9 562 brands
2 694 000 user's guides


Download your manual, it's FREE! Diplodocs allows you to download several types of document in order to best use your SCOTSMAN FM1200 : user manual, user guide, instruction manual.
Search a brand
Advanced Search

Need help using a product?
Look at the reviews on SCOTSMAN FM1200

User manual SCOTSMAN FM1200

Diplodocs help download the user guide SCOTSMAN FM1200 .

Download the complete user guide (961 Ko)





Preview of the first 3 pages of manual

You either have JavaScript turned off or an old version of Adobe Flash Player
Get the latest Flash Player.
Manual abstract: user guide SCOTSMAN FM1200

Detailed instructions for use are in the User's Guide.

FM1200 INTRODUCTION To the owner or user: The service manual you are reading is intended to provide you, and the maintenance or service technician, with the information needed to install, start up, clean, maintain, and service this ice system. The FM1200 is a modular ice system that fits a variety of Scotsman ice storage bins. It features: front service for the freezer, gearmotor, control box, water reservoir, and bin control; an electronic circuit for monitoring ice and water level; a thermostatic expansion valve; and R-502 as the refrigerant. TABLE OF CONTENTS Installation For the Installer Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2 Location . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4 Two units on one bin ...............................5 For the Plumber . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6 For the Electrician . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7 Final Check List . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8 Start Up ...........................................9 Component Description . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10 Electrical Sequence . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13 Operation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14 Maintenance and Cleaning . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 16 Service Diagnosis . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 20 Removal and Replacement Reservoir and Bin Controls . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 24 Bearing and Breaker . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 25 Auger . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 26 Water Seal Evaporator . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 27 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 28 Gearmotor . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 29 Fan Motor Assembly . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 30 Electronic Tester . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 31 Parts lists and wiring diagrams are in the center of this manual, printed on yellow paper. October, 1991 Page 1 FM1200 FOR THE INSTALLER BACK VIEW: AIR COOLED Note: Allow 6" behind and 6" above either unit for air circulation, utility connections, and service. ELECTRICAL INLET BACK VIEW: WATER COOLED ELECTRICAL INLET WATER INLET 9.5" 5.25" 3" 5.25" 3" 7.3" 9.43" WATER INLET 3/8" FLARE DRAIN 3/4" FPT Condenser Inlet 3/8" FPT 2.1" 5.7" 2.9" Condenser Drain 1/2" FPT 3.4" DRAIN 3/4" FPT 4.9" 7.46" The FM1200 is designed to fit the following Scotsman storage bins: B590 and extensions (with bin top KBT18) BH800 using bin top KBT15 (one unit). BH800 (two units, no bin top required). BH1000 using bin top KBT16. When installing a new system, check to be sure that you have everything you need before beginning: Correct Bin Correct Ice Machine Correct Bin Top (if required) All kits, legs, and information required for the specific job. SPECIFICATIONS: ICE MAKER Model Number Dimensions (w/o bin) HXWXD 27" x 21" x 24" same same same Basic Electrical 208-230/60/3 same 208-230/60/1 same Installation Limitations: This ice system is designed to be installed indoors, in a controlled environment: Min Max 0 Air Temperature 50 F 1000F Water Temperature 400F 1000F Water Pressure 20 PSI 80 PSI Voltage -5% +10% (Compared to the nameplate) Operating the machine outside of the limitations is misuse and can void the warranty. The normal finish for the ice machine is enamel-sandalwood. A stainless steel panel kit, SPKFM21 may be field installed to convert the unit to a stainless steel finish. Ice Type Condenser Type Air Water Air Water Minimum Circuit Ampacity 13.4 12.9 14.6 14 Max Fuse Size 20 20 20 20 Comp. H.P. 1.5 1.5 1.5 1.5 FM1200AE-3A FM1200WE-3A FM1200AE-32A FM1200WE-32A FLAKE same same same Note: Minimum Circuit Ampacity is used to determine wire size and type per national electric code. October, 1991 Page 2 FM1200 FOR THE INSTALLER B590 33" 30.5" 42.25" 21.12" 32" 6" 4.88" 22.38" 4" 32.5" Scotsman Ice Systems are designed and manufactured with the highest regard for safety and performance. They meet or exceed the standards of UL, NSF, and CSA. Scotsman assumes no liability or responsibility of any kind for products manufactured by Scotsman that have been altered in any way, including the use of any part and/or other components not specifically approved by Scotsman. Scotsman reserves the right to make design changes and/or improvements at any time. Specifications and design are subject to change without notice. 1.25" 21.12" Drain 3/4" FPT MODEL DIMENSIONS H" x W" x D" 32 x 42.5 x 30.5 same STORAGE CAPACITY 590 lbs. same FINISH B590E B590S Enamel Stainless Steel October, 1991 Page 3 FM1200 FOR THE INSTALLER Location: Typical Storage Bin with Extension and Bin Top After uncrating and inspection, the unit is ready for installation. It is important that the machine be installed in a location where it has enough space around it to be accessible for service, and minimum of 6" be allowed at the back for air circulation on air cooled models. Try to avoid hot, dirty and crowded locations. Be sure that the location for the machine is within the environmental limitations. Storage Bin: Tip the storage bin on its back, using parts of the carton to protect the exterior finish. Install the legs into the threaded holes in the bottom of the bin. Turn the leg levelers all the way in preparation for leveling later. Return the bin to the upright position, remove paper covering the bin gasket. Note: Do not push bin into position, but lift it there. Pushing a bin, especially one with ice in it, can cause damage to the legs and the leg mounts. Install the appropriate bin top on the bin, according to the instructions for the bin top. Ice Maker: The machine is heavy, so the use of a mechanical lift is recommended for lifting the machine high enough to install on top of the bin. After the unit is placed on the bin, line it up so it is even with the back side. Secure the machine to the bin with the hardware provided with the machine. Remove the front panel and remove any shipping blocks. October, 1991 Page 4 FM1200 FOR THE INSTALLER: Location TWO UNITS ON ONE BIN DO NOT STACK ANYTHING IN FRONT OF THE MACHINE(S) ALLOW ROOM FOR AIR CIRCULATION AND SERVICE ACCESS October, 1991 Page 5 FM1200 FOR THE PLUMBER CONFORM TO ALL APPLICABLE CODES Water Inlet Air Cooled Models: The recommended water supply is clean, cold water. Use 3/8" O.D. copper tubing, connect to the 3/8" male flare at the back of the cabinet. Install a hand valve near the machine to control the water supply. Water Treatment: In most areas, a water filter of some type will be useful. In areas where the water is highly concentrated with minerals the water should be tested by a water treatment specialist, and the recommendations of the specialist regarding filtration and/or treatment should be followed. Water Cooled Models: A separate 3/8" O.D. copper line is recommended, with a separate hand valve to control it. It is connected to a 3/8" FPT condenser inlet at the back of the cabinet. The water pressure to all lines must always be above 20 psig, and below 120 psig. WATER COOLED CONDENSER INLET HAND VALVE Drains Air Cooled Models: There is one 3/4" FPT drain at the back of the cabinet, the drain line is of the gravity type, and 1/4 inch per foot fall is an acceptable pitch for the drain tubing. There should be a vent at the highest point of the drain line, and the ideal drain receptacle would be a trapped and vented floor drain. Use only 3/4" rigid tubing. Water Cooled Models: In addition to the above mentioned drain, a separate condenser drain must be installed. Connect it to the 1/2" condenser drain connection at the back of the cabinet. Storage Bin: A separate gravity type drain needs to be run, similar to the air cooled drain. Insulation of this drain line is recommended. AIR COOLED MODELS FIELD SUPPLIED FILTER VENTED DRAIN HAND VALVE WATER FILTER CONDENSER DRAIN VENTED DRAIN WATER INLET October, 1991 Page 6 FM1200 FOR THE ELECTRICIAN CONFORM TO ALL APPLICABLE CODES The electrical power to the unit is supplied through the junction box at the rear of the machine. Check the nameplate (located on the back panel) for the voltage requirements, and for the minimum circuit ampacity. The machine requires a solid chassis to earth ground wire. The ice maker should be connected to its own electrical circuit so it would be individually WATER COOLED fused. Voltage variation must remain within design limitations, even under starting conditions. All external wiring must conform to national, state, and local electrical codes. The use of a licensed electrician is required to perform the electrical installation. POWER SUPPLY AIR COOLED October, 1991 Page 7 FM1200 FOR THE INSTALLER Final Check List 1. Is the ice system installed indoors in a location where the air and water temperatures are controlled, and where they do not exceed the design limitations? 2. Is there an electrical service disconnect within sight of the installed machine? Has the voltage been checked, and compared to nameplate requirements? 3. Have all the plumbing connections been made and checked for leaks? 4. Has the machine and bin been leveled? 5. Is there a minimum of 6" clearance at the back of the machine for proper service access and air circulation? 6. Is the water pressure a minimum of 20 psig? 7. Has the machine been secured to the bin? 8. Is there clearance over the top of the machine for service access? 9. Is there a water shut off valve installed near the machine? 10. Have all of the shipping blocks been removed? October, 1991 Page 8 FM1200 START UP Pre-Start Inspection 1. Remove the front and side service panels. 2. Check that the styrofoam shipping blocks have been removed. 3. Inspect the interior of the machine for loose screws or wires. Check that no refrigerant lines are rubbing each other. Check that the fan blade turns freely (air cooled). 4. Check that the unit is installed correctly according to the final check list (page 8). Start Up 1. Go through the prestart inspection. 2. Open the hand valve, observe that water enters the water reservoir, fills the tube from the reservoir to the evaporator, and then shuts off. Check for leaks. 3. Switch the master switch on. The electrical start up sequence is now on automatic. A. There should be a short (15 second) delay before the gearmotor starts. B. After the gearmotor starts, the compressor will start. 4. On air cooled models, the condenser will begin to discharge warm air, on water cooled models, the water regulating valve will open, and warm water will be discharged into the drain. 5. The unit should soon be making ice, if desired, the low side pressure can be checked: it should be 30 psig + or - 4 psig. The suction line temperature at the compressor is normally very cold, nearly to the point of frost up to the compressor body, but not on it. The air cooled discharge pressure will depend upon air and water temperatures, but should be between 200 psig and 280 psig. The water cooled discharge pressure should be constant at about 220 psig. The above numbers are for new, clean machines, you can expect to see some values higher, and some lower between different units. 6. THERE ARE NO ADJUSTMENTS TO MAKE, so replace the panels. 7. Clean and/or sanitize the storage bin interior, wipe off the exterior with a clean, damp cloth. 8. Give the owner/user the service manual, instruct him/her in the operation of the unit, and make sure they know who to call for service. 9. Fill out the manufacturers registration card, and mail it to the Scotsman Factory. 10. Fill out the field quality audit form, and mail it to the Scotsman factory. October, 1991 Page 9 FM1200 COMPONENT DESCRIPTION Control Box: Contains the electrical controls that operate the machine. High Pressure Cut Out Switch: A manual reset switch sensing the high side refrigeration pressure. It is set to shut the machine off, and illuminate the reset switch light if the discharge pressure should ever exceed 450 psig. Reset Switch: A manual reset switch, used for restarting the ice machine should the ice discharge chute overfill with ice; the low pressure cut out switch open; or the high pressure cut out switch open. Evaporator: A vertical stainless steel tube, refrigerated, and water filled. In it there is a stainless steel auger. Compressor: The refrigerant vapor pump. Reservoir: Float operated, it maintains the wate ...

  Know our Partners   Frequently Asked Questions   Contact Diplodocs team   Last searches
Latest additions
  Sitemap
Brands starting with A B C D E F G H I J K L M N O P Q R S T U V W X Y Z #
Copyright © 2005 - 2008 - Diplodocs - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.