User manual SHARP AF-S155NX
Preview of the first 3 pages of manual
You either have JavaScript turned off or an old version of Adobe Flash Player Get the latest Flash Player.
Manual abstract: user guide SHARP AF-S155NX
Detailed instructions for use are in the User's Guide. AF-S155NX
N
Please read ALL instructions before installing. Two people are recommended to install this product. If a new electrical outlet is required, have the outlet installed by a qualified electrician before installing unit. See#5 in Preliminary Instructions following.
SAFETY LOCK AND 3/4" LONG HEX HEAD SCREW WINDOW SASH SEAL
Preliminary instructions
Do the following before starting to install unit. See illustrations below. Check dimensions of your unit to determine model type:
WASHER HEAD LOCKING SCREW FRAME ASSEMBLY (LEFT)
TOP ANGLE FOAM GASKET
Unit Height: Unit Width: Min. Window Opening: Min. Window Width: Max. Window Width:
17.5/8" 23 1/2" 18 1/2" 26 1/2" 40 1/2"
SIDE RETAINER
SEAL-BOTTOM RAIL TO UNIT 1/2" LONG SCREWS AND LOCKNUTS FRAME ASSEMBLY (LEFT) WINDOW SUPPORT BRACKET
1. Check window opening size - the mounting parts furnished
with this air conditioner are made to install in a wooden sill double-hung window. The standard parts are for window dimensions listed above. Open sash to a minimum of 19"(483mm). (FIG. 1)
LOCKNUT 3/4" LONG FLAT HEAD BOLT
SILLANGLE BRACKET
3. Check your storm windows - if your storm window 2. Check condition of window - all wood parts of window
must be in good shape and able to firmly hold the needed screws.If not, make repairs before installing unit.
frame does not allow the clearance required, correct by adding a piece of wood as shown in FIG.2, or by removing storm window while room air conditioner is being installed. (continued)
FIG. 1
SASH
FIG. 2
SASH
19" MIN 19" MIN 1/2" MIN
BOARD THICKNESS AS REQUIRED, ALONG STORM WINDOW FRAME OR OTHER OBSTRUCTION STORM WINDOW FRAME OR OTHER OBSTRUCTION ENTIRE STOOL, FASTEN WITH TWO NAILS OR SCREWS.
1/2" MIN
1 1/2" MIN
4. CHECK FOR ANYTHING THAT COULD BLOCK AIRFLOW - check area outside of window for things such as shrubs, trees, or awnings. Inside, be sure furniture, drapes, or blinds will not stop proper air flow. 5. Check the available electrical service - power supply must be the same as that shown on the unit serial nameplate. Power cord is 48"long. Be sure you have an outlet near.
Tools Required
a large flat blade screwdriver tape measure adjustable wrench or pliers pencil Level Socket wrenches Phillips screwdriver
All models have a 3-prong service plug to provide proper service and safe positive grouding. Do not change plug in any way. Do not use an adapter plug. If your present wall outlet does not match your plug, call a qualified electrician to make the needed change. Avoid fire hazard or electric shock. Do not use an extension cord or an adaptor plug. Do not remove any prong from the power cord.
Grounding type wall receptacle Do not, under any circumustances, cut, remove, or bypass the grounding prong.
WARNING
Hardware (in plastic bag)
Washer Head Locking Screw For window panels 3/4" Long HexHead Screw Safety Lock Qty. 2
3
1
1/2" Long Screw and locknut 3/4" Long Flat Head Bolt and Locknut Sill Angle Bracket
4 ea.
2 ea.
Power supply cord with 3-prong grounding plug and current detection device
2
6. Carefully unpack air conditioner - remove all packing material. Protect floor or carpet from damage. Two people should be used to move and install unit. Long hex-head locking screw for top angle, side retainer 5/16" Long 10
2 1
Install Top Angle and Side Bracket
Remove Chassis
1. Attach foam gasket to top angle above holes as shown in FIG. 6. FIG. 6
1. Pull down front panel and remove filter. (See FIG. 1). 2. Lift front upwards and place to one side.
FIG. 1 FIG. 2
3. Locate the four front screws and remove. These screws will be needed to re-install the front later. (See FIG.2) 4. Pry away front from cabinet sides as per photo (see FIG.3) 5. Gently lift front off unit and place to one side (See FIG.4).
FIG. 3 FIG. 4
2. Install top angle and side retainers to cabinet as shown in FIG. 6.
3
Assemble Window Filler Panels
1. Place cabinet on floor, a bench, or a table. 2. Slide "I" section of window filler panel into side retainer on the side of the cabinet (see Figures 7-8). Do both sides. FIG. 7
6. Remove shipping crews from top of unit and also on the side by the base if installed. 7. Hold the cabinet while pulling on the base handle, and carefully remove the unit. 8. Add two foam inserts to holes in top of cabinet where shipping screws were removed from.
PLASTIC FRAME
WINDOW FILLER PANEL
SIDE RETAINER
FIG. 8
AIR CONDITIONER CABINET PLASTIC FRAME
TOP VIEW
"I" SECTION
LOCKING SCREW WINDOW HOLE FILLER PANEL
3. Insert top and bottom legs of window filler panel frame into channel in the to angle and bottom rail. Do both sides. 4. Insert washer head locking screws (2) into holes in top leg of filler panel frame (see Step 6). Do not totally tighten. Allow leg to slide freely. Screws will be tightened after Section 6.
5
Install Support Bracket
1. Hold each support bracket flush against outside of sill, and tight to bottom of cabinet as shown below. Mark brackets at top level of sill, and remove.
4
Place Cabinet in Window
1. Open window and mark center of window stool.
MARK
2. Place cabinet in window with bottom stool angle firmly scated over window stool as shown. Bring window down temporarily behind top angle to hold cabinet in place.
STOOL
LEFT LOCKNUT SILL ANGLE BRACKET FLAT HEAD BOLT
1/2" LONG SCREWS AND LOCKNUTS
RIGHT
STOOL ANGLE
2 EACH REQ'D FOR EACH SUPPORT BRACKET
3. Shift cabinet left or right as needed to line up center of cabinet on center line marked on stool. 4. Fasten cabinet to window stool with 2 screws into holes.(You may wish to pre-drill pilot holes.) 5. Add bottom rail seal over screws to window stool.
2. Asscmble sill angle bracket to support brackets at the marked position, as shown. Hand tighten, but allow for any changes later. 3. Install support brackets (with sill angle brackets attached) to correct hole in bottom of cabinet as shown. 4. Tighten all 6 bolts securely.
Bottom Rail Seal
1/2" long screws and locknuts
3/4" long HEXHEAD SCREW
6
Extend Window Filler Panels
8
1. Carefully raise window to expose filler panel locking screws. Loosen screws so filler panels slide easily.
Install Chassis into Cabinet and Install Front to Unit
DO not push on controls OR finned coils.
1. Lift air conditioner and carefully slide into cabinet leaving 6" protruding. 2. 3. Be sure chassis is firmly seated towards rear of cabinet. 4. Installation of front is the reverse of removal outlined in Section 1.
LOCKING SCREWS
2. Extend panels to fill window opening completely. Tighten locking screws on top. 3. Close window behind top angle.
7
Install Window Lock and Sash Seal
1. Trim sash seal to fit window width. Insert into space between upper and lower sashes.
WINDOW SASH SEAL
2. Attach right angle safety lock as shown.
SAFETY LOCK 3/4" long hexhead screw
TO CHANGE TEMPERATURE SETTING:
YOU WILL SEE:
DO THIS: PRESS TO RAISE PRESS TO LOWER
) Note: Tap or hold either up ( ¡ø or down ( ) button until the desired temperature is seen on the display. This temperature will be automatically maintained anywhere between 60oF (16oC) and 90oF (32oC) for cooling mode. If you want the display to read the actual room temperature. See "To Operate on Fan " section on Page 13. ¡ø
TO ADJUST FAN SPEEDS:
YOU WILL SEE :
DO THIS: PRESS TO SELECT: FASTER SLOWER
Press the Fan Faster button will increase the fan speed from Low (LO), to Medium (ME), to High (HI). The digital display will indicate your chosen speed. Press the Fan Slower button will decrease the fan speed from High (HI), to Medium (ME), to Low (LO).The digital display will indicate your chosen speed.After 5 seconds the display will revert back to the set temperature.
TO USE AUTO COOL FEATURE:
LIGHT On
YOU WILL SEE:
DO THIS: PRESS AUTO COOL
Note: Fan speed starts at High Speed and adjusts to a slower speed as the room temperature dictates, For example if the room doesn't get too warm, it will stay at the slowest speed. If the room temperature rises quickly,such as a door being opened, it will automatically go to the highest speed. The fan speeds will re-adjust back to the slowest speed as the room returns to the original set temperature.
TO OPERATE ON FAN:
LIGHT On
YOU WILL SEE:
DO THIS: PRESS MODE BUTTON CHOOSE FAN
Note: Use this function only when cooling is not desired, such as for room air circulation or to exhaust stale air. (Remember to open the vent during this function, but keep it closed during cooling for maximum cooling efficiency.) You can choose any fan speed you prefer. (Except "Auto Cool"). During this function, the display will show the actual room temperature, not the set temperature as in the cooling mode.
TO USE THE ENERGY SAVE FEATURE:
LIGHT On
YOU WILL SEE:
DO THIS: PRESS MODE BUTTON CHOOSE ENERGY SAVE
Note: In this mode, the fan will continue to run for another 3 minutes after the compressor shuts off. The fan then cycles on for 2 minutes at 10 minute intervals until the room temperature is above the set temperature, at which time the the cooling system turns back on.
TIMER: TIMER ON/OFF
FIRST DO THIS:
LIGHT On
YOU WILL SEE HOW MUCH TIME IS CHOSEN:
PRESS TIMER BUTTON
THEN DO THIS: PRESS TEMP/TIMER SET BUTTON
Note 1: For Timer Off, the unit must be in the On position. Note 2: For Timer On, the unit must be in the Off position. To adjust timer setting, tap or hold the UP arrow ( ¡ø ) or the DOWN arrow ( ) to change delay timer at 0.5 hour increments, up to 10 hours, then at 1 hour increments up to 24 hours. The control will count down the time remaining until start (8, 7.5, 7, etc.). The Timer On mode automatically selects cooling with maximum Fan Speed. The temperature maintained will be the same as previously set. To change the set temperature, press "MODE" then Up or Down arrows until the desired temperature is indicated on the display. After 5 seconds, the control will automatically change the display back to the hours remaining until the unit will start/stop. Turning the unit "On" or "Off" at any time will cancel the Timer On/Off function. The Timer On/Off Feature will work until the unit either starts or stops. Once that happens the above steps have to be repeated again. ¡ø
FAULT CODES
TO TURN UNIT OFF:
DO THIS: PRESS POWER ON/OFF
If the display reads "ES" or "AS", a sensor has failed. Contact your Authorized SHARP Service Center.
Fresh Air Vent Control
The Fresh Air Vent allows the air conditioner to: 1. Recirculate inside air - Vent Closed (see Fig. 1) 2. Draw fresh air into the room - Vent Open (see Fig. 2) 3. Exchange air from the room and draws fresh air into the room - Vent and Exhaust Open (see Fig. 3)
Fig. 1 (OFF)
Fig. 2 (FRESH AIR)
Fig. 3 (VENT)
The louvers will allow you to direct the air flow Up or Down and Left or Right throughout the room as needed.Rotate the Auger Wheel Up or Down until the desired direction is obtained.
(4-WAY)
AUGER WHEEL
66129901273
... |
|||||||
| Know our Partners | Frequently Asked Questions | Contact Diplodocs team | Last searches Latest additions |
Sitemap | ![]() |
||||||||
| Brands starting with A B C D E F G H I J K L M N O P Q R S T U V W X Y Z # | |||||||||||||
|
|
Copyright © 2005 - 2008 - Diplodocs -
All Rights Reserved. Designated trademarks and brands are the property of their respective owners. |