9 562 brands
2 694 000 user's guides


Download your manual, it's FREE! Diplodocs allows you to download several types of document in order to best use your SMEG A2-6 : user manual, user guide, instruction manual.
Search a brand
Advanced Search

User manual SMEG A2-6

Diplodocs help download the user guide SMEG A2-6 .

Download the complete user guide (2394 Ko)





Preview of the first 3 pages of manual

You either have JavaScript turned off or an old version of Adobe Flash Player
Get the latest Flash Player.
Manual abstract: user guide SMEG A2-6

Detailed instructions for use are in the User's Guide.

Contents 1. 2. 3. 4. 5. 6. 7. 8. 9. 10. 11. INSTRUCTIONS FOR SAFE AND PROPER USE_______________ 38 INSTALLING THE APPLIANCE _____________________________ 40 ADAPTATION TO DIFFERENT TYPES OF GAS _______________ 43 FINAL OPERATIONS _____________________________________ 45 DESCRIPTION OF CONTROLS ____________________________ 47 USING THE COOKING HOB _______________________________ 53 USING THE OVENS______________________________________ 55 AVAILABLE ACCESSORIES _______________________________ 57 COOKING ADVICE ______________________________________ 58 CLEANING AND MAINTENANCE ___________________________ 65 EXTRAORDINARY MAINTENANCE _________________________ 69 THESE INSTRUCTIONS ARE VALID ONLY FOR END USER COUNTRIES WHOSE IDENTIFICATION SYMBOLS APPEAR ON THE COVER OF THIS MANUAL. INSTRUCTIONS FOR THE INSTALLER: these are for the qualified technician who must carry out a suitable check of the gas system, install the appliance, set it functioning and carry out an inspection test. INSTRUCTIONS FOR THE USER: these contain user advice, description of the controls and the correct procedures for cleaning and maintenance of the appliance. @ Further information www.smeg.com about the products can be found at 37 Introduction 1. INSTRUCTIONS FOR SAFE AND PROPER USE THIS MANUAL IS AN INTEGRAL PART OF THE APPLIANCE AND THEREFORE MUST BE KEPT IN ITS ENTIRETY AND IN AN ACCESSIBLE PLACE FOR THE WHOLE WORKING LIFE OF THE COOKER. WE ADVISE READING THIS MANUAL AND ALL THE INSTRUCTIONS THEREIN BEFORE USING THE COOKER. ALSO KEEP THE SERIES OF NOZZLES SUPPLIED. INSTALLATION MUST BE CARRIED OUT BY QUALIFIED PERSONNEL IN ACCORDANCE WITH THE REGULATIONS IN FORCE. THIS APPLIANCE IS INTENDED FOR DOMESTIC USES AND CONFORMS TO CURRENT REGULATIONS IN FORCE. THE APPLIANCE HAS BEEN BUILT TO CARRY OUT THE FOLLOWING FUNCTIONS: COOKING AND HEATING-UP OF FOOD. ALL OTHER USES ARE CONSIDERED IMPROPER. THE MANUFACTURER DECLINES ALL LIABILITY FOR USES OTHER THAN THOSE STATED ABOVE. DO NOT LEAVE THE PACKING IN THE HOME ENVIRONMENT. SEPARATE THE VARIOUS WASTE MATERIALS AND TAKE THEM TO THE NEAREST SPECIAL GARBAGE COLLECTION CENTRE. IT IS OBLIGATORY FOR THE ELECTRICAL SYSTEM TO BE GROUNDED ACCORDING TO THE METHODS REQUIRED BY SAFETY RULES. THE PLUG TO BE CONNECTED TO THE POWER CABLE AND THE SOCKET MUST BE THE SAME TYPE AND MUST CONFORM TO CURRENT REGULATIONS. THE SOCKET MUST BE ACCESSIBLE AFTER THE APPLIANCE HAS BEEN BUILT IN. NEVER UNPLUG BY PULLING ON THE CABLE. IMMEDIATELY AFTER INSTALLATION CARRY OUT A BRIEF INSPECTION TEST OF THE APPLIANCE, FOLLOWING THE INSTRUCTIONS BELOW. SHOULD THE APPLIANCE NOT FUNCTION, DISCONNECT IT FROM THE SUPPLY AND CALL THE NEAREST TECHNICAL ASSISTANCE CENTRE. NEVER ATTEMPT TO REPAIR THE APPLIANCE. ALWAYS CHECK THAT THE CONTROL KNOBS ARE IN THE POSITION (OFF) WHEN YOU FINISH USING THE HOB. NEVER PUT INFLAMMABLE OBJECTS INTO AN OVEN: THEY COULD BE ACCIDENTALLY LIGHTED AND CAUSE FIRES. 38 Introduction THE IDENTIFICATION PLATE WITH THE TECHNICAL DATA, SERIAL NUMBER AND BRAND NAME IS IN A VISIBLE POSITION INSIDE THE STORAGE COMPARTMENT. DO NOT REMOVE THIS PLATE FOR ANY REASON. DO NOT INSTALL THIS APPLIANCE ON A RAISED PLATFORM. DURING USE THE APPLIANCE BECOMES VERY HOT. TAKE CARE NOT TO TOUCH THE HEATING ELEMENTS INSIDE THE OVEN. DO NOT PUT PANS WITHOUT PERFECTLY SMOOTH AND FLAT BOTTOMS ON THE COOKING HOB PAN STANDS. DO NOT USE CONTAINERS OR BROILERS THAT EXTEND BEYOND THE OUTER PERIMETER OF THE HOB. THE USE OF THIS APPLIANCE IS NOT PERMITTED TO PEOPLE (INCLUDING CHILDREN) OF REDUCED PHYSICAL AND MENTAL ABILITY, OR LACKING IN EXPERIENCE IN THE USE OF ELECTRICAL APPLIANCES, UNLESS THEY ARE SUPERVISED OR INSTRUCTED BY ADULTS OR PEOPLE RESPONSIBLE FOR THEIR SAFETY. THIS APPLIANCE IS MARKED ACCORDING TO THE EUROPEAN DIRECTIVE 2002/96/EC ON WASTE ELECTRICAL AND ELECTRONIC EQUIPMENT (WEEE). THIS DIRECTIVE DETERMINES THE STANDARDS FOR THE COLLECTION AND RECYCLING OF WASTE ELECTRICAL AND ELECTRONIC EQUIPMENT APPLICABLE THROUGHOUT THE EUROPEAN UNION. BEFORE THE APPLIANCE IS PUT INTO OPERATION, ALL THE LABELS AND PROTECTIVE FILMS APPLIED INSIDE OR OUTSIDE MUST BE REMOVED. The manufacturer cannot be held liable for damage to persons or things caused by failure to comply with the above requirements or by tampering with any part of the appliance or by the use of non-original spare parts. 39 Instructions for the installer 2. INSTALLING THE APPLIANCE It is the law that all gas appliances are installed by competent persons. Corgi gas installers are approved to work to safe and satisfactory standards. All gas installation, servicing and repair work must be in accordance with the gas safety regulations 1984 (installation and use) as amended 1990. It may be installed against walls one of which is higher than the worktop surface, at least 50 mm from the side of the appliance, as shown in the installation class drawings A and B. Wall units or extractor hoods installed above the appliance's work-top must be at least 750 mm above it. A Built-in appliance Free-standing installation B 2.1 Electrical connection Make sure the voltage and the cross-section of the power supply line match the specifications indicated on the identification plate positioned in the storage compartment. Do not remove this plate for any reason. The plug at the end of the power cable and the wall socket must be the same type (conforming to regulations in force). Check that the power line is adequately grounded. Do not use reducers, adapters or shunts. If the appliance is connected to the power grid using a fixed connection, fit the power supply line with a multipolar cut-out device with a contact opening gap equal to or greater than 3 mm in an easily accessible position close to the appliance. 40 Instructions for the installer For operation on 380-415V3N: use a 2 H05RR-F-type five-core cable (5 x 1.5 mm ). For operation on 380-415V2N: use a H05RR-F-type four-core cable (4 x 1.5 mm2). For operation on 220-240V: use a H05RRF-type three-core cable (3 x 2.5 mm2). The cable end to be connected to the appliance must be provided with an ground wire (yellow-green) at least 20 mm longer. The manufacturer cannot be held liable for damage to persons or things caused by failure to comply with the above requirements or by tampering with any part of the appliance. 2.2 Ventilation requirements The room containing the appliance should have an air supply in accordance with B.S. 5440 part 2 1989. 1. All rooms require an opening window or equivalent, and some rooms will require a permanent vent as well. 3 2 2. For room volumes up to 5 m an air vent of 100 cm is required. 3. If the room has a door that opens directly to the outside, and the room 3 exceeds 1 m no air vent is required. 3 3 2 4. For room volumes between 5 m and 10 m an air vent of 50 cm is required. 5. If there are other fuel burning appliances in the same room B.S. 5440 part 2 1989 should be consulted to determine the air vent requirements. 3 6. This appliance must not be installed in a sitting room of less than 20 m or in a bathroom or shower room. Windows and permanent vents should therefore not be blocked or removed without first consulting a Corgi gas installer. Failure to install appliances correctly is dangerous and could lead to prosecution. 41 Instructions for the installer 2.3 Connecting to natural and LPG gas (Please see connection diagram) Make the connection to the appliance using flexible bayonet style hose in accordance to B.S. 669. The hose connection at the rear of the appliance has a 1/2" BSP internal thread. Please use seal C between the flexible connection L and the appliance supply tube B. When making the connection, make sure that no stress of any kind is applied to the cooker and that the hose does not touch any sharp edges. If connecting to LPG the bayonet hose must have red bands on it. 2.4 Instruction for wall fixing (only on some models) 1) 2) 3) 4) Fix the screw to the wall and hook the chain (B); Hook the chain to the hole positioned at the rear of the cooker by the gas pipe (A); Once the chain is in position, push the cooker against the wall; The height of the screw hole from floor level must not exceed 800 mm (C). A B C 42 Instructions for the installer 3. ADAPTATION TO DIFFERENT TYPES OF GAS Before carrying out the following operations, disconnect the appliance from the electricity supply The cooker hob is preset for natural gas G20 (2H) at a pressure of 20 mbar. In the case of functioning with other types of gas the burner nozzles must be changed and the minimum flame adjusted on the gas taps. To change the nozzles, proceed as described below. 3.1 Replacement of nozzles on the hob This operation requires no primary air regulation. 1. Extract the pan stands and remove all the caps and flame-spreader crowns; 2. Unscrew the burner nozzles with a 7 mm socket wrench; 3. Replace the nozzles according to the type of gas to be used and the description in paragraph "3.2 Burner and nozzle characteristics table". Replace the burners in the correct position. 43 Instructions for the installer 3.2 Burner and nozzle characteristics table Burner Rated heating capacity (kW) Nozzle diameter 1/100 mm Auxiliary Semi rapid Rapid Ultra rapid 1.05 1.8 3.0 3.9 50 65 85 100 LPG ­ G30/G31 28/37 mbar Reduced capacity Capacity Capacity g/h G30 76 131 218 284 g/h G31 75 129 214 279 (W) 400 500 800 1600 Burner Rated heating capacity (kW) Natural gas ­ G20 20 mbar Nozzle diameter 1/100 mm Auxiliary Semi rapid Rapid Ultra rapid 1.05 1.8 3.0 3.9 72 97 115 135 Reduced capacity (W) 400 500 800 1600 3.3 Arrangement of burners on cooking hob BURNERS 1 2 3 4 5 Auxiliary Semi rapid Rapid Ultra rapid Ultra rapid 44 Instructions for the installer 4. FINAL OPERATIONS After replacing the nozzles, reposition the flame-spreader crowns, the burner caps and the pan stands. After adjustment to a different kind of gas from the one for which the cooker has been tested, replace the plate inside the storage compartment with one corresponding to the new kind of gas. This plate can be obtained from your nearest Authorised Assistance Centre. 4.1 Adjustment of minimum for natural gas Light the burner and take it to the minimum . Remove the gas tap knob and turn the adjustment screw inside or at the side of the tap shaft (depending on the model) until there is a regular minimum flame. Replace the knob and check burner flame stability: (rapidly turning the knob from maximum to minimum position, the flame should not go out). Repeat the operation on all the gas taps. 4.2 Adjustment of minimum for LPG To adjust the minimum for LPG, completely tighten (clockwise) the screw inside or next to the gas tap pin (depending on the model). The diameters of the by-passes for each burner are given in table "3.2 Burner and nozzle characteristics table". 4.3 Positioning and levelling of the appliance Having carried out the electricity and gas hook-up, level the appliance using the four adjustable legs. 45 Instructions for the installer 4.4 · · Mounting the skirt Position the skirt above the top, taking care to align holes A with holes B. Secure the skirt to the top by tightening screws C. 46 Instructions for the user 5. DESCRIPTION OF CONTROLS 5.1 Front control panel All the cooker controls and commands are on the front panel. The user has only to press the central key for 1 - 2 seconds to enable use of the oven on first use or after a power blackout. DESCRIPTION OF SYMBOLS REAR LEFT-HAND REAR RIGHT-HAND FRONT LEFT-HAND FRONT RIGHT-HAND FRONT CENTRAL BURNER MAIN OVEN THERMOSTAT MAIN OVEN FUNCTIONS REAR CENTRAL BURNER AUXILIARY OVEN THERMOSTAT AUXILIARY OVEN FUNCTIONS COOKING HOB BURNER COMMAND KNOB The flame is lit by pressing the knob and turning it anticlockwise to maximum flame . To adjust the flame turn the knob between maximum ( ) and minimum ( ). The burner goes out when the knob is returned to the position . 47 Instructions for the user THERMOSTAT KNOB (OVENS) Selection of cooking temperature is carried out by turning the knob clockwise to the required temperature, between 50° and 250°C. The indicator light comes on to indicate that the oven is warming up. When it goes out it means that the required temperature has been reached. Regular flashing means that oven temperature is being constantly maintained at the programmed level. FUNCTION SWITCH KNOB (OVENS) Turn the knob to select from the following functions: Main oven Auxiliary oven Main oven Auxiliary oven MAIN OVEN NO FUNCTION SET AUXILIARY OVEN NO FUNCTION SET UPPER AND LOWER HEATING ELEMENTS UPPER AND LOWER HEATING ELEMENTS + VENTILATION GRILL ELEMENT UPPER AND LOWER HEATING ELEMENTS UPPER HEATING ELEMENT LOWER HEATING ELEMENT GRILL ELEMENT + VENTILATION GRILL ELEMENT LOWER HEATING ELEMENT + VENTILATION LOWER HEATING ELEMENT + FAN-ASSISTED HEATING ELEMENT FAN-ASSISTED HEATING ELEMENT + VENTILATION DEFROSTING UPPER HEATING ELEMENT + GRILL GRILL + ROTISSERIE EL ...

  Know our Partners   Frequently Asked Questions   Contact Diplodocs team   Last searches
Latest additions
  Sitemap
Brands starting with A B C D E F G H I J K L M N O P Q R S T U V W X Y Z #
Copyright © 2005 - 2008 - Diplodocs - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.