9 562 brands
2 694 000 user's guides


Download your manual, it's FREE! Diplodocs allows you to download several types of document in order to best use your SUB-ZERO 245-PS : user manual, user guide, instruction manual.
Search a brand
Advanced Search

Need help using a product?
Look at the reviews on SUB-ZERO 245-PS

User manual SUB-ZERO 245-PS

Diplodocs help download the user guide SUB-ZERO 245-PS .

Download the complete user guide (108 Ko)





Preview of the first 3 pages of manual

You either have JavaScript turned off or an old version of Adobe Flash Player
Get the latest Flash Player.
Manual abstract: user guide SUB-ZERO 245-PS

Detailed instructions for use are in the User's Guide.

Planning Information Undercounter Model 245 Refrigerator / Freezer Adjustable refrigerator control Interchangeable door hinge Stationary glass shelves Serial and model number plate Automatic ice maker Model 245 Removable ice bucket Stationary door shelves Interior freezer light Front venting with removable kickplate Adjustable freezer control from the full-size units Sub-Zero offers in its Built-In and Integrated lines of refrigeration, we round out our product line-up with a line of traditional Undercounter refrigeration which meets all of the exacting standards you have grown to expect from Sub-Zero. This beautifully crafted undercounter refrigerator / freezer is a must for that special bar area in the home. It features an automatic ice maker giving your client more than enough ice for those special parties, auto defrost and Sub-Zero quality. Panels are available from Sub-Zero but the beauty of this model is really seen when you apply custom panels. Aside MODEL 245 Undercounter refrigerator / freezer combination unit 24" (610) depth-true design for a complete built-in look Door accepts custom panels Smooth surface, easy-to-clean bright interior Automatic ice maker provides an ample supply of crescent-shaped ice Automatic defrost Interchangeable hinge allows door swing to be reversed in the field Front venting with removable kickplate allows unit to be serviced from the front Solid core door with magnetic gasket and door closer UL approved for US and Canada Two, five and twelve year residential warranty-- exclusions apply; warranty information can be found on our website, subzero.com Dimensions in parentheses are in millimeters unless otherwise specified. 11/06 1 Planning Information Undercounter Model 245 S P E C I F I C AT I O N S Model 245 Overall Width Overall Height O P T I O N A L D O O R PA N E L S Undercounter Refrigerator / Freezer with Automatic Ice Maker 23 7/8" (606) 34 " (864) 24" (610) 3 cu ft (85 L) 1.9 cu ft (54 L) 34 " (864) 25 13/16" (656) 115 V AC, 60 Hz, 15 amp circuit 444 kWh / $ 41 139 lbs (63 kg) Overall Depth Refrigerator Capacity Freezer Capacity Minimum Height (levelers in) Door Swing Clearance White Enamel Steel Almond Enamel Steel Classic Stainless Steel ACCESSORIES Electrical Requirements Hinge conversion kit Accessories are available through your Sub-Zero dealer. To obtain local dealer information, visit the Locator section of our website, subzero.com. Annual Energy Usage (based on 9.06 cents per kilowatt hour) Shipping Weight Special Note Door accepts custom wood panels or panels are available as sales accessories Specifications are subject to change without notice. OVERALL DIMENSIONS 34" (864) 25 13/16" (656) 23 7/8" (606) 24" (610) 24" (610) Dimensions may vary by ± 1/8" (3). Dimensions in parentheses are in millimeters unless otherwise specified. 2 Planning Information Undercounter Model 245 I N S TA L L AT I O N S P E C I F I C AT I O N S WATER SUPPLY LOCATION 1/2" (13) 12" (305) 24" (610) ROUGH OPENING DEPTH TOP VIEW 24"(610) ROUGH OPENING WIDTH LOCATE ELECTRICAL WITHIN SHADED AREA 341/2" (876) ROUGH OPENING HEIGHT 7" (178) 1" (25) 7" (178) E 2" (51) FRONT VIEW DIMENSIONS Finished Rough Opening Width Finished Rough Opening Height Finished Rough Opening Depth Location of Electrical Location of Water Supply 24" (610) 34 1/2" (876) 24" (610) Within shaded area (front view) Within shaded area (top view) See Installation Instructions shipped with unit for detailed specifications. Dimensions in parentheses are in millimeters unless otherwise specified. 3 Planning Information Undercounter Model 245 I N S TA L L AT I O N N OT E S Refer to the illustrations and specifications for overall dimensions, finished rough opening dimensions and installation specifics. The Model 245 lower hinge extends out from the side of the unit in the area of the kickplate. When the unit is installed tightly against a full-depth panel or cabinet, there can be interference. Refer to the full-scale illustration on page 6. For Model 245 with automatic ice maker, rough in the water supply line. Connect a 1/4" OD copper line to the house supply, being sure to use an easily accessible shut off valve between the supply and the unit. Do not use self-piercing valves. A saddle valve kit (4200880) is available from your Sub-Zero dealer. To obtain local dealer information, visit the Locator section of our website, subzero.com. A line filter is required when water conditions have a high sediment content. The ice maker operates on water pressure of 20 psi (1.4 bar) to 100 psi (6.9 bar). In some cases a reverse osmosis water filter system may not be able to maintain the minimum water pressure consistently. A 115 V AC, 60 Hz, 15 amp fused electrical supply is required. It is recommended that a separate circuit, serving only this appliance, be provided. All Undercounter models are equipped with a power supply cord with a 3-prong grounding plug which must be plugged into a mating 3-prong grounding type wall receptacle. Locate electrical within the shaded area shown in the illustration on page 3. You must follow all National Electrical Code regulations. In addition, be aware of local codes and ordinances when installing your service. Refer to the Undercounter Installation Instructions packed with the appliance, which provides step-by-step procedures for making sure the unit is installed properly. Dimensions in parentheses are in millimeters unless otherwise specified. 4 Planning Information Undercounter Model 245 F R A M E D PA N E L S PANELS 1/4" (6) THICK OR LESS Framed door panels must be 1/4" (6) thick around the perimeter. If the panel is thicker than 1/4" (6), an edge must be routed around the panel to ensure a proper fit. The edge must be 1/4" (6) thick and you must allow 3/8" (10) around the perimeter for the frame. Model 245 requires no handle recess. Refer to the illustrations on this page. IMPORTANT NOTE: The Model 245 lower hinge extends out from the side of the unit in the area of the kickplate. When the unit is installed tightly against a full-depth panel or cabinet, there can be interference. Refer to the full-scale illustration on pge 6. The overlay door panel design application is not available for the Model 245. Trim reveal 1/4" (6) min 1/4" (6) Panel Framed door panel 1/4" (6) thick or less IMPORTANT NOTE: The weight of the panel cannot exceed 20 lbs (9 kg). PANELS THICKER THAN 1/4" (6) Trim reveal 1/4" (6) min Rout to 1/4" (6) thickness F R A M E D PA N E L D I M E N S I O N S Door Panel Width Door Panel Height Maximum Panel Weight 23 1/2" (597) 28 1/8" (714) 20 lbs (9 kg) Framed door panel thicker than 1/4" (6) H W Framed Door Panel Dimensions in parentheses are in millimeters unless otherwise specified. 5 Planning Information Undercounter Model 245 MODEL 245 ­ LOWER HINGE TOP VIEW 237/8" (606) WIDTH OF UNIT BOTTOM HINGE EXTENDS 1/4" (6) FROM SIDE OF UNIT UP TO 31/2" (89) FROM FLOOR DOOR 233/4" (603) TO BACK OF UNIT Dimensions in parentheses are in millimeters unless otherwise specified. 6 ...

  Know our Partners   Frequently Asked Questions   Contact Diplodocs team   Last searches
Latest additions
  Sitemap
Brands starting with A B C D E F G H I J K L M N O P Q R S T U V W X Y Z #
Copyright © 2005 - 2008 - Diplodocs - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.