Detailed instructions for use are in the User's Guide. THE SYSTEM
OPERATING MANUAL
®
English
Digital Pressure Gauge
SWISS MADE BY UWATEC AG
English
2
Uwatec® Digital Pressure Gauge
Attention!
This Digital Pressure Gauge is according to EN 250 a piece of safety equipment of a SCUBA. It may only be completed to a complete SCUBA with components, which passed the EU-Certification and come up to the EN 250 norm. According to the EN 250 a complete SCUBA consists at least of the following components: a) b) c) d) e) f) g) Air pressure tank(s) and tank valve(s) Regulator Safety equipment Frame or holding device for air cylinder(s) with the possibility to mount the harness Carrier device Breathing connection (face mask and mouthpiece, full face mask, or diving helmet) Instructions for use must be included
English
The high-pressure hose of the Digital Pressure Gauge is equipped at its connection (7/16") with a flow through reduction. According the law of technical working devises we point to the following points: · Base of each use of the Digital Pressure Gauge and its component parts is the knowledge and consideration of this Manual. · The Digital Pressure Gauge may only be used for the purposes mentioned in this manual or confirmed in writing by Uwatec. · The Digital Pressure Gauge has to be yearly inspected (inspection-maintenance-reparation) by an educated authorised person. These inspections have to be recorded. Only original Uwatec spare parts may be used for replacements. · The EN 250 Certification maximum depth is 50 m.
Uwatec® Digital Pressure Gauge
3
Important remarks concerning words and symbols
This operating manual makes use of the following icons to indicate especially important comments: Remarks: Information and tips which are important for optimal use of your the Digital Pressure Gauge. Indicates information about specialities which are important to prevent a risky situation and to dive more comfortably.
Attention!
Danger!
Indicates a potentially hazardous situation which, if not avoided, could result in death or serious injury. Acoustical confirmation (short beep) Acoustical Alarm Overview over the chapter Flashing part of the display Details of the chapter How to get into the actual part of the program How to leave the actual part of the program
Uwatec® Digital Pressure Gauge
The following symbols are used in the operating manual: LCD display samples
E S B P > 8 bar
Operating instruction for Manual input (Example: bridging contacts B and E). Tank pressure higher than 8 bar.
4
List of chapters
Introduction / Overview . . . . . . . . . . . . . . . . . .6 Safety considerations / Warnings . . . . . . . . . . . .7 Set Up Procedure Switching the unit on and off . . . . . . . . . . . . . .9 Before the first dive . . . . . . . . . . . . . . . . . . . .10 User Mode / . . . . . . . . . . . . . . . . . . . .10 ·Set Up the tank pressure alarm . . . . . . . . .11 ·Set Up pressure and temperature unit . . . .13 Mounting the high-pressure hose to the first stage . . . . . . . . . . . . . . . . . . . . . . . . . . .14 Connecting the Digital Pressure Gauge . . . . . .14 Disconnecting the Digital Pressure Gauge . . . .16 Measurement Mode . . . Tank Pressure Alarm Preparation for the Dive Logbook ........ . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .17 .18 .19 .19 .20 .21 .22 .23 Warranty . . . . . . . . . . . . . . . . . . . . . . . . . . . .24 EC type-approval . . . . . . . . . . . . . . . . . . . . . .25 Overview user interface . . . . . . . . . . . . . . .26, 27 Serial No. / Dealer address . . . . . . . . . . . . . . .28
English
Battery Warning .. Maintenance and Storing Trouble Shooting . . . . . . Technical Information . . .
Uwatec® Digital Pressure Gauge
5
Introduction / Overview
The Uwatec Digital Pressure Gauge measures the tank pressure and displays it together with the ambient temperature on the display. A high-pressure hose connects the Digital Pressure Gauge on the first stage of the diving tank. The Digital Pressure Gauge has two pressure alarm values. One is fixed at 50 bar, the other one can be set by the user between 30 and 100 bar (450-1500 psi). The Digital Pressure Gauge warns the diver optically and acoustically if the tank pressure falls short off one of these pressure alarm values. Furthermore the diver can select the units for the pressure and temperature indication. The logbook stores the original and the final tank pressure of a given dive and displays the pressure difference.
Symbols: Logbook, Set Up, Maintenance, Battery warning Contact E Contact S Tank pressure (graphically) Tank pressure alarm symbol Contact B Tank pressure (bar, psi) Temperature (°C, °F) Overpressure valve
6
Uwatec® Digital Pressure Gauge
Safety considerations / Warnings
Do not use the Digital Pressure Gauge, until you have carefully read all instructions and safety precautions found in this manual. Diving has many inherent risks. Even if you follow the instructions of this manual, it is still possible that you may not have enough air until the end of the dive. Unless you are fully aware of the risks and are willing to personally accept responsibility for those risks, do not use the Digital Pressure Gauge! · The Digital Pressure Gauge may only be used together with compressed air. Do not use it for oxygen enriched gases. · The Digital Pressure Gauge does not give any warning about a too low air reserve. Check frequently your tank pressure! · Do not use on cylinders charged above the maximum working pressure. See "Technical Information" page 23. · The Pressure Gauge may only be used if it is in working condition. · If your diving cylinder is equipped with a reserve or ,,J"-type valve, make certain that the reserve function is in an open position for the Digital Pressure Gauge works correctly. · Rubber boot and console must not cover the overpressure valve, enabling air to leave without resistance. (Hole diameter 6 mm)
Uwatec® Digital Pressure Gauge
7
English
Safety considerations / Warnings
· There is a danger of insufficient air supply if air leaves the over pressure valve or another part of the measurement system. Start ascent immediately! · The Pressure Gauge should be secured in a way that will not cause the unit to be caught or snagged whilst diving. · If the maintenance symbol appears, do not continue diving with the Digital Pressure Gauge anymore. If the symbol appears during a dive: start ascending immediately! If the maintenance symbol appears, the display may be blocked without further warning. Take the unit to your authorised Uwatec Dealer for battery exchange. · If ,,CAL" appears, you must not dive with the Digital Pressure Gauge any more. If the symbol appears during a dive: start ascending immediately! The display is blocked. Have the unit repaired. · If the Digital Pressure Gauge fails at any time during the dive, the dive must be terminated except when a second pressure gauge is available. · Retain this manual for your reference. · The Digital Pressure Gauge has been exclusively made for sports diving (EN 250). It may only be used together with high-pressure hose with a flow through reduction.
8
Uwatec® Digital Pressure Gauge
Set Up Procedure Switching the unit on and off
The Digital Pressure Gauge can be switched on either by bridging the contacts B and E or if the connected tank pressure exceeds 8 bar.
After switching the unit on by bridging the contacts the display shows for a short time all segments and goes into the User Mode, which can be run through by bridging B and S as many times you want. See ,,User Mode", page 10. P > 8 bar If the pressure (>8 bar) switches the unit on, it will switch directly into the Measurement Mode (see page 17).
The unit switches off automatically after 3 minutes if no entry has been made and the pressure is less than 8 bar. See also ,,Overview user interface", page 26.
Uwatec® Digital Pressure Gauge
9
English
Set Up Procedure Before the first dive
Before the first dive the value of the tank pressure alarm and the units for the pressure and temperature indication has to be set. Without new settings the default settings will be valid.
User Mode
/ The User Mode allows to... · read the logbook (pressure difference, pressure at the beginning and at the end of a dive). See page 19. · set the value of the user selectable tank pressure alarm. Setting can be made between 30 and 100 bar (450-1500 psi) in steps of 10 bar (150 psi). See page 11. · select the unit of the pressure and temperature indication. See page 13. On page 26 and 27 a graphical overview of the user interface is shown. If the display is switched off, bridge B and E to enter into the User Mode. If the unit indicates the tank pressure (Measurement Mode), the pressure has to be reduced below 8 bar (120 psi) to enter into the User Mode. The User Mode will be left automatically after 3 minutes (switching off) or if the tank pressure exceeds 8 bar (120 psi).
10
Uwatec® Digital Pressure Gauge
Set Up Procedure
The User Mode is programmed as a loop, which can be run through by bridging B and S, as many times you want. See also overview user interface, page 26. If the User Mode is left during the setting of the tank pressure alarm or the units, the indicated value will not been taken in to account, the old setting will be kept.
Set up the tank pressure alarm
Independent of the fixed 50 bar (750 psi) pressure alarm you can enter your own tank pressure alarm value. See also page 6 and 18. The Digital Pressure Gauge has to be in the User Mode (see page 10). Bridge the contacts B and S until the symbols for the Set Up and the tank pressure alarm are indicated. The Digital Pressure Gauge displays the actually set value of the tank pressure alarm. The default value of the user selectable tank pressure alarm is 50 bar (750 psi). If you don`t want to change the indicated valve, bridge the contacts B and S. If you want to change the indicated value, bridge B and E. The value of the tank pressure alarm starts flashing.
until
Uwatec® Digital Pressure Gauge
11
English
Set Up Procedure
· The value of the tank pressure alarm should not be selected lower than 50 bar. Lower values should only be selected if special precautions have been taken. · If a low value of the tank pressure alarm has been selected, the alarm may be activated to late. Serious injury or death from not having enough air may occur. Select the value of the tank pressure alarm high enough! Overview set up tank pressure alarm Each bridging of the contacts B and S increases the value of the tank pressure alarm by 10 bar (150 psi). When the pressure alarm setting reaches 100 bar (1500 psi) the next contact of B, S will loop the alarm setting to 30 bar (450 psi). Bridging the contacts B and E confirms the actual displayed value as the new tank pressure alarm and the displayed alarm value stops flashing. If the measured pressure falls short of this value, the Digital Pressure Gauge activates the tank pressure alarm.
12
Uwatec® Digital Pressure Gauge
Set Up Procedure Set Up pressure and temperature unit
until The Digital Pressure Gauge has to be in the User Mode (see page 10). Bridge the contacts B and S until the symbol for the Set Up Mode and both the pressure and temperature units appear.
English
The Digital Pressure Gauge shows the actual combination of pressure and temperature units. If you don`t want to change the displayed units, bridge the contacts B and S. Overview units To change one or both units, bridge B and E. The displayed units start flashing. The display shows the next combination of units after bridging the contacts B and S. Bridge these contacts until the display shows the units of your choice. Bridging B and E confirms the displayed units as the new combination. The displayed units stop flashing.
Uwatec® Digital Pressure Gauge
13
Set Up Procedure Mounting the high-pressure hose to the first stage
Adaptor The high-pressure hose is mounted on the high-pressure outlet (HP-outlet) of the first stage of the regulator. 1. Mount the high-pressure hose on the HP-outlet. If the threads do not match, you can obtain an adapter from your diving retailer.
HP
2. Tighten the connection with a matching wrench.
Connecting the Digital Pressure Gauge
Make sure that the tank valve is closed and the regulator is depressurised. 1. Place the bayonet ring of the high-pressure hose on the connecting part of the Digital Pressure Gauge in such a manner that the guiding pins of the bayonet ring grip into the guides provided.
14
Uwatec® Digital Pressure Gauge
Set Up Procedure
2. Turn the bayonet ring to the right until it reaches the stop and then let go of the ring. Make sure that the bayonet ring springs back a few millimeters. Check the correctness of the connection by forcefully pressing and pulling the hose. The bayonet ring must have a range of spring of a few millimeters. 3. Open the tank valve and check the tightness of the connections.
Check tank pressure before every dive.
If the pressure exceeds 8 bar the Digital Pressure Gauge switches automatically to the Measurement Mode (see page 17).
Uwatec® Digital Pressure Gauge
15
English
Set Up Procedure Disconnecting the Digital Pressure Gauge
After diving, the Digital Pressure Gauge can be disconnected. Make sure that the tank valve is closed and the regulator is depressurised. The Digital Pressure Gauge cannot be disconnected under pressure.
Never try to disconnect the Digital Pressure Gauge under pressure.
16
Uwatec® Digital Pressure Gauge
Measurement Mode
In the Measurement Mode the Digital Pressure Gauge indicates the tank pressure (numerically and graphically) and the temperature. The Digital Pressure Gauge activates an optical and acoustical alarm if the tank pressure goes below the fixed 50 bar alarm or below the user selected alarm pressure value.
English
Independent of the actual mode of the Digital Pressure Gauge, it activates the Measurement Mode as soon the connected pressure exceeds 8 bar (120 psi).
P > 8 bar
P < 8 bar
If the pressure falls short of 8 bar (120 psi), the unit switches to the User Mode.
Measurement Mode
The number of bars shown in the tank symbol correlates to the relation between the actual pressure and 200 respectively 300 bar, depending on the measured maximum pressure. If the maximum pressure exceeds 250 bar (3600 psi) the number of bars is displayed as a proportion of 300 bar (4500 psi). With a maximum pressure of less than 250 bar (3600 psi) the number of bars is proportional to 200 bar (3000 psi).
Uwatec® Digital Pressure Gauge
17
Tank Pressure Alarm
, In the Measurement Mode the unit alarms the diver if the pressure falls short of the set value of the tank pressure alarm or 50 bar (750 psi). The alarms, given acoustically and graphically, warn about the danger of not having enough air until the end of the dive. The alarms are given on the surface and under water. If the pressure falls short of the set value of the tank pressure alarm or 50 bar (750 psi) the symbol gets indicated and an acoustic alarm signal is given. If the pressure falls under the selected value of the tank pressure alarm, the unit repeats after every 5 bar (50 psi) pressure reduction the acoustical alarm signal.
· Start ascending immediately if an optical or acoustical tank pressure alarm is given. · Even if the Digital Pressure Gauge gives no tank pressure alarm, the air reserve can be used up before the end of the dive. Frequently check the tank pressure and start ascending early enough. · If you don`t start ascending after a tank pressure alarm, you may not have enough air until the end of the dive. · If the pressure is less than 8 bar, there is no warning given by the Digital Pressure Gauge.
18
Uwatec® Digital Pressure Gauge
Preparation for the Dive
Make sure before each dive that the · Digital Pressure Gauge is correctly mounted (see page 14) · selected value of the tank pressure alarm is high enough (see page 11)
· If the air reserve is to low for your dive, it may result in serious injury or death. Check the tank pressure before each dive. · Never dive with leaky equipment! Check the connections and the instruments against leaking parts.
Logbook
The logbook stores the tank pressure at the beginning and the end of the last dive and displays the pressure difference. The Digital Pressure Gauge has to be in the User Mode (see page 10). Bridge the contacts B and S until the Logbook symbol appears. Pressure difference: Beginning/end
Uwatec® Digital Pressure Gauge
19
English
Logbook
If the tank pressure exceeds 8 bar, the unit switches to the Measurement Mode. After 3 minutes in the Logbook Mode, it switches off automatically. Pressure at the beginning The User Mode is programmed as a loop that can be run through by bridging B and S, as many times you want. See overview user interface page 26. The Logbook stores the pressure data of a dive if the pressure has been at least during 3 minutes higher than 8 bar and the pressure reduction between the beginning and the end was at least 10 bar. Pressure at the end The Logbook of a new unit contains test values.
Battery Warning
The battery has to be replaced if the battery symbol unit to an authorised Uwatec retailer. , appears. Bring the
If the maintenance symbol appears, do not continue diving with the Digital Pressure Gauge anymore. If the symbol appears during a dive: start ascending immediately! If the maintenance symbol appears, the display may be blocked without further warning. Take the unit to your authorised Uwatec Dealer for battery exchange.
20
Uwatec® Digital Pressure Gauge
If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Diplodocs provides you a fast and easy access to the user manual SCUBAPRO-UWATEC DIGITAL MANOMETER. SCUBAPRO-UWATEC offer a product for which we do not have the user manual? Let us know what you are looking for: site Internet, histoire, actualité, filiales, site Internet, mode d'emploi, driver, avis des utilisateurs, meilleur prix des produits, forum d'assistance aux problèmes, annuaire des marques, annuaire des constructeurs, répertoire des marques, répertoire des constructeurs, site Internet de la marque, site Internet du constructeur Diplodocs allows you to download user manual SCUBAPRO-UWATEC DIGITAL MANOMETER, user guide SCUBAPRO-UWATEC DIGITAL MANOMETER, instructions SCUBAPRO-UWATEC DIGITAL MANOMETER, owner's manual SCUBAPRO-UWATEC DIGITAL MANOMETER, online manual SCUBAPRO-UWATEC DIGITAL MANOMETER.Access web reviews SCUBAPRO-UWATEC DIGITAL MANOMETER, SCUBAPRO UWATEC, Sport. |
![]() |
Include the add-on to download manuals from your site, forum or blog | ![]() |
Frequently Asked Questions | ![]() |
Contact Diplodocs team | ![]() |
Last searches Last additions |
![]() |
Sitemap | ![]() |
|||
| Brands starting with A B C D E F G H I J K L M N O P Q R S T U V W X Y Z # | |||||||||||||
|
|
Copyright © 2005 - 2008 - Diplodocs -
All Rights Reserved. Designated trademarks and brands are the property of their respective owners. |