Detailed instructions for use are in the User's Guide.
Planning Information
Integrated Model 700BC(I)
Refrigerator / Freezer Drawers
Seamless molding
Removable crisper cover
Location of serial number
Electronic digital control panel
Model 700BC
Magnetic drawer gaskets
Upper storage drawer  refrigerator
Automatic ice maker Model 700BCI with Ice Maker Front venting with removable kickplate Lower storage drawer  freezer
These appliances are Star-K certified from the factory to meet strict religious regulations in conjunction with specific instructions found on star-k.org. No extra wiring harness is required.
The Sub-Zero Model 700BC and 700BCI integrated design accepts custom wood or stainless steel drawer panels. Stainless steel panels and handles are available as sales accessories in three finishes--classic, platinum and carbon.
Combining the best of both worlds, the Model
700BC(I) offers you convenient refrigeration and freezer storage in a compact "footprint." The implications for the installation of this piece are obvious--entertainment centers, recreation rooms, master suites, boardrooms and bars are a few that come instantly to mind. Temperatures are easily controlled via the handy control panel in the top drawer and Sub-Zero's microprocessor will maintain them precisely. The top refrigerator drawer comes with removable crisper cover. You also have the option of ordering this model with or without an automatic ice maker.
Dimensions in parentheses are in millimeters unless otherwise specified. 11/06
1
Planning Information
Integrated Model 700BC(I)
F E AT U R E S
Drawer unit with upper refrigerator storage drawer and lower freezer storage drawer Model 700BCI has automatic ice maker Integrated design for "point-of-use" refrigeration anywhere in the home Microprocessor offers precise temperature control for refrigerator and freezer drawers Electronic digital controls are easily accessed in the top refrigerator drawer Flat to the ceiling bright lighting in storage drawers
Alarm will let you know with an audible beeping if a drawer is left open Removable crisper cover with a clear-view window and removable divider in refrigerator storage drawer Meets strict Department of Energy requirements UL approved for US and Canada Two, five and twelve year residential warranty  exclusions apply; warranty information can be found on our website, subzero.com
OVERALL DIMENSIONS
27"
3/8" (10) (686) (UNIT DIMENSION)
24"
(610) (UNIT DIMENSION)
131/4" 1/2" (337) (13)
DRAWER MOUNTING DETAIL
24"
(610)
341/2"* 101/4"
(260) (876) DRAWER CLOSED
203/8"
(518)
93/4"
(248)
191/2"*
(495)
4"
FRONT VIEW
_ *1/2" (13) + ADJUSTMENT IN LEVELING LEGS
(102)
SIDE VIEW
257/8" (657)
TOP VIEW
*DRAWER PANEL THICKNESS NOT INCLUDED
Dimensions may vary by ± 1/8" (3).
Dimensions in parentheses are in millimeters unless otherwise specified.
2
Planning Information
Integrated Model 700BC(I)
S P E C I F I C AT I O N S
Model 700BC(I) Overall Width Overall Height Overall Depth
MODEL OPTIONS
Drawer Combination Unit 27" (686) 34 1/2" (876)
24" (610) 2.9 cu ft (82 L) 2.1 cu ft (59 L) 34" (864) 19 1/2" (495) 115 V AC, 60 Hz, 15 amp circuit
1/4"
Drawer Combination Unit Drawer Combination Unit with Automatic Ice Maker
700BC 700BCI
Refrigerator Capacity Freezer Capacity Minimum Height (levelers in) Drawer Clearance
PA N E L O P T I O N S
Electrical Requirements Plumbing Requirements /S /P /B Water Supply
Integrated (custom panels) Classic Stainless Steel Finish Platinum Stainless Steel Finish Carbon Stainless Steel Finish
copper line 20Â100 psi
Annual Energy Usage (based on 9.06 cents per kilowatt hour) Shipping Weight Special Note
448 kWh / $ 41 190 lbs (86 kg)
Stainless steel drawer front panels are ordered and shipped as sales accessories and include tubular handles.
Drawer panels and handles are available in three stainless steel finishes
Specifications are subject to change without notice.
ACCESSORIES
Drawer front panels with tubular handles in classic, platinum and carbon stainless steel Tubular handles in classic, platinum and carbon stainless steel and polished chrome Dozen egg container with lid Dual installation heater kit
Accessories are available through your Sub-Zero dealer. To obtain local dealer information, visit the Locator section of our website, subzero.com.
Dimensions in parentheses are in millimeters unless otherwise specified.
3
Planning Information
Integrated Model 700BC(I)
I N S TA L L AT I O N S P E C I F I C AT I O N S
TOP VIEW
ANTI-TIP BRACKET*
TOP VIEW
6"
(152)
11/2"
(38)
(635)
25"
13 1/2"
(343)
15 1/2"
(394)
9"
(229)
(686)
27"
13 1/2"
(343)
ANTI-TIP BRACKET
(686)
27"
WATER LINE BOTTOM ENTRY LOCATION *PLACEMENT OF THE ANTI-TIP BRACKET SHOULD BE 24" (610) FROM THE FRONT OF THE UNIT WITHOUT PANELS TO THE BACK OF THE ANTI-TIP BRACKET.
WATER LINE SIDE ENTRY LOCATIONS
11/2"
(38)
11/2"
(38)
(686)
27"
(635)
25"
341/2"
(876)
NOTE: ANTI-TIP BRACKET MUST BE INSTALLED TO PREVENT UNIT FROM TIPPING FORWARD
ANTI-TIP BRACKET
WATER LINE SIDE ENTRY LOCATION
FRONT VIEW
LOCATE ELECTRICAL WITHIN SHADED AREA Â ORIENT GROUND PRONG TO RIGHT AS SHOWN ANTI-TIP BRACKET LOCATE WATER LINE (REAR ENTRY) WITHIN SHADED AREA
SIDE VIEW
4 1/2"
(114)
3"
(76)
1/4" (6)
13" (330) 2 1/2" (64) 15 1/2" (394)
9"
(229)
3/4" (19)
DIMENSIONS
Finished Rough Opening Width Finished Rough Opening Height Finished Rough Opening Depth Location of Electrical Location of Plumbing
27" (686) 34 1/2" (876) 25" (635)* Within shaded area Within shaded area
* The depth of the Model 700BC(I) is 24" (610) from the front of the unit to its back. Your design may necessitate moving the unit back, or cabinets forward to achieve a flush fit. This will require a minimum rough opening depth of 25" (635). See Installation Instructions shipped with unit for detailed specifications. Dimensions in parentheses are in millimeters unless otherwise specified.
4
Planning Information
Integrated Model 700BC(I)
I N S TA L L AT I O N N OT E S
Refer to the illustrations and specifications for overall dimensions, finished rough opening dimensions and installation specifics. IMPORTANT NOTE: The depth of Model 700BC(I) is 24" (610) from the front of the unit to its back. Your design may necessitate moving the unit back, or cabinets forward to achieve a flush fit. This will require a minimum rough opening depth of 25" (635). Refer to the installation illustration on page 4. The anti-tip bracket must be installed to prevent the unit from tipping forward. Integrated units are compatible with virtually any style of cabinetry. They can be used with framed as well as frameless cabinets. The weight of each drawer panel cannot exceed 12 lbs (5 kg). Drawer panels must be a minimum of 5/8" (16) thick. For the bottom drawer, the maximum panel height is 16 11/16" (424). You must keep a minimum space of 4" (102) clear below the bottom edge of the lower drawer panel, so the unit can be properly vented. In addition, any decorative base molding must be removable for possible servicing and cleaning of the condenser. We recommend using D-style handles, which should be located on the top, center area of the drawer panel. Two Integrated units may be installed next to one another. Refer to page 10 for additional information. For Integrated models with an automatic ice maker, rough in the water supply line. Connect a 1/4" OD copper line to the house supply, being sure to use an easily accessible shut-off valve between the supply and the unit. This shut-off valve should not be installed behind the unit. Do not use self-piercing valves. A saddle valve kit (4200880) is available from your Sub-Zero dealer. To obtain local dealer information, visit the Locator section of our website, subzero.com.
A line filter is required when water conditions have a high sediment content. The ice maker operates on water pressure of 20 psi (1.4 bar) to 100 psi (6.9 bar). In some cases a reverse osmosis water filter system may not be able to maintain the minimum water pressure consistently. When routing the water through the side walls, you must place the water line within 1/2" (13) of the floor and as close as possible to the back wall. The line must be routed around the anti-tip bracket so it clears the bracket and leveling feet of the unit. Refer to the installation illustration on page 4 for placement of the water line. Do not route water supply line in front of the compressor tray. The tray must be slid forward for service. Regardless of the routing, allow for 27" (686) of excess copper tubing to remain outside the wall or floor for easy connection to the unit, as shown in the installation illustration on page 4. A 115 volt, 6OHz, 15 amp circuit breaker and electrical supply are required. A separate circuit, servicing only this appliance is necessary. All Integrated models are equipped with a power supply cord with a 3-prong grounding plug, which must be plugged into a mating 3-prong grounding type wall receptacle. The electrical outlet must be placed so the grounding prong is to the right of the thinner blades. The outlet must be flush with the back wall. Locate electrical within the shaded area shown in the installation illustration on page 4. Do not use an extension cord or two prong adapter. Electrical ground is required on this appliance. Do not under any circumstances remove the power supply cord ground prong. You must follow all National Electrical Code regulations. In addition, be aware of local codes and ordinances when installing your service. The Integrated Refrigeration Installation Instructions packed with the appliance will give you step-by-step procedures for making sure the unit is installed properly.
Dimensions in parentheses are in millimeters unless otherwise specified.
5
Planning Information
Integrated Model 700BC(I)
C A B I N E T RY A P P L I C AT I O N S
Integrated refrigeration is compatible with virtually any style and look of cabinetry. The models can be used with framed as well as frameless cabinets. Because of the precise application and the look you may want to achieve, there are important questions you need to answer before ordering panels for the drawers. As you look at styles of cabinets, keep some important facts in mind: IMPORTANT NOTE: The depth of each Integrated unit is 24" (610) from the front of the unit to its back. You must allow for the thickness of the panel you are applying when planning for the finished rough opening depth if you want the front panel to be flush with surrounding cabinetry. You may have to move the unit back into drywall or bring the cabinets forward to achieve a flush fit. Weight Limitations  The weight of each drawer panel cannot exceed 12 lbs (5 kg). Panel Thickness  Drawer panels must be a minimum of 5/8" (16) thick. The toe kick clearance can vary with the height of the lower drawer panel; the maximum panel height is 16 11/16" (424). You must keep a minimum space of 4" (102) clear below the bottom edge of the lower drawer panel so the unit can be properly vented. IMPORTANT NOTE: The inside edges of the rough opening, as well as the sides and a portion of the backside of the decorative panels will need to be finished, as they will be exposed when the drawers are open. We recommend using D-style handles. Locate handles in the top center area of the drawer panels.
Dimensions in parentheses are in millimeters unless otherwise specified.
6
Planning Information
Integrated Model 700BC(I)
F R A M E D C A B I N E T RY A P P L I C AT I O N S
Framed cabinetry applications present you with different questions to address. The illustrations on this page show common applications of framed cabinetry. These are not meant to be the only alternatives, but are suggestions from designers around the country.
FRAMED CABINETRY
CABINET FRAME
SUB-ZERO UNIT
24
(610)
TO WALL
IMPORTANT NOTE: The depth of each Integrated unit is 24" (610) from the front of the unit to its back. You must allow for the thickness of the panel you are applying when planning for the finished rough opening depth if you want the front panel to be flush with surrounding cabinetry. You may have to move the unit back into drywall or bring the cabinets forward to achieve a flush fit. Refer to the illustrations. Illustrations on the following pages give dimensions for an Integrated drawer unit installed within a framed cabinetry beaded inset application. Review the illustrations, giving particular attention to the overall panel specifications.
CABINET DOOR
1/8" (3) REVEAL
PANEL
27
(686)
Traditional Frame  full overlay (top view).
2
1
T CABINET FRAME SUB-ZERO UNIT
24
(610)
TO WALL
1
CABINET DOOR
1/8" (3) REVEAL
PANEL
27
(686)
Traditional Frame  standard overlay 2 (top view).
S T
SUB-ZERO UNIT CABINET FRAME
1
24
(610)
TO WALL
2
CABINET DOOR (3) REVEAL
1/8"
PANEL
27
(686)
Traditional Frame  3/8" (10) offset (top view).
Dimensions in parentheses are in millimeters unless otherwise specified.
7
...