ROOM AIR CONDITIONER
INSTALLATION AND OPERATION MANUAL
CONTENTS
PAGE
FOR YOUR PROTECTION .................... 2 CONSUMER LIMITED WARRANTY ..... 3 INSTALLATION INSTRUCTIONS
· CHECK WINDOW AREA ........................ · LOCATlON .............................................. · ACCESSORIES ...................................... · SUGGESTED TOOLS ............................ · INSTALLATION ....................................... 4 4 5 5 6
PRECAUTIONS · CAUTION FOR USE ............................ · GROUNDING INSTRUCTIONS ........... · NOTES ON OPERATION .................... · ENERGY EFFICIENCY TIPS ...............
8 8 9 9
This INSTALLATION AND OPERATION MANUAL explains the proper use of your new Sharp Air Conditioner. Read these instructions carefully before installing or operating your air conditioner. The INSTALLATION AND OPERATION MANUAL should be kept in a safe place for handy reference.
HOW TO OPERATE · PARTS NAMES ................................... 10 · COOLING OPERATION ...................... 11 · TO CHANGE TEMPERATURE SETTING .......... 11 · TO CHANGE FAN SPEED AND OPERATION MODE .. 12 · ENERGY SAVER ................................. 13 · TO CHANGE AIR FLOW DIRECTION ....... 13 · ON TIMER OPERATION ..................... 14 · OFF TIMER OPERATION .................... 15 · USING THE REMOTE CONTROL ....... 16 CLEANING AND MAINTENANCE ........ 18 BEFORE CALLING FOR SERVlCE ...... 19
As an ENERGY STAR Partner, Sharp Electronics has determined that these products (AF-S50CX, AFS60CX) meet the ENERGY STAR guidelines for energy efficient air conditioners. To meet these guidelines, air conditioners must be at least 15% more efficient than the minimum Federal standard.
FOR YOUR PROTECTION
To aid in answering questions if you call for service or for reporting loss or theft, please record below the model and serial number located on the right side of the unit.
MODEL NUMBER SERIAL NUMBER DATE OF PURCHASE Dealer Name Address City State Zip Telephone
TO PHONE: Dial 1-800-BE-SHARP (237-4277) for:
SERVICE (for your nearest Sharp Authorized Servicer) PARTS (for your Authorized Parts Distributor) ACCESSORIES ADDITIONAL CUSTOMER INFORMATION
TO WRITE: For service problems, warranty information, missing items and other assistance:
Sharp Electronics Corporation Customer Assistance Center 1300 Naperville Drive Romeoville, IL 60446-1091
Please provide the following information when you write or call: model number, serial number, date of purchase, your complete mailing address (including zip code), your daytime telephone number (including area code) and description of the problem.
2
CONSUMER LIMITED WARRANTY
CONSUMER LIMITED WARRANTY SHARP ELECTRONICS CORPORATION warrants to the first consumer purchaser that this Sharp brand product (the "Product"), when shipped in its original container, will be free from defective workmanship and materials, and agrees that it will, at its option, either repair the defect or replace the defective Product or part thereof with a new or remanufactured equivalent at no charge to the purchaser for parts or labor for the period(s) set forth below. This warranty does not apply to any appearance items of the Product nor to the additional excluded item(s) set forth below nor to any Product the exterior of which has been damaged or defaced, which has been subjected to improper voltage or other misuse, abnormal service or handling, or which has been altered or modified in design or construction. In order to enforce the rights under this limited warranty, the purchaser should follow the steps set forth below and provide proof of purchase to the servicer. The limited warranty described herein is in addition to whatever implied warranties may be granted to purchasers by law. ALL IMPLIED WARRANTIES INCLUDING THE WARRANTIES OF MERCHANTABILITY AND FITNESS FOR USE ARE LIMITED TO THE PERIOD(S) FROM THE DATE OF PURCHASE SET FORTH BELOW. Some states do not allow limitations on how long an implied warranty lasts, so the above limitation may not apply to you. Neither the sales personnel of the seller nor any other person is authorized to make any warranties other than those described herein, or to extend the duration of any warranties beyond the time period described herein on behalf of Sharp. The warranties described herein shall be the sole and exclusive warranties granted by Sharp and shall be the sole and exclusive remedy available to the purchaser. Correction of defects, in the manner and for the period of time described herein, shall constitute complete fulfillment of all liabilities and responsibilities of Sharp to the purchaser with respect to the Product, and shall constitute full satisfaction of all claims, whether based on contract, negligence, strict liability or otherwise. In no event shall Sharp be liable, or in any way responsible, for any damages or defects in the Product which were caused by repairs or attempted repairs performed by anyone other than an authorized servicer. Nor shall Sharp be liable or in any way responsible for any incidental or consequential economic or property damage. Some states do not allow the exclusion of incidental or consequential damages, so the above exclusion may not apply to you. THIS WARRANTY GIVES YOU SPECIFlC LEGAL RIGHTS. YOU MAY ALSO HAVE OTHER RIGHTS WHICH VARY FROM STATE TO STATE.
Your Product Model Number & Description:
AF-S50CX, AF-S60CX, AF-R50CX, AF-R55CX, AF-R60CX or AF-R70CX Room Air Conditioner. Be sure to have this information available when you need service for your Product. One (1) year parts and labor from date of purchase. The warranty period continues for a total of five (5) years from date of purchase for the Sealed Cooling System parts; labor and service are not provided free of charge for this additional period. Appearance items of the Product, knobs, filter, or accessories, mounting kit, seals, or any printed materials. From a Sharp Authorized Servicer located in the United States. To find the location of the nearest Sharp Authorized Servicer, call Sharp Toll Free at 1-800-BE-SHARP. Contact your Sharp Authorized Servicer to obtain in-home service for this Product. The Servicer will come to your home, and if it is necessary to remove the Product, the Servicer will reinstall it. Be sure to have Proof of Purchase available.
Warranty Period for this Product:
Additional Item(s) Excluded From Warranty Coverage (If any): Where to Obtain Service:
What to Do to Obtain Service:
TO OBTAIN SUPPLY, ACCESSORY OR PRODUCT INFORMATION, GO TO OUR WEBSITE AT www.sharp-usa.com OR CALL 1-800-BE-SHARP.
SHARP ELECTRONICS CORPORATION
Sharp Plaza, Mahwah, New Jersey 07430-2135
3
INSTALLATION INSTRUCTIONS
Before beginning installation, read these instructions carefully. Use the enclosed MOUNTING KIT for proper installation.
CHECK WINDOW AREA
The mounting kit is designed for wooden sill double or single hung sash-type windows. Minimum opening (Without mounting kit) 17 23/32" (450mm) Mounting kit fully closed 21 21/32" (550mm) Mounting kit fully opened 33 7/16" (850mm)
Window opening from stool to lower sash bottom must be 14 27/32" (377mm) or more.
Lower sash bottom
Stool
LOCATION
· The air conditioner should be installed on a firm foundation to minimize noise and vibration. For safe installation, repairs, replacement and secure positioning, make sure foundation is solid and level. · The room air conditioner must be installed in an area within reach of a properly rated grounded outlet. · Use of extension cords of any kind is not recommended. · Never place any obstacles around air inlet.
4
INSTALLATION INSTRUCTIONS
ACCESSORIES
1
No.
1
2
Accessories Right closure assembly Left closure assembly Window sash foam seal Window sash foam seal (adhesive type) Bottom gasket Screws (L=1", 25.4mm) Screws (L= 13/32", 10mm) Base pan angle Remote control Battery Remote control hook
Q'ty 1 1 1 1 1 7 6 2 1 2 1
9
7
2
3 4
3
5
6 7 8 9 10 11
4 5
6
6
7
8
2
10
11
2
SUGGESTED TOOLS
1. Screw driver (medium size Phillips) 2. Tape measure or ruler 3. Knife or scissors
5
INSTALLATION INSTRUCTIONS
INSTALLATION
WARNING: Make sure the unit is turned off and unplugged before working.
1 2
Cut the window sash foam seal (adhesive type) to the proper length and attach it to the underside of the window sash.
Jamb Sill
Sash
Window sash foam seal (adhesive type)
Insert the right closure assembly and the left closure assembly into the top angle and the bottom channels. Secure the right and left closure to the cabinet with six of the provided screws. (L= 13/32", 10mm)
Closure assembly
3
Open the window sash and place the air conditioner on the sill. Balance the unit on the sill and close the window sash securely behind the top angle.
WARNING:
At this step, make sure the unit is inclined approximately 1 cm (3/8") to the back. If the unit is not properly inclined, the water collected in the bottom tray during operation will not drain properly and may flow into the room where the air conditioner is installed.
unit
sill
incline backwards approximately 1cm (3/8")
4
6
Insert the bottom gasket into the space between the window sill and the bottom of the unit to seal outside air. If there is space between the bottom channel and the sill, fill the gap with a thin board or other hard filler.
Bottom gasket
INSTALLATION INSTRUCTIONS
5
Insert the closure assemblies on both sides into the rails of the jamb.
Jamb (Left) Closure assembly (Left)
Closure assembly (Left)
Indoor side
Indoor side
Sill
1/2 inches (13mm)
Stool
6
Loosen screws on both sides of the cabinet, then hang the base pan angle on and secure the screws again.
7
Secure the base pan angle to the sill by using the hole of the front side on the angle with one screw. (L=1", 25.4mm)
Top angle
8
Secure the top angle of the unit and the top of the closure assemblies to the sash with three of the provided screws. (L=1", 25.4mm) And secure the bottom of the closure assemblies to the sill with two of the provided screws. (L=1", 25.4mm)
9
Cut the window sash foam seal to the proper length and seal the opening between the top of the inside window sash and the outside window sash.
Window sash foam seal
7
PRECAUTIONS
CAUTION FOR USE
IMPORTANT: Points to keep in mind when using your air conditioner. · Install the air conditioner by following the installation instructions given in the previous section of this manual. · Make sure the unit is the correct capacity for the area you want to cool. · Do not modify any part of this product. · Do not insert objects into any part of the unit. · Push the AC power plug securely into the receptacle and make sure it is not loose. · Use power circuit with a proper voltage rating.
Use a three-pronged grounded electrical outlet rated 125V, 60Hz, 15 amp or more, AC only as shown on right. Use of an improper voltage rating power circuit can result in damage to the unit and possibly fire.
· Always use a fuse with the proper amp rating. · Use of extension cords of any kind is not recommended.
Two-Pole, 3-wire Grounding Receptacle 15 Amps. 125V.
Do not, under any circumstances, use wire, pins or other objects in place of the proper fuse. If you still elect to use an extension cord, it is absolutely necessary that it be a UL Listed 3-wire grounding type appliance extension cord rated 125 Volts, 15 amp or more.
· Ventilate the room periodically during use, especially if using gas appliances.
GROUNDING INSTRUCTIONS
WARNING: Improper use of the grounding plug can result in the risk of electric shock.
This appliance must be grounded. In the event of an electrical short circuit, grounding reduces the risk of electric shock by providing an escape wire for the electric current. This appliance is equipped with a cord having a grounding wire with a grounding plug. The plug must be plugged into an outlet that is properly installed and grounded.
WARNING: Do not under any circumstances cut or remove the round grounding prong from this plug.
If it is necessary to use an extension cord, use only a UL Listed 3-wire extension cord that has a 3blade grounding plug, and a 3-slot receptacle that will accept the plug on the appliance. The marked rating of the extension cord should be AC 125 Volt, 15 Amp or more. Consult a qualified electrician or serviceman if the grounding instructions are not completely understood, or if doubt exists as to whether the appliance is properly grounded. If a grounding adapter is used, make sure the receptacle box is fully grounded.
3-Pronged receptacle Grounding adapter Grounded receptacle box
3-Pronged plug Grounding prong
Grounded receptacle box Screw Tab for grounding screw
Grounding wire
8
PRECAUTIONS
NOTES ON OPERATION
· Allow 3 minutes for the compressor to restart cooling.
If you turn the air conditioner off and immediately restart it, allow three minutes for the compressor to restart cooling. There ... |