5 600 brands
1 870 000 user's guides |
|
|
|||||||||||||||
|
Search a brand
Advanced Search
Where is my user guide?
|
Our partners wish to propose you the following products
|
User manual SYQUEST SYJET PORTABLE SCSI
Diplodocs help download the user guide SYQUEST SYJET PORTABLE SCSI.
You may also download the following manuals related to this product:
Preview of the first 3 pages of manual
You either have JavaScript turned off or an old version of Adobe Flash Player Get the latest Flash Player.
User guide SYQUEST SYJET PORTABLE SCSI
Detailed instructions for use are in the User's Guide. ®
1.5 GB Portable SCSI Removable Cartridge Disk Drive With Parallel Port Option
Installation Guide for PC Compatible Systems
Welcome to SyQuest®
Thank you for buying a SyQuest removable cartridge disk drive, a truly unique combination of powerful features and performance. Our goal is to make your drive an invaluable asset for years to come, starting today. If you have questions or need assistance installing your drive, please contact SyQuest.
SyQuest® Technology is located at 47071 Bayside Parkway, Fremont, CA, 94538-6517. SyQuest's main phone number is 510-226-4000, which has a 24-hour automated system to help direct your calls. You may also contact Sales or Technical Assistance at these online addresses:
Sales
U.S.A. Email sales@syquest.com
Technical Assistance
U.S.A. Email World Wide Web Germany Email United Kingdom Email support@syquest.com http://www.syquest.com
support.de@syquest.com
support.uk@syquest.com
Copyright © 1997 by SyQuest Technology. All rights reserved. This document and all material contained in it are copyrighted. The document may not be copied, in whole or in part, without the written consent of SyQuest Technology.
ii
Contents
Portability with Flexibility . . . . . . . . . . . . . Getting Started . . . . . . . . . . . . . . . . . . . . . Preparing Your SyJet Drive for Installation Installing Your SyJet Drive . . . . . . . . . . . . Installing SyQuest SCSI Software . . . . . . . . Ejecting a Cartridge . . . . . . . . . . . . . . . . . Ejecting a Cartridge Without Power . . . . . SyQuest Utilities Software . . . . . . . . . . . . . Troubleshooting . . . . . . . . . . . . . . . . . . . Drive Letter Assignment Order . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1 .2 .3 .7 12 15 16 17 21 22
iii
iv
Safety Standards
This product meets the following national and international regulations: · UL 1950 Standard for Safety of Information Processing and Business Equipment · UL Standard for Safety of Information Technology · CSA C22.2 No. 154 Data Processing Equipment · CSA C22 No. 220 Information Processing Equipment · IEC 435 Safety Requirements for Data Processing Equipment · IEC 380 Safety of Electrical Energized Office Equipment · IEC 950 Safety of Information Technology Equipment in Electrical Business Equipment · VDE 0871/1984 · VFG 243/1991
Disclaimer
SyQuest Technology makes no warranty of any kind with regard to this material, including, but not limited to, implied warranties of merchantability and fitness for a particular purpose. SyQuest Technology shall not be liable for errors contained in this document or for incidental or consequential damages in connection with the furnishing, performance, or use of this information. The information contained in this document is subject to change without notice. The contents of this document may be revised without prior notice. SyQuest Technology also reserves the right to make changes and/or improvements to its products without incurring any obligation to incorporate such changes or improvements in units previously sold or shipped.
v
FCC Warning
This equipment generates and uses radio frequency energy and, if not installed and used properly, that is, in strict accordance with the manufacturer's instructions, may cause interference to radio and television reception. It has been type-tested and found to comply with the limits for a Class B computing device in accordance with the specifications in Subpart J of Part 15 of FCC Rules, which are designed to provide reasonable protection against interference in a residential installation. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause interference to radio or television reception, which can be determined by turning the equipment off and on, try to correct the interference by one or more of the following measures: · Reorient the antenna. · Relocate the equipment with respect to the receiver. · Move the equipment away from the receiver. · Plug the equipment into a different outlet so that equipment and receiver are on different branch circuits. If necessary, consult your dealer or an experienced radio/television technician for additional suggestions. The booklet entitled How to Identify and Resolve Radio-TV Interference Problems, prepared by the Federal Communications Commission, may be helpful. This booklet, Stock No. 004-000-003454, is available from the U.S. Government Printing Office, Washington, DC 20402.
vi
Notice
SyQuest is a registered trademark in the United States and certain other countries. SyJet is a trademark of SyQuest Technology, Inc. IBM, PC-DOS, MS-DOS, Windows, Windows NT, OS/2, Novell DOS, Macintosh, and UNIX are registered trademarks of other companies. The SyJet removable cartridge disk drive is covered by one or more of the following U.S. Patents: 4,488,187; 4,504,879; 4,683,506; 4,630,190; 4,722,012; 4,870,518; 4,864,437; 4, 920,462; 4,974,103; 4,965,685; 5,038,232; 5,175,657; 5,121,280; 5,204,793; 5,262,918; 5,317,464; DES342,062; 5,400,201; 5,535,072; 5,523,902; 5,526,212. The SyJet removable disk drive cartridge is covered by one or more of the following U.S. Patents: 4,503,474; 4,717,981; 4,864,452; 4,965,691; 5,218,503; 5,280,403; 5,422,775; 5,400,201; 5,523,902; DES367,579; DES342,062. Other U.S. Patents and other nations' patents pending. This disk drive product is protected by SyQuest intellectual property rights including the foregoing patents and additional pending patent applications. Sale of this product does not in any way convey a license, express or implied, under SyQuest's intellectual property rights for use of this product with unauthorized removable disk cartridges.
Technical Data Restrictions
In the case of sale to or use of units by the Department of Defense, use, duplication, or disclosure of any software, firmware, or related documentation is subject to restrictions stated in paragraph (c) (1) (ii) of the "Rights in Technical Data and Computer Software" clause at DFAR 252 227-7013. For civilian agencies, use, reproduction, or disclosure of the software and related documentation is subject to restrictions set forth in FAR 52.227-19. Unpublished rights are reserved under the copyright laws of the United States.
vii
Portability with Flexibility
The SyJetTM portable SCSI drive with Parallel Port Option is really two products in one! This manual provides instructions on connecting the portable drive to your parallel port. You can also connect the portable SyJet drive to a SCSI card. You can use the same drive for both parallel port and SCSI connections--this means portability with flexibility! SyQuest can provide you with the following gear to allow you to connect your SyJet drive to the SCSI connector on your computer:
· SCSI cable and adapters (50 pin SCSI connector at the SyJet end
of the cable, your computer's SCSI connector type at the other end)
· SCSI Installation Manual and diskette
See your SyGear Accessories Brochure for fast and easy ordering information on reasonably-priced SyGear accessories.
1
Getting Started
You can connect the SyJetTM portable SCSI drive with Parallel Port Option to your 386TM, 486TM, or PentiumTM class desktop or tower computer. Your computer must also have the following features to operate the SyJet drive properly:
· A parallel port. The cable provided in this package allows you to
connect your SyJet drive to the printer port while allowing your printer to function normally.
· A compatible operating system from the following list:
· · · · · · · MS-DOSTM 5.0 or higher PC-DOSTM 5.0 or higher Novell DOSTM 7.0 or higher Windows® 3.1 or higher Windows® 95 Windows® NT 3.51 or higher OS/2TM 2.1 or higher
This guide provides detailed step-by-step installation instructions. Installation typically requires about an hour, and requires familiarity with computer hardware and software, as well as some mechanical ability. Please review all instructions in this installation guide, and familiarize yourself with your computer before you install your SyJet drive. Note: The SyQuest parallel port-to-SCSI adapter cable acts as a standard 8-bit terminated SCSI Host Bus Adapter (HBA).You can daisy-chain other SyQuest drives to your SyJet drive (each drive must have a unique SCSI address).
!
Caution: Only SyQuest drives are supported with the adapter cable. Do not connect any other type of SCSI device.
2
1.5 GB Portable SCSI Removable Cartridge Disk Drive
Preparing Your SyJet Drive for Installation
1. Unpack your SyJet drive.
Unpack and inspect the contents of the shipping carton.
SyJet SCSI Removable Cartridge Disk Drive
R EM O VA
RTRI BLE CA
VE RD DRI DGE HA
Parallel Port Adapter Cable
®
®
®
SyQuest® Cartridge in Protective Case Power Adapter
®
®
Handy easy-to-use accessories that help you get the most from your new SyJet or EZ135, in the office, at home, or on the go.
SYGEAR
Carrying Case Extra Cartridges Power Supplies PC SCSI Adapter Kit SCSI & Parallel Cables Active Terminator
Installation Guide
SyGear Accessories Brochure
Installation Guide
Installation Diskette for DOS, Windows 3.1x, and Windows 95, and Drivers for OS/2
Installation Guide for PC Compatible Systems
3
2. Locate your computer's Parallel port.
Your computer's parallel port is located at the back of your computer. The port may be labeled with a printer symbol, and it uses a 25-pin connector. Computer Rear View
1
2
Possible locations of the Parallel (Printer) Port
Do not use the SCSI port
!
Caution: Do not connect the cable to your computer at this time.
4
1.5 GB Portable SCSI Removable Cartridge Disk Drive
3. Study the parts of your SyJet drive.
Front View
Drive Door
Power Button Eject Button Power On LED Drive Activity LED
Rear View
SyJet SCSI Connectors SCSI ID Setting Switch
SCSI IN
SCSI OUT
DC Power Port
Installation Guide for PC Compatible Systems
5
4. Check for devices that have conflicting Interrupt
(IRQ) numbers.
Installed devices make use of Interrupt Request numbers (IRQs) to request services from the computer. In this step, you'll verify that no devices (for example, sound cards) use the IRQs (5 and 7) that are used by the printer port. The parallel port adapter used by the SyJet drive will share the printer port with your installed printer. DOS and Window 3.1: Use the Microsoft MSD.EXE program. If IRQs 5 or 7 are used by a non-printer device, follow the procedure specified in the device's manual to set it to a different IRQ. Windows 95: Under the Start menu, go to Settings, Control Panel. Double-click System; the System Properties property sheet opens. Click the Device Manager tab and double-click Computer; the Computer Properties property sheet opens. Click Interrupt Request (IRQ) to view all IRQ settings on your computer. To change a setting, close the Computer Properties property sheet. In the Device Manager tab of the System Properties property sheet, double-click the device; the device property sheet opens. Click the Resources tab, select Interrupt Request, and click the Change Setting button. You may have to refer to the device's installation documentation to determine how to change the IRQ setting.
6
1.5 GB Portable SCSI Removable Cartridge Disk Drive
Installing Your SyJet Drive
1. Turn off your computer.
Never attach or remove cables while your computer or your SyJet drive is on.
2. Plug the Parallel port adapter cable's 50-pin
connector into the SyJet drive connector labeled SCSI IN.
Computer Parallel Port
1 2
SyJet Drive
Printer
3. Remove the printer cable from the computer, and
plug it into the connector in the middle of the adapter cable.
Installation Guide for PC Compatible Systems
7
4. Plug the 25-pin end of the adapter cable into your
computer's Parallel (printer) port.
!
Caution: Do not attach your SyJet drive to the 25-pin SCSI port found on some PCs.
Note: The SyJet drive must be powered on in order for the printer to operate. If you wish to operate the printer while the SyJet drive is off, you must purchase an accessory power supply for the adapter cable.
5. Plug the power adapter connector into the DC power
port on the rear of the SyJet drive. Plug the power adapter into an AC power outlet.
!
Caution: Use only the SyQuest power adapter provided with the drive--other power adapters may damage your drive.
8
1.5 GB Portable SCSI Removable Cartridge Disk Drive
6. If you will use the drive in the vertical position,
attach the mounting foot to the base of the drive. You can attach the foot anywhere on the base between the rubber pads, as shown.
!
Caution: If you drop your SyJet drive, inspect it. If the plastic case is chipped or otherwise damaged, return it to your SyQuest reseller for inspection. The drive and cartridge can be damaged if the drive tips over while operating, so place the drive in a secure, stable location.
7. Turn on the SyJet drive, then turn on the computer.
The Power On LED glows green to indicate that the SyJet drive is powered on.
Installation Guide for PC Compatible Systems
9
8. Insert a SyJet cartridge into the SyJet drive.
Hold the cartridge as shown below, and open the drive door using your finger or the front end of the cartridge.
Cartridge Front End
Cartridge Drive Door
Slide the cartridge all the way into the drive. Press down gently on the tab until the cartridge snaps into place.
Tab
The drive spins up the cartridge, and the Drive Activity LED flickers amber. The Drive Activity LED glows green when the drive is ready. If the Drive Activity LED does not glow green, eject and re-insert the cartridge. See "Ejecting a Cartridge" on page 15. Note: The SyJet drive automatically goes into a power saving mode after 30 minutes of inactivity. Normal drive activity will restore full power to the drive when needed.
10
1.5 GB Portable SCSI Removable Cartridge Disk Drive
Note: The SyJet drive reads, writes, and formats SyJet cartridges only. The SyJet drive cannot read, write, or format other SyQuest cartridges.
!
Caution: Always remove the cartridge from the SyJet drive before moving or transporting the drive. If you remove or eject the cartridge, you must pull it halfway out in order to reinsert it. This built-in feature prevents partial insertion.
Congratulations, your SyJet drive is installed! Now you'll install some software.
Installation Guide for PC Compatible Systems
11
Installing SyQuest SCSI Software
Note: Do not install the software if the SyJet drive fails to go to the Ready state (steady green Drive Activity LED--the LED on the right). See "Troubleshooting" on page 21.
DOS and Windows 3.1x 1. Exit Windows to DOS.
Press Alt + F4 to exit Windows--do not use a DOS shell.
2. Insert the SyQuest Installation Diskette. 3. At a DOS prompt, type: A:\INSTALL and press Enter.
If your 3.5-inch diskette drive is B:, type B:\INSTALL and press Enter.
4. Follow the installation program prompts. Windows 95 1. Click Start, then select Settings and Control Panel. 2. In the Control Panel window, double-click the
Add/Remove Programs icon.
3. Insert the SyQuest Installation Diskette and click
Install.
Click Next, then click Finish.
4. Follow the instructions in the Installation Wizard
window to complete the software installation.
12
1.5 GB Portable SCSI Removable Cartridge Disk Drive
Windows NT 3.51 1. Run Windows NT Setup from the Main group. 2. From the Options menu, select Add/Remove SCSI
Adapters.
3. Click the Add button, and select Other.
This requires a disk from a hardware manufacturer.
4. Insert the SyQuest Installation Diskette. 5. Click SyQuest EPST Parallel to SCSI Controller
Driver, and click OK.
6. Click the Install button. 7. Reboot to allow the new driver to take effect. Windows NT 4.0
To install your SyJet drive under Windows NT, use the SCSI drivers provided with your SCSI host adapter. Refer to your SCSI host adapter documentation or the SyQuest online manual for details.
1. Run SCSI Adapters from the Control Panel. 2. Click the Drivers tab and click Add. 3. Click the Have Disk button. 4. Insert the SyQuest Installation Diskette. 5. Click SyQuest EPST Parallel to SCSI Controller
Driver, and click OK.
You must use Disk Administrator to prepare your cartridge or add a signature block.
Installation Guide for PC Compatible Systems
13
If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Diplodocs provides you a fast and easy access to the user manual SYQUEST SYJET PORTABLE SCSI. SYQUEST offer a product for which we do not have the user manual? Let us know what you are looking for: user guide, owner's manual, online manual, operating instructions, quick start guide, mounting instructions, schematics, service manual, installation instructions, RTFM. Diplodocs allows you to download user manual SYQUEST SYJET PORTABLE SCSI, user guide SYQUEST SYJET PORTABLE SCSI, instructions SYQUEST SYJET PORTABLE SCSI, owner's manual SYQUEST SYJET PORTABLE SCSI, online manual SYQUEST SYJET PORTABLE SCSI.SYQUEST SYJET PORTABLE SCSI, , Hard Drive, NAS, USB Key & Other external Storage. |
![]() |
Include the add-on to download manuals from your site, forum or blog | ![]() |
Frequently Asked Questions | ![]() |
Contact Diplodocs team | ![]() |
Last searches Last additions |
![]() |
Sitemap | ![]() |
|||
| Brands starting with A B C D E F G H I J K L M N O P Q R S T U V W X Y Z # | |||||||||||||
|
|
Copyright © 2005 - 2008 - Diplodocs -
All Rights Reserved. Designated trademarks and brands are the property of their respective owners. |