User guide ROLLS RP282
Detailed instructions for use are in the User's Guide. RP282 Dual Tube Compressor/Limiter
RELEASE
Dual Tube Compressor/Limiter
METER 3 0 3 0 10 20 0 ms 500
+4 REF OUTPUT GAIN REDUCTION
5
3 6
10 20
5
3 6
@*
CHANNEL ONE
@*
CHANNEL TWO
STEREO LINK METER
0
ms
500
RP282a
OUTPUT LEVEL ACTIVE
THRESHOLD 4:1
RATIO 5:1
ATTACK
RELEASE
Channel One
ACTIVE O O 0 -25 dB +10 2:1 4:1 O :1 O 5:1 .5 ms 100 100 ms 5
Channel Two
O O 0 -25 dB +10 2:1 O :1 O .5 ms 100 100 ms 5
ROLLS CORPORATION SALT LAKE CITY, UTAH 7/99
OWNERS MANUAL
TABLE OF CONTENTS Introduction Inspection Front Panel Description Rear Panel Description Specifications Operation Warranty 1 2 3 3 4 5
LIMITED WARRANTY
This product is warranted to the original consumer purchaser to be free from defects in materials and workmanship under normal installation, use and service for a period of one (1) year from the date of purchase as shown on the purchaser's receipt. The obligation of Rolls Corporation under this warranty shall be limited to repair or replacement (at our option), during the warranty period of any part which proves defective in material or workmanship under normal installation, use and service, provided the product is returned to Rolls Corporation, TRANSPORTATION CHARGES PREPAID. Products returned to us or to an authorized Service Center must be accompanied by a copy of the purchase receipt. In the absence of such purchase receipt, the warranty period shall be one (1) year from the date of manufacture. This warranty shall be invalid if the product is damaged as a result of defacement, misuse, abuse, neglect, accident, destruction or alteration of the serial number, improper electrical voltages or currents, repair, alteration or maintenance by any person or party other than our own service facility or an authorized Service Center, or any use violative of instructions furnished by us. This one-year warranty is in lieu of all expressed warranties, obligations or liabilities. ANY IMPLIED WARRANTIES, OBLIGATIONS, OR LIABILITIES, INCLUDING BUT NOT LIMITED TO THE IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE, SHALL BE LIMITED IN DURATION TO THE ONE YEAR DURATION OF THIS WRITTEN LIMITED WARRANTY. Some states do not allow limitations on how long an implied warranty lasts, so the above limitation may not apply to you. IN NO EVENT SHALL WE BE LIABLE FOR ANY SPECIAL, INCIDENTAL OR CONSEQUENTIAL DAMAGES FOR BREACH OF THIS OR ANY OTHER WARRANTY, EXPRESSED OR IMPLIED, WHATSOEVER. Some states do not allow the exclusion or limitation of special, incidental or consequential damages so the above limitation or exclusion may not apply to you. This warranty gives you specific legal rights, and you may also have other rights which vary from state to state.
5
OPERATION
INTRODUCTION Congratulations and thank you for purchasing the Bellari RP282 Dual Tube Compressor/Limiter. We recommend that you take a moment and read this manual as it provides information that will help you in using your unit to its fullest potential. The RP282 provides smooth, natural compression and clear sonic quality and performance for the working musician, studio operator or anyone who needs a comp/limiter with warm, smooth analog sound. Each channel uses one ROLLS premium 7025 tube in a unique configuration to give superior signal control. The unit has both XLR and 1/4" inputs and outputs. Plus, it has a Side Chain input and output for each channel. The side chain provides direct access to the detector circuits. INSPECTION 1. Unpack and inspect the RP282 box and package. Your RP282 was carefully packed at the factory in a protective carton. Nonetheless, be sure to examine the unit and the carton for any signs of damage that may have occurred during shipping. If obvious physical damage is noticed, contact the carrier immediately to make a damage claim. We suggest saving the shipping carton and packing materials for safely transporting the unit in the future. 2. Please complete the Warranty Registration Card and return it to the factory.
THE FOLLOWING SETTINGS ARE APPROXIMATE, THEY ARE LISTED AS SUGGESTIONS ONLY.
VOCAL COMPRESSION The most effective way to connect your RP282 for vocal compression is by patching it into a channel insert of your mixing board. You will need an "insert" cable like the one shown. Connect the INPUT of the RP282 to the mixer's Send jack, and the OUTPUT to the mixer's Return. Set the level to the RP282 compressor by speaking or singing into the microphone at the same level used during performance. Set the Meter switch to Output, and adjust the gain control on your mixer so the RP282 meter moves to approximately 0. Press in the Active button to put the RP282 in compression mode. See the example diagram below for settings.
OUTPUT LEVEL -20 THRESHOLD -10 4:1 RATIO 5:1 ATTACK RELEASE
- OO
dB
+22
-20
dB
+20
2:1
O :1 O
.5
ms
100
.1
Sec
2
DRUM COMPRESSION The RP282 may be used to compress various drum parts for a smooth, tight drum sound as well as more control over a final mix. Connect your RP282 to the insert of your mixer and set the input level as directed above. Shown below is an example of a kick or snare drum compression setting.
OUTPUT LEVEL -20 THRESHOLD -10 4:1 RATIO 5:1 ATTACK RELEASE
- OO
dB
+22
-20
dB
+20
2:1
O :1 O
.5
ms
100
.1
Sec
2
4
1
FRONT PANEL DESCRIPTION
REAR PANEL DESCRIPTION
NOTE: Channel One descriptions are identical to Channel Two
ACTIVE SWITCH: Engages and disengages the compression. OUTPUT LEVEL: Varies the overall signal level from the RP282. THRESHOLD: Sets the level at which the incoming signal must overcome in order for the RP282 to begin compressing. RATIO: Adjusts the signal to compression ratio. This sets the amount of increase in input signal required to raise the output signal 1 dB. ATTACK: Varies the amount of time taken for the RP282 to begin compressing after the Threshold level has been reached. RELEASE: Varies the amount of time taken for the RP282 to return to normal gain once the signal has dropped below the Threshold level. METER SWITCH: Switched the signal metering from indicating the output jack level, to indicating the amount of gain reduction. VU METER: Indicates either the output signal level, or the amount of gain reduction, depending on the position of the Meter Switch. NOTE: THE INPUT SIGNAL LEVEL MAY ALSO BE INDICATED BY PRESSING OUT THE ACTIVE SWITCH AND BYPASSING THE COMPRESSOR CIRCUITS. POWER SWITCH: Turns the RP282 main power on and off.
NOTE: Channel One descriptions are identical to Channel Two.
OUTPUTS: XLR balanced and 1/4" unbalanced connectors for connecting the RP282 to a mixer or other line level input. SIDE CHAIN INPUT: 1/4" unbalanced jack for receiving incoming signals to directly access the detector circuit of the compressor. SIDE CHAIN OUTPUT: 1/4' unbalanced jack for sending out the signal from the RP282. This jack may also be used as a pre-Output Level output. IMPORTANT: The Side Chain Inputs and Outputs are not effects loops, they break the signal path of the RP282 control circuitry. INPUTS: XLR balanced and 1/4" unbalanced connectors for connecting line level signals to the RP282.
SERIAL NUMBER MODEL RP583
583-
CAUTION
120 VAC 50/60 Hz 15 VA
RISK OF ELECTRIC SHOCK DO NOT OPEN
OUTPUT SIDE CHAIN
INPUT
OUTPUT SIDE CHAIN
INPUT
WARNING: DO NOT EXPOSE THIS
OR MOISTURE.
MADE IN U.S.A.
EQUIPMENT TO RAIN
CAUTION: TO REDUCE THE RISK OF ELECTRIC SHOCK DO NOT
NOT REMOVE BACK. NO USER SERVICABLE PARTS INSIDE. REFER SERVICING TO QUALIFIED SERVICE PERSONNEL. RISQUE DE CHOC - NE PAS ENLEVER
BAL UNBAL INPUT OUTPUT UNBAL BAL BAL UNBAL INPUT OUTPUT UNBAL BAL
CHANNEL TWO
CHANNEL ONE
SPECIFICATIONS Frequency Response: Input Impedance: THD + Nosie: S/N Ratio: Max Gain: Indicators: Input/Output jacks: Dimensions: Power: Approval:
OUTPUT LEVEL ACTIVE
THRESHOLD 4:1
RATIO 5:1
ATTACK
RELEASE
Dual Tube Compressor/Limiter
METER 3 0 3 0 10 20 5 3 6 10 20 5 3 6
Channel One
ACTIVE O O 0 -25 dB +10 2:1 4:1 O :1 O 5:1 .5 ms 100 100 ms 500
+4 REF OUTPUT GAIN REDUCTION
@*
CHANNEL ONE
@*
CHANNEL TWO
Channel Two
O O 0 -25 dB +10 2:1 O :1 O .5 ms 100 100 ms 500
STEREO LINK METER
RP282a
10 Hz - 40 kHz 10K 9 balanced 1M 9 unbalanced 0.1% typical 103 dB 40 dB (Threshold @ -40 dB) (2) Active LEDs, (2) analog VU meters XLR balanced and 1/4" unbalanced 3.5" x 6" x 19" (89 x 162 x 482 mm) 120 VAC, (230 VAC) 15 VA CSA NRTL (Pending)
2
3
If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Diplodocs provides you a fast and easy access to the user manual ROLLS RP282. ROLLS offer a product for which we do not have the user manual? Let us know what you are looking for: user guide, owner's manual, online manual, operating instructions, quick start guide, mounting instructions, schematics, service manual, installation instructions, RTFM. Diplodocs allows you to download user manual ROLLS RP282, user guide ROLLS RP282, instructions ROLLS RP282, owner's manual ROLLS RP282, online manual ROLLS RP282.Access web reviews ROLLS RP282, , DVD Player, DVD Recorder, Home Theater, Amplifier & Hi-Fi Audio. |
![]() |
Include the add-on to download manuals from your site, forum or blog | ![]() |
Frequently Asked Questions | ![]() |
Contact Diplodocs team | ![]() |
Last searches Last additions |
![]() |
Sitemap | ![]() |
|||
| Brands starting with A B C D E F G H I J K L M N O P Q R S T U V W X Y Z # | |||||||||||||
|
|
Copyright © 2005 - 2008 - Diplodocs -
All Rights Reserved. Designated trademarks and brands are the property of their respective owners. |