M219 Additional room amplifier
M Series
Contents
M219 Additional room amplifier Safety Installation and operation Safety measures Warranty Front view Connection plan Detailed description [1] Local IN 1 2 3 [2] PRE OUT [3] DIL Setup switches (1) IR receiver (2) Pre Out (3) Input IN (4-5) Local inputs (6-7-8) Addressing [4] M219 Link [5] IR Link [6] Input IN [7] Channel Select [8] IN Revox MR Bus [9] OUT Revox MR Bus [10] R-L Speakers [11] Fuse [12] AC Power M219 cabling plan diagram Multiroom Cabling Personal M219 settings Technical data Guarantee Delivered items 2 3 3 4 4 5 6 7 7 7 8 8 9 10-11 12 12 13 13 14 14-15 15 15 16 16 16 17 18 18 19 20 20
1
M219 Additional room amplifier
M Series
M219
Additional room amplifier
General
The M219 is a digital Additional Room Amplifier from the newest M Series in the REVOX Multiroom programme. It is used for the reproduction of music in the additional rooms in a Multiroom system and can also supply the listener with current information through an additional display. The M219 receives the signals from a selected source (CD, Tuner, Server ...) in the main room through a multiroom bus cable. Volume, balance, bass and treble settings can be made in individually in each room. Also, up to 3 local sources can be connected and listened to in each additional room. If you want "concealed" operation, various wall-mounted controllers or IR receivers can be connected. You should avoid installing it in locations where: - there is direct sunlight - it is next to a heat source - there is poor ventilation - there is a lot of dust in the atmosphere - it is unstable - there is a risk of splashing - there is high humidity Furthermore you may not place objects filled with liquids, such as vases, or naked flame sources, such as lighted candles, on the M219.
Stacking several M219s If you want to stack several M219s on top of each other, we recommend that you use the corresponding installation kit, with the Part no. 1.551.313.00.
Installation
M219 Room-Amplifier
The M219 should be installed in such a way that the ventilation slots are not covered up and so that there is a gap of at least 5 cm ( 2 in) between the unit and any walls or furniture.
M219 Room-Amplifier
M219 Room-Amplifier
2
M219 Additional room amplifier
M Series
Safety
Please take note of the information shown on the labels on the rear of the unit. Housings should not be removed, in order to avoid the danger of an electric shock. Maintenance and repairs should only be carried out by qualified personnel.
Installation and operation
Please check the unit and accessories for any signs of transit damage, once you have unpacked it. Please read the operating instructions carefully before starting to use the unit. Keep the documentation somewhere safe for future reference. If the unit shows any signs of damage or has come into contact with any fluids should not be connected to a power supply. Only use the power cable supplied. Before connecting the power, the power supply and unit connection values (power voltage, frequency) must be checked. The fuse used in the unit must conform to the factory definitions contained in the "Technical data" section of this manual.
This symbol warns of "dangerous voltages" within the unit. In the case of contact with the corresponding components, the level of voltage can cause an electric shock.
!
This symbol indicates important advice for operation and maintenance in this documentation.
3
M219 Additional room amplifier
M Series
Safety measures
Operational anomalies In the case of any unusual noises or smells coming from the unit, remove the power cable immediately. Have the unit checked as soon as possible by your supplier. Do not open the unit The unit should not be opened because of the risk of electrocution. Periods of non-use If the unit is not going to be used for a longer period of time, the power cable should be unplugged from the socket as a safety precaution. Foreign objects Fluids, flammables or other foreign objects should not find their way into any of the unit's openings as this can result in breakdowns, fire or an electric shock. Power cable Always pull the plug out of the socket while holding the plug housing and not the cable.
Warranty
Device regulations REVOX offers a warranty in EU/EEA countries on products bought within the EU, in addition to the statutory warranty provided by the retailer. The warranty covers material and labour during the period of the warranty, which is stipulated in the individual EU countries by the REVOX Sales Partners. In all countries, the terms of warranty from the REVOX reseller is offered in addition to the statutory regulations. You must be able to prove that the product was bought from an approved REVOX Partner when making any warranty claim. The warranty is invalidated if any inappropriate or unprofessional repairs have been carried out on the unit.
4
M219 Additional room amplifier
M Series
M219- Front view
[A]
[B]
[C]
M219 Room-Amplifier
[A] IR Sensor The InfraRed sensor receives signals from the remote control or from any other IR control devices, such as the PDAs for the music server. Switching the IR sensor off If required, the IR sensor can be switched off using the SETUP DIL switch [3] on the rear of the M219. [B] Status LED
[C]
Ventilation slots
The ventilation slots on the front and the top of the M219 must always be left clear of obstructions. The M219 should be installed in such a way that the ventilation slots are not covered up and so that there is a gap of at least 5cm between the unit and any walls or furniture.
The blue status LED gives information about the current state of the M219. LED display Permanently dark Permanently lit Rapid flashing Rapid flashing Slow flashing Single flash Double flash Triple flash M219 Status M219 standby mode M219 active Breakdown, overload Min/max position reached (Volume, Bass, Treble, Balance) IR receive (RC5 or RC6 Codes) LOCAL 1 or general change of source LOCAL 2 LOCAL 3
5
M219 Additional room amplifier
M Series
Connection plan
Rear view
[1] [2] [3] [4] [5] [6]
M219 LINK LOCAL IN
1
L
2
3
PRE OUT
SETUP
+ IN -
+-
OUT
12 3 4 5 6 7 8
R
1234
CHANNEL SELECT
IN
OUT MR-BUS
+ R-L+ SPEAKERS
FUSE
AC - POWER
[7]
[8]
[9]
[10]
[11]
[12]
Short descriptions
[1] [2] [3] [4] [5] Local Cinch inputs L/R Preamp outputs L/R DIL setup switches M219-Link display connector IR receiver or wall-mounted remote control connections Switching voltage input
[7] [8] [9]
Stereo/ Mono switch Multiroom Bus input Multiroom Bus output
[10] Speaker connections L/R [11] Fuse [12] Power connection
[6]
6
M219 Additional room amplifier
M Series
Detailed descriptions
[1] LOCAL IN 1 2 3 [2] PRE OUT
Local Cinch inputs L/R The M219 has 3 local line inputs for a CD player, video recorder or TV, for example, which are located directly in the room where the M219 is. The local audio inputs are activated by the Local key on the (wallmounted) remote control. You can scroll through a loop of the local inputs by repeatedly pressing the Local key:
Preamp outputs L/R Using the M219s preamp outputs, additional output devices can be supplied, or the REVOX digital speakers can be operated through the REVOX DLC-2. The configuration of this audio output is described in detail on Page 9.
[3]
(Local 1 (Local 2) (Local 3)
SETUP
DIL Setup switches The basic settings of the M219 are configured through these DIL setup switches.
The number of active inputs that are actually used can be set through Setup DIL switches 4 & 5. This saves you unnecessary scrolling through non-active inputs. If, for example, only inputs 1 and 2 are used, you can set the switches so that you only have to scroll through Inputs 1 & 2. Input 3 is skipped.
1234 5 678
Important Configuration can only be carried out through the setup switches when the M219 is disconnected from the power supply. Otherwise, the new settings are not activated. The function of each individual switch is described on the next page.
7
M219 Additional room amplifier
M Series
DIL setup switches
NO 1 2 3 4 5 6 7 8 Function M219 IR eye on/off Pre-Out: Fixed Volume LOCAL IN 1 Fixed Volume Factory setting On Off Off On On Off Off Off
Number of local inputs Number of local inputs M219 address M219 address M219 address
Please note: The switch is in the ON position when it is down
You can enter your own personal DIL switch settings in a table included on the last pages of this manual, providing you with a record for future reference.
M219 infrared receiver In some cases, e.g. in buildings with glass internal walls, it can be useful to switch the M219 IR receiver off, in order to avoid operational conflicts with other devices. IR Function IR - Off IR - On DIL switch 1 Off On DIL position
1
1
8
M219 Additional room amplifier
M Series
(2) PRE OUT Two operating modes are possible with the M219's preamp output: Floating Volume (Factory setting from serial # 2000): This is the standard mode setting. In this case, the PRE OUT level changes parallel to the speaker level. This means that as you increase the volume at the speakers, for example, the PRE OUT level is automatically changed at the same time. Application: You should select Floating Volume mode if, for example, and additional output device or an active subwoofer is connected, whose volume should also be controlled by the M219. This means that the M219 speaker output remains active.
Fixed Volume: In this mode, the volume control and the M219 output devices are deactivated, i.e. the volume cannot be controlled by any wall-mounted or infrared remote control. The speakers connected to the M219 remain silent. Irrespective of whether it is addressed through the multiroom bus or a local input (Local IN 1 2 3), each source has a standard level, the so-called Line Level. Application: The Fixed Volume mode has been conceived principally for applications where digital REVOX speakers are to be connected to the M219 over a DLC2 interface.
PRE OUT Floating Volume Fixed Volume
DIL switch 2 Off On
DIL position
2
2
9
M219 Additional room amplifier
M Series
(3) Voltage input IN
(from serial # 2000)
Using the voltage input IN on the M219, the local audio input LOCAL IN 1 can be activated by the application of 5 Â 24 VDC. This means that as soon as the voltage is present at IN, the M219 switches on automatically and selects the input LOCAL IN 1. When the voltage is removed from input IN, the M219 switches off again automatically, as long as no other source apart from LOCAL IN 1 was addressed. With DIL switch (3), you can define whether the volume control is handled by the M219 (Floating Volume) or the connected (TV) device (Fixed Volume). With Fixed Volume, the M219's volume control is deactivated and the audio signal at LOCAL IN 1 is transmitted with a fixed strength. In this way, volume control is carried out with the TV remote control. The volume control setting set by DIL switch 3 only has an effect on the local audio input LOCAL IN 1. All other sources are unaffected and operate normally. LOCAL IN 1 Floating Volume Fixed Volume Application: DIL switch 3 Off On DIL position
3
3
Many devices output a voltage as soon as they are switched on. If you connect the voltage output of such a device with the IN voltage input on the M219 and the audio output with the local audio input LOCAL IN 1, the M219 will switch on automatically with the other device and transmit the sound. If your device doesn't have a voltage output, you can supply voltage to the input using a sensor-switch multiple socket outlet (Master/Slave socket outlet) and a normal plug-in power supply (5-24 V= / DC). Please refer to the diagram on Page 11.
10
M219 Additional room amplifier
M Series
Cabling: Voltage input IN
Audio Local (audio)-source OUT e.g. TV
WITHOUT
WITH
+
-
switching-voltage output
5-24V OUT DC
M219 LINK LOCAL IN
1
L
2
3
PRE OUT
SETUP
+ IN -
+-
IN
ON 1 2 3 4 5 6 7 8 115V / T1A L
R ON 1 2 3 4 CAUTION
RiSK OF ELECTRIC SHOCK DO NOT OPEN
CHANNEL SELECT
IN
OUT MR-BUS
+ R-
-L+
FUSE 230V / T0,5A L
AC - POWER
SPEAKERS
Please note: SCART sockets Many devices such as SAT receivers, video recorders or DVD players output a switching voltage through the SCART socket as soon as they are switched on. On a standard SCART socket, PIN 8 outputs the positive voltage (+) and PIN 4 or 14 is the earth (-).
The principle of Master/Slave socket outlets With this type of socket outlets, the control device (the TV in the above example) is plugged into the master socket while all other devices are connected through the slave sockets. As long as the master device is not switched on, all slave sockets remain switched off. Once the master device is switched on, all the slave sockets (the plug-in power supply in the above example) are switched on at the sam ...