Download user guide, user manual, owner manual and instructions guide
5 600 brands
1 870 000 user's guides
Search a brand
Advanced Search



Our partners wish to propose you the following products


Visit SEKONIC official site

User manual SEKONIC L-188 AUTO LEADER

Diplodocs help download the user guide SEKONIC L-188 AUTO LEADER.



Download the user manual SEKONIC L-188 AUTO LEADER  
Download the complete
user guide (420 Ko)
Need help, support, reviews, tips or troubleshooting for your SEKONIC L-188 AUTO LEADER products ?

Preview of the first 3 pages of manual

You either have JavaScript turned off or an old version of Adobe Flash Player
Get the latest Flash Player.
User guide SEKONIC L-188 AUTO LEADER

Detailed instructions for use are in the User's Guide.

Instruction for Use Sensor (1) Battery check mark (2) Guide mark (3) Pointer (4) Switch button (5) Movie scale (6) Shutter speed scale (7) f/number scale (8) DIN scale (9) ASA scale (10) EV scale (11) ASA set knob (12) Dial ring (13) Battery compartment cap (14) Battery check button (15) The Auto-Leader is a very handy carry around exposure meter. It allows the exposure to be measured very easily thanks to its pointer-tracking system which is based on the guide mark. Specifications Measurement system: Reflected light system Measurement range: E V3 to 18 (ASA 100) Angle of incoming light:65° Scales: * ASA (DIN) . . . 6 (9) to 12000 (42) * f/number . . . . . . . . . . . 1 to 64 * Shutter speed (T) . . 8 to 1 /2000 sec. * EV . . . . . . . . . . . . . . -2 to 19 * Movie scale . . 8 to 128 frames/second Dimensions: 81 x 52 x 19.3mm Weight: 50 g (incl. battery) Preparing to operate Battery Use a 1.5V silver oxide battery (G13 AS designation). First, use a coin to remove the battery compartment cap (14) by rotating it to the left. Now load the silver oxide battery with the (+) side face up. Remove the battery if you do not intend to use the unit for a long period of time. Battery check The exposure meter needle will not point to the correct value if the voltage of the battery falls below the rating, and so it is a good idea to check the voltage before use. Depress the battery check button (1 5) and if the battery check mark (2) is not indicated by the needle (41, replace the battery with a new one. De not depress the switch button (5) when checking the battery. Operation Film speed setting Set the film speed setting which you intend to use. How to set the film speed For the correct setting on the ASA scale (10), rotate the ASA set knob (12) and align the white mark on the black dial with the red scale unit in the ASA window. Reading out the exposure When the sensor (1 ) is pointed in the direction of the subject, the pointer (4) deflects in accordance with the brightness of the subject. To read out the exposure, rotate the dial (13) and set so that the pointer (4) is aligned with the center of the guide mark. The correct exposure will be the combination of the shutter speed scale (7) unit on the dial and the f/number (8) unit. In the illustrated example, f/4 will be the correct exposure at 1 /125 sec. and f/5.6 at 1 /60 sec. Dial scales The numbers /2, /4 and /8, etc. on the shutter speed scale (7) signify 1 /2, 1/4, 1/8 sec. etc., and the numbers 1, 2 and 4, etc., signify 1, 2, 4 sec., etc. The numbers 1 .6M, 3.2M, etc. on the ASA scale (10) signify 1600, 3200, etc. Movie scale (6) Measuring the exposure for movie cameras is performed in exactly the same way as that for ordinary still cameras except that the number of frames (8, 16, 32, etc.) is taken into consideration. Read out the value on the f/number scale (8) which best agrees with the number of frames of the movie camera and then transfer this setting to the camera. With a movie camera shutter open angle of 180°, the standard number of frames is 24, and this is indicated by the black line. The standard number of frames with single 8 and super 8 movie cameras is 18 and this is indicated by the black dot. EV scale If your camera has an exposure value type of shutter, determine the exposure using the exposure value scale (EV scale). If you are, for instance, using an ASA100 film, set the EV scale to '10' with an EV10 value. If the f/number of the camera is set to 5.6 at this value, the shutter speed will automatically go to 1 /30 sec. and to 1 /8 sec. with an f/11 setting. Interim scale units The interim units on the dial scales are as follows: Interim values of the ASA scale (10) [DIN scale (91)] Printed in Japan

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Diplodocs provides you a fast and easy access to the user manual SEKONIC L-188 AUTO LEADER.

SEKONIC offer a product for which we do not have the user manual? Let us know what you are looking for: user guide, owner's manual, online manual, operating instructions, quick start guide, mounting instructions, schematics, service manual, installation instructions, RTFM.

Diplodocs allows you to download user manual SEKONIC L-188 AUTO LEADER, user guide SEKONIC L-188 AUTO LEADER, instructions SEKONIC L-188 AUTO LEADER, owner's manual SEKONIC L-188 AUTO LEADER, online manual SEKONIC L-188 AUTO LEADER.


Access web reviews SEKONIC L-188 AUTO LEADER, SEKONIK,
Include the add-on to download manuals from your site, forum or blog Frequently Asked Questions Contact Diplodocs team Last searches
Last additions
Sitemap
Brands starting with A B C D E F G H I J K L M N O P Q R S T U V W X Y Z #
Copyright © 2005 - 2008 - Diplodocs - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.