User guide POWERDSINE POWERVIEW PRO
Detailed instructions for use are in the User's Guide. Power over Ethernet Power View Pro
User Guide
Remote Web Managers
Notice
The information contained herein is believed to be accurate and reliable at the time of printing. However, due to ongoing product improvements and revisions, PowerDsine cannot accept responsibility for inadvertent errors, inaccuracies, subsequent changes or omissions of printed material. PowerDsine Ltd. reserves the right to make changes to products and to their specifications as described in this document, at any time, without prior notice. No rights to any PowerDsine Ltd. Intellectual property are licensed to any third party, either directly, by implication or by any other method.
© 2006 PowerDsine Ltd.
All rights reserved. This document is subject to change without notice.
Acknowledgements
All other products or trademarks are property of their respective owners. The product described by this manual is a licensed product of PowerDsine.
Abbreviations and Terminology
Abbreviations are spelled out in full when first used. Only industrystandard terms are used throughout this manual. Note: Covered under U.S patent S/N 6,473,608. Other Patents pending
PowerDsine
2
Power over Ethernet Solutions
Remote Web Managers
Table of Contents
1 A b o ut t h is Gu id e .............................................................................. 6 1.1 Objectives .....................................................................................6 1.2 Audience.......................................................................................6 1.3 Organization .................................................................................7 1.4 Conventions..................................................................................8 1.5 Related Documentation ................................................................8 1.6 Abbreviations ................................................................................8 2 Intro ducing the Po wer V iew Pro ....................................................... 9 2.1 Overview.......................................................................................9 2.2 Features........................................................................................9 2.3 System Capabilities ................................................................... 10 2.3.1 Configuration options..................................................................10 2.4 Security & User Authentication.................................................. 11 2.4.1 Web Configuration......................................................................11 2.4.2 SNMP .........................................................................................11 2.4.3 Telnet Configuration ...................................................................12 3.1 Installation.................................................................................. 13 3.1.1 Configuration Options.................................................................13 3.2 System Requirements ............................................................... 14 3.3 Hardware Setup......................................................................... 15 3.4 Installation Procedure ................................................................ 16 3.4.1 Web Browsing ............................................................................16 3.4.2 Telnet Browsing..........................................................................16 3.4.3 RS232 Configuration using Hyper Terminal Application ............16 3.4.4 Configuring the System via the HyperTerminal..........................19 3.4.5 Using the View Menu..................................................................20 3.4.6 Using the Configuration & Maintenance Menu...........................20 3.4.7 Using the Ping Remote Host Menu ............................................22 3.5 TFTP Server Configuration........................................................ 23 4 GU I D escriptio n ............................................................................. 24 4.1 Overview.................................................................................... 24 4.2 Opening Screen......................................................................... 24 4.3 View Screen............................................................................... 25 4.3.1 View Status Screen ....................................................................26 4.3.2 View Network & Security Configuration Screen ......................33 4.3.3 View - Product Information .........................................................38 4.4 System Configuration Screen.................................................... 39 4.4.1 System Configuration Network Screen ......................................39
PowerDsine
3
Power over Ethernet Solutions
Remote Web Managers 4.4.2 System Configuration SNMP......................................................43 4.4.3 System Configuration SNMPv3..................................................47 4.4.4 System Configuration Security ...................................................50 4.4.5 System Configuration Product Parameters................................53 4.4.6 System Configuration Maintenance ...........................................55 4.5 Port Configuration Screen ......................................................... 57 4.5.1 Port Configuration Enable/Disable .............................................58 4.5.2 Port Configuration Detailed ........................................................60 5 S N M P M on it o rin g a nd Con f ig u ra t ion GU I ..................................... 6 3 5.1 General ...................................................................................... 63 5.2 SNMP MIB's............................................................................... 63 5.3 RFC3621 PoE MIB .................................................................... 64 5.4 Private MIB ................................................................................ 65 6 Operation ...................................................................................... 66 6.1 General ...................................................................................... 66 6.2 Logging in .................................................................................. 67 6.3 Viewing System Status .............................................................. 68 6.4 Viewing Network & Security Configuration Status..................... 69 6.5 Viewing Product Information...................................................... 70 6.6 Configuring System - Network................................................... 70 6.7 Configuring System SNMP........................................................ 73 6.8 Configuring System SNMPv3 .................................................... 74 6.9 Configuring System Security ..................................................... 75 6.9.1 Protecting View by Password.....................................................77 6.9.2 Modifying Remote Access..........................................................77 6.10 Configuring Product Parameters ............................................... 80 6.11 Configuring System Maintenance.............................................. 81 6.12 Configuring the Ports ................................................................. 82 6.13 Configuring Additional Port Settings.......................................... 84 6.13.1 Specific Ports Settings................................................................85 6.13.2 All Ports Settings ........................................................................85 7 Tro ublesho o ting ............................................................................. 86 7.1 General ...................................................................................... 86 8 S o f t wa re U pd a t e ............................................................................ 9 0 8.1 Architecture................................................................................ 90 8.2 Software Upgrade...................................................................... 91 8.2.1 General.......................................................................................91 8.2.2 Upgrade Process........................................................................92 8.2.3 Software update from version 1.xx to 2.xx .................................94
PowerDsine
4
Power over Ethernet Solutions
Remote Web Managers List of Figures Figure 2-1: Management Deployment............................................................. 10 Figure 2-2: Connecting the PoE Unit............................................................... 15 Figure 4-1: Opening Screen ............................................................................ 25 Figure 4-2: View Menu .................................................................................... 25 Figure 4-3: View Status Screen....................................................................... 26 Figure 4-4: Ports Status Panel ........................................................................ 27 Figure 4-5: View - Product Information Screen ............................................... 38 Figure 4-6: System Configuration Screen ....................................................... 39 Figure 4-7: System Configuration Network Screen ......................................... 40 Figure 4-8: System Configuration SNMPv3 Screen ........................................ 47 Figure 4-9: System Configuration Security Screen ......................................... 50 Figure 4-10: System Configuration Product Parameters Screen .................... 53 Figure 4-11: System Configuration Maintenance Screen ............................... 55 Figure 4-12: Port Configuration Screen........................................................... 57 Figure 4-13: Port Configuration Enable/Disable Screen ................................. 58 Figure 4-14: Port Configuration Detailed Screen (60xxG, 65xx family) .......... 60 Figure 4-15: Port Configuration Detailed Screen (80xx Midspan family) ........ 61 Figure 5-1: MIB Tree Structure........................................................................ 64 Figure 5-2: MIB's Management Funtionalities................................................. 65 Figure 6-1: Network Management Tool........................................................... 66 Figure 8-1: System Software Architecture....................................................... 90
List of Tables
Table 1-1: Conventions Used .......................................................................... 8 Table 4-1: Main Status Indications .................................................................. 27 Table 4-2: 60xxG Gigabit Midspan Port Status Indications............................. 28 Table 7-1: Troubleshooting Steps ................................................................... 86
PowerDsine
5
Power over Ethernet Solutions
Remote Web Managers
1
1.1 Objectives
About this Guide
This User Guide introduces PowerDsine's Power View Pro Remote Web Managers used for managing PowerDsine's Power over Ethernet (PoE) product line of Midspan devices including: PD 6506/AC/M 6 ports 10/100Mbit Midspan PD 6512/AC/M 12 ports 10/100Mbit Midspan PD 6524/AC/M 24 ports 10/100Mbit Midspan PD 6524/AC/M/F 24 ports 10/100Mbit full power Midspan PD 6548/AC/M 48 ports 10/100Mbit Midspan PD 8006/AC/M 6 ports 10/100Mbit High Power Midspan PD 8012/AC/M 12 ports 10/100Mbit High Power Midspan PD - 6006G/AC/M 6 ports 1Gigabit Midspan PD - 6012G/AC/M 12 ports 1Gigabit Midspan PD - 6024G/AC/M 24 ports 1Gigabit Midspan
1.2
Audience
This Guide is intended for network administrators, supervisors and installation technicians who have a background in: Basic concepts and terminology of networking Network topology Protocols Microsoft Windows environment
PowerDsine
6
Power over Ethernet Solutions
Remote Web Managers
1.3
Organization
This Guide is divided into several Sections, as follows: Section 1 - Defines the overall concepts used in this Guide, conventions used and associated documentation. Section 2 - Describes the Power View Pro features and capabilities. Section 3 Provides a complete system installation procedure. Section 4 - Provides the GUI detailed description. Section 5 - Explains how to use the PowerView Pro GUI. Section 6 Provides a troubleshooting guide Section 7 Explains the process for upgrading Midspan software.
PowerDsine
7
Power over Ethernet Solutions
Remote Web Managers
1.4
Conventions
The various conventions used in defining commands and examples are given in Table 1-1. Table 1-1: Conventions Used
CONVENTION bold italics screen Bold screen Notes DEFINITION Keywords & commands Represents a GUI item Displayed Information Information to be entered Helpful information
1.5
Related Documentation
For additional information, refer to the following documentation: Power over Ethernet PowerDsine PD-60XX (AC and DC version), User Manual (06-6800-056). IEEE Standard 802.3af, DTE Power via MDI.
1.6
Abbreviations
PoE NTP DES MD5 MDI MIB PD SNMP SSL FTP TFTP Power over Ethernet Network Time Protocol Data Encryption Standard Message Digest 5 Multiple-Document Interface Management Information Base Powered Device Simple Network Management Protocol Secure Sockets Layer File Transfer Protocol Trivial File Transfer Protocol
PowerDsine
8
Power over Ethernet Solutions
Remote Web Managers
2 Intr o duc ing the Po w er Vie w Pro
2.1 Overview
PowerDsine's Power View Pro is a management system, utilized for complete monitoring and control of PowerDsine's Power over Ethernet (PoE) Midspans, via a remote network management station. The system provides direct on-line power supervision, configuration, monitoring and diagnostics of PowerDsine products via their SNMP managers.
NOTE: The principle of operation is similar for all Midspan models described in this manual
2.2
Features
The manager provides a number of unique features for PoE Midspan management as follows: HTTP - Web based for remote management of Power over Ethernet device SSL - Secured WEB based configuration Configuration using graphical representations of remote device SNMPv2c/v1/v3 RFC3621 Power over Ethernet (PoE) SNMP MIBs Private MIB extension to RFC3621 PoE MIB Telnet Remote terminal over Ethernet Network Real time monitoring with visual status System status display SysLog Server - Log events to remote SysLog Server
PowerDsine
9
Power over Ethernet Solutions
Remote Web Managers
2.3
System Capabilities
The manager can be accessed from any computer by WEB browser such as an Internt Explorer/Netscape, SNMP management station, Telnet, or RS232 Terminal. The Power View Pro allows monitoring and controlling of over Etehrnet IP networks as shown in Figure 2-1:
Figure 2-1: Management Deployment
2.3.1
Configuration options
· Web based by utilizing a WEB browser · SNMPv1/2c/3 by utilizing an SNMP management application on a remote computer · Telnet via the RJ45 Etehrnet port by using Telent application on a remote computer · Serial communication port by using Terminal emulation software such as Microsoft Windows Hyper Terminal, or any similar software. · Serial communication rate must be set to 38400, no hardware flow control and cross cable should be used (pin2 crossed with pin3).
PowerDsine
10
Power over Ethernet Solutions
Remote Web Managers
NOTE: The unit is shipped with default IP of 192.168.0.50. Make sure that a computer Network card is configured to the same IP network.
· Telnet and WEB configuration are password protected. · Serial communication configuration should be used in order to define the unit's IP address, upload / download unit configuration, restore unit configuration to factory default, or perform software updates. Any other configuration should be carried out via the WEB browser.
2.4
2.4.1
Security & User Authentication
Web Configuration
Web configuration can be protected by user by password. Two user & password protection levels are avilable as follow: · View username & password a remote user has access to Web pages that provide various information, but has no permission to perform any modifications. Configuration username & password - a remote user (usually administrator) has full authority to modify any unit's parameter.
·
2.4.2
SNMP
· · SNMP v1/v2 - community string is utilized for authentication Get/Set/Trap authentication. SNMP v3 Network Management Protocol Version-3 (SNMPv3) is an standards-based protocol, utilized for network management. It provides secure access to devices by a combination of authenticating and encrypting packets over the network.
PowerDsine
11
Power over Ethernet Solutions
Remote Web Managers
2.4.3
Telnet Configuration
Since Telnet provide access to IP configuration, software updates and data bases upload/download functions, it is always password protected (regardless of Web view & configure password selection option). WEB and Telnet utilize the same passwords (Telnet utilizes Web browser password even if the Web password function is disabled).
NOTE: The Power View Pro is provided with the following factory defaults: Protection: Configuration password protection WEB/Telnet: View (usually user) : user name ="user", password ="password" Configure (usually administrator): user name ="admin", password = "password". SNMP v3: Guest (usually remote SNMP manager) : user name ="public" View User (usually user) : user name ="view", authentication password (MD5) = "password", : privacy password (DES)= "password", Admin User (usually administrator) : user name ="admin", authentication password (MD5) = "password", : privacy password (DES)= "password",
PowerDsine
12
Power over Ethernet Solutions
Remote Web Managers
3
Installation
3.1
3.1.1
Installation
Configuration Options
The following configuration options are available: Via an RJ-45 network connector utilizing a Web browser (IP 192.168.0.50). Via an RJ-45 network connector utilizing the Telnet protocol (IP 192.168.0.50). Via an RS-232 Serial communication port (for PD-6548 please use the speacial cable which was provided with the unit), utilizing an RS-232 connector ( 38400, HW flow control off)
NOTE: This section describes the configuration procedure via the CLI commands. Configuration of system parameters Via the Web browser is further detailed in Paragraph 6.6 on page 70.
PowerDsine
13
Power over Ethernet Solutions
Remote Web Managers
3.2
System Requirements
The following hardware/software items are required in order to configure and operate the Power over Ethernet (PoE) Midspan. Computer Environment PC Ethernet Network card configured to the following parameters:
IP : 192.168.0.40, IP Mask:255.255.255.0
· ·
· · · ·
Operating system: Any Host with WEB browser Recommended OS & Web browsers: Win2000/XP running Microsoft Internet explorer Ver-6 or higher Win2000/XP running Netscape 7 or higher Access to a local network and Internet Ethernet cable. Telnet application (already provided by Windows/Linux) Serial Communication Serial ports: COM1 or COM2 are active and available Null-modem RS232 crossed cable(for PD-6548 please use the special provided cable)
Administrative Requirements · The Midspan is shipped with default IP 192.168.0.50. Before connecting the Midspan to you network, please make sure no other device is using the same IP address.
PowerDsine
14
Power over Ethernet Solutions
Remote Web Managers
3.3
Hardware Setup
Perform the following steps (see Figure 2-2): 1 2 Connect an AC power cable to the PoE unit and verify that all LEDs illuminate once (self test). For configuration through the Serial port, connect the crossed null-modem cable between the management station COM port and the PoE RS-232 port. For configuration through the Network, connect a network cable between the PoE unit front panel's RJ45 connector (use Ethernet Hub/Switch or cross cable for straight connection). Verify that the AC LED on the front panel is lit and that the Link LED is green. If any problem is encountered during setup, refer to Chapter. 7, Troubleshooting":
3
4 5
PoE Unit LAN
CROSSED NULL MODEM CABLE
To configure Network Interface parameters
Management Station
Figure 2-2: Connecting the PoE Unit
PowerDsine
15
Power over Ethernet Solutions
Remote Web Managers
3.4
3.4.1 3.4.2
Installation Procedure
Web Browsing
Open Web browser and type 192.168.0.50 in the address field.
Telnet Browsing
· · · ·
NOTE: Use Web browser to view System Configuration->Security WEB page and make sure that the Telnet checkbox is checked (selected) - see page 48.
Go to start -> Run Type the command cmd In the window type the command, telnet 192.168.0.50 Type the Username & password
3.4.3
RS232 Configuration using Hyper Terminal Application
For WIN 2000 and WIN XP users: 6 7 8 1
Go to Run (Start> Run).
Type "cmd". A DOS type window opens; click OK. Type the "ipconfig" and then click Enter. Note computer IP, mask and default gateway.
2
Click Start >Programs >Accessories >Communications > HyperTerminal; A dialog box appears.
PowerDsine
16
Power over Ethernet Solutions
Remote Web Managers
3
Enter your name or organization name in the Name text field and then click OK; Connect To window appears.
4 5
Select the desired communication port to be connected to the PoE unit and then click OK. A dialog window appears. Select the following parameters and then click OK:
Bits per second: 38400 Data bits: 8 Parity: None Stop bits: 1 Flow control: None
PowerDsine
17
Power over Ethernet Solutions
Remote Web Managers
9
The HyperTerminal screen appears;
PowerDsine
18
Power over Ethernet Solutions
Remote Web Managers
3.4.4
Configuring the System via the HyperTerminal
NOTE: There is no password protection while using the RS232 serial communication port. Password protection is only applicable for Telnet or WEB access.
Perform the following steps:
1
Click the ESC or space key: the main menu appears:
1. 2. 3.
E.
Main Menu --------------------------View Menu view unit IP, software version and release date. Configuration & Maintenance Menu - Configure unit IP, upload/download configuration & software update Ping Remote Host determine whether a particular IP system on a network is functional. Used for diagnosing IP network or router failures. Exit to debug information screen enables on going debug information to be reported by the Terminal.
PowerDsine
19
Power over Ethernet Solutions
Remote Web Managers
3.4.5
Using the View Menu
1
Select the View Menu option; View Menu appears;
View Menu ----------------------------1. View Network Parameters such as IP Address, Subnet Mask, Default Gateway and MAC Address.
NOTE: While DHCP is in use, DHCP server IP appears as well.
2. View Application & Boot Software Version allows viewing of application and boot version number and creation date. 3. View system up time displays how many days, hours, minutes & seconds the unit has been operational.
3.4.6
Using the Configuration & Maintenance Menu
1
Select the Configuration & Maintenance Menu from the Main Menu; the following menu appears;
PowerDsine
20
Power over Ethernet Solutions
Remote Web Managers
Configuration & Maintenance Menu -----------------------------------------------1. Set Static IP/DHCP allows the user to set, save & activate new network parameters. 2. Download Configuration File to Unit downloading configuration file from a remote Host named nms.db, using TFTP application (Host must run TFTP server application prior to using this option see Para. 3.5).
NOTE: Upon successful downloading, only the manager module will reset itself without effecting active powered PD devices.
3. Upload Configuration from Unit to File the unit uploads its Internal configuration file named nms_out.db to the Host, utilizing TFTP application (Host must run TFTP server application prior to using this option - see Para. 3.5). 4. Software Update Menu - allows the user to update unit software/firmware
NOTE: Host must run TFTP server application and appropriate software update package should be available to the user.
PowerDsine
21
Power over Ethernet Solutions
Remote Web Managers 5. Restore Username&Password to Factory Default restores only view/configure user name & password to default values (only
the manager module will reset itself without effecting active powered PD devices.).
6. Restore the Unit to Factory Default - restores most of the unit configuration parameters to factory default values. Please note that in order to allow the remote user to continue and configure the unit from a remote location, unit IP will remain the same (only the
manager module will reset itself without effecting active powered PD devices.).
7. Reset Manager Module Only the manager module will reset itself
without effecting active powered PD devices.
8. Reset Unit performs reset of the the entire unit, which will cause all powered PD devices to be turned off for a several seconds, and re powered. ESC - Return to Previous Menu
3.4.7
Using the Ping Remote Host Menu
The Ping Remote Host Menu is utilized to test the TCP/IP configuration by using the ping command; the user enters the remote IP address. The ping command then uses the ICMP echo request and echo reply packets to determine whether a particular IP system on a network is functional. Ping is useful for diagnosing IP network or router failures.
PowerDsine
22
Power over Ethernet Solutions
Remote Web Managers
3.5
TFTP Server Configuration
The TFTP Server allows tranfer of files stored by the Host to/from the PoE unit. This paragraph describes how to configure the TFTP server which is utilized for optional software updates. NOTES: 1. Make sure Firewall is turned off on the computer which runs the TFTP Server (or enable UDP port 69 to pass through the Firewall).
2.
For Upload Configuration make sure Enable Writes checkbox is checked when (see Para. 3.4.6)
1
Copy the NBTFTP.exe application from the provided CD to your server's desktop. Click on the
.
2
The following window appears;
Browse button
3 4
Click the Browse button and select your preferred location for the files. Click OK when done. The Server utilizes the IP address of the computer on which TFTP software is running.
PowerDsine
23
Power over Ethernet Solutions
Remote Web Managers
4
G U I De sc r ipt io n
4.1
Overview
The GUI (Graphic User Interface) provides complete monitoring, control and configuration of PowerDsine's Power over Line (PoE) products. The GUI is user friendly and presents graphical elements of the actual device in addition to information tables. The system provides several features: Graphical view of the monitored device Graphical configuration of the monitored device Properties of the management system.
The GUI provides two authorization levels as follow (see also Paragraph 4.4.4.1): User - allowed to access only to the View menus Administrator allowed to view and modify all the GUI functions
4.2
Opening Screen
The Main screen (Opening screen) window is shown in Figure 4-1. The Opening screen features three main menus as follows: View menu used to view status, network configuration and product information System Configuration menu allows system Configuration (network, SNMP, security, product parameters and maintenance (it is password protected) Port Configuration menu allows enabling/disabling of ports, allocation of power, setting of priorities and more.
PowerDsine
24
Power over Ethernet Solutions
Remote Web Managers
Figure 4-1: Opening Screen
4.3
View Screen
View menu: (see Figure 4-2): Status Network Configuration Product Information used to view the following categories
Figure 4-2: View Menu
PowerDsine
25
Power over Ethernet Solutions
Remote Web Managers
4.3.1
View Status Screen
The View Status screen is the main Midspan monitoring tool. It comprises three elements (see Figure 4-3): Ports status panel Ports power status table General power status table The Ports status panel displays the following parameters: Ports Status Link Status AC/DC Input Power Status.
Port status panel
General power status table
Ports power status table
Figure 4-3: View Status Screen
PowerDsine
26
Power over Ethernet Solutions
Remote Web Managers 4.3.1.1 Ports Status Panel The display panel includes a number of visual indicators as shown in Figure 4-4; Green illuminated port indicates that the terminal unit has been identified as "Power over Ethernet Enabled" and is active and receiving power. Disabled ports illuminate red, indicating that the port is not supplying power and is not active. An "X" symbol appears (indicates inactive port) as well.
Enabled port Disabled port
Link LED
Main LED
Figure 4-4: Ports Status Panel 4.3.1.2 Power & Communication Indications Two LED's are located on the front panel, marked "Main" and Link as described in Table 4-1 and Table 4-2. Table 4-1: Main Status Indications
Indicator Color Off AC LED Green Green blinking DC LED Green Main Power Status Internal power supply unit is unplugged or faulty Indicates AC power input active Internal power supply voltage is out of range Indicates normal 48VDC power supplied to PDs Remarks Internal power supply voltage is too low. All ports are disconnected Internal power supply voltage is within limits All ports are disconnected Applicable only for Midspan unit with 48VDC optional module
PowerDsine
27
Power over Ethernet Solutions
Remote Web Managers
Indicator Color Green blinking Orange Main Power Status External power supply DC voltage is out of range Indicates that load consumes more power than allocated Indicates valid Ethernet link, and some data communication flow over the Ethernet network Indicates valid Ethernet link(no communication data) Remarks
LINK LED (PD-6024G, PD-8012 only)
Green blinking
Green
Table 4-2: 60xxG Gigabit Midspan Port Status Indications
Port LED Color Port Load Conditions Non-active load, unplugged port, or disabled port Active load is plugged in and complies with normal load conditions Overload conditions; or short; or forced external voltage feed (constant DC) into the port Port can't be activated since total aggregated power exceeds maximum power budget Port Voltage Power to the port is disconnected. No DC voltage present on spare pairs Continuous nominal DC voltage is present on the spare pairs Power to the port is disconnected. No DC voltage is present on the spare pairs Power to the port is disconnected. No DC voltage is present on the spare pairs
Power over Ethernet Solutions
Off
Green
Orange
Orange blinking
PowerDsine
28
Remote Web Managers Table 4-3: 65xx Midspan Port Status Indications
Port LED Color Port Load Conditions Non-active load, unplugged port or disabled port Port Voltage Power to the port is disconnected. No DC voltage present on spare pairs Continuous nominal DC voltage is present on the spare pairs Power to the port is disconnected. No DC voltage is present on the spare pairs Power to the port is disconnected. No DC voltage is present on the spare pairs
Off
Green
Active load is plugged in and complies with normal load conditions Overload conditions; or short; or forced external voltage feed (constant DC) into the port Port can't be activated since total aggregated power exceeds maximum power budget
Green blinking
Slow orange blinking
PowerDsine
29
Power over Ethernet Solutions
Remote Web Managers Table 4-4: 80xx High Power Midspan Port Status Indications
Port LED Color
Port Load Conditions Non-active load or unplugged port
Port Voltage Power to the port is disconnected. No DC voltage present on spare pairs Continuous nominal DC voltage is present on the spare pairs
Off
Green
Active load is plugged and power is provided both on the data & spare pairs (PD device may consume up to 20Watts on each pair, and up to 40Watts total) Power is provided only on data or spare pairs (max power = 20Watts) Overload conditions; or short; or forced external voltage feed (constant DC) into the port Port can't be activated since total aggregated power exceeds maximum power budget
Green blinking
Continuous nominal DC voltage is present only on the data or spare pairs, and not on both of them Power to the port is disconnected. No DC voltage is present on the spare pairs Power to the port is disconnected. No DC voltage is present on the spare pairs
Orange
Orange blinking
PowerDsine
30
Power over Ethernet Solutions
Remote Web Managers 4.3.1.3 Ports Power Status Table Ports Power Status Table displays the following parameters:
No. 1. 2.
Parameter Total Power Consumption Active Power Source
Description
Total power consumed by all PDs Maximum available Power from internal Power Supply, or external DC Power Source (applicable only for Midspan with 48VDC option) Voltage level supplied to PDs Detection method selected by the user from the System Configuration - Product Parameters menu (see Para. 4.4.5) Midspan status display with the following options: 1. Active normal operation 2. Midspan has no firmware - Midspan has no firmware indication 3. Internal Comm. Failure internal communication failure 4. Midspan firmware update - firmware update indication
3. 4.
System Voltage PD Detection Method Midspan Status
5.
PowerDsine
31
Power over Ethernet Solutions
Remote Web Managers 4.3.1.4 General Power Status Table Pressing the i image, or the RJ45 jack, will cause a new popup WEB page to appear with detailed port description information:
No. 1. 2. 3.
Parameter
Description
Port Power Max Pwr
4. 5.
Priority Terminal Type / Description Class
Was port Enabled or Disabled Actual consumed power by individual PD Maximal allocated power per Port as configured in the Port Configuration Detailed screen (see Para. 6.13) Current priority level set by the user Textual terminal description as configured in the Port Configuration Detailed screen (see Para. 6.13) PD device class (applicable only for Midspan family 65xx)
6.
PowerDsine
32
Power over Ethernet Solutions
Remote Web Managers
4.3.2
View Network & Security Configuration Screen
View - Network Configuration Screen displays the following parameters: IP in-Use currently used IP address/Mask/ Gateway Remote Trap SNMP Managers List- list of appointed managers Static Network Configuration manually configured Network parameters Remote Access Remote managers that may access the Midspan (SNMP v1/v2 and SNMPv3, Telnet) and enabled/disabled SSL WEB encryption Remote Servers IP address of remote SysLog Server, IP address of remote NTP ( Network Time Protocol) Server. Date & Time Unit system time (GMT), as acquired from the NTP Server
PowerDsine
33
Power over Ethernet Solutions
Remote Web Managers 4.3.2.1 IP in-Use IP in-Use window displays the current IP address being used with the following parameters:
No. 1.
Parameter
Description
Obtain IP by DHCP IP Address
2.
3.
IP Mask
4.
Default Gateway
Indicates how the IP is obtained as previously set by the user (see System Configuration Network - Para 6.6). IP address, numerical address which indicates a particular computer within a network The definition of the network portion of the IP address. This location must be configured in such a way that all IP addresses up to and including the local gateway are allowed. The IP address of the local Gateway, which enables communication settings to other LAN segments.
4.3.2.2
Remote Trap SNMP Managers List This List displays all the user pre-configured managers (see Para. 6.7 for further details). All listed managers receive standard and private traps from the Midspan.
PowerDsine
34
Power over Ethernet Solutions
Remote Web Managers
4.3.2.3
Static Network Configuration Static Network Configuration window displays Network configuration in cases where Static IP is selected (and not DHCP). In cases where the unit is configuered as Static IP, both IP-In Use and Static configuration tables will be identical. The following static parameters appears:
No. 1. 2.
Parameter
Description
IP Address IP Mask
3. 4.
Default Gateway MAC Address
Internet address, numerical address which indicates a particular computer within a network The definition of the network portion of the IP address. This location must be configured in such a way that all IP addresses up to and including the local gateway are allowed. IP address of the local Gateway, which enables communication settings to other LAN segments. Media access control address. A 12-digit hexadecimal address used by the media access control layer of an 802.2 connection. connection with Host Integration Server.
PowerDsine
35
Power over Ethernet Solutions
Remote Web Managers 4.3.2.4 Remote Access The Remote Access window displays the remote managers that may access the unit (SNMPv1/v2 , SNMPv3, Telnet) and enabled/disabled SSL WEB encryption.
No. 1. 2.
Parameter
Description
Enable SNMPv2 Enable SNMPv3
Indicates enabled/disabled SNMP v1/v2 Indicates enabled/disabled SNMPv3, due to security considerations. Note that it is not recommended to enable SNMPv2 while SNMPv3 is in use! When this box is checked, the user may access the unit, via the Telnet protocol. When this box is checked, indicates that WEB pages are encrypted by SSL.
3. 4.
Enable Telnet Enable Web SSL Encryption
PowerDsine
36
Power over Ethernet Solutions
Remote Web Managers 4.3.2.5 Remote Servers Remote Servers window displays the IP address of a remote SysLog Server, and an IP address of remote NTP ( Network Time Protocol) Server.
No. 1. 2.
Parameter
Description
NTP Server SysLog Server
IP address of a remote Network Time Protocol (NTP) Server Log Events sent to the IP address via SysLog protocol Note that an IP address 0.0.0.0 prohibits the unit from sending Log Events
4.3.2.6 Date and Time Date and Time window displays unit system time (GMT), as acquired from the NTP Server.
No. 1. 2.
Parameter
Description
Time (GMT) Date (D/M/Y)
Time (HH:MM:SS) as acquired from the NTP Server Date (DD/MM/YYYY) as acquired from the NTP Server If the unit fails to acquire time from the NTP Server, it will display the elapsed time since 1/1/2005
Power over Ethernet Solutions
PowerDsine
37
Remote Web Managers
4.3.3
View - Product Information
View - Product Information screen displays the following parameters (see Figure 4-5):
Figure 4-5: View - Product Information Screen
No. 1. 2. 3. Parameter Description
Product Nickname Serial Number Software Version
Unit nickname as configured by network administrator Midspan serial number Current software version
PowerDsine
38
Power over Ethernet Solutions
Remote Web Managers
4.4
System Configuration Screen
System Configuration Screen allows the following Configurations: (Figure 4-6): Network Configuration SNMP Configuration SNMPv3 Configuration Security Configuration Product Parameters-Configuration System Configuration - Maintenance
Figure 4-6: System Configuration Screen
4.4.1
System Configuration Network Screen
Network Configuration screen (see Figure 4-7) allows Configuration of the following parameters (see also para. 4.3.2.1): IP Address, Subnet Mask, Default Gateway.
PowerDsine
39
Power over Ethernet Solutions
Remote Web Managers
Figure 4-7: System Configuration Network Screen
No. 1. Button/Checkbox Description
If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Diplodocs provides you a fast and easy access to the user manual POWERDSINE POWERVIEW PRO. POWERDSINE offer a product for which we do not have the user manual? Let us know what you are looking for: site Internet, histoire, actualité, filiales, site Internet, mode d'emploi, driver, avis des utilisateurs, meilleur prix des produits, forum d'assistance aux problèmes, annuaire des marques, annuaire des constructeurs, répertoire des marques, répertoire des constructeurs, site Internet de la marque, site Internet du constructeur Diplodocs allows you to download user manual POWERDSINE POWERVIEW PRO, user guide POWERDSINE POWERVIEW PRO, instructions POWERDSINE POWERVIEW PRO, owner's manual POWERDSINE POWERVIEW PRO, online manual POWERDSINE POWERVIEW PRO.Access web reviews POWERDSINE POWERVIEW PRO, , Ethernet card, WIFI, Bluetooth & Powerline. |
![]() |
Include the add-on to download manuals from your site, forum or blog | ![]() |
Frequently Asked Questions | ![]() |
Contact Diplodocs team | ![]() |
Last searches Last additions |
![]() |
Sitemap | ![]() |
|||
| Brands starting with A B C D E F G H I J K L M N O P Q R S T U V W X Y Z # | |||||||||||||
|
|
Copyright © 2005 - 2008 - Diplodocs -
All Rights Reserved. Designated trademarks and brands are the property of their respective owners. |