Detailed instructions for use are in the User's Guide. Wireless Thermo Clock Model : RMR602A
User Manual
RMR602A lab test cover R1
1
1/8/04, 6:51 PM
CONTENTS
Contents ................................................................... 1 Introduction .............................................................. 2 About Oregon Scientific .......................................... 2 Product Overview .................................................... 3 Front View .............................................................. 3 Back View .............................................................. 4 Remote Sensor ...................................................... 5 Getting Started ......................................................... 6 Batteries ................................................................. 6 Change Settings .................................................... 6 Table Stand or Wall Mount ..................................... 6 Remote Sensor ......................................................... 6 Setup Sensor ......................................................... 7 Data Transmission ................................................. 8 Search for Sensor .................................................. 8 Clock ......................................................................... 8 Turn Atomic Clock ON/OFF ................................... 9 Set Clock ............................................................... 9 Switch Clock Display ............................................. 9 Alarm ......................................................................... 9 View Alarm Settings ............................................... 9 Set Alarm ............................................................... 9 Activate Alarm ........................................................ 9 Stop Alarm ............................................................. 9 1
RMR602A lab test R2 1
Temperature ............................................................ 10 Select Temperature Unit ...................................... 10 Minimum / Maximum Records ............................. 10 Reset System ......................................................... 10 Safety and Care ...................................................... 10 Warnings ................................................................. 11 Troubleshooting ..................................................... 11 Specifications ......................................................... 12 Main Unit Dimensions .......................................... 12 Remote Sensor Dimensions ................................ 12 Temperature ......................................................... 12 Remote Sensor .................................................... 12 Clock .................................................................... 12 Power ................................................................... 12 FCC Statement ....................................................... 13
1/17/04, 4:49 PM
EN
EN
INTRODUCTION
Thank you for selecting the Oregon ScientificTM Wireless Thermo Clock (RMR602A). This device bundles precise time keeping, alarm, and temperature monitoring features into a single tool you can use from the convenience of your home. In this box, you will find: · Main unit · Remote sensor Keep this manual handy as you use your new product. It contains practical step-by-step instructions, as well as technical specifications and warnings you should know.
ABOUT OREGON SCIENTIFIC
Visit our website (www.oregonscientific.com) to learn more about other Oregon Scientific products such as digital cameras, hand-held organizers, health and fitness gear, and projection clocks. The website also includes contact information for our customer service department, in case you need to reach us.
2
RMR602A lab test R2 2 1/17/04, 4:49 PM
PRODUCT OVERVIEW
FRONT VIEW 1 1. 4 5 2
MODE
Outdoor Temperature Area: Readings, sensor battery and reception status Indoor Temperature Area: Readings and main unit battery status. Clock / Alarm Area: Time, day of week, month, date, alarm : Press to increase setting or enable Atomic Clock signal reception / alarm : Press to decrease setting or disable Atomic Clock signal reception / alarm MODE: Press to change display / settings MEM: Press to view current or saved max / min temperature readings ((.)): Press to view alarm settings
2. 3. 4. 5. 6
6 7
MEM
3 8
7. 8.
3
RMR602A lab test R2 3 1/17/04, 4:49 PM
EN
EN
BACK VIEW BACK VIEW
1. 1
MODEL NO. RMR602A
Wall mount Battery compartment °C / °F switch RESET hole SEARCH button Table stand
2. 3. 4. 5.
"AAA" UM4 1.5V
2
"AAA" UM4 1.5V
6.
3 4
C/ F SEARCH RESET
REMOTE SENSOR (THGR122N)
GETTING STARTED
5 6
4
RMR602A lab test R2 4 1/17/04, 4:49 PM
REMOTE SENSOR
1 1
2, 3
1.
LED Status indicator
1. 2. 3.
Wall mount hole Battery compartment Battery compartment cover
5
RMR602A lab test R2 5 1/17/04, 4:49 PM
EN
EN
GETTING STARTED
BATTERIES Batteries are not supplied with this product. You will need to purchase 2 x UM-4 (AAA) 1.5V alkaline batteries for the main unit, and 2 x UM-3 (AA) 1.5V alkaline batteries for the remote sensor. Insert batteries before first use, matching the polarity as shown in the battery compartment. For best results, install batteries in the remote sensor before the main unit. Press RESET after each battery change. NOTE Do not use rechargeable batteries. shows when batteries are low. UNIT Main Remote LOCATION Indoor Temperature Area Outdoor Temperature Area.
CHANGE SETTINGS 1. 2. 3. Press and hold MODE for 2 seconds to enter setting mode. Press UP or DOWN to change settings. Press MODE to confirm.
TABLE STAND OR WALL MOUNT Use the stand on the back of the product, or mount it on a wall with a nail.
REMOTE SENSOR
This product is shipped with a remote sensor that collects temperature readings. Only one sensor can be used with this product.
6
RMR602A lab test R2 6 1/17/04, 4:49 PM
SETUP SENSOR 1. 2. 3. Open the remote sensor battery compartment with a small Phillips screwdriver. Insert the batteries, matching the polarity as shown in the battery compartment. Place the sensor near the main unit. Press RESET, then SEARCH, on the main unit to initiate signal sending between the sensor and the main unit. The reception icon on the main unit will blink for approximately 3 minutes while it is searching for the sensor. (Refer to the Sensor Data Transmission section for more information.) Close the remote sensor battery compartment. Secure the sensor in the desired location using the wall mount or table stand.
For best results: · Insert the batteries before you mount the sensor. · Place the sensor out of direct sunlight and moisture. · Do not place the sensor more than 30 meters (98 feet) from the main (indoor) unit. · Position the sensor so that it faces the main (indoor) unit, minimizing obstructions such as doors, walls, and furniture. · Place the sensor in a location with a clear view to the sky, away from metallic or electronic objects. · Position the sensor close to the main unit during cold winter months as below-freezing temperatures may affect battery performance and signal transmission. You may need to experiment with various locations to get the best results.
4. 5.
7
RMR602A lab test R2 7 1/17/04, 4:49 PM
EN
EN
DATA TRANSMISSION Data is sent from the sensor(s) every 78 seconds. The reception icon shown in the Outdoor Temperature Area shows the status. ICON DESCRIPTION Main unit is searching for sensor. Sensor signal is steady. The sensor cannot be found. Search for the sensor or check batteries.
CLOCK
This product has two displays: Clock with day of week in German, English, French, Italian, or Spanish, and Calendar display with month and date. The time is automatically updated by the US Atomic Clock in Boulder, Colorado unless you disable this feature. Signals are collected by the main unit when it is within 1500 km (932 miles) of a signal. Initial reception takes 2 - 10 minutes, and is initiated when you first setup the unit, and whenever you press RESET. Once complete, the reception icon will stop blinking. The icon is shown in the Clock Area.
--- shows
SEARCH FOR SENSOR To search for the sensor, press SEARCH . The SEARCH button is located in the main unit battery compartment. NOTE If the sensor is still not found, check the batteries, obstructions, and remote unit location. NOTE Signals from household devices such as doorbells, electronic garage doors, and home security systems may cause temporary reception failure. This is normal and does not affect general product performance. The reception will resume once the interference ends. To force a manual search for Atomic Clock signals, press and hold UP for 2 seconds. If no signal is found, check the batteries. NOTE If the Atomic Clock signal is received and the hour is incorrect, use the "hour offset" feature to adjust it to to the right value. Please see "SET CLOCK" on pg. 9 for instructions. 8
RMR602A lab test R2 8 1/17/04, 4:49 PM
TURN ATOMIC CLOCK ON/OFF Perform this step if you cannot receive Atomic Clock signals. Press and hold DOWN for 2 seconds. Then, manually set the clock following the "Set Clock" instructions (below). The signal icon indicates that the Atomic Clock feature is ON. No icon means that it is OFF.
ALARM
This product has 2 alarms: a Single Alarm and a Weekday Alarm. The Single Alarm can be set to go off at a specific time for a one-time event (for example, if you are napping on Saturday). The Weekday Alarm will sound at the same time Monday - Friday (but not on weekends). VIEW ALARM SETTINGS
SET CLOCK You only need to do this if you have disabled the Atomic Clock feature (for example, if you are too far from or cannot receive a signal). 1. 2. Press and hold MODE for 2 seconds. The Clock Area will blink. Select the hour offset (-9 to +9), hour display format (12 or 24 hour), hour, minute, year, month, day, and language. Press UP or DOWN to change the setting. Press MODE to confirm. NOTE The language options are (D) German, (E) English, (F) French, (I) Italian, and (S) Spanish. SWITCH CLOCK DISPLAY Press MODE to toggle between Calendar and Clock display with Hour Offset, Seconds, or Weekday. 9
RMR602A lab test R2 9
Press ((.)) to display the Alarm settings you wish to view: Weekday or Single. SET ALARM 1. 2. 3. Press ((.)) to display the type of Alarm you wish to set: Weekday or Single. Press and hold ((.)) again for 2 seconds. The Alarm settings will blink. Select the hour and minute. Press UP or DOWN to change settings. Press ((.)) to confirm.
ACTIVATE ALARM Press or to activate or deactivate the Alarm. --indicates that the alarm is deactivated. STOP ALARM To stop the alarm from ringing, press ((.)).
1/17/04, 4:49 PM
EN
EN
TEMPERATURE
This product can display current, maximum, and minimum temperature readings collected by the main unit (indoor) and remote sensor (outdoor). Outdoor temperature data collected by the remote sensor is updated every 78 seconds. SELECT TEMPERATURE UNIT Press the °C / °F button to switch between temperature units. The button is located in the battery compartment. MINIMUM / MAXIMUM RECORDS Press MEM to toggle between current, maximum (MAX) and minimum (MIN) records. To clear the records, press and hold MEM for 2 seconds. The current temperature readings will be shown as the minimum and maximum records.
RESET SYSTEM
The RESET button is located in the battery compartments for the main unit. Press RESET when you change the batteries and whenever performance is not behaving as expected (for example, unable to establish radio frequency link with remote sensor or radio-controlled clock). NOTE When you press RESET, all settings will return to default value, and you will lose all stored information.
SAFETY AND CARE
Clean the product with a slightly damp cloth and alcohol - free mild detergent. Avoid dropping the product or placing it in a high-traffic location.
10
RMR602A lab test R2 10 1/17/04, 4:49 PM
WARNINGS
This product is designed to give you years of service if handled properly. Observe the following guidelines: · Never immerse the product in water. This can cause electrical shock and damage the product. · Do not subject the main unit to extreme force, shock, or fluctuations in temperature or humidity. · Do not tamper with the internal components. · Do not mix new and old batteries or batteries of different types. · Do not use rechargeable batteries with this product. · Remove the batteries if storing this product for a long period of time. · Do not scratch the LCD display. Do not make any changes or modifications to this product. Unauthorized changes may void your right to use the product. The technical specification of this product and contents of this user guide are subject to change without notice. Images not drawn to scale.
TROUBLESHOOTING
Check here before contacting our customer service department. Problem Calendar Clock Symptom Remedy
Strange date / Change language ( 9) month Cannot adjust Disable Atomic Clock clock ( 9) Cannot autosynch 1. Adjust batteries. ( 6) 2. Press RESET ( 10) 3. Manually activate Atomic Clock feature ( 9)
Temp Remote sensor
Shows "LLL" or "HHH"
Temperature is out-ofrange
Cannot locate Check batteries ( 6) remote Check location ( 7) sensor Data does not match main unit Initiate a manual sensor search ( 8)
11
RMR602A lab test R2 11 1/17/04, 4:49 PM
EN
EN
SPECIFICATIONS
MAIN UNIT DIMENSIONS LxWxH Weight 100 x 47 x 99 mm (3.94 x 1.85 x 3.90 inches) 4.80 ounces with battery
REMOTE SENSOR RF frequency Range Transmission CLOCK
433 MHz 30 meters (98 feet) with no obstructions every 78 seconds
REMOTE SENSOR DIMENSIONS LxWxH Weight 96 x 50 x 28 mm (3.8 x 2.0 x 1.1 inches) 1.62 ounce without battery
Atomic Clock Clock display Hour format Hour offset Calendar
Auto or manual (disabled) HH:MM:SS 12hr AM/PM or 24hr +/- 9 hours MM/DD; weekday in 5 languages (D, E, F, I, S) Weekday and Single; 2- minute crescendo
TEMPERATURE Unit Indoor Range Outdoor Range Resolution Memory
°C or °F -5 °C to 50 °C (23 °F to 122 °F) -20 °C to 60 °C (-4 °F to 140 °F) 0.1 °C (0.2° F) Min / Max
Alarm
POWER Main unit batteries Sensor batteries 2 x UM-4 (AAA) 1.5V alkaline 2 x UM-3 (AA) 1.5V alkaline
12
RMR602A lab test R2 12 1/17/04, 4:49 PM
FCC STATEMENT
This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) This device must accept any interference received, including interference that may cause undesired operation. Warning: Changes or modifications to this unit not expressly approved by the party responsible for compliance could void the user's authority to operate the equipment. NOTE: This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:
· Reorient or relocate the receiving antenna. · Increase the separation between the equipment and receiver. · Connect the equipment into an outlet on a circuit different from that to which the receiver is connected. · Consult the dealer or an experienced radio/TV technician for help.
13
RMR602A lab test R2 13 1/17/04, 4:49 PM
EN
EN
DECLARATION OF CONFORMITY The information below is not to be used as contact for support or sales. Please call our customer service number (listed on our website at www.oregonscientific.com, or on the warranty card for this product) for all inquiries instead. We Name: Address: Telephone No.: Fax No.: declare that the product Product No.: Product Name: Manufacturer: Address: Oregon Scientific, Inc. 19861 SW 95th Place, Tualatin, Oregon 97062 USA 1-800-853-8883 1-503-684-8883
is in conformity with Part 15 of the FCC Rules. Operation is subject to the following two conditions: 1) This device may not cause harmful interference. 2) This device must accept any interference received, including interference that may cause undesired operation.
RMR602A Wireless Thermo Clock IDT Technology Limited Block C, 9/F, Kaiser Estate, Phase 1, 41 Man Yue St., Hung Hom, Kowloon, Hong Kong
14
RMR602A lab test R2 14 1/17/04, 4:49 PM
© 2004 Oregon Scientific. All rights reserved. P/N.: 086-003350-010
RMR602A lab test back cover Black
1
12/29/03, 10:23 PM
If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Diplodocs provides you a fast and easy access to the user manual OREGON SCIENTIFIC RMR602A. OREGON SCIENTIFIC offer a product for which we do not have the user manual? Let us know what you are looking for: user guide, owner's manual, online manual, operating instructions, quick start guide, mounting instructions, schematics, service manual, installation instructions, RTFM. Diplodocs allows you to download user manual OREGON SCIENTIFIC RMR602A, user guide OREGON SCIENTIFIC RMR602A, instructions OREGON SCIENTIFIC RMR602A, owner's manual OREGON SCIENTIFIC RMR602A, online manual OREGON SCIENTIFIC RMR602A.Access web reviews OREGON SCIENTIFIC RMR602A, HUGER, OREGON, OREGON SCIENTIFIQUE, Watch & Clock. |
![]() |
Include the add-on to download manuals from your site, forum or blog | ![]() |
Frequently Asked Questions | ![]() |
Contact Diplodocs team | ![]() |
Last searches Last additions |
![]() |
Sitemap | ![]() |
|||
| Brands starting with A B C D E F G H I J K L M N O P Q R S T U V W X Y Z # | |||||||||||||
|
|
Copyright © 2005 - 2008 - Diplodocs -
All Rights Reserved. Designated trademarks and brands are the property of their respective owners. |