User guide QUANTUM ADDENDUM STDX401LW
Detailed instructions for use are in the User's Guide. Addenda to the Scorpion 40 Installation Manual
IMPORTANT: This sheet contains updated information that supersedes the information presented in the Scorpion 40 Installation Manuals (PN 10005601-001 or 10006592-001).
Use only approved DDS-4 cartridges
Only approved Seagate-brand media and cleaning cartridges have been tested and certified for operation in this drive. Other cartridges may be incompatible or cause damage to the drive. The following Seagate cartridges are certified: Recording cartridge-STDM40; Cleaning cartridge-STDMCL. For optimal performance you must use a 150 meter DDS-4 data cartridge (Model Number - STDM40).
Miscellaneous Notes
1) The "Clean" and "Media" LEDs on the front of the drive are green. The "Drive" LED is yellow. 2) SCSI IDs 8-15 are only recognized if dip switch 9 is set to "On." 3) The drive must be power-cycled for a change in SCSI ID to take effect. 4) A cleaning cartridge that is used up is not ejected automatically. Press the Eject button to eject it.
DIP-Switch Configurations for Windows NT, Novell, and UNIX operating systems
The following table summarizes the correct settings for the operating-system configuration switches (Switches 5 through 8) on the Scorpion 40 drive: Operating System / tape driver software
Windows NT 4.0 w/ native backup applet using 4mmDAT.SYS driver from Microsoft or STDAT4.SYS driver from Seagate Novell 4.11 w/ native backup applet using TAPEDAI driver or NWTAPE.CDM driver dated before 11/3/99 Novell 4.11 w/ native backup applet using NWTAPE driver dated after 11/3/99 Novell 5.x w/ native backup applet using NWTAPE.CDM driver dated before 11/3/99 Novell 5.x w/ native backup applet using NWTAPE.CDM driver dated after 11/3/99 Linux SCO (ODT and Open Server) installation using MAKDEV utility SCO UnixWare 7.x DEC UNIX Sun UNIX SGI UNIX HP-UNIX IBM AIX Switch 5 ON Switch 6 ON Switch 7 ON Switch 8 ON
OFF ON OFF ON ON OFF ON OFF ON ON ON ON
ON ON ON ON ON ON ON ON OFF ON ON OFF
ON ON ON ON ON ON ON ON ON ON OFF ON
OFF ON OFF ON ON OFF ON ON ON ON ON OFF
System-specific corrections and additions to the manual
Windows NT If you use Windows NT 4.0 with the 4mmDAT.SYS driver from Microsoft, you must set Switch 10 (the Inquiry-String switch) to OFF. If you use the STDAT4.SYS driver from Seagate, you can leave the Switch 10 in its default position (ON). Novell Operating Systems:
Novell 4.11
There are two possible ways to configure the Scorpion 40 to work with Novell 4.11, depending on which tape driver you use. (continued on back)
Addenda to the Scorpion 40 Installation Manual PN: 10007100-001, Rev. B, May, 2001
Configuration 1: If you are using the existing Novell TAPEDAI driver or a version of the NWTAPE driver created before 11/3/99, you must change the Operating-System Configuration Dip switches so that switches 5 and 8 are OFF, as shown in the table above. This is different from their default settings (all switches ON). Configuration 2: If you use the latest Novell NWTAPE driver (available on the Novell web site), the Operating-System Configuration Dip switches should be left in their default positions (all switches ON). From the administrator workstation, place the new NWTAPE driver in the same directory as the TAPEDAI driver (usually the system directory). Edit any .ncf files, such as autoexec.ncf, which call the TAPEDAI driver and replace calls to TAPEDAI with NWTAPE. Do not delete the TAPEDAI driver, because it may come in handy in resolving future problems. Novell 5.x
There are two possible ways to configure the Scorpion 40 to work with Novell 5.x, depending on which tape driver you use.
Configuration 1: If you are still using the original Novell NWTAPE driver or any version created before 11/3/99, you must change the Operating-System Configuration Dip switches so that switches 5 and 8 are OFF, as shown in the table on the front of this sheet. This is different from their default settings (all switches ON). Configuration 2: If you use the latest Novell NWTAPE driver (available on the Novell web site), the Operating-System Configuration Dip switches can be left in their default positions (all switches ON). Before installing the new NWTAPE driver, first rename the old NWTAPE driver (usually found in the system directory). Then copy the new version of NWTAPE into the same directory. Do not delete the old driver, because it might come in handy in resolving future problems.
DEC UNIX The Operating-System Configuration Dip switch settings in the manual are incorrect. In a DEC UNIX environment switches 5 through 8 should be set as shown in the table on the front of this sheet. Sun UNIX The Operating-System Configuration Dip switch settings in the manual are incorrect. In a Sun UNIX environment switches 5 through 8 should be set as shown in the table on the front of this sheet. In addition, in the Solarix 2.x installation, the lines added to the st.conf file in the manual are incorrect. The correct text is:
tape-config-list= "SEAGATE DAT 06240-XXX","Seagate DAT Drive","SEAGATE_DAT"; SEAGATE_DAT = 1,0x34,0,0xd639,4,0x00,0x8C,0x8C,0x8C,3;
Note: The inquiry string above contains four spaces between the word DAT and the value 06240. SGI UNIX Wherever the text "05573" (as in "DAT 05573") appears in the configuration text, it should be replaced by "06240". Also in configuring Irix V6.5, the following text string:
40, 12*60, 12*60, 12*60, 512, 512*512,
is incorrect and should be replaced by:
40, 12*60, 12*60, 12*60, 3*3600, 512, 512*512,
HP UNIX The Operating-System Configuration Dip switch settings in the manual are incorrect. In an HP UNIX environment switches 5 through 8 should be set as shown in the table on the front of this sheet. In addition, the configuration instructions apply only to HP-UX versions 10.2 and 11.
Addenda to the Scorpion 40 Installation Manual
PN: 10007100-001, Rev. B, May, 2001
If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Diplodocs provides you a fast and easy access to the user manual QUANTUM ADDENDUM STDX401LW. QUANTUM offer a product for which we do not have the user manual? Let us know what you are looking for: site Internet, histoire, actualité, filiales, site Internet, mode d'emploi, driver, avis des utilisateurs, meilleur prix des produits, forum d'assistance aux problèmes, annuaire des marques, annuaire des constructeurs, répertoire des marques, répertoire des constructeurs, site Internet de la marque, site Internet du constructeur Diplodocs allows you to download user manual QUANTUM ADDENDUM STDX401LW, user guide QUANTUM ADDENDUM STDX401LW, instructions QUANTUM ADDENDUM STDX401LW, owner's manual QUANTUM ADDENDUM STDX401LW, online manual QUANTUM ADDENDUM STDX401LW.Access web reviews QUANTUM ADDENDUM STDX401LW, , Hard Drive, NAS, USB Key & Other external Storage. |
![]() |
Include the add-on to download manuals from your site, forum or blog | ![]() |
Frequently Asked Questions | ![]() |
Contact Diplodocs team | ![]() |
Last searches Last additions |
![]() |
Sitemap | ![]() |
|||
| Brands starting with A B C D E F G H I J K L M N O P Q R S T U V W X Y Z # | |||||||||||||
|
|
Copyright © 2005 - 2008 - Diplodocs -
All Rights Reserved. Designated trademarks and brands are the property of their respective owners. |