9 562 brands
2 694 000 user's guides


Download your manual, it's FREE! Diplodocs allows you to download several types of document in order to best use your SCOTSMAN CMS1402R : user manual, user guide, instruction manual.
Search a brand
Advanced Search

User manual SCOTSMAN CMS1402R

Diplodocs help download the user guide SCOTSMAN CMS1402R .

Download the complete user guide (727 Ko)





Preview of the first 3 pages of manual

You either have JavaScript turned off or an old version of Adobe Flash Player
Get the latest Flash Player.
Manual abstract: user guide SCOTSMAN CMS1402R

Detailed instructions for use are in the User's Guide.

CMS1402R INTRODUCTION To the owner or user: This service manual is intended to provide you and the maintenance or service technician with the information needed to install, start up, clean, maintain and service this ice system. Table of Contents Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . For the Installer Location & Assembly Stacking ................................ 3 4 7 8 9 10 12 13 15 17 19 20 21 25 2 ..................................... ................................. .................................. .................................. For the Electrician For the Plumber Final Check List Initial Start Up . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Freeze Cycle Operation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Harvest Cycle Operation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Component Description ............................... Cleaning . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Adjustments . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Service Diagnosis ................................. Removal and Replacement . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Parts Lists and Wiring Diagrams are located in the center of this manual, printed on yellow paper. September 1993 Page 1 CMS1402R FOR THE INSTALLER The CMS1402R will fit the following Scotsman ice storage bins: A remote condenser and precharged tubing kit are required to assemble this ice system. The normal finish for the machine is enamel sandalwood. An optional stainless steel panel kit (SPKCMS48) can be field installed. It contains a stainless steel top, left side panel, an overlay right side panel, and front panels. · BH900 · BH1000 (with bin top KBT21) · BH1360 and it will stack (with kits)onto the following ice machines: · CMS1402B (with stacking kit KSCMS48) · CMS1202B (with stacking kit KSCMS48) Scotsman Ice Systems are designed and manufactured with the highest regard for safety and performance. They meet or exceed the standards of U.L., N.S.F., and C.S.A. Scotsman assumes no liability or responsibility of any kind for products manufactured by Scotsman that have been altered in any way, including the use of any parts and/or other components not specifically approved by Scotsman. Scotsman reserves the right to make design changes and/or improvements at any time. Specifications and designs are subject to change without notice. Model Number Dimensions (without bin) W" x D" x H" CMS1402RE-3B 48 x 243/8 x 271/2 Basic Electrical Refrigerant Minimum Maximum Refrigerant Condenser Charge** Type Fuse Type Circuit R-22 Ampacity* Size 20.5 31.4 30 30 256 oz. 256 oz. Remote Air Remote Air 208-230/60/3 R-22 208-230/60/1 R-22 CMS1402RE-32B 48 x 243/8 x 271/2 * Minimum Circuit Ampacity is used to determine wire size and type per the National Electric Code. ** The unit is shipped with the full charge in the receiver. For re-charging purposes, if the nameplate charge is different than this number, go by the nameplate. Use Scotsman remote condenser RC1422. Use precharged tubing kit RT2225 (25') or RT2240 (40"). This ice system (except remote condenser) is designed to be installed indoors, in a controlled environment. MINIMUM Air Temperature Water Temperature Water Pressure Voltage 500F. 400F. 20 psi -5% September 1993 Page 2 MAXIMUM 1000F. 1000F. 80 psi +10% CMS1402R FOR THE INSTALLER: Location & Assembly Location: After uncrating and inspection, the unit is ready for installation. It is important that the machine be installed in a location where it has enough space around it to be accessible for service. Try to avoid hot, dirty and crowded locations. Be sure that the location for the machine is within the envrionmental limitations. Storage Bin: Tip the storage bin on its back, using parts of the carton to protect the exterior finish. Install the legs packed with the BH900. If stacking use a heavy duty leg kit (KLP6). 1. Arrange for proper electric, water and drain. See instructions for the plumber and for the electrician. 2. After mounting the legs position the ice storage bin in the selected location: Note: Allow enough space to the left and back to service the machine. Do NOT push the bin into postion, instead, lift it there. Pushing a bin may damage the legs and leg mounts. Level the bin in both the front to rear and side to side directions by adjusting the leg levelers. 3. Inspect the bin top mounting gasket which should be flat, with no wrinkles, to provide a good water seal when the cuber is installed on top of the bin. Ice Maker: Install the modular cuber on top of the bin using care to be sure a good seal is made between the two cabinets. Use of a mechancial lift is recommended. Align the holes in the bottom rear of the cabinet to mate with the two mounting holes on the top rear of the bin. Use bolts and straps found on the back of the ice machine to secure the ice machine to the bin. When alignment and leveling are completed, tighten the bolts to secure the mounting straps. Remove the front panel, and remove the evaporator shipping brackets and hardware. SHIPPING BRACKETS ICE MACHINE AND BIN ASSEMBLY September 1993 Page 3 CMS1402R FOR THE INSTALLER: Location & Assembly Stacking Instructions A stacking kit, KSCMS48, is required to interconnect the ice level controls, seal the freezing compartments, support the bin with heavy duty legs, and retain the front panels. Follow the installation instructions of the stacking kit, but in general: Replace the original bin legs with heavy duty legs (KLP6). When stacking two units, remove the top panel and the evaporator cover from the lower icemaker. STACKING (The top removed from the lower icemaker will no longer have any function.) Add a strip of gasket (from the stacking kit) to the top edge of the bottom ice machines evaporator compartment. Install the panel retaining bracket onto the bottom ice machine before placing the upper unit on it. Place additional gasket onto the top edges of the bottom ice machine. Carefully lift the uncrated top unit onto the bottom one and align the two cabinets. Use of a mechanical lift is recommended for this step. At the back of the two icemakers, bolt the upper icemaker cabinet to the lower icemaker cabinet using the mounting straps and bolts from the hardware package. Add the relay kit to interconnect the two ice machine's bin control circuits. STAINLESS STEEL PANEL RETAINING BRACKET EVAPORATOR COVER September 1993 Page 4 CMS1402R FOR THE INSTALLER: Scotsman Remote Condenser Locate the condenser as near as possible to the interior location of the ice maker. Location of the condenser is limited by the specific length of precharged refrigerant tubing supplied for the application. The pre-charged tubing connects the icemaker to the remote condenser. The condenser must be above the ice maker. Select the best available location, protecting the condenser from extremes of dirt, dust, and sun. Meet all applicable building codes. Roof Attachment: Install and attach the remote condenser unit to the roof of the building, using the methods and practices of construction that conform to the local building codes, including having a roofing contractor secure the condenser to the roof. Precharged Line Routing /////////////////////////////CAUTION/////////////////////////////// Do not connect precharged tubing until all routing and forming of the tubing is complete. See the coupling instructions for connecting instructions. //////////////////////////////////////////////////////////////////////////// 1. Each set of precharged refrigerant lines consists of a 3/8 inch diameter liquid line, and a 1/2 inch diameter discharge line. Both ends of each line have quick connect couplings, the end without access valves goes to the icemaker. Note: The openings in the building ceiling or wall, listed in the next step, are the minimum sizes recommended for passing the refrigerant lines through. 2. Have the roofing contractor cut a minimum hole for the refrigerant lines of 1.75". Check local codes, a separate hole may be required for the electrical power to the condenser. /////////////////////////////CAUTION////////////////////////// ////// DO NOT KINK OR CRIMP REFRIGERANT TUBING WHEN INSTALLING IT. //////////////////////////////////////////////////////////////////////// //// REFRIGERANT CONNECTIONS 3. Route the refrigerant lines through the roof opening. Follow straight line routing whenever possible. Any excess tubing MUST be retained within the building. 4. Spiral any excess length of pre charged tubing inside the building. Use a horizontal spiral to avoid any traps in the lines. 5. Have the roofing contractor seal the holes in the roof per local codes. LOCATE CONDENSER NO LOWER THAN ICE MACHINE TYPICAL INSTALLATION September 1993 Page 5 CMS1402R FOR THE INSTALLER: Coupling Instructions ////////////////////////////////CAUTION///////////////////////////////// The couplings on the sets of precharged lines are self sealing when installed properly. Carefully follow the instructions: //////////////////////////////////////////////////////////////////////////////// Initial Connections: 1. Remove the protector caps and plugs. Wipe the seats and threaded surfaces with a clean cloth to be certain that no foreign matter remains on them. 2. Lubricate the inside of the couplings, especially the O-Rings with refrigerant oil. · The 1/2 inch discharge line (schrader valve end) goes to the remote condenser fitting marked "discharge line". · The 3/8 inch liquid line (schrader valve end) goes to the remote condenser fitting marked "liquid line". Final Connections: 3. Begin tightening the couplings together by hand, then using two wrenches (it is important that ONLY the nut on the precharged lines be turned, the other parts of the couplings must NOT be allowed to turn or the process will tear out the diaphragms and they will be loose in the refrigeration system) tighten the coupling until it bottoms out or a definite increase in resistance is felt. TIGHTENING THE QUICK CONNECTS SCHRADER VALVES 4. Using a marker or pen, mark a line lengthwise from the coupling union nut to the bulkhead. Then tighten the coupling and additional 1/4 turn. As the nut turns, the line will show when 1/4 turn is made. 5. After all connections are made, and after the king valve has been opened, check the couplings for leaks. · The 1/2 inch discharge line goes to the icemaker fitting marked "discharge line". · The 3/8 inch liquid line goes to the icemaker fitting marked "liquid line." DISCHARGE LINE LIQUID LINE INSULATION September 1993 Page 6 CMS1402R FOR THE ELECTRICIAN SEE NAMEPLATE for current requirements to determine wire size to be used for electrical hookup. When the cuber and the remote condenser are connected, each must be grounded to the other using the ground screws provided in the respective junction boxes. The cuber then requires a solid chassis to chassis earth ground wire. See Wiring Diagram. Be certain the cuber is connected to its own electrical circuit and individually fused. Voltage variation should not exceed ten percent of the nameplate rating, even under starting conditions. Low voltages can cause erratic operation and may be responsible for serious damage to the icemaker. The Scotsman remote condenser is designed to be powered from the ice machine. There is a separate electrical junction box at the back of the ice maker for the remote condenser. Wire the remote condenser to the ice maker in accordance with local and national electric codes. All outdoor wiring must be in rainproof conduit. The condenser fan motor will run whenever the compressor is running. Electrical connections are made at the rear of the icemaker, inside the junction box. All external wiring should conform to the national, state and local electrical code requirements. Usually an electrical permit and services of a licensed electrician will be required. ELECTRICAL CONNECTIONS GROUND SCREW HAND DISCONNECT SWITCH DETAIL OF JUNCTION BOX, 3 PHASE SHOWN POWER SUPPLY INTERCONNECTING WIRES REMOTE CONNECTION September 1993 Page 7 CMS1402R FOR THE PLUMBER The recommended water supply line is a 3/8-inch O.D. copper tubing with a minimum operating pressure of 20 PSIG and a maximum of 80 PSIG. Connect to cold water supply line with standard plumbing fittings, with shut off valve installed in an accessible place between the water supply and the cuber. ln some cases a plumber will be required. Water Limitations: An ice machine is a food manufacturing plant, it takes in a raw material, water, and turns it into a food product, ice. The purity of the water is very important in obtaining pure ice and in maximizing product life. It is generally better to filter the water, although there is no one filter that ...

  Know our Partners   Frequently Asked Questions   Contact Diplodocs team   Last searches
Latest additions
  Sitemap
Brands starting with A B C D E F G H I J K L M N O P Q R S T U V W X Y Z #
Copyright © 2005 - 2008 - Diplodocs - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.