Detailed instructions for use are in the User's Guide. S Class Signal Processors
CH 1
HIGH
GAIN REDUCTION dB 30 24 18 12 6 4 2 1
LINK
CH 2
HIGH
GAIN REDUCTION dB 30 24 18 12 6 4 2 1
CH 3
HIGH
GAIN REDUCTION dB 30 24 18 12 6 4 2 1
LINK
CH 4
HIGH
GAIN REDUCTION dB 30 24 18 12 6 4 2 1
POWER
TRIGGER
+4 20
ATTACK
.25
HOLD
1
RELEASE
1
RANGE 40
IN/OUT
TRIGGER
+4 20
ATTACK
.5
HOLD
1
RELEASE
1
RANGE 40
.1
TRIGGER
+4 20
ATTACK
.5
HOLD
1
RELEASE
1
RANGE 40
IN/OUT
TRIGGER
+4 20
ATTACK
.5
HOLD
1
RELEASE
1
RANGE 40
4 CHANNEL GATE
.1
KHz 10
.1
KHz 10
KHz 10
.1
KHz 10
-50
dBu +20
.3
mSec
300
.01 Sec
4
.02
Sec
5
1
dB 80
-50
dBu +20
.3
mSec
300
.01 Sec
4
.02
Sec
5
1
dB
80
-50
dBu +20
.3
mSec
300
.01 Sec
4
.02
Sec
5
1
dB
80
-50
dBu +20
.3
mSec
300
.01 Sec
4
.02
Sec
5
1
dB
80
30
LOW
Hz
3K
30
KEY
KEY LISTEN
DUCKER
IN/OUT
LOW
Hz
3K
30
KEY
KEY LISTEN
DUCKER
LOW
Hz
3K
30
KEY
KEY LISTEN
DUCKER
IN/OUT
LOW
Hz
3K
KEY
KEY LISTEN
DUCKER
4 CHANNEL GATE
Safety Instructions
Caution: To reduce the hazard of electrical shock, do not remove cover or back. No user serviceable parts inside. Please refer all servicing to qualified personnel.
FOR CONTINUED PROTECTIO N AGAINST RISK OF FIRE, REPLACE ONL Y W ITH SAME TYPE FUSE UTILISER UN FUSI B LE DE RECHANGE DE M Ê ME TYPE
CAUTION
ATT E NTION
DO NOT EXPOSE THIS EQUIPMENT TO RAIN OR MOISTURE RISQUE DE C HO C E LE C TRONIQUE NE PAS OU V RIR
WAR NING AV IS
RISK OF ELECTRIC SHOCK DO NOT OPEN
WARNING: To reduce the risk of fire or electric shock, do not expose this unit to rain or moisture. The lightning flash with an arrowhead symbol within an equilateral triangle, is intended to alert the user to the presence of uninsulated "dangerous voltage" within the products enclosure that may be of sufficient magnitude to constitute a risk of electric shock to persons. The exclamation point within an equilateral triangle is intended to alert the user to the presence of important operating and maintenance (servicing) instructions in the literature accompanying the product. Important Safety Instructions 1. 2. 3. 4. 5. 6. 7. 8. 9. Please read all instructions before operating the unit. Keep these instructions for future reference. Please heed all safety warnings. Follow manufacturers instructions. Do not use this unit near water or moisture. Clean only with a damp cloth. Do not block any of the ventilation openings. Install in accordance with the manufacturers instructions. Do not install near any heat sources such as radiators, heat registers, stoves, or other apparatus (including amplifiers) that produce heat. Do not defeat the safety purpose of the polarized or grounding-type plug. A polarized plug has two blades with one wider than the other. A grounding type plug has two blades and a third grounding prong. The wide blade or third prong is provided for your safety. When the provided plug does not fit your outlet, consult an electrician for replacement of the obsolete outlet. Protect the power cord from being walked on and pinched, particularly at plugs, convenience receptacles and at the point at which they exit from the unit. Unplug this unit during lightning storms or when unused for long periods of time. Refer all servicing to qualified personnel. Servicing is required when the unit has been damaged in any way, such as power supply cord or plug damage, or if liquid has been spilled or objects have fallen into the unit, the unit has been exposed to rain or moisture, does not operate normally, or has been dropped.
10. 11. 12.
2
Table of Contents
Introduction S gate 4 Features Controls and Functions Front Panel Layout Rear Panel Layout Operating the S gate 4 Setting Up the S gate 4 Gating A Signal Using The Filters Using The Ducker 2 3
45 45
6 7 8 9
Dynamics Processing 101 Applications System Set-ups S gate 4 Connections Block Diagrahm Specifications
1011 12 1314 15 16 1718
Copyright 2001, Samson Technologies Corp. Printed October, 2001 Samson Technologies Corp. 575 Underhill Blvd. P.O. Box 9031 Syosset, NY 11791-9031 Phone: 1-800-3-SAMSON (1-800-372-6766) Fax: 516-364-3888 www.samsontech.com
1
Introduction
Congratulations on your purchase of the Samson S Gate 4! The S Gate 4 is a four channel Expander/Noise Gate with frequency sensitive triggering, offering unparalleled control and sonic transparency impressing the most critical listeners. Never before have so many features been packed into a single rack space unit with four noise gates - period. The S gate 4 is a powerful tool for live sound and recording, enabling you to clean up your mix by eliminating hums, buzzes, noisy tracks and microphone bleed. S Gate 4s DFT (Dual Filter Trigger) enables pinpoint accuracy by letting you control the exact frequency that will open the gate. A full complement of envelope controls including Threshold, Attack, Release, Hold and Range facilitate a wide range of applications from a subtle clean up of a vocal track, to a drastic effect like gating reverb chambers. With proper care and adequate air circulation, your S gate 4 will operate trouble free for many years. We recommend you record your serial number in the space provided below for future reference. Serial number: Date of purchase:
Should your unit ever require servicing, a Return Authorization number (RA) must be obtained before shipping your unit to Samson. Without this number, the unit will not be accepted. Please call Samson at 1-8003SAMSON (1-800-372-6766) for a Return Authorization number prior to shipping your unit. Please retain the original packing materials and if possible, return the unit in the original carton and packing materials.
2
S gate 4 Features
CH 1
HIGH GAIN REDUCTION dB 30 24 18 12 6 4 2 1 LINK
CH 2
HIGH
GAIN REDUCTION dB 30 24 18 12 6 4 2 1
CH 3
HIGH
GAIN REDUCTION dB 30 24 18 12 6 4 2 1
LINK
CH 4
HIGH
GAIN REDUCTION dB 30 24 18 12 6 4 2 1
POWER
TRIGGER
+4 20
ATTACK
.25
HOLD
1
RELEASE
1
RANGE 40
IN/OUT
TRIGGER
+4 20
ATTACK
.5
HOLD
1
RELEASE
1
RANGE 40
.1
TRIGGER
+4 20
ATTACK
.5
HOLD
1
RELEASE
1
RANGE 40
IN/OUT
TRIGGER
+4 20
ATTACK
.5
HOLD
1
RELEASE
1
RANGE 40
4 CHANNEL GATE
.1
KHz 10
.1
KHz 10
KHz 10
.1
KHz 10
-50
dBu +20
.3
mSec
300
.01 Sec
4
.02
Sec
5
1
dB 80
-50
dBu +20
.3
mSec
300
.01 Sec
4
.02
Sec
5
1
dB
80
-50
dBu +20
.3
mSec
300
.01 Sec
4
.02
Sec
5
1
dB
80
-50
dBu +20
.3
mSec
300
.01 Sec
4
.02
Sec
5
1
dB
80
30
LOW
Hz
3K
30
KEY
KEY LISTEN
DUCKER
IN/OUT
LOW
Hz
3K
30
KEY
KEY LISTEN
DUCKER
LOW
Hz
3K
30
KEY
KEY LISTEN
DUCKER
IN/OUT
LOW
Hz
3K
KEY
KEY LISTEN
DUCKER
The Samson S gate 4 dynamics processor utilizes the latest technology in gain management design. Here are some of its main features:
· · · · · · · · · · · · · · ·
Full featured, four channel Noise Gate with Expander and Ducker on each channel in a singlespace, 19" rack mount unit. Extensive envelope control including Threshold, Attack, Hold and Release control for each channel. DFT (Dual FilterTrigger) for precise and predictable triggering. Range control for Ducking. Three stage Gate Open and Closed LED display. Key input with Key Listen switch on each channel. Eight Segment Gain Reduction Meter. Stereo Link Switch for channels 1 & 2 and 3 & 4. Advanced circuit design, utilizing low noise operational amplifiers and high quality VCAs. Servo balanced inputs and outputs on XLR and 1/4" connectors. High quality 41 position detent pots and backlit switches. Internal Transformer. Heavy-duty construction providing reliable performance session after session, performance after performance. The stylish bead blasted, electric blue anodized front-panel is as easy to read as it is to look at. Three-year extended warranty.
3
S gate 4 Front Panel Layout
1
2
CH 1
HIGH
3
4
GAIN REDUCTION dB 30 27 24 18 12 6 2 1
5
LINK
6
CH 2
HIGH GAIN REDUCTION dB 30 27 24 18 12 6 2 1
CH 3
HIGH
TRIGGER
+4 20
ATTACK
.25
HOLD
1
RELEASE
1
RANGE 40
IN/OUT
TRIGGER
+4 20
ATTACK
.25
HOLD
1
RELEASE
1
RANGE 40
.1
TRIGGE
4 CHANNEL EXPANDER GATE
.1
KHz 10
.1
KHz 10
KHz 10
-50
dBu +20
.3
mSec
300
.07 Sec
4
.02
Sec
5
0
dB 100
-50
dBu +20
.3
mSec
300
.01 Sec
4
.02
Sec
5
0
dB 100
-50
dBu +
30
LOW
Hz
3K
30
KEY
KEY LISTEN
DUCKER
IN/OUT
LOW
Hz
3K
30
KEY
KEY LISTEN
DUCKER
LOW
Hz
3K
12
13
14
15
16
17
18
19
20
21
1
2
3
4 5 6
HIGH FILTER CONTROL - Used to set the upper frequency at which the 12dB cut is applied to the side chain input, covering a range from .1 to 10 KHz. GATE OPEN & CLOSED METER Three segment LED Meter indicating the GATE status. Green when Open, Yellow when approaching threshold and Red when closed. GAIN REDUCTION METER Eight segment LED meter displaying the amount of Gain Reduction when Expander/Gate circuit is activated. CHANNEL 1 IN/OUT SWITCH Activates S gate 4's Channel 1. STEREO LINK SWITCH - When engaged Channel 2 functions are controlled by the settings on Channel 1. CHANNEL 2 CONTROLS - The same knob and switch complement as Channel 1.
7 8
9 10 11 12
13
Rear Panel Layout
A B C D E
CHANNEL 3 CONTROLS - The same knob and switch complement as Channel 1. STEREO LINK SWITCH (3 & 4)-When engaged, channel 4 functions are controlled by the settings on channel 3. CHANNEL 4 CONTROLS - The same knob and switch complement as Channel 1. MAINS POWER SWITCH - When turned on, activates the S gate 4. RACK EARS - Used for mounting into a 19 inch standard rack. (One on each side.) LOW FILTER CONTROL - Used to set the lower frequency at which the 12dB cut is applied to the side chain input, covering a range from 30Hz to 3KHz. TRIGGER Used to set the minimum signal level that the Gate/ Ducker circuit begins to function in a range from 60 to +10 dB.
F
G
KEY
CH 4
KEY
CH 3
S.GATE 4
BALANCED OUTPUT
BALANCED OUTPUT
INPUT
INPUT
A B
If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Diplodocs provides you a fast and easy access to the user manual SAMSON SGATE4. SAMSON offer a product for which we do not have the user manual? Let us know what you are looking for: user guide, owner's manual, online manual, operating instructions, quick start guide, mounting instructions, schematics, service manual, installation instructions, RTFM. Diplodocs allows you to download user manual SAMSON SGATE4, user guide SAMSON SGATE4, instructions SAMSON SGATE4, owner's manual SAMSON SGATE4, online manual SAMSON SGATE4.SAMSON SGATE4, , |
![]() |
Know our Partners | ![]() |
Frequently Asked Questions | ![]() |
Contact Diplodocs team | ![]() |
Last searches Last additions |
![]() |
Sitemap | ![]() |
|||
| Brands starting with A B C D E F G H I J K L M N O P Q R S T U V W X Y Z # | |||||||||||||
|
|
Copyright © 2005 - 2008 - Diplodocs -
All Rights Reserved. Designated trademarks and brands are the property of their respective owners. |