Detailed instructions for use are in the User's Guide.
Single System RL
TO THE OWNER OR USER:
The service manual you are reading is intended to provide you, and the maintenance or service technician, with the information needed to install, start up, clean, maintain and service this ice system. This Remote Low side unit is the freezer portion of a commercial ice machine. It is designed to be connected to the condensing section of a refrigeration system, specifically a supermarket R-404A system.
Table of Contents
FOR THE INSTALLER: Specifications FOR THE INSTALLER ........................... Page 2 Page 3 Page 4 Page 5 Page 6 Page 7 Page 8 Page 9 Page 10 Page 11 Page 12 Page 13 Page 14 Page 15 Page 16 Page 18 Page 19 Page 20 Page 21 Page 22 Page 23 Page 24 ...................................
FOR THE ELECTRICIAN . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . FOR THE PLUMBER . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . FOR THE INSTALLER: Final Check List Initial Start Up COMPONENT DESCRIPTION: Control Box .................. COMPONENT IDENTIFICATION . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ........................ COMPONENT DESCRIPTION: Evaporator . . . . . . . . . . . . . . . . . . . . . . . . . ELECTRICAL SEQUENCE . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . OPERATION ........................................ ............................. OPERATION: Refrigeration . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . MAINTENANCE AND CLEANING CLEANING MAINTENANCE . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ........................................ ................ ............................. ............................. ............................. SERVICE DIAGNOSIS: Condition - No Ice Being Produced REMOVAL AND REPLACEMENT REMOVAL AND REPLACEMENT REMOVAL AND REPLACEMENT
REMOVAL AND REPLACEMENT: Bearing And Breaker . . . . . . . . . . . . . . . . . .
REMOVAL AND REPLACEMENT: Evaporator . . . . . . . . . . . . . . . . . . . . . . . REMOVAL AND REPLACEMENT: Gearmotor . . . . . . . . . . . . . . . . . . . . . . . CIRCUIT BOARD TESTING ................................
Parts lists and wiring diagrams are in the center of this manual, printed on yellow paper.
This manual was printed on recycled paper. Keep it for future reference. Note the Warning symbol where it appears. It marks a potential hazard.
January 1997 Page 1
Single System RL
FOR THE INSTALLER: Specifications
The unit is designed to fit a variety of Scotsman storage bins. See sales literature for more information. Installation Limitations: The remote low side is designed for indoor installations only. The machine must also be in a controlled environment where the air temperature does not fall below 500F., or go above 1000F. The water temperature must be between 400F. and 1000F. The electrical power supply must not drop below -5% of the lowest nameplate voltage or go above 10% of the highest nameplate voltage. SPECIFICATIONS:
Scotsman Ice Systems are designed and manufactured with the highest regard for safety and performance. They meet or exceed the standards of U.L., N.S.F., and C.U.L. Scotsman assumes no liability or responsibility of any kind for products manufactured by Scotsman that have been altered in any way, including the use of any parts and/or other components not specifically approved by Scotsman. Scotsman reserves the right to make design changes and/or improvements at any time. Specifications and designs are subject to change without notice.
Model FME1200RL NME950RL FM1202RL NM952RL FME1500RL NME1250RL
Cabinet Size 21"w x 27"h x 24"d 21"w x 27"h x 24"d 21"w x 27"h x 24"d 21"w x 27"h x 24"d 21"w x 27"h x 24"d 21"w x 27"h x 24"d
System Refrigerant R-404A R-404A R-22 R-22 R-404A R-404A
BTUH required 8,000 8,000 8,000 8,000 8,000 8,000
Voltage 208-230 208-230 208-230 208-230 208-230 208-230
Ice Type Flaker Nugget Flaker Nugget Flaker Nugget
January 1997 Page 2
Single System RL
FOR THE INSTALLER
Select the Location: The unit can only be installed indoors within the limitations described on page 2. The ice machine will have to be connected to the building's refrigeration system, check to be sure that the system has enough extra capacity to handle a minimum of additional 8,000 BTU's per hour @ 1100F. liquid line temperature (assume a 00F. evaporator temperature). Storage Bin: Using a mechanical lift, install the ice machine onto the top of the storage bin. Fasten the ice machine to the bin using (4) 5/15-18 2.5" cap screws. Level the assembly by: a. Turning the leg levelers in or out on the standard legs. b. Use shims under the heavy duty legs of the KLP4. Locate the Nameplate: The nameplate is located on the back panel of the machine, and contains the electrical characteristics particular to the unit being installed. Refrigeration Installation: The skills of a refrigeration technician are required to connect the ice machine to the buildings refrigeration system. Notes: ·Suction Line and Liquid Line Stubs are at the back of the cabinet.
TYPICAL INSTALLATION: ALLOW ROOM FOR SERVICE ACCESS
FME1200RL
BX87 BIN EXTENSION B90 STORAGE BIN
·1.5 ounces of the appropriate
refrigerant is in the system as a holding charge.
·Be sure there is enough BTU capacity. ·Be sure that the liquid connection is NOT in
series with another liquid line valve.
·Local Codes must be observed. ·A P-trap should be installed where there will be
more than 10' of vertical rise in the suction line.
January 1997 Page 3
Single System RL
FOR THE ELECTRICIAN
CONFORM TO ALL APPLICABLE CODES
Electrical Connections: Locate the nameplate for the current requirements, and then determine the wire size and type per the National Electric Code. The machine requires a solid chassis to earth ground wire. Refer to the wiring diagram. The ice machine should be connected to it's own electrical circuit, and be individually fused. Voltage, when the unit is under full load, must remain within the limitations listed on page 2. LOW VOLTAGE CAN CAUSE EQUIPMENT MALFUNCTION AND/OR DAMAGE All external wiring should conform to the National, State, and local electrical codes. Usually the services of a licensed electrician will be required.
DETAIL OF JUNCTION BOX
JUNCTION BOX POWER SUPPLY
January 1997 Page 4
Single System RL
FOR THE PLUMBER
CONFORM TO ALL APPLICABLE CODES
Water Supply: The recommended water supply line is 3/8" O.D. copper tubing, with a minimum operation pressure of 20 PSIG, and a maximum of 80 PSIG. Connect to cold water using the male flare connection at the back of the machine. Install a shut off valve in an accessible space between the ice maker and the water supply. Drain System: All drains are of the gravity type, and must have a minimum of 1/4" fall per foot of horizontal run. The drains must be installed to conform to local plumbing codes. The use of a vent at the machine and at the bin will allow the system to drain properly. Use only rigid tubing for drains; insulation of the bin drain is recommended.
3/8" MALE FLARE
3/4" FPT SHUT OFF VALVE
VENT THIS DRAIN
FIELD SUPPLIED WATER FILTER
WATER INLET
BIN DRAIN
FLOOR DRAIN January 1997 Page 5
Single System RL
FOR THE INSTALLER:
Final Check List 1. Is the unit installed where the air and water temperatures are within and will remain within the limitations for the unit? 2. Is there 6" clearance at the rear of the machine for utility connections? 3. Has the water supply line be checked for pressures between 20 and 80? 4. Has the unit been leveled? 5. Has the shipping material been removed from inside the cabinet? 6. Have the electrical connections been made? 7. Have the drains been installed and checked for leaks? 8. Has the refrigeration supply been installed and checked for leaks? 9. Has the bin and cabinet been wiped clean or sanitized? 10. Has the warranty registration card been properly filled out and mailed to Scotsman? 11. Has the owner been given the service manual and been instructed on how to maintain the ice maker? 13. Has the owner been given the name and telephone number of the local Scotsman service agency? Initial Start Up 1. Remove the top and front panels. 2. Open the water valve, and observe that the two float reservoirs fill up with water and shut off. 3. Switch on the electrical power. 4. Open the hand valve (in the liquid line). 5. Open the ball valve (in the suction line). 6. Switch on the master switch, and observe: The liquid line valve opens The gearmotor runs Within a short time, that side of the machine begins to make ice. Water flows from the water reservoir, and the float drops, letting in more water. 7. When operating, the sight glass should remain full, and the low side pressure will be about: RLE1202/952 - 25 PSIG + or - 2 PSIG RLE1200/950 - 36 PSIG + or - 2 PSIG RLE1500/1250 - 25 PSIG + or - 2 PSIG Gearmotor amp draw should not exceed the nameplate rating. 8. Check the system very carefully for any refrigerant leaks, repair as needed.
November 1999 Page 6
Single System RL
COMPONENT IDENTIFICATION
Liquid line valve This valve operates to turn the ice making process on and off. When the ice level drops in the ice chute, the ice level sensor will cause the circuit board to close the liquid line relay, which energizes the liquid line valve. The liquid line valve opens, and liquid refrigerant flows to the thermostatic expansion valve. Thermostatic Expansion Valve The metering device of the system, the valve senses the temperature of the suction line and varies the amount of liquid refrigerant that passes through the valve into the evaporator, thus maintaining a constant level of refrigeration. TXV's are factory set. Do not adjust unnecessarily. DO NOT ADJUST THE TXV UNTIL THE EPR HAS BEEN SET. The superheat setting is 4-80F. Measure the temperature of the evaporator outlet at the TXV bulb, and check the low side pressure at the EPR valve. Convert the pressure to temperature (using a temperature pressure chart) and subtract the amount from the outlet temperature. The result is the superheat. Use an electronic thermometer. EPR: Evaporator Pressure Regulator Valve This valve maintains a constant pressure on its inlet (evaporator) side regardless of the pressure on the outlet (suction) side. The EPR is factory set, adjust only if needed. After adjusting, re-check TXV superheat. EPR Settings: RLE1202/952: 25 PSIG + or - 2 PSIG RLE1200/950: 36 PSIG + or - 2 PSIG RLE1500/1250: 25 PSIG + or - 2 PSIG Evaporator: Where the water is frozen into ice crystals. As the water cools, it begins to turn into ice, and the slowly turning auger lifts the ice, as it is being made, and forces it up and out of the "breaker" or spout where the extra water is compressed out of the ice. The ice then drops through the chute, into the storage bin.
EPR VALVE THERMO VALVE
LIQUID LINE VALVE
November 1999 Page 7
Single System RL
COMPONENT DESCRIPTION: Control Box
Circuit Board: Controlling the ice machine through sensors and relays. The sensors are: ice level, and water level. The relays are for the gear motor (with a built in time delay to clear the evaporator of ice when the unit turns off) and for the liquid line valve. Transformer: Supplies low voltage to the circuit board. On/Off Switch: Manual control for that side of the machine.
ON/OFF SWITCH
TERMINAL STRIP
TRANSFORMER
CIRCUIT BOARD
January 1997 Page 8
Single System RL
COMPONENT DESCRIPTION: Evaporator
Evaporator: A refrigerated vertical tube filled water and containing a water seal and auger. Auger: A solid stainless steel double spiral auger, it pushes the ice crystals up to the top of the evaporator. Water Seal: A two part "face" seal, the top half rotating with the auger, the bottom half stationary, the sealing action being where the two seal "faces" meet. Ice Sweep: A plastic cap with "fingers". It revolves with the auger to "sweep" the ice into the ice chute. Divider: Where the ice is compressed and much of the extra water is squeezed out of it before it is discharged into the bin. Motor: A split phase motor that drives the gear reducer. Bearing: As the ice is pushed up the evaporator, the auger is thrust down, and pressure from the auger thrust is taken up by this bearing.
BEARING
ICE SWEEP
DIVIDER EVAPORATOR
AUGER
WATER SEAL
MOTOR
January 1997 Page 9
Single System RL
ELECTRICAL SEQUENCE
Refer the wiring diagram as needed. Each system is separate If the machine is switched off at the master switch, but is otherwise ready to go, switching the master switch to on does the following: ·The bin empty light on the circuit board goes on Shut Down consists of: ·The liquid line relay opens.
·The liquid line valve closes ·Ice making stops ·The auger motor is run by the circuit board for 2
more minutes, clearing out ice in the evaporator, and then
·There is a 15 second delay ·If there is enough water in the reservoir, the
circuit board will allow the machine to start up. Start up consists of: ...