRON HEM-711 products ?




You may also download the following manuals related to this product:

OMRON HEM-711AC

Preview of the first 3 pages of manual
You either have JavaScript turned off or an old version of Adobe Flash Player
Get the latest Flash Player.




Visit OMRON official site


User guide OMRON HEM-711


R INSTRUCTION MANUAL For Customer Service Call Toll Free Automatic Blood Pressure Monitor with IntelliSenseTM 1-800-634-4350 Model HEM-711 AU MODTOMATIC EL H BLO EM-7 OD P 11 RESS URE SYS MON TOL ITOR IC DIAS TOL IC T UR O RE BAT PLACE E TER IES PRO GRE SS RE ME AD AS Y PULS E/min Manufactured by OMRON Distributed by: OMRON HEALTHCARE, INC. 300 Lakeview Parkway Vernon Hills, Illinois 60061 www.omron.com/ohi Copyright © 2001 OMRON HEALTHCARE, INC. 711INST ON/ OFF STA RT TITLE TABLE OF CONTENTS Introduction........................................................................................4 Notes on Safety.................................................................................5 Know Your Unit..................................................................................6 Quick Reference Guide.....................................................................7 Battery Installation/Replacement ......................................................8 How to Apply the Arm Cuff..........................................................9, 10 How to Take a Reading .............................................................11, 12 How to Use the Memory Function ..................................................13 How to Use the Optional AC adapter..............................................14 Troubleshooting...............................................................................15 Caution ............................................................................................16 Care and Maintenance....................................................................17 Five Year Limited Warranty .............................................................18 Specifications ..................................................................................19 3 INTRODUCTION TITLE Thank you for purchasing the Omron Automatic Blood Pressure Monitor with IntelliSenseTM, HEM-711. Although your blood pressure fluctuates throughout the day, no self-adjustment is necessary as the monitor intelligently adjusts to your changing conditions. The IntelliSenseTM monitor uses fuzzy logic intelligence to sense both your systolic and diastolic blood pressure values, and the result is personalized inflation with every reading. Arm discomfort and misreading due to improper cuff inflation are virtually eliminated. Your new OMRON monitor uses the oscillometric method of blood pressure measurement. This means the monitor detects your blood's movement through your brachial artery and converts the movements into a digital reading. At the push of a button, the monitor automatically fills the cuff with air, starts deflation, then displays your systolic, diastolic, and pulse readings on an extra large display panel. Please read this instruction manual thoroughly before using this unit. For specific information on your own blood pressure, CONTACT YOUR PHYSICIAN. NOTESTITLE ON SAFETY · The warning signs and the sample icons shown here are listed for you to use the product safely and correctly as well as to prevent the risk and the damage to you and others from happening. · The icons and meanings are as follow. Warning sign Contents Indicates matters in which bodily harm or material damage* may arise as a result of incorrect handling. * Material damage refers to a wide range of damage involving your house, household goods, domestic animals, and pets. Examples of signs The icon indicates prohibitions (what you cannot do). Matters involving actual prohibitions are indicated by text or pictures in or near left icon refers to "prohibition to disassemble". . The Caution The icon indicates something compulsory (always follow). Matters involving actual compulsory actions are indicated by text or pictures in or near . The left icon refers to "general compulsion". Caution Self-diagnosis of measured results and treatment are dangerous. Please follow the instructions of your doctor. Do not use the unit on infants or persons who cannot express one's intention. Do not use the unit for any purpose other than measuring blood pressure. Do not use a cellular phone near the unit. Improper operation may result. Do not disassemble, repair, or remodel the main unit or the arm cuff of the blood pressure monitor. The battery liquid may leak and damage the main unit. Please observe the following points. · When you are not going to use the unit for a long period of time (approximately three months or more), take out the batteries. · Replace the worn batteries with new ones immediately. · Do not use worn and new batteries together. · Do not insert the batteries with their polarities in wrong direction. Do not force to bend the arm cuff or the air tube excessively. When removing the air tube, pull at the connector. Do not apply strong shock or drop the main unit. Do not inflate the arm cuff without it being wrapped on the arm. 4 5 KNOWTITLE UNIT YOUR Systolic Blood Pressure Display Heart Symbol QUICK REFERENCE GUIDE TITLE 1. Avoid eating, smoking, and exercising for at least 30 minutes before taking a measurement. 2. Remove tight-fitting clothing from your upper arm. ITOR MON URE ESS D PR LOO TIC B 11 OMA M-7 AUT DEL HE MO IC TOL SYS O YTE AD UR RE AS ME E FF ON/O ON/OFF Button C PLA IES REATTER B SS GRE PRO 3. Sit in a chair with your feet flat on the floor and place your arm on a table so that the cuff is at the same level as your heart. 4. Put your arm through the cuff loop making sure that the bottom edge of the cuff is approximately one-half inch above the elbow and that the Green Marker on the cuff is above brachial artery. 1/2 inch RT STA START Button LIC STO DIA E/min PULS Air Jack Memory Call Button Diastolic Blood Pressure Display / Pulse Display Green Marker Air Plug (Connects to the air jack) 5. Pull the end of the cuff so that the entire cuff is evenly tightened around your arm and press the hook material firmly against the pile side of the cuff. Arm Cuff 6. Press the ON/OFF button. 7. After the Heart Symbol ( ) appears on the digital panel, press the Start button, and remain still until the measurement is complete. Air Tube Green Marker 8. When measurement is complete, the monitor displays your blood pressure and pulse rate, and automatically deflates the cuff. 9. Wait 2-3 minutes before taking another blood pressure measurement. You may require more rest time between readings depending on your individual physiological characteristics. Carrying Case 6 7 BATTERY INSTALLATION/REPLACEMENT TITLE 1. Slide the battery cover off in the direction of the arrow. HOW TO APPLY THE ARM CUFF TITLE 1. If the cuff is assembled correctly, the hook material will be on the outside of the cuff loop and the metal D-ring will not touch your skin. 2. If the cuff is not assembled, pass the end of the cuff furthest from the tubing through the metal Dring to form a loop. The smooth cloth should be on the inside of the cuff loop. 3. Sit in a chair with your feet flat on the floor and place your arm on a table so that the cuff is at the same level as your heart. AU ODEL H M IC TOL SYS LIC STO DIA E/ PULS 2. Install or replace 4 "AA" size batteries so the + (positive) and ­ (negative) polarities match the polarities of the battery compartment as indicated. Pile Side Material Sewn Hook Material 3. Replace the battery cover. D-Ring Notes: If the Low Battery Indicator ( ) appears on the display, replace all four batteries. Long-life alkaline batteries are recommended. Remove the batteries if the monitor will not be used for an extended period of time. 4. Put your arm through the cuff loop. The bottom of the cuff should be approximately 1/2" above the elbow. The Green Marker on the cuff should lie over the brachial artery on the inside of the arm. Tube should run down center of arm approximately even with middle finger. Bottom Edge 1/2 Inch Cuff Tube Green Marker 8 9 HOW TO APPLY THE ARM CUFF TITLE 5. Pull the cuff so that the top and bottom edges are tightened evenly around your arm. 6. When the cuff is positioned correctly, press the sewn hook material FIRMLY against the pile side of the cuff. 7. Make certain the cuff fits snugly around your arm. The cuff should make good contact with your skin. You should be able to fit one finger between the cuff and your arm. 8. Relax your arm and turn your palm upward. 9. Be sure there are no kinks in the air tubing. HOW TO TAKE A READING TITLE 1. Press the ON/OFF button. a) All display symbols appear for approximately one second. b) When the monitor becomes ready to measure, the Heart Symbol appears on the display. 2. Press the START button and remain still. As the cuff begins to inflate, the monitor automatically determines your ideal inflation level. Because this monitor detects the pulse even during inflation, do not move your arm and remain still until the entire measurement completes. Initial LCD Test 3. Inflation stops automatically and measurement is started. As the cuff slowly deflates, decreasing numbers appear on the display and the Heart Symbol ( ) flashes at every heartbeat. In rare circumstances, a higher inflation may be necessary. In those cases, the monitor reinflates the cuff up to 30 mmHg higher than initial inflation and restarts the measurement. Ready to Measure Inflation started. 4. When the measurement is complete, the arm cuff completely deflates and your blood pressure and pulse rate are displayed. NOTE: The monitor automatically stores blood pressure and pulse rate into the memory. 5. Press the ON/OFF button to turn the monitor off. NOTE: If you forget to turn the monitor off, it will automatically shut itself off after five minutes. 10 11 HOW TO TAKE A READING TITLE Instructions for special conditions: · If your systolic pressure is known to be more than 220 mmHg, push and hold the START button until the monitor inflates 30 to 40 mmHg higher than your suspected systolic pressure. NOTE: Do not apply more pressure than necessary. The monitor will not inflate above 300 mmHg. · If you want to stop the measurement, push the ON/OFF button. The monitor will stop inflating and start deflating rapidly, then the monitor will power off. HOW TO USE THE MEMORY FUNCTION TITLE This monitor has a memory capable of storing fourteen sets of readings. Every time you complete the measurement, the monitor automatically stores blood pressure and pulse rate. · Push the button to recall stored readings while the Heart Symbol ( ) is displayed. · When the memory is holding fourteen sets of readings, the oldest set will be deleted to store a new set. Last reading START Value before the last reading Value of fourteen readings before Continue to press button · To delete stored readings, press the button and the Start button at once, then all the readings will be deleted. NOTE: You can not delete the stored readings partially. START Press these two buttons at the same time. Display of memory deletion 12 13 HOW TO USE THE OPTIONAL AC ADAPTER (ACCESSORY ITEM SOLD SEPARATELY) TROUBLESHOOTING TITLE Error Indicator Cause Correction To avoid potential damage to the monitor, use only the exclusive AC adapter (Model HEM-ADPT1) which can be purchased from: Omron Healthcare, Inc. 300 Lakeview Parkway Vernon Hills, IL 60061 Toll Free Phone #: 1-800-634-4350 To connect AC adapter 1. Insert the AC adapter plug into the jack on the side of the monitor. 2. Insert the AC adapter plug into a 120V AC outlet (50 - 60 cycles). Cuff under-inflated. Plug Movement during measurement. Turn monitor off, wait 2-3 minutes and take another measurement. Repeat steps listed under "How to Take a Reading." If "EE" is displayed again, take another measurement by pressing and holding the START button as instruction page 12 under "How to Take a Reading", instructions for special conditions. Cuff over-inflated (more than 300 mmHg). Jack Option AC Adapter Turn the monitor off, carefully read and repeat steps listed under "How to Take a Reading." To remove the AC adapter To remove the AC adapter, disconnect the adapter plug from the AC outlet first and then disconnect the cord from the monitor's jack. NOTE: The monitor is designed not to draw power from the batteries when the AC adapter is in use. Battery voltage is excessively low. Replace all four "AA" batteries with new batteries. Problem caused by abnormal memory function. Contact OMRON Customer Service Toll Free 1-800-634-4350 If you continue to have difficulty obtaining a reading, call OMRON HEALTHCARE CUSTOMER SERVICE TOLL FREE 1-800-634-4350. Please tell the representative you have an OMRON Model HEM-711. 14 15 CAUTION TITLE CAUTION: Changes or modifications not expressly approved by Omron Healthcare, Inc. could void the user's warranty. NOTE: POTENTIAL FOR RADIO/TELEVISION INTERFERENCE (for U.S.A. only) This product has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. The product generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If the product does cause harmful interference to radio or television reception, which can be determined by turning the product on and off, the user is encouraged to try to correct the interference by one or more of the following measures: · Reorient or relocate the receiving antenna. · Increase the separation between the product and receiver. · Connect the product into an outlet on a circuit different from that to which the receiver is connected. · Consult the dealer or an experienced radio/TV technician for help. POTENTIAL FOR RADIO/TELEVISION INTERFERENCE (for Canada only) This digital apparatus does not exceed the Class B limits for radio noise emissions from digital apparatus as set out in the interference-causing equipment standard entitled "Digital Apparatus", ICES-003 of the Canadian Department of Communications. Cet appareil numérique respecte les limites de bruits radioeléctriques applicables aux appareils numériques de Classe B prescrites dans la norme sur le matériel brouilleur: "Appareils Numériques", ICES-003 èdictée par le ministre des communications. CARE ANDTITLE MAINTENANCE To protect your monitor from damage, please AVOID the following: · Subjecting your monitor and cuff to extreme temperatures, humidity, moisture, and direct sunlight. · Folding the cuff and tubing tightly. · Inflating the monitor over 280 mmHg. · Disassembling the monitor. · Subjecting the monitor to strong shocks (for example, dropping the monitor on the floor.) · Do not clean the monitor with volatile liquids. THE MONITOR SHOULD BE CLEANED WITH A SOFT, DRY CLOTH. · Do not clean cuff. 16 17 FIVE YEAR LIMITED WARRANTY Your HEM-711 IntelliSenseTM Automatic Blood Pressure Monitor is warranted to be free from manufacturing defects for a period of five years under normal use. The five year warranty excludes the monitor cuff. The cuff is warranted for a one year period. This warranty extends only to the original retail purchaser. Should repair be needed within the warranty period, ship the unit prepaid to Omron Healthcare, Inc., 300 Lakeview Parkway, Vernon Hills, IL 60061, Attn: Repair Dept., together with $5.00 for return shipping and insurance. Be sure to include the model number of your unit and your phone number on any correspondence. We will either repair or replace (at our option) free of charge any parts necessary to correct defects in the materials or workmanship. The above warranty is complete and exclusive. The warrantor expressly disclaims liability for incidental, special, or consequential damages of any nature. (Some states do not allow the exclusion or limitation of incidental or consequential damages, so the above warranty may not apply to you.) Any implied warranties arising by the operation of law shall be limited in duration to the term of this warranty. (Some states do not allow limitations on how long an implied warranty lasts, so the above limitation may not apply to you.) This warranty gives you specific legal rights, and you may have other rights which vary from state to state. As a condition to operation of your warranty, the enclosed registration card must be completed and sent to us within 10 days from the date of purchase. FOR CUSTOMER SERVICE CALL TOLL FREE: 1-800-634-4350 Model: Display: Measurement Range: Accuracy/Calibration: Inflation: Deflation: SPECIFICATIONS HEM-711 LCD Digital Display Pressure: 0 to 280 mmHg Pulse: 40 to 180/minute Pressure: ±3 mmHg or 2% of reading Pulse: ±5% of reading Automatic by electric pump Active electronic control valve Active electronic control valve Capacitive pressure sensor Oscillometric method Capacitive pressure sensor 4 "AA" batteries or AC adapter (sold separately) Approximately 300 uses 30 to 85% RH maximum Storage Temperature/Humidity: Main Unit Weight: Main Unit Dimensions: Cuff Dimensions: Cuff Circumference: Accessories: ­4°F to 140°F (­20°C to 60°C) 10 to 95% RH maximum Approximately 12.3 oz (350g) not including batteries Approximately 4 1/4" (l) x 6 2/3" (w) x 2 3/5" (h) (109 mm x 170 mm x 66 mm) Approximately 5 1/2" x 19" (140 mm x 480 mm) Fits arm circumference 9" to 13" Arm cuff, carrying case, instruction manual Rapid Pressure Release: Pressure Detection: Measurement Method: Pulse Wave Detection: Power Source: Battery Life: Operating Temperature/Humidity: 50°F to 104°F (10°C to 40°C) NOTE: These specifications are subject to change without notice. *Optional accessories: large cuff (fits arms 13" to 17" in circumference) and small cuff (fits arms 7" to 9" in circumference) are sold separately. 18 19


OMRON HEM-711, , Sport.

Detailed instructions for use are in the User's Guide.

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Diplodocs provides you a fast and easy access to the user manual OMRON HEM-711.

OMRON offer a product for which we do not have the user manual? Let us know what you are looking for: user manual, user guide, instructions, owner's manual, online manual, user's manual, users manual, users guide, owner manual, owners manual, user's guide, handbook, instructions for use, instruction manual, operation manual, operating instructions, installation guide, quick start guide, quikstart guide, getting started, installation instructions, installation guide,mounting instruction, assembly instrucions, fixing instructions, use instruction, schematics, operating manual, feature sheet, data sheet, booklet, service manual, use and care guide, installation manual, installation software, RTFM.

Diplodocs allows you to download user manual OMRON HEM-711, user guide OMRON HEM-711, instructions OMRON HEM-711, owner's manual OMRON HEM-711, online manual OMRON HEM-711.


Access web reviews
Copyright © 2005 - 2008 - Diplodocs - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.