Download user guide, user manual, owner manual and instructions guide
5 600 brands
1 870 000 user's guides
Search a brand
Advanced Search



Our partners wish to propose you the following products


Visit OREGON SCIENTIFIC official site

User manual OREGON SCIENTIFIC BWR102

Diplodocs help download the user guide OREGON SCIENTIFIC BWR102.



Download the user manual OREGON SCIENTIFIC BWR102  
Download the complete
user guide (346 Ko)
Need help, support, reviews, tips or troubleshooting for your OREGON SCIENTIFIC BWR102 products ?

Preview of the first 3 pages of manual

You either have JavaScript turned off or an old version of Adobe Flash Player
Get the latest Flash Player.
User guide OREGON SCIENTIFIC BWR102

Detailed instructions for use are in the User's Guide.

BMI BODY WEIGHT MONITOR MODEL : BWR102 USER'S MANUAL ADJUST THE SETTING OF THE REMOTE DISPLAY UNIT 1. enter the setting mode. set 2. set the display format. 1 2 set 3. set the hour. 1 2 set 4. set the minute. 1 2 set 5. set the year. 1 2 set 6. set the date-month format. 1 2 set 7. set the month. 1 2 set 8. set the date. 1 2 set 1 GB GB 9. set the format of the measurement unit. 1 2 set ACQUIRE WEIGHT FROM SCALE 1. select the display unit on scale. RESET lb kg st - lb 2. step on the scale. 3. stand still till reading come out. Note: Beep sound to indicate end of measurement. 10 4. step off the scale. Note: Repeat step 2 - 3 for next measurement. 5 2 STORE WEIGHT TO REMOTE DISPLAY UNIT 1. take measurement from scale. 2. activate receiving mode. Note: Beep sound to indicate the activation of receiving mode. Receiving function will be activated for 30 sec. 1 30 3. weight received from scale. Note: Beep sound to indicate signal is being received from the scale. 2 If the height is not set, there will not have BMI displayed. 4. select the user. 1 2 1 5. store the weight. Note: Beep sound to indicate the weight is stored to memory. No memory for guest mode. 1 7 2 3 GB GB USER SETTING / MEMORY RECALL FROM THE REMOTE DISPLAY UNIT 1a. select the user. 1 2 1 Note: If the height is not set, there will not have height displayed. 1b. quit user mode. 1 2a. recall memory. 1 2 3 mem mem 2 2b. set the heigt. 1 2 3 set set 4 TIPS A. install the batteries to the unit. B. when battery is first installed on both scale and remote display unit. B-1. acquire weight on scale. B-2. match the remote display unit with the scale. Note: a) beep sound to indicate the matching is activated. b) check the reading on scale and remote display unit . c) if fail, repeat step B-1 & B-2. B-3. set the clock. C. after changing batteries of the scale, repeat step B-1 & B-2. D. after changing batteries of the remote display unit, set the clock only. E. replace all batteries when appears on the scale. F. replace battery when for scale or for remote display unit appears on remote display unit. G. memory stored in remote display unit will not be ereased after changing batteries. H. if there exist irregularity in weighing, press reset on the scale and then repeat step B-1 & B-2. Note: a) place a blunt stylus into the slot to press be reset. b) after reset please wait for few seconds for the scale to self-calibrate. I. allow the scale to settle for around 30 min if there is a sudden change in embient environment . eg. from an air conditioned room to an open area. If not disposed of properly, batteries can be harmful. Protect the environment by taking exhausted batteries to authorized disposal stations. To extend battery life, when battery power is low, replace all the batteries. 5 GB GB WHAT IS BODY MASS INDEX (BMI) ? Body Mass index (BMI) is a measurement of your body height to weight ratio. BMI is the most widely used an international standard for evaluating obesity. It is expressed as your body weight in kilograms divided by the square of your body height in meters. BMI = body weight (kg) [body height (m)]2 It can be used as indication to estimate whether you are overweight or underweight. According to various statistics when BMI closes to 22, the mortality rate is the minimal thus the health condition is most ideal. The following can be used as a guidance reference for the interpretation of BMI reading. BMI is low : You have low amount of body fat. It will be desirable if you are an athlete. If your body weight and BMI is low and you are not an athlete, it is suggested you to gain weight through a balance diet and exercise to improve your own immunity. BMI is average : This shows an ideal BMI - your amount of body fat is at healthy level. It shows the lowest incidence for you to have serious illness. BMI is high : This is the board line. Your risk to get illness increases. It is better to lower your body weight through diet and exercise. BMI is very high : This is an unhealthy situation. You are excessive prosperity. You are at high risk to get heart disease, high blood pressure and other series illness. It is strongly recommended you to lose weight by changing the diet and execise more. Mortality Rate BMI value 22 Asian Level BMI Low 19.7 or less Average 19.8~24.1 High 24.2~26.3 Very High 26.4 or more Non-Asian Level BMI Low 19.9 or less Average 20.0~24.9 High 25.0~26.9 Very High 30.0 or more Important : Please consult your doctor for the diet program. 6 TROUBLE SHOOTING Symptom 1. Description incorrect use or weight measured is not stable. Action step off the scale first and repeat the measurement. 2. scale overloaded. be sure no excessive mass is put on scale and then repeat the measurement. 3. no data of height is input for BMI or BMI is out of range. check the height and repeat the measurement NOTES FOR THE USER MAX 150kg A. maximum capacity: 150 kg / 330 lb / 23st8lb 100g B. graduation: 0.1 kg / 0.2 lb C. height input range : 94.0 - 240.0 cm / 3'1.0" - 7'10.5" D. BMI measurement range : 5 - 50 kg / m2 BMI E. use additional foot pad for use on carpet F. power: scale - 4 x LR6 / AA / UM-3 1.5V batteries; remote display unit - 4 x LR6 / AA / UM-3 1.5V batteries G. avoid soft and unlevelled grounding H. do not store the scale erect 7 GB GB I. do not load the scale when not in use J. avoid from wet RR CL EA NE K. avoid from abrasive or corrosive cleaning agent EC-DECLARATION OF CONFORMITY This product contains the approved transmitter module TX 01 and complies with the essential requirements of Article 3 of the R&TTE 1999/5/EC Directives, if used for its intended use and that the following standard(s) has/have been applied: Efficient use of radio frequency spectrum (Article 3.2 of the R&TTE Directive) applied standard(s) Electromagnetic compatibility (Article 3.1.b of the R&TTE Directive) applied standard(s) ETS 300 683:1997 EN 300 220-1(2,3):1997 Safety of information technology equipment (Article 3.1.a of the R&TTE directive) applied standard(s) EN 60950:1997 Additional information: The product therefore conforms with the Low Voltage Directive 73/23/EC, the EMC Directive 89/336/EC and R&TTE Directive 1999/5/EC (appendix II) and carries the respective CE marking. VS-Villingen / Germany Gerhard Preis August 2001 EC representative of manufacturer RTTE Compliant Countries : All EU countries, Switzerland CH And Norway N 8 GB Legend: Key```` key - Press - Press and hold - Flashing F Légende: Key key - Key Appuyer - Key Appuyer et maintenir appuyer - Clignotant D Legende: Key key - Betätigen - Gedrückt halten - Blinkt I Legenda: Key key - Premere il tasto - Premere il tasto e tenerlo premuto - Flashing lampeggiante ES Leyenda: Key key - Pulsar - Pulsar y mantener oprimido - Parpadeando P Legenda: Key key - Pressione - Pressione e segure - Intermitente 9 GB GB NOTE FOR THE USER · · Please read the manual carefully before use. The scale will calibrate automatically to provide accurate measurement when the scale is placed on the ground. Message: , will be displayed on the scale to indicate the calibration is in process. Normally it will take 2-3 seconds only. Please leave the scale alone when you see such message. 10 11 GB

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Diplodocs provides you a fast and easy access to the user manual OREGON SCIENTIFIC BWR102.

OREGON SCIENTIFIC offer a product for which we do not have the user manual? Let us know what you are looking for: user guide, owner's manual, online manual, operating instructions, quick start guide, mounting instructions, schematics, service manual, installation instructions, RTFM.

Diplodocs allows you to download user manual OREGON SCIENTIFIC BWR102, user guide OREGON SCIENTIFIC BWR102, instructions OREGON SCIENTIFIC BWR102, owner's manual OREGON SCIENTIFIC BWR102, online manual OREGON SCIENTIFIC BWR102.


OREGON SCIENTIFIC BWR102, HUGER, OREGON, OREGON SCIENTIFIQUE, Watch & Clock.
Include the add-on to download manuals from your site, forum or blog Frequently Asked Questions Contact Diplodocs team Last searches
Last additions
Sitemap
Brands starting with A B C D E F G H I J K L M N O P Q R S T U V W X Y Z #
Copyright © 2005 - 2008 - Diplodocs - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.